Loading...
HomeMy WebLinkAbout710096_Permit Renewal Application 2019_20190410State of North Carolina Department of Environmental Quality Division of Water Resources Animal Waste Management Systems Request for Certification of Coverage Facility Currently covered by an Expiring Sate Non -Discharge General Permit On September 30. 2019, the Norlh Carolina State Non -Discharge General Permits for Animal Waste Management Systems will expire. As required by these permits, facilities that have been issued Certificates of Coverage to operate under these State Non -Discharge General Permits must apply for renewal at least 180 days prior to their expiration date. Therefore, all applications must be received by the Division of Water Resources by no later than April 3, 2019. Please do not leave mry• question nunnsivered. Please verify all information and make m(y necessary corrections belov. Application trust be signed and dater/ AP the Peroittee, I. Farm Number: 71-0096 2. Facility Name: Slonevbrook Fame 3. Landowner's Name (same as on the N'aste Management Plan): 4. Landowner's Mailing Address: PO Box 856 City: Warsaw State: Telephone Number: 910-293-3434 Est E-mail 5. Facility's Physical Address: 5707 Willard Rd City: Wallin State: 6. County where Facility is located: Pender 7. Farm Manager's Name (if different from Landowner): g, Farm Manager's telephone number (include area code): 9. Integrator's Name (if there is not an Integrator, write "None"): 10. Operator Name (OIC): James Derek Brown 11. Lessee's Name (if there is not a Lessee, write "None"): Certificate Of Coverage Number: AWS710096 Murphy -Brown LI C NC Zip: 28398-0856 kcaixveste tauu hvbreavolle.eem NC David C Nordin 910-293-5330 Ext. Coastal Plains Pork Phone No.: 910-289-2111 12. Indicate animal operation type and number: Current Permit: Operations Type Allowable Count Swine - Farrow to Wean 4,000 Operation Types: sl%inf Laak Dry Poultry Wean to Finish Dairy Calf Non Laving Chickens Wean to Feeder Dairy heifer Laying Chickens Farrow to Finish Milk Cow Pullets Feeder to Finish Dry Cow Turkeys Farrow to Wean Beef Stocker Calf Turkey Pullet Farrow to Feeder Beef Feeder Boar/Stud Beef Broad Cow Wet Poultry Gilts Other Non Laving Pullet Other Layers Zip: 28478 OIC #: 19632 Other Types Horses - Horses I lorses- Other Sheep - Sheep Sheep - Other 13. Waste Treatment and Storage Lagoons (Verify the following information is accurate and complete. Make all necessaq, corrections and provide missing data.) Structure Name Estimated Date Built Liner Type (Clay, S) nthetic, Unknown) Capacity (Cubic Feet) Estimated Surface Area (Square Feet) Design Freeboard "Redline' (Tactics) Mail one (1) copy, of the Certified Animal Waste Management Plan (CANVMP) with this completed and signed application as required by NC General Statutes 143-215.IOC(d) to the address below. The CAWMP most include the following components: I. The most recent Waste Ulilization Plan (WUP), signed by the owner and a certified technical specialist, containing: a, The method by which waste is applied to the disposal fields (e.g. irrigation, igjection, etc.) b. A map of every field used for land application (for example: irrigation map) e. The soil series present oti every land application Geld - d. The crops grown on every land application Geld e. The Realistic Yield Expectation (RYE) for every crop shown in the "'UP F. The maximum PAN to be applied to every land application field g. The waste application windows for every crop utilized in the WUP h. The required NRCS Standard specifications 2. A site map/schematic 3. Emergency Action Plan 4. Insect Control Checklist with chosen best management practices noted 5. Odor Control Checklist with chosen best management practices noted 6. Mortality Control Checklist with selected method noted - Use the enclosed updated Mortality Control Checklist 7. Lagoon/storage pond capacity documentation (design, calculations, etc.) Please be sure the above table is accurate and complete. Also provide any site evaluations. wetland determinations, or hazard classifications that may be applicable to your facility. 8. Operation and Maintenance Plan If your CAWMP includes any components not shown on this list, please include the additional components with vour submittal. (e.g. composting digesters, waste transfers, etc.) As a second option to mailing paper copies of the application package, you can scan and email one signet) copy of the application and all the CAWNIP items above to: 2019PermitRenewal a ncdenr.gov I attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that, if all required parts of this application me not completed and that if all .required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes.any false statement, representation, or certification in any application may be subject to civil penalties up to $25,000 per violation. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment of not more than 5 years, or both for a similar offense.) Printed Name of Signing Official (Landowner, or if multiple Landowners all landowners should sign. If Landowner is a corporation, signature should be by a principal executive officer of the corporation): Name: LX C - Title:, '®�_QV\ '�..1�'"�j Signature: Date: — ®� Name: Signature: Name: Title: Date: Title: Signature: Date: THE COMPLETED APPLICATION SHOULD BE SENT TO THE FOLLOWING ADDRESS: NCDEQ-DWR Animal Feeding Operations Program 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Telephone number: (919) 707-9100 E-mail: 2019PermitRenewal@ncdeur.gov FORM: RENEWAL -STATE GENERAL 02/2019 Murphy -Brown, LLC Grower(s): Farm Name: 2/1 /2017 NUTRIENT UTILIZATION PLAN Farrow to Feeder Farrow to Finish Wean to Feeder Wean to Finish Feeder to Finish Gilts Boars Storage Period: Application Method: 2822 Hwy 24 West P.O. Box 856 Warsaw, NC 28398 Murphy -Brown, LLC dba Smithfield Hog Production Stoneybrook; AWS710096 >180 days Irrigation The waste from your animal facility must be land applied at a specified rate to prevent pollution of surface water and/or groundwater. The plant nutrients in the animal waste should be used to reduce the amount of commercial fertilizer required for the crops in the fields where the waste is to be applied. This waste utilization plan uses nitrogen as the limiting nutrient. Waste should be analyzed before each application cycle. Annual soil tests are strongly encouraged so that all plant nutrients can be balanced for realistic yields of the crop to be grown. Several factors are important in implementing your waste utilization plan in order to maximize the fertilizer value of the waste and to ensure that it is applied in an environmentally safe manner: 1. Always apply waste based on the needs of the crop to be grown and the nutrient content of the waste. Do not apply more nitrogen than the crop can utilize. 2. Soil types are important as they have different infiltration rates, leaching potentials, cation exchange capacities, and available water holding capacities. 3. Normally waste shall be applied to land eroding at less than 5 tons per acre per year. Waste may be applied to land eroding at 5 or more tons per acre annually, but less than 10 tons per acre per year providing that adequate filter strips are established. 4. Do not apply waste on saturated soils, when it is raining, or when the surface is frozen Either of these conditions may result in runoff to surface waters which is not allowed under DWR regulations. 5. Wind conditions should also be considered to avoid drift and downwind odor problems. 6. To maximize the value of the nutrients for crop production and to reduce the potential for pollution, the waste should be applied to a growing crop or applied not more than 30 days prior to planting a crop or forages breaking dormancy. Injecting the waste or disking will conserve nutrients and reduce odor problems. 1of11 This plan is based on the waste application method shown above. If you choose to change methods in the future, you need to revise this plan. Nutrient levels for different application methods are not the same. The estimated acres needed to apply the animal waste is based on typical nutrient content for this type of facility. In some cases you may want to have plant analysis made, which could allow additional waste to be applied. Provisions shall be made for the area receiving waste to be Flexible so as to accommodate changing waste analysis content and crop type. Lime must be applied to maintain pH in the optimum range for specific crop production. This waste utilization plan, if carried out, meets the requirements for compliance with 15A NCAC 2H .0217 adopted by the Environmental Management Commission, AMOUNT OF WASTE PRODUCED PER YEAR ( gallons, 111:3, tons, etc.): Ca acit T Waste Produced per Animal Total 4000 Farrow to Wean 3203 gal/yr 12,812,000 galtyr Farrow to Feeder 3861 gaUyr gal/yr Farrow to Finish 10478 gaUyr galtyr Wean to Feeder 191 galtyr gaUyr Wean to Finish 776 gaUyr gaUyr Feeder to Finish 927 gal/yr galtyr Gilts 1015 gal/yr galtyr Boars 2959 gaUyr al/yr Total 12,812,000 allyr AMOUNT OF PLANT AVAILABLE NITROGEN PRODUCED PER YEAR (Ibs): Capacity T Nitrogen Produced per Animal Total 4000 Farrow to Wean 3.84 Ibstyr 15,360 Ibstyr Farrow to Feeder 6.95 Ibstyr Ibstyr Farrow to Finish 18.86 lba/yr Ibstyr Wean to Feeder 0.34 Ibstyr Ibs/yr Wean to Finish 1.4 Ibstyr Ibs/yr Feeder to Finish 1.67 Ibs/yr Ibs/yr Gilts 1.83 lbs/yr Ibs/yr Boars 5.33 lbs/yr Ibstyr Total 15,360 Ibstyr Applying the above amount of waste is a big job. You should plan time and have appropriate equipment to apply the waste in a timely manner. LAND UTILIZATION SUMMARY The following table describes the nutrient balance and land utilization rate for this facility Note that the Nitrogen Balance for Crops indicates the ratio of the amount of nitrogen produced on this facility to the amount of nitrogen that the crops under irrigation may uptake and utilize in the normal growing season. Total Irrigated Acreage: 115.45 Total N Required let Year: 28378.86 Total N Required 2nd Year: 16816.47 Average Annual Nitrogen Requirement of Crops: 22,597.66 Total Nitrogen Produced by Farm: 15,360.00 Nitrogen Balance for Crops: (7,237.66) The following table describes the specifications of the hydrants and fields that contain the crops designated for utilization of the nitrogen produced on this facility. This chart describes the size, soil characteristics, and uptake rate for each crop in the specified crop rotation schedule for this facility. 2of11 Reception Area Specifications Year 1 of a 2 year=p romdon Tract Field Irrigated Soil 1stCmp Timeto 1stCrop 1stCrop Lbs WAc Lb,N Total lbsN Acres e T Code A Yield Ibs WUnit Residual /Ac Utilized T3247 5 3.97 1 Rains D Feb15June 150.00 0.90 15 120.00 476.40 T3247 p1 17.40 Rains D Feb15JUM 750.00 0.90 15 720.00 2088.00 T3247 Lt 18.70 Goltlsbom D FeD15JUM 156.00 0.95 15 733.20 2490.84 T3247 L2 1 21.86 1 Goldsboro D FeblSJune 158.00 0.85 15 733.20 2911.75 2ntl Crop Time 2ntl Crop 2ntl Crop Lbs WAc LbsN TotallbaN Code A 1 Yield Ibs NAtnit Residual /Ac Utiliz0 N Se - r 55.00 1.93 106,15 421.42 N Sa r 55.00 1.93 106.15 1847.01 N -Apr 65.00 2.D9 135.85 1 2640.40 N So -Apr 65.00 2.09 /35.85 2969.68 N Se 55.00 1.93 105.15 1 1434.09 N Se -/1pr 55.00 7.83 706.15 1303.52 N Se -A r 65.00 2.09 135.85 627.63 N Se r 85.00 209 135.85 1050.12 N Se r 55.00 t.93 706.15 437.34 N Sepl-A r 55.00 1.93 106.15 181.52 N Sa -Apr 55.00 1.93 106.15 1013.73 Total Lbs N/Ae Total lbsN Utilized 226.15 22-615 269.05 269.05 226.15 226.15 269.05 289.05 226.75 226.15 226.15 897.82 3935.01 5031.24 5881.43 3055.29 2777.72 1243.01 2079.76 931.74 386.72 2159.73 13247 I L3 1 13.51 12.28 4.82 1 7.73 1 Rains Rains Galdsboro Goltlsbom 11 D D D D IFebi5JUM FaD75JuM Febl5Juna Feb15-JuM 150.00 150.00 158.00 156.00 0.90 0.90 0.95 0.95 15 15 15 15 120.00 120.00 133.20 133.20 1621.20 1473.60 615.38 1029.64 T3247 T3247 L4 Sub2A 13247 Sub28 T3247 Sub3q 4A2 Rains D D D Feb15JUM Feb75-June Feb15-June 150.00 150.00 150.00 0.90 D.90 0.90 15 15 75 120D0 720.00 120.00 494.40 205.20 1146.00 T3247 T326] Sub38 SuD9-5 1.71 9.55 Rains Rains Totals: 115.45 14552.41 1J828.d4 28378.88 3(a) & 11 Reception Tract T3267 T3247 T3247 T3247 Area Field 5 Pi L7 L2 L3 L4 Sub2A Suo28 Specifications Irrigated Acrea e 3.97 17.10 18.70 27.88 73.51 1228 4.62 7.73 Soil T Rains Gogsboro GOMsboro GoMsboro Reins Rains Gdtlsbom Goldsboro Reins Reins Rains Yesr2 of 1st Crop Code O O O O O O O O O O O a 2yearcrop Time to A I AprSepllS rSept75 A Sapt15 Sapt15 rS t5 AprSeptlS AprSopt75 rSeptlS AprSepttS rSe 5 AprSePH5 rotation 15t Crop Yield 37.00 37.00 38.00 38.00 37.00 37.00 38.00 38.00 37.00 37.00 37.00 1st Crop Ibs NIUAN: 3.87 3.87 3.91 3.H7 3.87 3.87 3.97 3.81 3.87 3.87 3.87 Lbs WAc Residual Lbs N /Ac 143.t9 143.t9 148.SB 148.58 143.19 143.19 748.58 148.58 143.19 143.19 143.19 Total Ibs N Utilized 568.46 249i51 2778.45 3247.96 1934.50 1758.37 686.44 1148.52 589.94 244.85 1367.46 2ntl Crop Code Time to A IX 2ntl Crop Yield 2ntl Crap Ibs N/Unit Lbs N/Ac Residual Lbs N /Ac 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Total ibs N Utilized 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Total Total Ibs N Lbs N/Ac Utilized 143.79 143.19 143.19 148.58 143.19 143.19 148.58 148.SB 143.79 143.19 143.19 568.41 568.46 2491778 .51 3247.95 1934.50 1758.37 686.44 1148.52 589.94 244.85 1367.46 T3247 T3247 T3247 T3267 T3247 T3247 Sub3A Sub3B 4.12 1.71 T3247 $ub4-5 9.55 0 tional T3247 T3247 TM47 T3247 Crop: So An Any An Any um suostiMe for Soybeans Reins I Golasooro M Jill M 1 CC S Mar 15-Au Mar I SaPt-Apr W.00 65.00 1.00 1.00 1A7 1.78 30.00 100.00 100.20 115.70 30.00 100.00 0.00 0.00 0.00 0.00 Note: Amount SmaQ Gram PAN eppliW to be ha"ided to mvar flop must as ha , be deaudatl from fdlowin ao startln PAN ra0e. Totals: 175.45 1681&47 0.00 16816.47 3(b) of 11 This plan does not include commercial fertilizer. The farm should produce adequate plant available nitrogen to satisfy the requirements of the crops listed above. The applicator is cautioned that P and K may be over applied while meeting the N requirements. In the future, regulations may require farmers in some parts of North Carolina to have a nutrient management plan that addresses all nutrients. This plan only addresses nitrogen. In interplanted fields ( i.e. small grain, etc, interseeded in bermuda), forage must be removed through grazing, hay, and/or silage. Where grazing, plants should be grazed when they reach a height of six to nine inches. Cattle should be removed when plants are grazed to a height of four inches. In fields where small grain, etc, is to be removed for hay or silage, care should be exercised not to let small grain reach maturity, especially late in the season (i.e. April or May). Shading may result if small grain gets too high and this will definitely interfere with stand of bermudagrass. This loss of stand will result in reduced yields and less nitrogen being utilized. Rather than cutting small grain for hay or silage just before heading as is the normal situation, you are encouraged to cut the small grain earlier. You may want to consider harvesting hay or silage two to three times during the season, depending on the time small grain is planted in the fall. The ideal time to interplant small grain, etc, is late September or eady October. Drilling is recommended over broadcasting. Bermudagrass should be grazed or cut to a height of about two inches before drilling for best results. CROP CODE LEGEND Crop Code Crop Description -Harvested As A B Barley Grain Crop C Grazed Hybrid Bermudagrass Pasture/Grazed Hybrid Bermudagrass Hay Hay B/C D Comb. Hybrid Bermudagrass Graze/Hay Combination E Corn - Grain Grain Crop F Corn - Silage Silage G Cotton Grazed Fescue Cotton Lint Pasture/Grazed H Fescue Hay Hay J Oats Grain Crop K L Rye Grazed Overseed Grain Crop Pasture/Grazed (Seeded in Bermudagrass) M Overseed Hay Hay (Seeded in Bermudagrass) N Grain Sorghum Grain Crop p 0 Wheat Grain Crop P Soybean Grain Crop S Pine Trees Pine Trees cc Small Grain Cover Crop Grain Crop/ Hay (After Grain Crop) SWG Swithgrass Not Harvested; Burned/Disked In Biomass Crop Acres shown in the preceding table are considered to be the usable acres excluding required buffers, filter strips along ditches, odd areas unable to be irrigated, and perimeter areas not receiving full application rates due to equipment limitations. Actual total acres in the fields listed may, and most likely will be, more than the acres shown in the tables. See attached map showing the fields to be used for the utilization of animal waste. 4 of 11 SLUDGE APPLICATION: The following table describes the annual nitrogen accumulation rate per animal in the lagoon sludge Farm Specifications PAN/ r/animal Farm Totally 4000 Farrow to Wean 0.8 3200 Farrow to Feeder 0.96 Farrow to Finish 3.9 Wean to Feeder 0.07 Wean to Finish 0.27 Feeder to Finish 0.34 Gilts 0.39 Boars 0.55 The waste utilization plan must contain provisions for periodic land application of sludge at agronomic rates. The sludge will be nutrient rich and will require precautionary measures to prevent over application of nutrients or other elements. Your production facility will produce approximately 3200 pounds of plant available nitrogen per year and will accumulate in the lagoon sludge based on the rates of accumulation listed above. If you remove the sludge every 5 years, you will have approximately 16000 pounds of plant available nitrogen to utilize. Assuming you apply this PAN to hybrid bermuda grass hayland at the rate of 300 pounds of nitrogen per acre, you will need 53 acreas of land. If you apply the sludge to corn at a rate of 125 pounds per acre, you will need 128 acres of land. Please note that these are only estimates of the PAN produced and the land required to utilize that PAN. Actual values may only be determined by sampling the sludge for plant available nitrogen content prior to application Actual utilization rates will vary with soil type, crop, and realistic yield expectations for the specific application fields designated for sludge application at time of removal. APPLICATION OF WASTE BY IRRIGATION: The irrigation application rate should not exceed the intake rate of the soil at the time of irrigation such that runoff or ponding occurs. This rate is limited by initial soil moisture content, soil structure, soil texture, water droplet size, and organic solids. The application amount should not exceed the available water holding capacity of the soil at the time of irrigation nor should the plant available nitrogen applied exceed the nitrogen needs of the crop. If surface irrigation is the method of land application for this plan, it is the responsibility of the producer and irrigation designer to ensure that an irrigation system is installed to properly irrigate the acres shown in the preceding table. Failure to apply the recommended rates and amounts of nitrogen shown in the tables may make this plan invalid. 'This is the maximum application amount allowed for the soil assuming the amount of nitrogen allowed for the crop is not over applied. In many situations, the application amount shown cannot be applied because of the nitrogen limitation. The maximum application amount shown can be applied under optimum soil conditions. Your facility is designed for >180 days of temporary storage and the temporary storage must be removed on the average of once every 6 months. In no instance should the volume of the waste stored in your structure be within the 25 year 24 hour storm storage or one foot of freeboard except in the event of the 25 year 24 hour storm. It is the responsibility of the producer and waste applicator to ensure that the spreader equipment is operated properly to apply the correct rates to the acres shown in the tables. Failure to apply the recommended rates and amounts of nitrogen shown in the tables may make this plan invalid. Call your technical specialist after you receive the waste analysis report for assistance in determining the amount of waste per acre and the proper application prior to applying the waste. 5of11 Application Rate Guide The following is provided as a guide for establishing application rates and amounts. Soil Application Rate Application Amount Tract Hydrant Type Crop inlhr 'inches T3247 5 Rains D 0.4 1 T3247 P1 Rains D 0.4 1 T3247 L1 Goldsboro D 0.4 1 T3247 L2 Goldsboro D 0.4 1 T3247 L3 Rains D 0.4 1 T3247 L4 Rains D 0.4 1 T3247 Sub2A Goldsboro D 0.4 1 T3247 Sub2B Goldsboro D 0.4 1 T3247 Sub3A Rains D 0.4 1 T3247 Sub3B Rains D 0.4 1 T3247 Sub4-5 Rains D 0.4 1 6of11 Additional Comments: This plan revised to reflect the addition of a center pivot which replaces pulls 1 -4, and also updates the production and application rates to the current rates as listed on the NCSU Nutrient Management website. 7of11 NUTRIENT UTILIZATION PLAN CERTIFICATION Name of Farm: Stoneybrook; AWS710096 Owner: Murphy -Brown, LLC dba Smithfield Hog Production Manager: Owner/Manager Agreement: Uwe understand and will follow and implement the specifications and the operation and maintenance procedures established in the approved animal waste nutrient management plan for the farm named above. I/we know that any expansion to the existing design capacity of the waste treatment and/or storage system, or construction of new facilities, will require a new nutrient management plan and a new certification to be submitted to DWR before the new animals are stocked. I/we understand that I must own or have access to equipment, primarily irrigation equipment, to land apply the animal waste described in this nutrient management plan. This equipment must be available at the appropriate pumping time such that no discharge occurs from the lagoon in the event of a 25 year 24 hour storm. I also certify that the waste will be applied on the land according to this plan at the appropriate times and at rates which produce no runoff. This plan will be filed on site at the farm office and at the office of the local Soil and Water Conservation District and will be available for review by NCDWR upon request. Name of Facility Owner: Murphy -Brown, LLC dba Smithfield Hog Production Signature: Date Name of Manager (if different from owner): Signature: Name of Technical Specialist: Affiliation: Address: Telephone: Signature: 8of11 NUTRIENT UTILIZATION PLAN .REQUIRED SPECIFICATIONS Animal waste shall not reach surface waters of the state by runoff, drift, manmade conveyances, direct application, or direct discharge during operation or land application. Any discharge of waste which reaches surface water is prohibited. There must be documentation in the design folder that the producer either owns or has an agreement for use of adequate land on which to properly apply the waste. If the producer does not own adequate land to properly dispose of the waste, he/she shall provide evidence of an agreement with a landowner, who is within a reasonable proximity, allowing him/her the use of the land for waste application. It is the responsibility of the owner of the waste production facility to secure an update of the Nutrient Utilization Plan when there is a change in the operation, increase in the number of animals, method of application, recieving crop type, or available land. 3 Animal waste shall be applied to meet, but not exceed, the nitrogen needs for realistic crop yields based upon soil type, available moisture, historical data, climatic conditions, and level of management, unless there are regulations that restrict the rate of applications for other nutrients. 4 Animal waste shall be applied to land eroding less than 5 tons per acre per year. Waste may be applied to land eroding at more than 5 tons per acre per year but less than 10 tons per acre per year provided grass filter strips are installed where runoff leaves the field (See USDA, NRCS Field Office Technical Guide Standard 393 - Filter Strips). 5 Odors can be reduced by injecting the waste or disking after waste application. Waste should not be applied when there is danger of drift from the land application field. 6 When animal waste is to be applied on acres subject to flooding, waste will be soil incorporated on conventionally tilled cropland. When waste is applied to conservation tilled crops or grassland, the waste may be broadcast provided the application does not occur during a season prone to flooding (See 'Weather and Climate in North Carolina" for guidance). 7 Liquid waste shall be applied at rates not to exceed the soil infiltration rate such that runoff does not occur offsite or to surface waters and in a method which does not cause drift from the site during application. No ponding should occur in order to control odor and flies. 8 Animal waste shall not be applied to saturated soils, during rainfall events, or when the surface is frozen. 9of11 NUTRIENT UTILIZATION PLAN REQUIRED SPECIFICATIONS Animal waste shall be applied on actively growing crops in such a manner that the crop is not covered with waste to a depth that would inhibit growth. The potential for salt damage from animal waste should also be considered. 10 Nutrients from waste shall not be applied in fall or winter for spring planted crops on soils with a high potential for leaching. Waste/nutrient loading rates on these soils should be held to a minimum and a suitable winter cover crop planted to take up released nutrients. Waste shall not be applied more than 30 days prior to planting of the crop or forages breaking dormancy. 11 Any new swine facility sited on or after October 1, 1995 shall comply with the following: The outer perimeter of the land area onto which waste is applied from a lagoon that is a component of a swine farm shall be at least 50 feet from any residential property boundary and canal. Animal waste, other than swine waste from facilities sited on or after October 1, 1995, shall not be applied closer than 25 feet to perennial waters. 12 Animal waste shall not be applied closer than 100 feet to wells. 13 Animal waste shall not be applied closer than 200 feet of dwellings other than those owned by the landowner. 14 Waste shall be applied in a manner not to reach other property and public right-of-ways. 15 Animal waste shall not be discharged into surface waters, drainageways, or wetlands by discharge or by over -spraying. Animal waste may be applied to prior converted cropland provided the fields have been approved as a land application site by a "technical specialist". Animal waste shall not be applied on grassed waterways that discharge directly into water courses, and on other grassed waterways, waste shall be applied at agronomic rates in a manner that causes no runoff or drift from the site. 16 Domestic and industrial waste from washdown facilities, showers, toilets, sinks, etc., shall not be discharged into the animal waste management system. 10 of 11 NUTRIENT UTILIZATION PLAN REQUIRED SPECIFICATIONS 17 A protective cover of appropriate vegetation will be established on all disturbed areas (lagoon embankments, berms, pipe runs, etc.). Areas shall be fenced, as necessary, to protect the vegetation. Vegetation such as trees, shrubs, and other woody species, etc., are limited to areas where considered appropriate. Lagoon areas should be kept mowed and accessible. Berms and structures should be inspected regularly for evidence of erosion, leakage, or discharge. 18 If animal production at the facility is to be suspended or terminated, the owner is responsible for obtaining and implementing a "closure plan" which will eliminate the possibility of an illegal discharge, pollution and erosion. 19 Waste handling structures, piping, pumps, reels, etc., should be inspected on a regular basis to prevent breakdowns, leaks and spills. A regular maintenance checklist should be kept on site. 20 Animal waste can be used in a rotation that includes vegetables and other crops for direct human consumption. However, if animal waste is used on crops for direct human consumption, it should only be applied pre -plant with no further applications of animal waste during the crop season. 21 Highly visible markers shall be installed to mark the top and bottom elevations of the temporary storage (pumping volume) of all waste treatment lagoons. Pumping shall be managed to maintain the liquid level between the markers. A marker will be required to mark the maximum storage volume for waste storage ponds. 22 Waste shall be tested within 60 days of utilization and soil shall be tested at least annually at crop sites where waste products are applied. Nitrogen shall be the rate -determining nutrient, unless other restrictions require waste to be applied based on other nutrients, resulting in a lower application rate than a nitrogen based rate. Zinc and copper levels in the soil shall be monitored and alternative crop sites shall be used when these metals approach excessive levels. pH shall be adjusted and maintained for optimum crop production. Soil and waste analysis records shall be kept for a minimum of five years. Poultry dry waste application records shall be maintained for a minimum of three years. Waste application records for all other waste shall be maintained for a minimum of five years. 23 Dead animals will be disposed of in a manner that meets North Carolina regulations. 11 of 11 AWS710096 h II Property Line NRCS Soils Stoneybrook Farm 0 330 660 1,320 Feet NHD Flowline NHD Waterbodv 5707 Willard Rd Watha, NC 28478 Longitude:-78.079844 Latitude: 34.709738 1 in = 0.11 miles 1:7,210 This Map Was Created By Garrett Melvin on 4/29/2015 Using Data From USDA, USGS, NC OneMap, Pander County GIS, NC-DENR, and The Murphy -Brown LLC Engineering Dept. Stone rook Farm AWS71W96 Scale: 1 "=600' Linear — 767' w/86.6' End Gun Radius Total Field 2A = 23.32 Ac. Total Field 2B = 29.59 Ac. Wetted = 18.70 Ac. Wetted = 21.86 Ac. Sub 2A = 4.62 Ac. Sub 28 = 7.73 Ac. Ix Total Field 1 = 2.33 Ac. L1 L2 17.a1 Ac. w/o end gun %'( 21.86 Ac. w/o end gun 18.70 Ac. w/end gun End Gun Runs 88% of Tyne Kr E i F p °.O � p0 Yy0 O �QJ eij T l� Wells <- a W 10�� Total Field 3A = 17.63 Ac. 7^�w Wetted = 13.51 Ac. offsets Hog Houses Sub 3A = 4.12 Ac. 7X Lagoon Linear — 354.3' w/50' End Gun Radius n a :i Total Field 38 = 13.99 Ac. Wetted = 12.28 Ac. Sub 38 = 1,71 Ac. P1 rc c 49 14.09 Ac. w/o End Gun °' o 17.40 Ac. w/End GunM End Gun Runs 52.5R of F on <aUd3 a /9 —KZ' w /90' End Gun Rodiva End Gun Runs 52.5R of Tyne Total Field 4-5 = 30.92 Ac. Wetted = 21.37 Ac. Sub 4-5 = 9.55 Ac. ��cc Specifications: AlN� Traveler w elson 150 w/1.18" nozzle 050 PSI 0p 300' WD; 205 GPM e� °`' 9 220' Lane Spacing 00.291 ` OFS291 s' IN xL�� i 02/01/2017 NUTRIENT UTILIZATION PLAN AMENDMENT Grower(s): Farm Name: Farrow to Wean Farrow to Feeder Farrow to Finish Wean to Feeder Feeder to Finish Wean to Finish Gilts Storage Period: Application Method: Murphy Brown, LLC dba Smithfield Hog Production Stoneybrook, AWS710096 U1111C >180 days Irrigation This amendment allows the producer to plant a small grain crop to be harvested as hay on any of the fields listed in the NUP if desired. The application window for this crop shall be September -April with an application rate of a maximum of 100lbs PAN/ac. Owner/Manager Technical Specialist Date // 7 7aiG Date NUTRIENT UTILIZATION PLAN AMENDMENT Grower(s): Murphy Brown, LLC dba Smithfield Hog Production Division Farm Name: Stoneybrook, AWS710096 County: Pander Farm Caoacitv: Farrow to Feeder Farrow to Finish Wean to Feeder Feeder to Finish Wean to Finish Gilts Storage Period: >180 days Application Method: Irrigation This amendment allows the producer to extend the application window through August 5, 2016 and to apply an additional 40 Ibs PAN/ac to the com at this facility in accordance with the attached agronomist recommendations and plant tissue analysis. G2Ut�9 j�� Owner/Manager Technical Specialist 7-G Loth Date 76 z/ (o Date CAWMP Amendment Farm: Stoneybrook 7/5/16 This amendment calls for an additional 40 units of nitrogen on corn for the Stoneybrook Farm. The corn was planted on May 10, 2016 and is now at the V10 stage of growth. Using tissue samples and applied nitrogen to date it is recommended that an additional 40 units of nitrogen be applied. Nitrogen is accumulated within the corn plant up to physiological maturity. Nitrogen can be applied through the R2 (blister) growth stage of corn and still be utilized by the plant to influence grain yield. Use good judgement regarding pumping and do not pump if soils become saturated. 716116 Manager Date Technical Specialist Date CAWMP AMENDMENT Farm: Stoneybrook 6/24/16 This amendment extends the pumping window on all corn on this farm. Corn was planted on May 10, 2016 on this farm and corn is now at the V9 stage of growth. With the growth stage in mind the pumping window should be extended through August 5, 2016. Nitrogen is accumulated within the corn plant up to physiological maturity. Nitrogen can be applied through the R2 (blister) growth stage of corn and still be utilized by the plant to influence final grain yield, The corn crop on this farm will not be past the R2 growth stage until after August 5, 2016. Use good judgment regarding pumping and do not pump if soils become saturated from rainfall during this extension period. Donor apply more PAN than allowed by the CAWMP. W27116 Date ,�-04ff6 Date NO Customer: 5338 SMTTHFIELD HOG PRODUCTION 677 Curtis Ivey Rd WARSAW, NC 28398 N P K Mg Waters Agricultural Laboratories, Inc. 364 West Park Drive Warsaw, NC 28398 (910) 293-2204 FAX (910) 293-2183 Plant Tissue Analysis Grower: SMITHFIELD HOG PROD FieldlD: STONEYBROOK SamplelD: Li Crop: CORN Plant Lab Results Ca S B "I wt�pravLvt,c� Gvawti� .. Received: 6/30/2016 Processed:7/1/2016 Lab Number: 813375PT Stage: VT (VI-V9) Zn Mn Fe Cu' 2;6 % b.3 % 3.33 % 0.18 % 0.35 % 0.2 % 34.0 PP 79.0 PPm 33 PPm 202 PPm 4.0 ppm NO3 -N: PPm Na: % AI: PPm Mo: PPm Ni: PPm Cl. Plant Rating Excessive High Sufficient Low Deficient N P K Mg Ca S B Zn Mn Fe Cu The following Plant nutrient levels are low, deficient or borderline: Nitrogen -Magnesium - Comments - Apply normal side dress nitrogen application. If side dress application has been applied, apply an additional 30-40 lbs. of nitrogen per acre. Apply 1/2 gallon magnesium chelate or 5 lbs, of magnesium per acre, application should be applied as a foliar spray in a minimum of 25 gallons per acre of water or applied through irrigation. Above applications should be made only if crop is NOT within 30 days of maturity. If more than one foliar application is made, suggest that 1/2 be applied now and 112 5-7 days later. Use only material approved for foliar application. Note: A soil sample was not submitted with plant tissue sample, therefore a thorough analysis is not possible. The results and recommendations are based only on the plant analysis. AT RLA 0 IC RALWN, r (�. Customer: 5338 SMITHFIELD HOG PRODUCTION P.O. BOX 856 677 Curtis Ivey Rd WARSAW, NC 28398 Waters Agricultural Laboratories, Inc. 364 West Park Drive Warsaw, NC 28398 (910) 293-2204 FAX (910) 293-2183 Plant Tissue Analysis Grower: SMITHFIELD HOG PROD FieldID: STONEYBROOK SamplelD: L2 Crop: CORN " I mprovtvt�Growtk.. Processed: 7/1/2016 Lab Number: 813376PT Stage: VT (vl-v9) Plant Lab R6sults N P K Mg Ca S B Zn Mn Fe Cu 2.59 % 0.28 % 2.8 % 0.16 % 0.26 % 0.22 % 22.0 PP 30.0 PPm 26 PPm 241 PPm 7.0 PPm NO3-N: PPm Na: % Al: PPm Mo: PPm Ni: PPm Cl: °/ Plant Rating Excessive High Sufficient Low Deficient N P K Mg Ca S B Zn Mn Fe Cu The following Plant nutrient levels are low, deficient or borderline: Nitrogen-Mag nesiu m- Comments — Apply normal side dress nitrogen application. If side dress application has been applied, apply an additional 30-40 lbs. of nitrogen per acre. — Apply 1/2 gallon magnesium chelate or 5 lbs. of magnesium per acre, application should be applied as a foliar spray in a minimum of 25 gallons per acre of water or applied through irrigation. Above applications should be made only if crop is NOT within 30 days of maturity. If more than one foliar application is made, suggest that 1/2 be applied now and 1/2 5-7 days later. Use only material approved for foliar application. Note: A soil sample was not submitted with plant tissue sample, therefore a thorough analysis is not possible. The results and recommendations are based only on the plant analysis. Waters Agricultural Laboratories, Inc. 364 West Park Drive Warsaw, NC 28398 "Imp rovCYLO-Orowtiv.. (910) 293-2204 FAX (910) 293-2183 141WVSGf.� (L 1 Plant Tissue Analysis customer: o su Grower: SMITHFIELD HOG PROD Received: 6/30/2016 SMITHFIELD HOG PRODUCTION FaIdID: STONEYBROOK Processed: 7/1/2016 P.O. BOX 856 677 Curtis Ivey Rd SamplelD: L3 Lab Number: 813377PT WARSAW, NC 28398 Crop: CORN Stage: VT (V1-Vg) Plant Lab Results N P K Mg Ca S B Zn Mn Fe Cu 2.77 % 1 0.28 % 2.87 % 0.14 % 0.18 % 0.23 % 28.0 PP 25.0 PPm 28 PPm 141 PPm 6.0 ppin NO3-N: PPm Na: % AI: PPm Mo: PPm Ni: PPm Cl. Plant Rating Excessive High Sufficient MEN Low Deficient N P K Mg Ca S B Zn Mn Fe Cu The following Plant nutrient levels are low, deficient or borderline: Nitrogen-Magnesium-Calci u m- Comments — Apply normal side dress nitrogen application. If side dress application has been applied, apply an additional 30-40 lbs. of nitrogen per acre. — Apply 1/2 gallon magnesium chelate or 5 lbs. of magnesium per acre, application should be applied as a foliar spray in a minimum of 25 gallons per acre of water or applied through irrigation. — Apply 400-500 lbs. of gypsum per acre if plant calcium is low and pH is above 6.0 or 1000 Ibs. of liming material if soil pH is below 6.0. Check soil pH for future crops. If foliar application is required apply at a rate of 1 lb. Ca per acre, apply according to product label. Above applications should be made only if crop is NOT within 30 days of maturity. If more than one foliar application is made, suggest that 1/2 be applied now and 112 5-7 days later. Use only material approved for foliar application. Note: A soil sample was not submitted with plant tissue sample, therefore a thorough analysis is not possible. The results and recommendations are based only on the plant analysis. �Wl:%1 OS .ICE RAL Waters Agricultural Laboratories, Inc. 364 West Park Drive Warsaw, NC 28398 "I mpr JVi 1W c7YPWt�'... (910) 293-2204 FAX (910) 293-2183 wxlvsa �' Plant Tissue Analysis Uus[omer: Dojo Grower: SMITHFIELD HOG PROD Received: 6/30/2016 SMITHFIELD HOG PRODUCTION FieldID: STONEYBROOK Processed: 7/1/2016 P.O. BOX 856 677 Curtis Ivey Rd SamplelD: L4 Lab Number: 813378PT WARSAW, NC 28398 Crop: CORN Stage: VT (Vi-V9) Plant Lab Results N P K Mg Ca S B Zn Mn Fe 2.6l % 0.27 % 2.76 %u 0.14 % 0.17 Al% 0.21 % 28.0 PP 20.0 PPm 27 PPm 1 W PPm 6.0 ppm NO3-N: PPm Na: % AI: PPm Mo: Ppm Ni: PPm CI: %' Plant Rating Excessive High Sufficient Low Deficient N P K Mg Ca S B Zn Mn Fe Cu The following Plant nutrient levels are low, deficient or borderline: Nitrogen -Magnesium -Calcium - Comments - Apply normal side dress nitrogen application. If side dress application has been applied, apply an additional 30-40 lbs. of nitrogen per acre. Apply 1/2 gallon magnesium chelate or 5 lbs. of magnesium per acre, application should be applied as a foliar spray in a minimum of 25 gallons per acre of water or applied through irrigation. Apply 400-500 lbs. of gypsum per acre if plant calcium is low and pH is above 6.0 or 1000 lbs. of liming material if soil pH is below 6.0. Check soil pH for future crops. If foliar application is required apply at a rate of 1 lb. Ca per acre, apply according to product label. Above applications should be made only if crop is NOT within 30 days of maturity. If more than one foliar application is made, suggest that 1/2 be applied now and 1/2 5-7 days later. Use only material approved for foliar application. Note: A soil sample was not submitted with plant tissue sample, therefore a thorough analysis is not possible. The results and recommendations are based only on the plant analysis. NUTRIENT UTILIZATION PLAN AMENneeGwr Grower(s): Farm Name: Farrow to Feeder Farrow to Finish Wean to Feeder Feeder to Finish Wean to Finish Gilts Storage Period: Application Method: Murphy Brown, LLC dba Smithfield Hog Production Stoneybrook; AWS710096 >180 days Irrigation This amendment allows the producer to apply to T3247 Field 1. This field is shown on the attached irrigation map and has been utilized in the past for application. The crops, application rates and times are listed in the attached table. Please attach this to the current NUP for this farm. AOwner/Man� Techmca— lS�peci alist Date S /'Al i7 Date Stoneybrook Farm AWS71 W96 Scale: 1'=6W Linear — 767' w/86.6' End Gun Radius Total Field 2A = 23.32 Ac. Total Field 28 = 29.59 Ac. Welted = 18.70 Ac. Wetted = 21.86 Ac. Sub 2A = 4.62 Ac, Sub 2a = 7.73 Ac. Total Field 1 = 2.33 Ac. LI 12 17.01 Ac. w/o end gun EC 21.86 Ac. w/o end gun 18.70 Ac. w/end gun End Gun Rune 88% of Tin4 T V Eb L� p O ob Wells W /100' Total Field 3A = 17.63 Ac. Wetted = 13.51 Ac. offsets Hog Houses Sub 3A = 4.12 Ac. Lagoon Linear — 354.3' w/50' End Gun Radius I d y Total Field 39 = 13.99 Ac, Wetted = 12.28 Ac. Sub 313 = 1.71 Ac. o PI X( £ 14.a9 Ac. W/o End Gun 17.40 Ac /Eno Bun q End Gun Rum 52.5% of n $ ry n �cc F w/90' End GLn Rad'ufv w End W. Run. 525x of rene Total Field 4-5 = 30.92 Ac. Wetted = 21.37 Ac. Sub 4-5 = 9.55 Ac. rys� W S ecification s: •` Al d roveler w Nelson 150 O w/1.18" nozzle ® 50 PSI 2 300' WD; 205 GPM 220' Lone Spacing 002919e ofSIGNFa ' INK1�� 02/01/2017 Address: SR 1101 Checked By: DSE Willard, NC 28478 Date: 09/26/12 County: Pender Sheet 1 of 7 FARM INFORMATION Farm Population: Nursery ------------------ 0 Wean to Finish: ------------------- 0 Finishing: ------------------- 0 Farrow to weanling:------------------- 4000 Hd. Farrow to feeder: ------------------- 0 Farrow to finish: ------------------- 0 Boars: ------------------- 0 Storage Period: ------------------- 180 Days 25 Yr. / 24 Hr Storm Event ------------------- 7.5 In, "Heavy Rain" Factor Rainfall In Excess of Evaporation ------------------- 7.0 In. Additional Water Usage: ------------------- 0 Additional Drainage Area: ------------------- 0 LAGOON INFORMATION Is Lagoon Designed as an Irregular Shape? (Y/N)------------ N Does Operator Want Emergency Spillway? (Y/N)------------ N Was This Design Built Prior to Sept. 1996? (Y/N)------------ Y Is Drain Tile Req'd to Lower SHWT? REQUIREDIII!!!! N Seasonal High Water Table Elev:------------------- 49.50 Ft. Freeboard: ------------------- 1.0 Ft. Emergency Spillway Flow Depth: Side Slopes: ------------------- 3 :1 (H:V) Inside Top Length: 850.0 Ft. Inside Top Width: -- - --- 455.0 Ft. Top of Dike Elevation: ---------------- Depth 53.20 Ft. Finished Bottom Elevation: ---------------- 10.00 Ft. 43.20 Ft. Start Pump Elevation: ---------------- 19.8 In. 51.55 Ft. Stop Pump Elevation: ---------------- 48 In. 49.20 Ft. LAGOON VOLUME REQUIRED VOL. DESIGN VOLUMES % REQ'D. Storm Star = 241719 (Cu.Ft.) 244,358 (Cu.Ft.) 101.09% Temporary = 648570 (Cu.Ft.) 857,959 (Cu.Ft.) 132.28% Permanent = 1732000 (Cu.Ft.) 2,003,511 (Cu.Ft.) 115.68% Total Volume = 2,622,289 (Cu.Ft.) 3,105,827 (Cu.Ft.) 118.44% 112 Treatment Volume = 866,000 (Cu.Ft.) 1/2 Treatment Volume Elevation = 46.70 Ft. 90 Temporary Storage Volume Elevation = 50.37 Ft. Min. Required Liner Thickness Lagoon Surface Area: (Inside TOD) 77.98 In. 33.91 In. 1.5 Ft. 386,750 S.F. Murphy -Brown, LLC Engineering P.O. Box 856,Warsaw, NC 28398 (910) 293-3434 You created this PDF from an application that is not licensed to print to novaPDF printer (h!!p://www.novapgf.com) Address: SR 1101 Willard, NC 28478 County: Pender `Vo IiJlmu Dy. Checked By: Date: Sheet 2 of 7 rNbVV DSE 09/26/12 ACTUAL DESIGN VOLUME CALCULATIONS BASE VOLUME: Cu. Ft, LAGOON STAGE -AREA VOLUMES Contour Elevation (FT) Area SF Incr. Vol (Cu FT) Cumul. Vol (Cu FT) 43.20 312,050 0 44.00 45.00 317,761 324,965 251,924 251,924 46.00 332,240 321,363 328,602 573,287 901,890 47.00 48.00 339,588 335,914 1,237,804 49.00 347,007 354,499 343,298 350,753 1,581,101 50.00 362,063 358,281 1,931,855 2,290,135 51.00 52.00 369,698 377.406 365,880 2,656,016 53.00 385,185 373,552 381,296 3,029,568 3,410,864 53.20 386,750 77,194 3,488,057 These volumes were calculated using the vertical aver a a end area method. TOTAL READ VOL 2,622,289 CF CUMULATIVE VOL. ZONE VOL. 118.44% END PUMP = _ _ = START PUMP = _ : 49.20 FT 51.55 2,003,511 CF TR'MT 2,003,511 115.680/, MAX STORAGE = FT 52.20 FT 2,861,470 CF 3,105,827 CF TEMP 857,959 STORM 944,358 132.28% 101.09o, Murphy -Brown, LLC Engineering P.O. Box 856, Warsaw, NC 28398 (919) 293-3434 You created this PDF from an application that is not licensed to print to novaPDF printer (htfp:/lwww.novapdf_com) oioneybrook Sow Farm Address: SR 1101 Willard, NC 28478 County: Pander MINIMUM REQUIRED VOLUME CALCULATIONS Permanent Storage. Required Treatment Volume Sludge TemDOraa[Storage Volumes Manure Production: Checked By: Date: Sheet 3 of 7 422,966 Excess Fresh Water: nima ype Nursery r„ to reriog d igay) Total Wean to Finish 0 180 0.00 0 Finishing 0 180 0.00 0 Farrow to weanling 180 0.00 0 Farrow to feeder 4,000 180 0.00 p Farrow to finish 0 180 0.00 0 Boars 0 180 0.00 0 0 180 Total Fresh Water Excess (gals.)= 0.00 0 Total Fresh Water Excess (cu.ft.)= 0 0 DSE 03/26/19 a Designed By: KBW Address: SR 1101 Checked By: DSE Willard, NC 28478 Date: 03/26/19 County: Pender Sheet 4 of 7 Temporary Storage Volume: (Cont.) Rainfall in Excess of Evaporation: Vol.=(Lagoon Surface Area + Additional Drainage Area) * Rainfall / 12in./ft Vol.= (386750 sq.ft. + 0 sq.ft.) * 7 in. /12 in./ft. Total Required Volume for Rainfall in Excess of Evap. (cu.ft.)= Storm Storage: Vol.=(Lagoon Surf. Area + Addt'I Drainage Area) * 25Yr./24Hr. Storm(in) / 12in./ft. Vol.= (386750 sq.ft + 0 sq.ft.) * 7.5 in. /12 in./ft. Total Required Volume for 25Yr./24Hr. Storm Event (cu.ft)= "Heavy Rain" Storage: Vol.=(Lagoon Surf. Area + Addt'I Drainage Area) * "Heavy Rain" Factor (in) / 12in./ft. Vol.= (386750 sq.ft + 0 sq.ft.) * 0.0 in. /12 in./ft. Total Required Volume for "Heavy Rain" (cu.ft.) _ (for Extended Periods of Chronic Rainfall) Additional Water Storage: No Additional Water Storage is Required 226,604 241,719 Total Required Storm Storage (25Yr. / 2411r. Storm +'Heavy Rain')= 241,719 (CU.FT) Total Required Temporary Storage (Manure Prod. + Excess Fr. Water + Rainfall Excess + Additional Water Storage) = 648,570 (CU.FT) Total Required Permanent Storage (Treatment + Sludge) = 1,732,000 (CU.FT) TOTAL REQUIRED VOLUME = 2622289 (CU.FT.) uiuwer. stoneybrook Sow Farm Designed By: KgW Address: SR 1101 Checked By: DSE Willard, NC 28478 Date: 03/26/19 County: Pender Sheet 5 of 7 LAGOON DESIGN SUMMARY Top of Dike Elevation ------------------- Emergency Spillway Crest Elevation 53.20 FT. Top of 25Yr. / 24Hr. Storm Storage ___________________ Not AfApplicable Top of "Heavy Rain" Storage ---------- 52.20 FT. Start Pump Elevation Not Applicable End Pump Elevation 51.55 FT. Top of Sludge Storage ------------------- 49.20 FT. Seasonal High Watertable Elev. __--___-___ Not Applicable Finished Bottom Elevation 49.50 FT. Inside Top Length -_--- --------- 43.20 FT. Inside Top Width ______ ----------- 850.00 FT. - Side Slopes ------------------- 455.00 FT. Lagoon Surface Area 3:1 H:V Min. Liner Thickness (if required) ___________________ 386,750 SF Freeboard Depth 1.5 FT. Temporary Storage Period _________ 1.00 FT. 180 Days TOTAL DESIGN VOLUME = 3105827 (CU.FT.) Zone Depths: Treatment / Sludge Storage Zone Depth ----------- Temporary Storage Zone Depth 6.0 FT. Freeboard /Storm Storage Zone Depth ----------- 2.3 FT. Total Lagoon Depth 1.7 FT. 10.0 FT. Grower: Stoneybrook Sow Farm Designed By: KBW Address: SR 1101 Checked By: DSE Willard, NC 28478 Date: 03/26/19 County: Pander Sheet 7 of 7 This livestock waste treatment lagoon is designed in accordance with the United States Natural Resources Conservation Service PRACTICE STANDARD 359- WASTE TREATMENT LAGOON, revised prior to June, 1996. Emergency Spillway: An Emergency Spillway is not required. NOTE: See attached Waste Utilization Plan DESIGNED: DATE- COMMENTS - This design is update of start and stop pump elevations and to show the 1/2 treatment volume level for sludge storage. This design does not supercede the original certification of the farm. Murphy -Brown, LLC Engineering P.O. Box 856, Warsaw NC 28398 (910) 293-3434 Address: SR 1101 Checker DSE Willard, NC 28478 Date: 03/26/19 County: Pander Sheet 6 of 7 STRT PMP EL.= 51.55 END PMP EL. =49.20 Murphy -Brown, ZONE ELEVATIONS TOP OF DIKE ELEV = 53.20 TOP OF STORM ELEV = 52.20 TOP OF TEMP STORAGE ELEV = 51.55 \ TOP OF TREAT ELEV = 49.20 1 FINISHED BOTTOM ELEV = 43.20 Warsaw NC SHWT = 49.50 rRyrr System Calibration Information presented in manufacturer's charts are based on average operation conditions with relatively new equipment. Discharge rates and application rates change over time as equipment gets older and components wear. In particular, pump wear tends to reduce operating pressure and flow. With continued use, nozzle wear results in an increase in the nozzle opening which will increase the discharge rate while decreasing the wetted diameter. You should be aware that operating the system differently than assumed in the design will alter the application rate, diameter of coverage, and subsequently the application uniformity. For example, operating the system with excessive pressure results in smaller droplets, greater potential for drift, and accelerates wear of the sprinkler nozzle. Clogging of nozzles can result in pressure increase. Plugged intakes or crystallization of mainlines will reduce operating pressure. Operating below design pressure greatly reduces the coverage diameter and application uniformity. For the above reason, you should calibrate your equipment on a regular basis to ensure proper application rates and uniformity. Calibration at least once every three years is recommended. Calibration involves collecting and measuring flow at several locations in the application area. Any number of containers can be used to collect flow and determine the application rate. Rain gauges work best because they already have a graduated scale from which to read the application amount without having to perfo transferred to a scaled container for measuring. rm additional calculations. However, pans, plastic buckets, jars, or anything with a uniform opening and cross-section can be used provided the liquid collected can be easily For stationary sprinklers, collection containers should be located randomly throughout the application area at several distances from sprinklers. For traveling guns, sprinklers should be located along a transect perpendicular to the direction of pull. Set out collection containers 25 feet apart along the transect on both sides of the gun cart. You Should compute the average application rate for all nonuniformity of the application. On a windless day, variation between containers of more than 30 percent is cause for concern. You should contact your irrigation dealer or technical specialist for assistance. 'Reprinted for Certification Training for Operations of Animal Waste Management Systems Manual OPERATION & MAINTENANCE PLAN Proper lagoon management should be a year-round priority. It is especially important to manage levels so that you do not have problems during extended rainy and wet periods. Maximum storage capacity should be available in the lagoon for periods when the receiving crop is dormant (such as wintertime for bermudagrass) or when there are extended rainy spells such as a thunderstorm season in the summertime. This means that at the first sign of plant growth in the later winter / early spring, irrigation according to a farm waste management plan should be done whenever the land in dry enough to receive lagoon liquid. This will make storage space available in the lagoon for future wet periods. In the late summer / early fall the lagoon should be pumped down to the low marker (see Figure 2-1) to allow for winter storage. Every effort should be made to maintain the lagoon close to the minimum liquid level as long as the weather and waste utilization plan will allow it. Waiting until the lagoon has reached its maximum storage capacity before starting to irrigated does not leave room for storing excess water during extended wet periods. Overflow from the lagoon for any reason except a 25-year, 24-hour storm is a violation of state law and subject to penalty action. The routine maintenance of a lagoon involves the following: Maintenance of a vegetative cover for the dam. Fescue or common bermudagrass are the most common vegetative covers. The vegetation should be fertilized each f should be based ton aasoils testvb t in the tevent that it isand. The notpracticalzto obtaiunt of fertilied ln a soils test each year, the lagoon embankment and surrounding areas should be fertilized with 800 pounds per acre of 10-10-1o, or equivalent. Brush and trees on the embankment must be controlled. This may be done by mowing, spraying, grazing, chopping, or a combination of these practices. This should be done at least once a year and possibly twice in years that weather conditions are favorable for heavy vegetative growth. NOTE: If vegetation is controlled by spraying, the herbicide must not be allowed to enter the lagoon water. Such chemicals could harm the bacteria in the lagoon that are treating the waste. Maintenance inspections of the entire lagoon should be made during the initial filling of the lagoon and at least monthly and after major rainfall and storm events. Items to be checked should include, as a minimum, the following: Waste Inlet Pipes, Recycling Pipes, and Overflow Pipes -- look for: 1. separation of joints 2. cracks or breaks 3. accumulation of salts or minerals 4. overall condition of pipes Lagoon surface -- look for: 1. undesirable vegetative growth 2. floating or lodged debris Embankment -- look for: 1. settlement, cracking, or "jug" holes 2. side slope stability -- slumps or bulges 3. wet or damp areas on the back slope 4. erosion due to lack or vegetation or as a result of wave action 5. rodent damage Larger lagoons may be subject to liner damage due to wave action caused by strong winds. These waves can erode the lagoon sidewalls, thereby weakening the lagoon dam. A good stand of vegetation will reduce the potential damage caused by wave action. If wave action causes serious damage to a lagoon sidewall, baffles in the lagoon may be used to reduce the wave impacts. Any of these features could lead to erosion and weakening of the dam. If your lagoon has any of these features, you should call an appropriate expert familiar with design and construction of waste lagoons. You may need to provide a temporary fix if there is a threat of a waste discharge. However, a permanent solution should be reviewed by the technical expert. Any digging into a lagoon dam with heavy equipment is a serious undertaking with potentially serious consequences and should not be conducted unless recommended by an appropriate technical expert. Transfer Pumps -- check for proper operation of: 1. recycling pumps 2. irrigation pumps Check for leaks, loose fittings, and overall pump operation. An unusually loud or grinding noise, or a large amount of vibration, may indicate that the pump is in need of repair or replacement. NOTE: Pumping systems should be inspected and operated frequently enough so that you are not completely "surprised" by equipment failure. You should perform your pumping system maintenance at a time when your lagoon is at its low level. This will allow some safety time should major repairs be required. Having a nearly full lagoon is not the time to think about switching, repairing, or borrowing pumps. Probably, if your lagoon is full, your neighbor's lagoon is full also. You should consider maintaining an inventory of spare parts or pumps. • Surface water diversion features are designed to carry all surface drainage waters (such as rainfall runoff, roof drainage, gutter outlets, and parking lot runoff) away from your lagoon and other waste treatment or storage structures. The only water that should be coming from your lagoon is that which comes from your flushing (washing) system pipes and the rainfall that hits the lagoon directly. You should inspect your diversion system for the following: 1. adequate vegetation 2. diversion capacity 3. ridge berm height 3 Identified problems should be corrected promptly. It is advisable to inspect your system during or immediately following a heavy rain. If technical assistance is needed to determine proper solutions, consult with appropriate experts. You should record the level of the lagoon just prior to when rain is predicted, and then record the level again 4 to 6 hours after the rain (assumes there is no pumping). This will give you an idea of how much your lagoon level will rise with a certain rainfall amount (you must also be recording your rainfall for this to work). Knowing this should help in planning irrigation applications and storage. If your lagoon rises excessively, you may have an overflow problem from a surface water diversion or there may be seepage into the lagoon from the surrounding land. Lagoon Operation Startup: 1. Immediately after construction establish a complete sod cover on bare soil surfaces to avoid erosion. 2. Fill new lagoon design treatment volume at least half full of water before waste loading begins, taking care not to erode lining or bank slopes. 3. Drainpipes into the lagoon should have a flexible pipe extender on the end of the pipe to discharge near the bottom of the lagoon during initial filling or another means of slowing the incoming water to avoid erosion of the lining. 4. When possible, begin loading new lagoons in the spring to maximize bacterial establishment (due to warmer weather). 5. It is recommended that a new lagoon be seeded with sludge from a healthy working swine lagoon in the amount of 0.25 percent of the full lagoon liquid volume. This seeding should occur at least two weeks prior to the addition of wastewater. 6. Maintain a periodic check on the lagoon liquid pH. If the pH falls below 7.0, add agricultural lime at the rate of 1 pound per 1000 cubic feet of lagoon liquid volume until the pH rises above 7.0. Optimum lagoon liquid pH is between 7.5 and 8.0. 7. A dark color, lack of bubbling, and excessive odor signals inadequate biological activity. Consultation with a technical specialist is recommended if these conditions occur for prolonged periods, especially during the warm season. Loading: The more frequently and regularly that wastewater is added to a lagoon, the better the lagoon will function. Flush systems that wash waste into the lagoon several times daily are optimum for treatment. Pit recharge systems, in which one or more buildings are drained and recharged each day, also work well. M • Practice water conservation --- minimize building water usage and spillage from leaking waterers, broken pipes and washdown through proper maintenance and water conservation. • Minimize feed wastage and spillage by keeping feeders adjusted. This will reduce the amount of solids entering the lagoon. Management: • Maintain lagoon liquid level between the permanent storage level and the full temporary storage level. • Place visible markers or stakes on the lagoon bank to show the minimum liquid level and the maximum liquid level. (Figure 2-1). • Start irrigating at the earliest possible date in the spring based on nutrient requirements and soil moisture so that temporary storage will be maximized for the summer thunderstorm season. Similarly, irrigate in the late summer / early fall to provide maximum lagoon storage for the winter. • The lagoon liquid level should never be closer than 1 foot to the lowest point of the dam or embankment. • Don not pump the lagoon liquid level lower than the permanent storage level unless you are removing sludge. • Locate float pump intakes approximately 18 inches underneath the liquid surface and as far away from the drainpipe inlets as possible. • Prevent additions of bedding materials, long-stemmed forage or vegetation, molded feed, plastic syringes, or other foreign materials into the lagoon. • Frequently remove solids from catch basins at end of confinement houses or wherever they are installed. • Maintain strict vegetation, rodent, and varmint control near lagoon edges. • Do not allow trees or large bushes to grow on lagoon dam or embankment. • Remove sludge from the lagoon either when the sludge storage capacity is full or before it fills 50 percent of the permanent storage volume. • If animal production is to be terminated, the owner is responsible for obtaining and implementing a closure plan to eliminate the possibility of a pollutant discharge. Sludge Removal: Rate of lagoon sludge buildup can be reduced by: 5 • proper lagoon sizing, • mechanical solids separation of flushed waste, • gravity settling of flushed waste solids in an appropriately designed basin, or • minimizing feed wastage and spillage. Lagoon sludge that is removed annually rather than stored long term will: • have more nutrients, • have more odor, and • require more land to properly use the nutrients. Removal techniques: • Hire a custom applicator. • Mix the sludge and lagoon liquid with a chopper - agitator impeller pump through large - bore sprinkler irrigation system onto nearby cropland; and soil incorporate. • Dewater the upper part of lagoon by irrigation onto nearby cropland or forageland; mix remaining sludge; pump into liquid sludge applicator; haul and spread onto cropland or forageland; and soil incorporate. • Dewater the upper part of lagoon by irrigation onto nearby cropland or forageland; dredge sludge from lagoon with dragline or sludge barge; berm an area beside lagoon to receive the sludge so that liquids can drain back into lagoon; allow sludge to dewater; haul and spread with manure spreader onto cropland or forageland; and soil incorporate. Regardless of the method, you must have the sludge material analyzed for waste constituents just as you would your lagoon water. The sludge will contain different nutrient and metal values from the liquid. The application of the sludge to fields will be limited by these nutrients as well as any previous waste applications to that field and crop requirement. Waste application rates will be discussed in detail in Chapter 3. When removing sludge, you must also pay attention to the liner to prevent damage. Close attention by the pumper or drag -line operator will ensure that the lagoon liner remains intact. If you see soil material or the synthetic liner material being disturbed, you should stop the activity immediately and not resume until you are sure that the sludge can be removed without liner injury. If the liner is damaged it must be repaired as soon as possible. Sludge removed from the lagoon has a much higher phosphorus and heavy metal content than liquid. Because of this it should probably be applied to land with low phosphorus and metal levels, as indicated by a soil test, and incorporated to reduce the chance of erosion. Note that if the sludge is applied to fields with very high soil -test phosphors, it should be applied only at rates equal to the crop removal of phosphorus. As with other wastes, always have your lagoon sludge analyzed for its nutrient value. The application of sludge will increase the amount of odor at the waste application site. Extra precaution should be used to observe the wind direction and other conditions which could increase the concern of neighbors. Possible Causes of Lagoon Failure Lagoon failures result in the unplanned discharge of wastewater from the structure. Types of failures include leakage through the bottom or sides, overtopping, and breach of the dam. Assuming proper design and construction, the owner has the responsibility for ensuring structure safety. Items which may lead to lagoon failures include: • Modification of the lagoon structure -- an example is the placement of a pipe in the dam without proper design and construction. (Consult an expert in lagoon design before placing any pipes in dams.) • Lagoon liquid levels — high levels are a safety risk. • Failure to inspect and maintain the dam. • Excess surface water flowing into the lagoon. • Liner integrity -- protect from inlet pipe scouring, damage during sludge removal, or rupture from lowering lagoon liquid level below groundwater table. NOTE: If lagoon water is allowed to overtop the dam, the moving water will soon cause gullies to form in the dam. Once this damage starts, it can quickly cause a large discharge of wastewater and possible dam failure. EMERGENCY ACTION PLAN PHONE NUMBERS DIVISION OF WATER QUALITY (DWQ) EMERGENCY MANAGEMENT SERVICES (EMS) qto - asp- lala SOIL AND WATER CONSERVATION DISTRICT (SWCD) a t0 - a g -Ctk NATURAL RESOURCES CONSERVATION SERVICE (NRCS) COOPERATIVE EXTENSION SERVICE (CES) 2l0 — This plan will be implemented in the event that wastes from your operation are leaking, overflowing or running off site. You should not wait until wastes reach surface waters or leave your property to consider that you have a problem. You should make every effort to ensure that this does not happen. This plan should be posted in an accessible location for all employees at the facility. The following are some action items you should take. 1. Stop the release of wastes. Depending on the situation, this may or may not be possible. Suggested responses to some possible problems are listed below. A. Lagoon overflow - possible solutions are: a) Add soil to berm to increase elevation of dam. b) Pump wastes to fields at an acceptable rate. c) Stop all flow to the lagoon immediately. d) Call a pumping contractor. e) Make sure no surface water is entering lagoon. B. Runoff from waste application field -actions include: a) Immediately stop waste application. b) Create a temporary diversion to contain waste. C) Incorporate waste to reduce runoff. d) Evaluate and eliminate the reason(s) that cause the runoff. e) Evaluate the application rates for the fields where runoff occurred. C. Leakage from the waste pipes and sprinklers - action include: a) Stop recycle pump. b) Stop irrigation pump. C) Close valves to eliminate further discharge. d) Repair all leaks prior to restarting pumps. D. Leakage from flush systems, houses, solid separators - action include: a) Stop recycle pump. b) Stop irrigation pump. c) Make sure siphon occurs. d) Stop all flow in the house, flush systems, or solid separators. E. Leakage from base or sidewall of lagoon. Often this is seepage as opposed to flowing leaks - possible action: a) Dig a small sump or ditch from the embankment to catch all seepage, put in a submersible pump, and pump back to lagoon. b) If holes are caused by burrowing animals, trap or remove animals and fill holes and compact with a clay type soil. c) Have a professional evaluate the condition of the side walls and the lagoon bottom as soon as possible. 2. Assess the extent of the spill and note any obvious damages. a. Did the waste reach surface waters? b. Approximately how much was released and for what duration? c. Any damage notes, such as employee injury, fish kills, or property damage? d. Did the spill leave the property? e. Does the spill have the potential to reach surface waters? f. Could a future rain event cause the spill to reach surface waters? g. Are potable water wells in danger (either on or off the property)? h. How much reached surface waters? 3. Contact appropriate agencies. a. During normal business hours call your DWQ regional office; Phone #, After hours, emergency number: (919) 733-3942. Your phone call should include: your name, facility number, telephone number, the details of the incident from item 2 above, the exact location of the facility, the location or direction of the movement of the spill, weather and wind conditions. The corrective measures that have been under taken, and the seriousness of the situation. b. If the spill leaves property or enters surface waters, call local EMS phone number. c. Instruct EMS to contact local Health Department. d. Contact CE's phone number, local SWCD office phone number and the local NRCS office for advice / technical assistance phone number. 4. If none of the above works call 911 or the Sheriff's Department and explain your problem to them and ask the person to contact the proper agencies for you. 5. Contact the contractor of your choice to begin repair or problem to minimize offsite damage. a. Contractors Name: Murphy Brown LLC b. Contractors Address: P.O. Box 856 Warsaw NC 28398 c . Contractors Phone: (910)293-3434 6. Contact the technical specialist who certified the lagoon (NRCS, Consulting Engineer, etc.) a. Name: Kraig Westerbeek b. Phone: (910) 293 - 5330 Implement procedures as advised by DWQ and technical assistance agencies to rectify the damage, repair the system, and reassess the waste management plan to keep problems with release of wastes from happening again. INSECT CONTROL CHECKLIST FOR ANIMAL OPERATIONS Source Cause BMP's to Minimize Odor Site Specific Practices Hccumwation of solids (✓) Flush system is designed and operated sufficiently to remove accumulated solids from gutters as designed. () Remove bridging of accumulated solids at discharge Lagoons and Pits Crusted Solids (✓) Maintain lagoons, settling basins and Pits where pest breeding is apparent to minimize the crusting of solids to a depth of no more than 6-8 inches over more than 30% of surface. cxcessrve Uecaying vegetation (✓)Maintain vegetative control along banks of Vegetative Growth lagoons and other impoundment's to prevent accumulation of decaying vegetative matter along waters edge on impoundment's perimeter. (Dry Systems) Feeders Feed Spillage () Design, operate and maintain feed systems (e.g., bunkers and troughs) to minimize the accumulation of decaying wastage. () Clean up spillage on a routine basis (e.g. 7-10 day interval during summer; 15-30 day interval during winter). Feed Storage Accumulation of feed () Reduce moisture accumulation within and around residues immediate perimeter of feed storage areas by insuring drainage away from site and/or providing adequate containment (e.g., covered bin for brewers grain and similar high moisture grain products). () Inspect for and remove or break up accumulated solids in filter strips around feed storage as needed. Animal Holding Accumulation of animal Areas () Eliminate low area that trap moisture along fences wastes and feed wastage and other locations where waste accumulates and disturbance by animals is minimal. () Maintain fence rows and filter strips around animal holding areas to minimize accumulations of wastes (i.e. inspect for and remove or break up accumulated solids as needed). MIC — November 11, 1996 10 Dry Manure Handling Accumulations of animal Systems wastes () Remove spillage on a routine basis inter al d day interval during summer; 15-30 days interval during winter) where manure is loaded for land application or disposal. () Provide for adequate drainage around manure stockpiles () Inspect for and remove or break up accumulated wastes in filter strips around stockpiles and manure handling areas as needed. The issues checked () pertain to this operation. The landowner / integrator agrees to use sound judgment in applying insect control measures as practical. I certify the aforementioned insect control Best Management Practices have been reviewed with me. hLr (Landowner Signature For more information contact the Cooperative Extension Service, Department of Entomology, Box 7613, North Carolina State University, Raleigh, NC 27695-7613. AMIC -- November 11, 1996 SWINE FARM WASTE MANAGEMENT ODOR CONTROL CHECKLIST Source Cause BMP's to Minimize Odor Site Specific Practices Farmstead Swine production (-)Vegetative or wooded buffers: (V)Recommended best management practices; (V)Good judgment and common sense Animal body Dirty manure surfaces covered animals Floor surfaces Wet manure -covered (✓)Slotted floors; floors (V)Waterers located over slotted floors; (V)Feeders at high end of solid floors; (✓)Scrape manure buildup from floors; ( )Underfloor ventilation for drying Manure collection Urine (,')Frequent manure removal by flush, pit pits recharge or scrape Partial microbial ( )Underfloor ventilation decomposition Ventilation Volatile gases (V)Fan maintenance; exhaust fans Dust (✓)Efficient air movement Indoor surfaces Dust (✓)Washdown between groups of animals ( )Feed additives; ( )Feeder covers; ( )Feed delivery downspout extenders to feeder covers Flush Tanks Agitation of recycled ( )Flush tank covers lagoon liquid while tanks ( )Extend fill lines to near bottom of tanks are filling with anti -siphon vents Flush alleys Agitation during waste ( )Underfloor flush with underfloor water conveyance ventilation Pit recharge Agitation of recycled ( )Extend recharge lines to near bottom of points lagoon liquid while pits pits with anti -siphon vents are filling Lift stations Agitation during sump ( )Sump tank covers tank filling and drawdown Outside drain Agitation during waste ( )Box Covers collection or water conveyance junction boxes End of drain Agitation during waste ( )Extend discharge point of pipes pipes at lagoon water underneath lagoon liquid level Lagoon surfaces Volatile gas emissions (✓)Proper lagoon liquid capacity Biological mixing (,)Correct lagoon startup procedures Agitation ( )Minimum surface area -to -volume ratio (V)Minimum agitation when pumping ( )Mechanical aeration ( )Proven biological additives Irrigation sprinkler High pressure agitation (V)Irrigate on dry days with little or no wind nozzles Wind draft (V)Minimum recommended operation pressure (V)Pump intake near lagoon liquid surface ( )Pump from second -stage lagoon AMOC — November 11, 1996 12 Storage tank or Partial microbial ( )Bottom or midlevel loading basin surface decomposition Mixing while ( )Tank covers filling Agitation when emptying( )Basin surface mats of solids ( )Proven biological additives or oxidants Settling basin Partial microbial decom- ( )Extend drainpipe outlets underneath liquid surface position Mixing while filling level Agitation when emptying ( )Remove settled solids regularly _ Manure, slurry or Agitation when spreading ( )Soil injection of slurry/sludges sludge spreader Volatile gas emissions ( )Wash residual manure from spreader after use outlets ( )Proven biological additives or oxidants Dead animals Carcass decomposition ( )Proper disposition of carcasses Dead animal Carcass decomposition ( )Complete covering of carcasses in burial pits disposal pits ( )Proper location / construction of disposal pits Incinerators Incomplete combustion ( )Secondary stack burners Standing water improper drainage (V)Farm access road maintenance around facilities Microbial decomposition of away from facilities organic matter Manure tracked Poorly maintained access (v)Farm access road maintenance onto public roads roads from farm access Additional Information: Available From: Swine Manure Management 0200 Rule / BMP Packet NCSU-County Extension Center Swine Production Farm Potential Odor Sources and Remedies, EBAE Fact Sheet NCSU-BAE Swine Production Facility Manure Management:Pit Recharge --Lagoon Treatment:EBAE128-88NCSU-BAE Swine Production Facility Manure Management:Underfloor Fluse-Lagoon Treatment 129-88NCSU-BAE Lagoon Design and Management for Livestock Manure Treatment and Storage; EBAE103-83NCSU-BAE Calibration of Manure and Wastewater Application Equipment EBAE Fact Sheet NCSU-BAE Controlling Odors from Swine Buildings; PIH-33 NCSU-Swine Extension Environmental Assurance Program: NPPC Manual NC Pork Producers Assoc Options for Managing Odor; a report from the Swine Odor Task Force NCSU Agri Communication Nuisance Concerns in Animal Manure Management: Odors and Flies; PR0101, Florida Cooperative Extension 1995 Conference Proceedings The issues checked ( ) pertain to this operation. The landowner / integrator agrees to use sound judgment in applying odor control measures as practical. I certify the aforementioned odor control Best Management Practices have been reviewed with me. Wig — r (Landowner Signature) 13 MORTALITY MANAGEMENT METHODS (Check which method(s) are being implemented) ( ) Burial three feet beneath the surface of the ground within 24 hours after knowledge of the death. The burial will be at least 300 feet from any flowing stream or public body of water. (✓ ) Rendering at a rendering plant licensed under G. S. 106 - 168.7 ) Complete incineration In the case of dead poultry only, placing in a disposal pit of a size and design approved by the Department of Agriculture. Any method which in the professional opinion of the State Veterinarian would make possible the salvage of part of a dead animal's value without endangering human or animal health. (Written approval of the State Veterinarian must be attached) 14 Steven W. Troxler Commissioner Mr. Ray Cooke Murphy Brown LLC 785 NC 24/50 East Warsaw, NC 28398 910-935-0070 - Cell Dear Mr. Cooke: Ed��cuiru�KQ y �ji F a .ltmumian. North Carolina Department of Agriculture and Consumer Services Veterinary Division May 22, 2014 Swine Farm 911 Address: Stoneybrook Farm 5707 Willard Road Willard, NC 28478 Pender County State ID: 556017228 National ID: 007TMCS David T. Marshall, DVM State Veterinarian Pursuant to NCAC 52C.0102, your request to compost swine mortality on your premises at 5707 Willard Road, Willard, NC in Pender County is approved. Approval is granted under the following conditions and stipulations: 1. All North Carolina solid waste, air, water quality, and other applicable regulations must be met in siting and operation of the system 2. Only poultry or swine are to be processed in this facility; NO bovine, caprine, ovine or cervid species shall be processed 3. Mortality to be processed shall originate only from the identified premises and the finished product is used solely on agricultural operations owned, operated, or leased, by the permitee 4. The final product of the process must be stored, treated and utilized in accordance with all federal, state, and local laws, regulations, and permit requirements; the final product shall not be sold 5. Temperatures shall be within NRCS guidelines to reach a minimum of 131 degrees F within 5 days of filling the unit and remain at least at 131 degrees F for a minimum of 5 consecutive days to maintain the composting process and reduce pathogen load 6. Dead animals are not to be removed from composting until all flesh, internal organs, and other soft tissue are fully decomposed 7. The proposed facility shall have the following minimum setback requirements*: • The 100-foot buffer between all property lines and composter areas has been amended to 84 +/- feet for this composter facility due to a grandfathering exemption from NCDA&CS, Veterinary Division under the original permit issued for this composter facility in 2006 • 100-foot buffer between all wells and compost areas, except for monitoring wells • 50-foot buffer between perennial streams/rivers and compost areas • 200-foot buffer between dwellings and compost areas as long as the facility is considered a Small Type 3 facility (less than 1000 cubic yards material handled per quarter)** 1. A copy of the permit, plans, and operational reports shall be maintained on site and be available upon request by NCDA&CS, Veterinary Division personnel 1030 Mail Service Center, Raleigh, North Carolina 27699.1030 • (919) 733-7601 An Equal Opportunity Affirmative Action Employer 2. The facility and operational records shall be available for annual inspection by Veterinary Division personnel and shall be sent to the Veterinary Division upon request 3. Operational reports shall include temperature monitoring during initial facility start-up and follow- up records that contain either 10 days/month or annual laboratory results of pathogen load testing 4. An application for a permit modification shall be required for changes in facility ownership, an increase in facility capacity, or any other changes from the stipulations of this permit 5. The Veterinary Division must be immediately notified of any complicating issues involving animal disease or environmental concerns 6. The State Veterinarian reserves the right to cancel this permit if a specific concern for controlling animal disease arises, or if any of the aforementioned conditions are not met. This document shall in no circumstances be interpreted as an endorsement of any specific manufacturer or type of mortality management system by the State Veterinarian and the Office of the State Veterinarian does not approve or disapprove the technical or performance standards for specific makes or designs of equipment. *Additional requirements and regulations will apply from DENR, Division of Solid Waste Management if application for off -farm disposition of composted material is requested (see G.S. 130A-309.29 and ISA NCAC 13B, Section .1400 **If greater than 1000 cubic yards of composted material is handled in the facility per quarter, a setback from residences of 500 feet is required Sincerely, �T Dr. Tom Ray, DVM, MPH Director of Animal Health Programs/Livestock cc: Dr. David Marshall, State Veterinarian Dr. Sarah Mason, Director, AHP-Poultry Dr. Betty Herring, Veterinary Medical Officer Mr. Keith Warren, Advanced Composting Technologies Ms. Becky Hagan, Advanced Composting Technologies Insect Control Checklist for Animal Operations Source Cause BMPs to Control Insects Site Specific Practices Flush gutters • Accumulation of solids a Flush system is designed and operated sufficiently to remove accumulated solids from gutters as designed Remove bridging of accumulated solids at Lagoons and pits • Crusted solids Maintain lagoons, settling basins and pits where Ej pest breeding is apparent to minimize the crusting of solids to a depth of no more than 6 to 8 inches over more than 30 percent of surface Excessive vegetative • Decaying vegetation Maintain vegetative control along banks of growth lagoons and other impoundments to prevent accumulation of decaying vegetative matter along water's ed eon im oundment's erimeter. Feeders • Feed spillage ❑ Design, operate, and maintain feed systems (e.g., bunkers and troughs) to minimize the accumulation of decaying wastage ❑Clean up spillage on a routine basis (e.g., 7- to 10-day interval during summer; 15- to 30-day interval during winter) AMIC — November 11, 1996, page 1 Insect Control Checklist for Animal Operations Source Cause BMPs to Control Insects Site Specific Practices Feed storage . Accumulations of feed residues I I Reduce moisture accumulation within and around immediate perimeter of feed storage areas by ensuring drainage is away from site and/or providing adequate containment (e.g., covered bin for brewer's grain and similar high moisture grain products) Inspect for and remove or break up accumulated solids in filter strips around feed storage as Animal holding areas . Accumulations of animal wastes Eliminate low areas that trap moisture along and feed wastage F_X1 fences and other locations where waste accumulates and disturbance by animals is minimal ElMaintain fence rows and filter strips around animal holding areas to minimize accumulations of wastes (i.e., inspect for and remove or break up accumulated solids as needed) Dry manure handling . Accumulations of animal wastes Remove spillage on a routine basis (e.g., 7- to 10- systems ❑ day inter -vat during summer; 15- to 30-day interval during winter) where manure is loaded for land application or disposal ❑Provide for adequate drainage around manure stockpiles ❑Inspect for and remove or break up accumulated wastes in filter strips around stockpiles and manure handling areas as needed For more information contact: Cooperative Extension Service, Department of Entomology, Box 7613, North Carolina State University, Raleigh, NC 27695-7613. AM IC —November 11, 1996, page 2 Swine Farm Waste Management Odor Control Checklist Source Cause BMPs to Minimize Odor Site Specific Practices Farmstead • Swine production Vegetative or wooded buffers X X Recommended best management practices Good judgment and common sense Animal body surfaces • Dirty manure -covered animals I x l Dry floors Floor surfaces • Wet manure -covered floors Manure collection pits • Urine fans • Partial microbial decomposition • Volatile gases • Dust Slotted toors Waterers located over slotted floors X Feeders at high end of solid floors X Scrape manure buildup from floors r� Underfloor ventilation for drying Frequent manure removal by flush, pit recharge, or scrape Underfloor ventilation ran mamienance X r--1 Efficient air movement Indoor surfaces • Dust FX I Washdown between groups of animals Feed additives X Feeder covers Feed delivery downspout extenders to feeder EJ covers Flush tanks • Agitation of recycled lagoon Flush tank covers liquid while tanks are filling ❑ Extend fill lines to near bottom of tanks with Ianti -siphon vents Flush alleys • Agitation during wastewater Underfloor flush with underfloor ventilation conveyance ❑ AMOC — November 11, 1996, page 1 Swine Farm Waste Management Odor Control Checklist Source Cause BMPs to Minimize Odor Site Specific Practices Pit recharge points • Agitation of recycled lagoon Extend recharge lines to near bottom of pits with liquid while pits are filling anti -siphon vents Lift stations • Agitation during sump tank Sump tank covers filling and drawdown Outside drain • Agitation during wastewater ❑ Box covers collection orjunction conveyance End of drainpipes at • Agitation during wastewater ❑ Extend discharge point of pipes underneath lagoon convevance X lagoon liouid level Lagoon surfaces • Volatile gas emissions I X I Proper lagoon liquid capacity • Biological mixing F� Correct lagoon startup procedures • Agitation X Minimum surface area -to -volume ratio X Minimum agitation when pumping ❑ Mechanical aeration Proven biological additives Irrigation sprinkler • High pressure agitation Irrigate on dry days with little or no wind nozzles • Wind drift X Minimum recommended operating pressure X Pump intake near lagoon liquid surface ElPump from second -stage lagoon Storage tank or basin • Partial microbial decomposition Bottom or midlevel loading surface ❑ • Mixing while filling ❑ Tank covers • Agitation when emptying ❑ Basin surface mats of solids ❑ Proven biological additives or oxidants AMOC — November 11, 1996, page 2 Swine Farm Waste Management Odor Control Checklist Source Cause BMPs to Minimize Odor Site Specific Practices Settling basin surface . Partial microbial decomposition Extend drainpipe outlets underneath liquid level • Mixing while filling B Remove settled solids regularly • Agitation when emptying Manure, slurry, or . Agitation when spreading ❑ Soil injection of slurry/sludges sludge spreader outlets • Volatile gas emissions ❑ Wash residual manure from spreader after use Proven biological additives or oxidants Uncovered manure, Volatile gas emissions while slurry, or sludge on drying field surfaces ❑ Soil injection of slurry/sludges ❑ Soil incorporation within 48 hours ❑ Spread in thin uniform layers for rapid drying Proven biological additives or oxidants Dead animals • Carcass decomposition F] Proper disposition of carcasses Dead animal disposal Carcass decomposition ❑ Complete covering of carcasses in burial pits pits Proper location/construction of disposal pits Incinerators • Incomplete combustion F-1 Secondary stack burners Standing water around . Improper drainage facilities • Microbial decomposition of Grade and landscape such that water drains away ❑X from facilities Manure tracked onto Poorly maintained access roads Farm access road maintenance public roads from farm l access AMOC — November 11, 1996, page 3 Additional Information: Swine Manure Management; .0200 Rule/BMP Packet Swine Production Farm Potential Odor Sources and Remedies; EBAE Fact Sheet Swine Production Facility Manure Management: Pit Recharge— Lagoon Treatment; EBAE 128-88 Swine Production Facility Manure Management: Underfloor Flush— Lagoon Treatment; EBAE 129-88 Lagoon Design and Management for Livestock Manure Treatment and Storage; EBAE 103-83 Calibration of Manure and Wastewater Application Equipment; EBAE Fact Sheet Controlling Odors from Swine Buildings; PIH-33 Environmental Assurance Program; NPPC Manual Options for Managing Odor; a report from the Swine Odor Task Force Nuisance Concerns in Animal Manure Management: Odors and Flies; PRO107, 1995 Conference Proceedings Available From: NCSU, County Extension Center NCSU— BAE NCSU—BAE NCSU— BAE NCSU— BAE NCSU— BAE NCSU— Swine Extension N.C. Pork Producers Assoc. NCSU Agricultural Communications Florida Cooperative Extension AMOC - November 11, 1996, page 4 Version —November 26, 2018 Mortality Management Methods Indicate which method(s) will be implemented. When selecting multiple methods indicate a primary versus secondary option. Methods other than those listed must be approved by the State Veterinarian. Primary Secondary Routine Mortality ® Burial three feet beneath the surface of the ground within 24 hours of knowledge of animal death. The burial must be at least 300 feet from any flowing stream or public body of water (G.S.106-403). The bottom of the burial pit should beat least one foot above the seasonal high water table. Attach burial location map and plan. Landfill at municipal solid waste facility permitted by NC DEQ under GS 15A NCAC 138 .0200. 171 ❑� Rendering at a rendering plant licensed under G.S. 106-168.7. 0 F1 Complete incineration according to 02 NCAC 52C .0102. a A composting system approved and permitted by the NC Department of Agriculture & Con- sumer Services Veterinary Division (attach copy of permit). If compost is distributed off -farm, additional requirements must be met and a permit is required from NC DEC. a In the case of dead poultry only, placing in a disposal pit of a size and design approved by the NC Department of Agriculture & Consumer Services (G.S. 106-549.70). Any method which, in the professional opinion of the State Veterinarian, would make possible the salvage of part of a dead animal's value without endangering human or animal health. (Written approval by the State Veterinarian must be attached). Mass Mortality Plan Mass mortality plans are required for farms covered by an NPDES permit. These plans are also recommended for all animal operations. This plan outlines farm -specific mortality man- agement methods to be used for mass mortality. The NCDA&CS Veterinary Division sup- ports a variety of emergency mortality disposal options; contact the Division for guidance. • A catastrophic mortality disposal plan is part of the facility's CAWMP and is activated when numbers of dead animals exceed normal mortality rates as specified by the State Veterinarian. • Burial must be done in accordance with NC General Statutes and NCDA&CS Veterinary Division regulations and guidance. • Mass burial sites are subject to additional permit conditions (refer to facility's animal waste management system permit). • In the event of imminent threat of a disease emergency, the State Veterinarian may enact / additiioonall temporary procedures or measures for disposal according to G.S. 106-399.4. uyt •�l f 2126119 Signature of Farm Owner/Manager Date 2/26/19 Signature of Technical Specialist Date 4t 1 oneybrook Dead I Stoneybroc k Dead Hole B (Max Depth iii 6'0C1 "'yLULTV��� -vy8y (l$ypP Y 1�' Steven W. Troxler North Carolina Department of Agriculture Commissioner and Consumer Services Veterinary Division May 22, 2014 Mr. Ray Cooke Swine Farm 911 Address: Murphy Brown LLC Stoneybrook Farm 785 NC 24/50 East 5707 Willard Road Warsaw, NC 28398 Willard, NC 28478 910-935-0070 - Cell Pender County State ID: 556017228 National ID: 007TMCS Dear Mr. Cooke: David T. Marshall, DVM State Veterinarian Pursuant to NCAC 52C.0102, your request to compost swine mortality on your premises at 5707 Willard Road, Willard, NC in Pender County is approved. Approval is granted under the following conditions and stipulations: 1. All North Carolina solid waste, air, water quality, and other applicable regulations must be met in siting and operation of the system 2. Only poultry or swine are to be processed in this facility; NO bovine, caprine, ovine or cervid species shall be processed 3. Mortality to be processed shall originate only from the identified premises and the finished product is used solely on agricultural operations owned, operated, or leased, by the permitee 4. The final product of the process must be stored, treated and utilized in accordance with all federal, state, and local laws, regulations, and permit requirements; the final product shall not be sold 5. Temperatures shall be within NRCS guidelines to reach a minimum of 131 degrees F within 5 days of filling the unit and remain at least at 131 degrees F for a minimum of 5 consecutive days to maintain the composting process and reduce pathogen load 6. Dead animals are not to be removed from composting until all flesh, internal organs, and other soft tissue are fully decomposed 7. The proposed facility shall have the following minimum setback requirements*: • The 100-foot buffer between all property lines and composter areas has been amended to 84 +/- feet for this composter facility due to a grandfathering exemption from NCDA&CS, Veterinary Division under the original permit issued for this composter facility in 2006 • 100-foot buffer between all wells and compost areas, except for monitoring wells • 50-foot buffer between perennial streams/rivers and compost areas • 200-foot buffer between dwellings and compost areas as long as the facility is considered a Small Type 3 facility (less than 1000 cubic yards material handled per quarter)** 1. A copy of the permit, plans, and operational reports shall be maintained on site and be available upon request by NCDA&CS, Veterinary Division personnel 1030 Mail Service Center, Raleigh, North Carolina 27699-1030 • (919) 733-7601 An Equal Opportunity Affirmative Action Employer 2. The facility and operational records shall be available for annual inspection by Veterinary Division personnel and shall be sent to the Veterinary Division upon request 3. Operational reports shall include temperature monitoring during initial facility start-up and follow- up records that contain either 10 days/month or annual laboratory results of pathogen load testing 4. An application for a permit modification shall be required for changes in facility ownership, an increase in facility capacity, or any other changes from the stipulations of this permit 5. The Veterinary Division must be immediately notified of any complicating issues involving animal disease or environmental concerns 6. The State Veterinarian reserves the right to cancel this permit if a specific concern for controlling animal disease arises, or if any of the aforementioned conditions are not met. This document shall in no circumstances be interpreted as an endorsement of any specific manufacturer or type of mortality management system by the State Veterinarian and the Office of the State Veterinarian does not approve or disapprove the technical or performance standards for specific makes or designs of equipment. *Additional requirements and regulations will apply from DENR, Division of Solid Waste Management if application for off -farm disposition of composted material is requested (see G.S. 130A-309.29 and 15A NCAC 13B, Section .1400 **If greater than 1000 cubic yards of composted material is handled in the facility per quarter, a setback from residences of 500 feet is required Sincerely, Dr. Tom Ray, DVM, MPH Director of Animal Health Programs/Livestock cc: Dr. David Marshall, State Veterinarian Dr. Sarah Mason, Director, AHP-Poultry Dr. Betty Herring, Veterinary Medical Officer Mr. Keith Warren, Advanced Composting Technologies Ms. Becky Hagan, Advanced Composting Technologies