HomeMy WebLinkAboutNCG030027 DMR SW (5)Semi-annual Stormwater Discharge Monitoring Report
for North Carolina Division of Water Quality General Permit No. NCG030000
Date submitted 04/20/15
CERTIFICATE OF COVERAGE NO. NCG030027
FACILITY NAME Eaton Corporation - Engine Components Division
COUNTY Person
PERSON COLLECTING SAMPLES Dustin A. LaClair
LABORATORY ESC Lab Cert. # ENV375/DW21704/BI0041
Comments on sample collection or analysis:
SAMPLE COLLECTION YEAR 2015
SAMPLE PERIOD ❑ Jan -June ❑ July -Dec
or ® Monthly' March (month)
DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
RECEIVED ❑Zero -flow ❑Water Supply ❑SA
APR 2 3 2015 ®Other WS -III: NSW
CENTRAL FIDES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3
Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION
F-1 No dischoroe this nPrinrf?2
Outfall No.
Date Sample
Collected '
(mm/dd/yr)
24-hour rainfall
amount,
Inches3
Total Suspended Solids
p
pH'
Standard units
Copper
Co
Lead
Zinc
Non -Polar O&G/
Total Petroleums
Hydrocarbons
Total Toxic
Organics
Benchmarks =__>
-
-
100 mg/L or 50 mg/L4
6.0-9.0
0.007 mg/L
0.03 mg/L
0.067 mg/L
15 mg/L
1 mg/L
Tool Room Trench
(005)
03/26/15
1.07 inches
100 mg/L
7.9
0.016 mg/L
.0041 mg/L
0.045 mg/L
0.72 mg/L*
. .001001
08
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
3The total precipitation must be recorded using data from an on-site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture
electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA
Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor
manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray
tube manufacture use the definition found in 40 CFR 469.31).
* Results returned ND (Not Detected) - Maximum Detection Limits (MDL) reported as result.
Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012
Page 1 of 3
•-
.1 M.CWT.W31MIEf"M
..
• .. NO"-
IMAIIIIIIIN
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format. "<XX me/L", where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOOMROMPH from Pak.A. also apply to this Pan B
Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012
Page 2 of 3
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO ❑
IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ® NO ❑
REGIONAL OFFICE CONTACT NAME: Danny Smith, The Tier III notification and supporting documentation will be sent to the DWQ Regional Office Supervisor in accordance
with the General Stormwater Permit.
Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period
in the case of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
(Signature of Permittee)
Permit Date: 11/1/2012-10/31/2017
50,-"d- Z5-
(Date)
s(Date)
SWU-245, last revised 10/25/2012
Page 3 of 3