HomeMy WebLinkAbout310756_Permit Renewal Application 2019_20190410State of North Carolina
Department of Environmental Quality
Division of Water Resources
Animal Waste Management Systems
Request for Certification of Coverage
Facility Currently covered by an Expiring Sate Non -Discharge General Permit
On September 30, 2019, the North Carolina State Non -Discharge General Permits for Animal Waste Management Systems will
expire. As required by these permits, facilities that have been issued Certificates of Coverage to operate under these State
Non -Discharge General Permits must apply for renewal at least 180 days prior to their expiration date. Therefore, all applications
must be received by the Division of Water Resources by no later than April 3, 2019.
Please do not leave any question unanswered Please verify all information and make any necessary corrections below.
Application must be signed and dated by the Permittee.
1. Farm Number: 31-0756 Certificate Of Coverage Number: AWS310756
2. Facility Name: Ricky Kornegay Farm
3. Landowner's Name (same as on the Waste Management Plan): Ricky T Kornegay
?7b Ne. 4403 itulf
4. Landowner's Mailing Address:
City: Mount Olive State: NC Zip: 28365
Telephone Number: 9,a.946€frettt Ext. E-mail:
llat-ZZ?-1034
5. Facility's Physical Address:13 &pot.ut, J g i 4.
City: lap4A4O1 i j State: /J C.- Zip: .)$365-
6. County where Facility is located: Duplin
7. Farm Manager's Name (if different from Landowner):
8. Farm Manager's telephone number (include area code):
9. Integrator's Name (if there is not an Integrator, write "None"): Prestage Farms Inc
10. Operator Name (OIC): Ricky T. Kornegay Phone No.: —149-658»634t' OIC #: 18093
1
11, Lessee's Name (if there is not a Lessee, write "None"):
12. Indicate animal operation type and number:
Current Permit: Operations Type Allowable Count
Swine - Feeder to Finish 4,410
Operation Types:
Swine Cattle Dry Poultry Other Types
Wean to Finish Dairy Calf Non Laying Chickens Horses - Horses
Wean to Feeder Dairy Heifer Laying Chickens Horses - Other
Farrow to Finish Milk Cow Pullets Sheep - Sheep
Feeder to Finish Dry Cow Turkeys Sheep - Other
Farrow to Wean Beef Stocker Calf Turkey Pullet
Farrow to Feeder Beef Feeder .
Boar/Stud Beef Broad Cow Wet Poultry
Gilts Other Non Laying Pullet
Other Layers
13. Waste Treatment and Storage Lagoons (Verify the following information is accurate and complete. Make all necessary
corrections and provide missing data.)
Structure
Name
Estimated
Date
Built
Liner Type
(Clay, Synthetic,
Unknown)
Capacity
(Cubic Feet)
Estimated
Surface Area
(Square Feet)
Design Freeboard
"Redline"
(Inches)
I
lO/7i//9ff
C(Qtf
8$4 lef
108,900.00
19.00
Mail one (1) copy of the Certified Animal Waste Management Plan (CAWMP) with this completed and signed application
as required by NC General Statutes 143-215.10C(d) to the address below.
The CAWMP must include the following components:
1. The most recent Waste Utilization Plan (WUP), signed by the owner and a certified technical specialist containing:
a. The method by which waste is applied to the disposal fields (e.g. irrigation, injection, etc.)
b. A map of every field used for land application (for example: irrigation map)
c. The soil series present on every land application field
d. The crops grown on every land application field
e. The Realistic Yield Expectation (RYE) for every crop shown in the WUP
f. The maximum PAN to be applied to every land application field
g. The waste application windows for every crop utilized in the WUP
h. The required NRCS Standard specifications
2. A site map/schematic
3. Emergency Action Plan
4. Insect Control Checklist with chosen best management practices noted
5. Odor Control Checklist with chosen best management practices noted
6. Mortality Control Checklist with selected method noted - Use the enclosed updated Mortality Control Checklist
7. Lagoon/storage pond capacity documentation (design, calculations, etc.) Please be sure the above table is accurate and
complete. Also provide any site evaluations, wetland determinations, or hazard classifications that may be applicable to
your facility.
8. Operation and Maintenance Plan
If your CAWMP includes any components not shown on this list, please include the additional components with your submittal.
(e.g. composting, digesters, waste transfers, etc.)
As a second option to mailing paper copies of the application package, you can scan and email one signed coP, of the
application and all the CAWMP items above to: 2019PermitRenewal@ncdenr.gov
I attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that,
if all required parts of this application are not completed and that if all required supporting information and attachments are not
included, this application package will be returned to me as incomplete.
Note: In accordance with -NC General Statutes 143-215.6A and • 143-215.6B; any person who knowingly makes any false statement,
representation, or certification in any application may `be —subject to'.civil penalties up -io $25,000 per violation. (18 U.S.C.
Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment of not more than 5 years, or both for
a similar offense.)
Printed Name of Signing Official (Landowner, or if multiple • Landowners all landowners should sign. If Landowner is a
corporation, signature should be by a principal executive officer of the corporation):
Name:T
Signature:
ke-t,
4)� lrh ,e5 /
Title:
Date: 3. " "
Name: Title:
Signature: Date:
Name: Title:
Signature: Date:
THE COMPLETED APPLICATION SHOULD BE SENT TO THE FOLLOWING ADDRESS:
NCDEQ-DWR •
Animal Feeding Operations Program
1636 Mail Service Center
Raleigh, North Carolina 27699-1636
Telephone number: (919) 707-9100
E-mail: 2019PermitRenewal®ncdenr.gov
FORM: RENEWAL -STATE GENERAL 02/2019
Version —November 26, 2018
Mortality Management Methods
Indicate which method(s) will be implemented.
When selecting multiple methods indicate a primary versus secondary option.
Methods other than those listed must be approved by the State Veterinarian.
Primary Secondary Routine Mortality
El El Burial three feet beneath the surface of the ground within 24 hours of knowledge of animal
death. The burial must be at least 300 feet from any flowing stream or public body of water
(G.S.106-403). The bottom of the burial pit should be at least one foot above the seasonal
high water table. Attach burial location map and plan.
CI El Landfill at municipal solid waste facility permitted by NC DEQ under GS 15A NCAC
13B .0200.
)71 El Rendering at a rendering plant licensed under G.S. 106-168.7.
Complete incineration according to 02 NCAC 52C .0102.
CI El A composting system approved and permitted by the NC Department of Agriculture & Con-
sumer Services Veterinary Division (attach copy of permit). If compost is distributed off -farm,
additional requirements must be met and a permit is required from NC DEQ.
El El In the case of dead poultry only, placing in a disposal pit of a size and design approved by the
NC Department of Agriculture & Consumer Services (G.S. 106-549.70).
a El Any method which, in the professional opiniortof the State Veterinarian, would make possible
the salvage of part of a dead animal's value without endangering human or animal health.
(Written approval by the State Veterinarian must be attached).
Mass Mortality Plan
Mass mortality plans are required for farms covered by an NPDES permit. These plans are
also recommended for all animal operations. This plan outlines farm -specific mortality man-
agement methods to be used for mass mortality. The NCDA&CS Veterinary Division sup-
ports a variety of emergency mortality disposal options; contact the Division for guidance.
• A catastrophic mortality disposal plan is part of the facility's CAWMP and is activated
when numbers of dead animals exceed normal mortality rates as specified by the State
Veterinarian.
• Burial must be:done in accordance with NC General Statutes and NCDA&CS Veterinary
Division regulations and guidance.
• Mass burial sites are subject to additional permit conditions (refer to facility's animal
waste management system permit).
• In the event of imminent threat of a disease emergency, the State Veterinarian may enact
additional temporary procedures or measures for disposal according to G.S. 106-399.4.
Signature of Farm anager
Signature o ethnical Specialist Date
Date
3 - — �q
Nutrient Management Plan For Animal Waste Utilization
06-09-2016
This plan has been prepared for:
Ricky Kornegay Farm 31-756
Ricky Kornegay
756 NC 403 W
Mount Olive, NC 28365
919-658-6341
This plan has been developed by:
Ronnie G. Kennedy Jr.
Agriment Services, Inc.
PO Box 1096
Beulaville, NC 28518
252-56
veloper Signature
Type of Plan: Nitrogen Only with Manure Only
Owner/Manager/Producer Agreement
I (we) understand and agree to the specifications and the operation and maintenance
procedures established in this nutrient management plan which includes an animal
waste utilization plan for the farm named above. I have read and understand the
Required Specifications concerning animal waste management that are included with
this plan.
Signature
47-)
63/ /
Date
Signature (manager or producer) Date
This plan meets the minimum standards and specifications of the U.S. Department of
Agriculture - Natural Resources Conservation Service or the standard of practices
adopted by the Soil and Water Conservation Commission.
Plan Approved By:
C/0‘
Lchnical Specialist Signature Date
567313 Database Version 4.1 Date Printed: 06-09-2016 Cover Page 1
Nutrients applied in accordance with this plan will be supplied from the
following source(s):
Commercial Fertilizer is not included in this plan.
S7
Swine Feeder -Finish Lagoon Liquid waste generated 4,088,070 gals/year by a 4,410
animal Swine Finishing Lagoon Liquid operation. This production facility has waste
storage capacities of approximately 180 days.
Estimated Pounds of Plant Available Nitrogen Generated per Year
Broadcast
7369
Incorporated
8843
Injected
8843
Irrigated
7369
Max. Avail.
PAN (lbs) *
Actual PAN
Applied (lbs)
PAN Surplus/
Deficit (lbs)
Actual Volume
Applied (Gallons)
Volume Surplus/
Deficit (Gallons)
Year 1
7,369
13710
-6,341
7,606,134
-3,518,064
Year 2
7,369
15179
-7,810
8,421,077
-4,333,007
Note: In source ID, S means standard source, U means user defined source.
* Max. Available PAN is calculated on the basis of the actual application method(s) identified in the plan for this source.
567313 Database Version 4.1 Date Printed: 06-09-2016 Source Page 1 of 1
Narrative
6/9/2016
THIS PLAN IS TO ADD CENTER PIVOT TO TRACT 1320 F2. THIS FIELD IS OWNED BY
GROWER.
10/3/2002
REVISED ADDENDUM TO WASTE UTILIZATION PLAN:
FACILITY NUMBER 31-756
FARM NAME: RICKY KORNEGAY FARM
OWNER NAME: RICKY KORNEGAY
DESIGN CAPACITY: 4410 FEEDER TO FINISH
THIS PLAN IS A REVISION OF THE 9/3/97 PLAN COMPLETED BY BILLY HOUSTON OF
DUPLIN SWCD. THIS PLAN DEPICTS THE WETTABLE ACRES ON THE FARM AND
DISPLAYS THE SAME IN THE CALCULATION TABLES. (SEE WETTABLE ACRE
DETERMINATION)
MR. KORNEGAY HAS WRITTEN PERMISSION TO UTILIZE FOR WASTE APPLICATION
TRACT 1320 FI & F2 IF EVER NEEDED. THESE FIELDS ARE DEDICATED TO CROPLAND
AND WITH THE ASSIGNMENT OF APPLCATION WINDOWS AND CROPS BY A TECHNICAL
SPECIALIST MAY BE INCORPORATED IN THE PLAN. THERE IS ALSO ADDITIONAL
ACREAGE THAT MAY BE UTILIZED BY HONEYWAGON IF NEEDED. CURRENTLY, MR.
KORNEGAY DOES NOT NEED THESE ACRES TO FULFILL THE REQUIREMENTS OF HIS
WUP.
NO WASTE SHOULD BE APPLIED TO A CROP THAT DOES NOT HAVE A REALISTIC YIELD
FOR THE USAGE OF IRRIGATED SWINE WASTE, EXCEPT FOR PREPLANT. ALL FIELDS
MUST MEET MONITORING AND REPORTING REQUIREMENTS WHEN USED. MR.
KORNEGAY PLANS TO APPLY SWINE WASTE IN ACCORDANCE WITH HIS SPECIFIC WASTE
ANALYSIS NOT TO EXCEED THE HYDRAULIC LOADING OF THE SOILS.
567313 Database Version 4.1 Date Printed: 06-09-2016 Narrative Page 1 of 1
The table shown below provides a summary of the crops or rotations included in this plan for each field. Realistic
Yield estimates are also provided for each crop in the plan. In addition, the Leaching Index for each field is shown,
where available.
Planned Crops Summary
Tract
Field
Total
Acres
Useable
Acres
Leaching
Index (LI)
Soil Series
Crop Sequence
RYE
1320
F2
59.70
18.55
N/A
Goldsboro
Corn, Grain
130 bu.
Wheat, Grain
65 bu.
Soybeans, Manured, Double Crop
38 bu.
1321
F1
60.10
51.40
N/A
Goldsboro
Corn, Grain
130 bu.
Wheat, Grain
65 bu.
Soybeans, Manured, Double Crop
38 bu.
PLAN TOTALS:
119.80 69.95
LI
Potential Leaching
Technical Guidance
2
Low potential to contribute to soluble
nutrient leaching below the root zone.
None
>= 2 &
Moderate potential to contribute to
Nutrient Management (590) should be planned.
<= 10
soluble nutrient leaching below the root
zone.
High potential to contribute to soluble
Nutrient Management (590) should be planned. Other conservation practices that improve
nutrient leaching below the root zone.
the soils available water holding capacity and improve nutrient use efficiency should be
> 10
considered. Examples are Cover Crops (340) to scavenge nutrients, Sod -Based Rotations
(328), Long -Term No -Till (778), and edge -of -field practices such as Filter Strips (393) and
Riparian Forest Buffers (391).
567313 Database Version 4.1
NOTE: Symbol * means user entered data.
Date Printed 6/9/2016
PCS Page 1 of 1
The Waste Utilization table shown below summarizes the waste utilization plan for this operation. This plan provides an estimate of the number of acres of
cropland needed to use the nutrients being produced. The plan requires consideration of the realistic yields of the crops to be grown, their nutrient requirements,
and proper timing of applications to maximize nutrient uptake.
This table provides an estimate of the amount of nitrogen required by the crop being grown and an estimate of the nitrogen amount being supplied by manure or
other by-products, commercial fertilizer and residual from previous crops. An estimate of the quantity of solid and liquid waste that will be applied on each field in
order to supply the indicated quantity of nitrogen from each source is also included. A balance of the total manure produced and the total manure applied is
included in the table to ensure that the plan adequately provides for the utilization of the manure generated by the operation.
Tract
Field
Source
ID
Soil Series
Total
Acres
Use.
Acres
Crop
RYE
Applic.
Period
Nitrogen
PA
Nutrient
Regd
(lbs/A)
Comm.
Fen.
Nutrient
Applied
(lbs/A)
Res.
(lbslA)
Applic.
Method
Manure
PA
Nutrient
Applied
(lbs/A)
Liquid
ManureA
pplied
(acre)
Solid
Manure
Applied
(acre)
Liquid
Manure
Applied
(Field)
Solid
Manure
Applied
(Field)
N
N
N
N
1000
gal/A
Tons
1000 gals
tons
1320
F2
S7
Goldsboro
59.70
18.55
Com, Grain
130 bu.
2/15-6/30
148
0
20
lrrig.
128
71.01
0.00
1,317.27
0.00
1320
F2
S7
Goldsboro
59.70
18.55
Wheat, Grain
65 bu.
9/1-4/30
136
0
0
Irrig.
68
37.73
0.00
699.80
0.00
1321
F1
S7
Goldsboro
60.10
51.40
Com, Grain
130 bu.
2/15-6/30
148
0
20
Irrig.
128
71.01
0.00
3,650.00
0.00
1321
Fl
S7
Goldsboro
60.10
51.40
Wheat, Grain
65 bu.
9/1-4/30
136
0
0
Irrig.
68
37.73
0.00
1,939.06
0.00
Total Applied, 1000 gallons
7,606.13
Total Produced, 1000 gallons
4,088.07
Balance, 1000 gallons
-3,518.06
Total Applied, tons
0.00
Total Produced, tons
0.00
Balance, tons
0.00
Notes: 1. In the tract column, --- symbol means leased, otherwise, owned.
2. Symbol * means user entered data.
56731
Database Version 4.1
Date Printed: 6/9/2016
WUT Page 1,2
♦♦ QJLA.
Tract
V LLLLI.fatnVLL
Field
a
Source
ID
uvf•.
Soil Series
Total
Acres
Use.
Acres
—
Crop
--- —
RYE
Applic.
Period
Nitragen
PA
Nutrient
Req'd
(lbs/A)
Comm
Fen.
Nutrient
Applied
(lbs/A)
Res.
(Ibs/A)
Applic.
Method
Manure
PA
Nutrient
Applied
(Ibs/A)
Liquid
ManureA
pphed
(acre)
Solid
Manure
Applied
(acre)
Liquid
Manure
Applied
(Field)
Solid
Manure
Applied
(Field)
N
I
N
N
N
1000
gal/A
Tons
1000 gals
tons
1320
F2
S7
Goldsboro
59.70
18.55
Wheat, Grain
65 bu.
9/1-4/30
136
0
0
Irrig.
68
37.73
0.00
699.80
0.00
1320
F2
S7
Goldsboro
59.70
18.55
Soybeans, Manured, Double Crop
38 bu.
4/1-9/15
149
0
0
Irrig.
149
82.66
0.00
1,533.38
0.00
1321
FI
S7
Goldsboro
60.10
51.40
Wheat, Grain
65 bu.
9/1-4/30
136
0
0
Irrig.
68
37.73
0.00
1,939.06
0.00
1321
FI
S7
Goldsboro
60.10
51.40
Soybeans, Manured, Double Crop
38 bu.
4/1-9/15
149
0
0
Irrig.
149
82.66
0.00
4,248.83
0.00
Total Applied, 1000 gallons
8,421.08
Total Produced, 1000 gallons
4,088.07
Balance, 1000 gallons
-4,333.01
Total Applied, tons
0.00
Total Produced, tons
0.00
Balance, tons
0.00
Notes: 1. In the tract column, — symbol means leased, otherwise, owned.
2. Symbol * means user entered data.
56731
Database Version 4.1 Date Printed: 6/9/2016
WUT Page 2 2
The Irrigation Application Factors for each field in this plan are shown in the following table. Infiltration rate varies
with soils. If applying waste nutrients through an irrigation system, you must apply at a rate that will not result in
runoff. This table provides the maximum application rate per hour that may be applied to each field selected to
receive wastewater. It also lists the maximum application amount that each field may receive in any one application
event.
Irrigation Application Factors
Tract
Field
Soil Series
Application Rate
(inches/hour)
Application Amount
(inches)
1320
F2
Goldsboro
0.50
1.0
1321
F 1
Goldsboro
0.50
1.0
567313 Database Version 4.1 Date Printed 6/9/2016
NOTE: Symbol * means user entered data.
IAF Page 1 of 1
The following Lagoon Sludge Nitrogen Utilization table provides an estimate of the number of acres needed for
sludge utilization for the indicated accumulation period. These estimates are based on average nitrogen
concentrations for each source, the number of animals in the facility and the plant available nitrogen application
rates shown in the second column.
Lagoon sludge contains nutrients and organic matter remaining after treatment and application of the effluent. At
clean out, this material must be utilized for crop production and applied at agronomic rates. In most cases, the
priority nutrient is nitrogen but other nutrients including phosphorous, copper and zinc can also be limiting. Since
nutrient levels are generally very high, application of sludge must be carefully applied.
Sites must first be evaluated for their suitability for sludge application. Ideally, effluent spray fields should not be
used for sludge application. If this is not possible, care should be taken not to load effluent application fields with
high amounts of copper and zinc so that additional effluent cannot be applied. On sites vulnerable to surface water
moving to streams and lakes, phosphorous is a concern. Soils containing very high phosphorous levels may also
be a concern.
n Table
.r,.�.,.,__ ----a-
Crop
- --- -c Maximum
PA-N Rate
lb/ac
Maximum Sludge
Application Rate
1000 gal/ac
Minimum Acres
5 Years Accumulation
Minimum Acres
10 Years Accumulation
Minimum Acres
15 Years Accumulation
Swine Feeder -Finish Lagoon Sludge - Standard
Corn 120 bu
150
14.69
49.54
99.08
148.62
Hay 6 ton R.Y.E.
300
29.38
24.77
49.54
74.31
Soybean 40 bu
160
15.67
46.44
92.88
139.33
567313 Database Version 4.1 Date Printed: 06-09-2016 Sludge Page 1 of 1
The Available Waste Storage Capacity table provides an estimate of the number of days of storage
capacity available at the end of each month of the plan. Available storage capacity is calculated as the
design storage capacity in days minus the number of days of net storage volume accumulated. The start
date is a value entered by the user and is defined as the date prior to applying nutrients to the first crop in
the plan at which storage volume in the lagoon or holding pond is equal to zero.
Available storage capacity should be greater than or equal to zero and less than or equal to the design
storage capacity of the facility. If the available storage capacity is greater than the design storage
capacity, this indicates that the plan calls for the application of nutrients that have not yet accumulated.
If available storage capacity is negative, the estimated volume of accumulated waste exceeds the design
storage volume of the structure. Either of these situations indicates that the planned application interval
in the waste utilization plan is inconsistent with the structure's temporary storage capacity.
i"Avaiiatn
Source Name
Taal.✓ 471ViGL v t..c4tluvit.r
Swine Feeder -Finish Lagoon Liquid
Design Storage Capacity (Days)
Start Date
09/01
180
Plan
Year
Month
Available Storage Capacity (Days) *
1
1
28
1
2
89
1
3
147
1
4
180
1
5
180
1
6
180
1
7
149
1
8
118
1
9
135
1
10
175
1
11
180
1
12
180
2
1
180
2
2
180
2
3
180
2
4
180
2
5
180
2
6
180
2
7
180
2
8
180
2
9
180
2
10
149
2
11
119
2
12
88
* Available Storage Capacity is calculated as of the end of each month.
567313 Database Version 4.1 Date Printed: 06-09-2016 Capacity Page 1 of 1
Required Specifications For Animal Waste Management
1. Animal waste shall not reach surface waters of the state by runoff, drift,
manmade conveyances, direct application, or direct discharge during
operation or land application. Any discharge of waste that reaches surface
water is prohibited.
2. There must be documentation in the design folder that the producer
either owns or has an agreement for use of adequate land on which to
properly apply the waste. If the producer does not own adequate land to
properly dispose of the waste, he/she shall provide evidence of an
agreement with a landowner, who is within a reasonable proximity,
allowing him/her the use of the land for waste application. It is the
responsibility of the owner of the waste production facility to secure an
update of the Nutrient Management Plan when there is a change in the
operation, increase in the number of animals, method of application,
receiving crop type, or available land.
3. Animal waste shall be applied to meet, but not exceed, the nitrogen needs
for realistic crop yields based upon soil type, available moisture, historical
data, climatic conditions, and level of management, unless there are
regulations that restrict the rate of applications for other nutrients.
4. Animal waste shall be applied to land eroding less than 5 tons per acre
per year. Waste may be applied to land eroding at more than 5 tons per
acre per year but less than 10 tons per acre per year provided grass filter
strips are installed where runoff leaves the field (see USDA, NRCS Field
Office Technical Guide Standard 393 - Filter Strips).
5. Odors can be reduced by injecting the waste or by disking after waste
application. Waste should not be applied when there is danger of drift
from the land application field.
6. When animal waste is to be applied on acres subject to flooding, waste
will be soil incorporated on conventionally tilled cropland. When waste is
applied to conservation tilled crops or grassland, the waste may be
broadcast provided the application does not occur during a season prone
to flooding (see "Weather and Climate in North Carolina" for guidance).
567313 Database Version 4.1 Date Printed: 6/9/2016 Specification Page 1
rN
7. Liquid waste shall be applied at rates not to exceed the soil infiltration
rate such that runoff does not occur offsite or to surface waters and in a
method which does not cause drift from the site during application. No
ponding should occur in order to control odor and flies.
8. Animal waste shall not be applied to saturated soils, during rainfall
events, or when the soil surface is frozen.
9. Animal waste shall be applied on actively growing crops in such a manner
that the crop is not covered with waste to a depth that would inhibit
growth. The potential for salt damage from animal waste should also be
considered.
10. Nutrients from waste shall not be applied in fall or winter for spring
planted crops on soils with a high potential for leaching. Waste/nutrient
loading rates on these soils should be held to a minimum and a suitable
winter cover crop planted to take up released nutrients. Waste shall not
be applied more than 30 days prior to planting of the crop or forages
breaking dormancy.
11. Any new swine facility sited on or after October 1,1995 shall comply with
the following: The outer perimeter of the land area onto which waste is
applied from a lagoon that is a component of a swine farm shall be at least
50 feet from any residential property boundary and canal. Animal waste,
other than swine waste from facilities sited on or after October 1,1995,
shall not be applied closer that 25 feet to perennial waters.
12. Animal waste shall not be applied closer than 100 feet to wells.
13. Animal waste shall not be applied closer than 200 feet of dwellings other
than those owned by the landowner.
14. Waste shall be applied in a manner not to reach other property and
public right-of-ways.
567313 Database Version 4.1 Date Printed: 6/9/2016 Specification Page 2
reN
15. Animal waste shall not be discharged into surface waters, drainageways,
or wetlands by a discharge or by over -spraying. Animal waste may be
applied to prior converted cropland provided the fields have been
approved as a land application site by a "technical specialist". Animal
waste shall not be applied on grassed waterways that discharge directly
into water courses, and on other grassed waterways, waste shall be
applied at agronomic rates in a manner that causes no runoff or drift
from the site.
16. Domestic and industrial waste from washdown facilities, showers, toilets,
sinks, etc., shall not be discharged into the animal waste management
system.
17. A protective cover of appropriate vegetation will be established on all
disturbed areas (lagoon embankments, berms, pipe runs, etc.). Areas
shall be fenced, as necessary, to protect the vegetation. Vegetation such as
trees, shrubs, and other woody species, etc., are limited to areas where
considered appropriate. Lagoon areas should be kept mowed and
accessible. Berms and structures should be inspected regularly for
evidence of erosion, leakage, or discharge.
18. If animal production at the facility is to be suspended or terminated, the
owner is responsible for obtaining and implementing a "closure plan"
which will eliminate the possibility of an illegal discharge, pollution, and
erosion.
19. Waste handling structures, piping, pumps, reels, etc., should be inspected
on a regular basis to prevent breakdowns, leaks, and spills. A regular
maintenance checklist should be kept on site.
20. Animal waste can be used in a rotation that includes vegetables and other
crops for direct human consumption. However, if animal waste is used on
crops for direct human consumption, it should only be applied pre -plant
with no further applications of animal waste during the crop season.
21. Highly visible markers shall be installed to mark the top and bottom
elevations of the temporary storage (pumping volume) of all waste
treatment lagoons. Pumping shall be managed to maintain the liquid level
between the markers. A marker will be required to mark the maximum
storage volume for waste storage ponds.
567313 Database Version 4.1 Date Printed: 6/9/2016 Specification Page 3
roN
22. Waste shall be tested within 60 days of utilization and soil shall be tested
at least annually at crop sites where waste products are applied. Nitrogen
shall be the rate -determining nutrient, unless other restrictions require
waste to be applied based on other nutrients, resulting in a lower
application rate than a nitrogen based rate. Zinc and copper levels in the
soils shall be monitored and alternative crop sites shall be used when
these metals approach excessive levels. pH shall be adjusted and
maintained for optimum crop production. Soil and waste analysis
records shall be kept for a minimum of five years. Poultry dry waste
application records shall be maintained for a minimum of three years.
Waste application records for all other waste shall be maintained for five
(5) years.
23. Dead animals will be disposed of in a manner that meets North Carolina
regulations.
567313 Database Version 4.1 Date Printed: 6/9/2016 Specification Page 4
Crop Notes
The following crop note applies to field(s): F 1, F2
Corn 1: CP, Mineral Soil, low -leachable
In the Coastal Plain, corn is normally planted when soil temperatures reach 52 to 55 degrees fahrenheit.
Review the Official Variety "green book" and information from private companies to select a high
yielding variety with the characteristics needed for your area and conditions. Plant 1-2" deep. Plant
populations should be determined by the hybrid being planted. Increase the seeding rate by 10% when
planting no -till. Phosphorus and potassium recommended by a soil test can be broadcast or banded at
planting. When planting early in cool, wet soil, banded phosphorus will be more available to the young
plants. An accepted practice is to apply 20-30 lbs/acre N and 20-30 lbs/acre phosphorus banded as a
starter and one-half the remaining N behind the planter. The rest of the N should be applied about 30-40
days after emergence. The total amount of N is dependent on soil type. When including a starter in the
fertilizer program, the recommended potassium and any additional phosphorus is normally broadcast at
planting. Plant samples can be analyzed during the growing season to monitor the overall nutrient status
of the corn. Timely management of weeds and insects are essential for corn production.
The following crop note applies to field(s): F1, F2
Wheat: Coastal Plain, Mineral Soil, low -leachable
In the Coastal Plain, wheat should be planted from October 20-November 25. Plant 22 seed/drill row foot
at 1-1 1/2" deep and increase the seeding rate by 5% for each week seeding is delayed beyond the
optimum time. See the seeding rates table for applicable seeding rate modifications in the current NCSU
"Small Grain Production Guide". Also, increase the initial seeding rate by at least 10% when planting
no -till. Adequate depth control when planting the wheat is essential. Review the NCSU Official Variety
"green book" and information from private companies to select a high yielding variety with the
characteristics needed for your area and conditions. Apply no more than 30 lbs/acre N at planting.
Phosphorus and potash recommended by a soil test can also be applied at this time. The remaining N
should be applied during the months of February -March. The total N is dependent on the soil type. Plant
samples can be analyzed during the growing season to monitor the nutrient status of the wheat. Timely
management of diseases, insects and weeds are essential for profitable wheat production.
567313 Database Version 4.1 Date Printed: 06-09-2016 Crop Note Page 1 of 2
The following crop note applies to field(s): F 1, F2
Double -Crop Soybeans, Coastal Plain: Mineral Soil, low -leachable
Double -crop soybeans should be planted as early in June as possible with planting completed by July 4th.
When no -tilling soybeans in small grain straw, it is essential to manage the straw to achieve adequate
plant populations. Review the NCSU Official Variety "green book" and information from private
companies to select a high yielding variety with the characteristics needed for your area and conditions.
Plant 2-4 seed/row foot for 7-8" drills; 4-6 seed/row foot for 15" rows; 6-8 seed/row foot for 30" rows
and 8-10 seed/row foot for 36" rows. Increase the seeding rate by at least 10% for no -till planting.
Seeding depth should be 1-1 1/2" and adequate depth control is essential. Phosphorus and potash
recommended for the soybeans can be applied to the wheat in the Fall. Soybeans produce their own
nitrogen and are normally grown without additions of nitrogen. However, applications of 20-30 lbs/acre
N are sometimes made at planting to promote early growth and vigor. Tissue samples can be analyzed
during the growing season to monitor the overall nutrient status of the soybeans. Timely management of
weeds and insects is essential for profitable double crop soybean production.
567313 Database Version 4.1 Date Printed: 06-09-2016 Crop Note Page 2 of 2
6/9/2016 1:C1 PM, 1:600
ZIMMATIC
SY LiNDS.4Y
Design Detail
Quality Equipment, LLC
504 Faison Highway
Clinton , NC 28328
Office: 910-923-9954; (2): 910-237-2350
rnjacksonequalityequip-com
ZIMMATIC
Design Detail
BY LINDSAY
Pivot Wetted Area:
Corner Wetted Area:
Endgun Wetted Area:
3 span
Quality Equipment, LLC
504 Faison Highway
Clinton , NC 28328
Office: 910-923-9954; (2): 910-237-2350
mjackson@qualityequip.com
Pivot Point: 35.158889° -78.060782°
15.54 acres
NA
3.01 acres
Total Wetted Area:
18.55 acres
Spans
1
2
3
Overhang:
158.08 ft
315.17 ft
450.17 ft
464.17 ft
157'
157'
135'
11ft
6 - 5/8"
6 - 5/8"
6-5/8"
5 - 9/16"
System Length:
Number of Spans:
Degree of Sweep
Endgun Throw:
Primary Endgun
Start and Stop Angle Start and Stop Angle Deg Start Position
Deg From North From Start Lat / Long
464.17 ft
3
360 Degrees
100.00 ft
Stop Position Lat /
Long
Area
30.50 / 90.20
157.60 / 181.90
193.60/ 234.50
301.30 / 322.80
30.50 / 90.20
157.60 / 181.90
193.60 / 234.50
301.30 / 322.80
35.1599 /
-78.0599
35.1577 /
-78.0601
35.1576 /
-78.0611
35.1595 /
-78.0621
35.1588 /-78.0592
35.1576 /-78.0608
35.1581 /-78.0620
35.1599 /-78.0617
1.23
0.50
0.84
0.44
ZIMM1TIc
BY LINDSAY
Sales Order Detail
Quality Equipment, LLC
504 Faison Highway
Clinton , NC 28328
Office: 910-923-9954; (2): 910-237-2350
mjackson@qualityequip.com
3 span
Sold To:
Order No.
3 span
Ricky Kornegay
Date:
2/15/2016
Ship To:
Sales Rep:
Matthew Jackson
System
System Type
System Length
Outlet Count
8500P w/ 8500 Series Spans
464.17
System Information
1 0155970 6-5/8" Compact, Standard, Non -Tow, 8500P
1 0155980 Compact, Non -Tow, 84.5" x 84.5", 17.5" Anchor Bolts Included
1 0159080 VISION, 480V, 11 wire CR, Encoder, for 8500P
3 1155662 Fuse, 15 Amp, 600 Volt, Class CC
1 1603691 FieIdNET, CDMA Cellular, Verizon
2 0156030 6-5/8", 157' (47.87m) Solid, 90" spacing, 8500P
1 0156020 6-5/8", 135' (41.16m) Solid, 90" spacing, 8500P
1 0165760 5.9/16" x 11' (3.35m) Overhang, 90" Spacing, 8500P
1 0181200 5R100, Nozzle Valve 130 GPM BP, 11'-22' (3.35m-6.71m) Overhang, Tower Mount
2 0165570 6-5/8" Joint, 8500P
1 0137745 6-5/8" last Tower Joint
3 0165560 Non -Tow Tower Structure, 8500P
3 0137026 Plug, Quick Drain, 20-75 PSI, Multi Pressure (Red)
1 0121673 Tower Control, Standard, 8 5/8", 8", 6-5/8" & 5-9/16"
1 0121681 Tower Control, Next -To -Last, 8-5/8", 8", 6-5/8" & 5-9/16"
1 0121699 Tower Control, Last
3 0162450 Non -Tow, AT Gearbox
3 0113498 Lindsay 43 RPM
3 0116913 14.9 x 24, New, w/o Tube, 8" Rim
2 0147940 12 AWG, 157' (47.87m), 11 wire, Span Cable
1 0147930 12 AWG, 135' (41.16m), 11 wire, Span Cable
50 0169570 All Poly Red Memory Drops FxM @ Truss Length 96"
50 0157710 Gooseneck, Senninger, 180 Deg, F x M w/ Poly Nipple Inserted, M x M
50 0185910 Nelson R3030. Rotator
Misc Items
1
1
1
Dealer Parts
1
QEI-CPP-002
pipe install with pipe 1100'
build electrical service with meter box, panel, and labor
15 hp. electric pump
Compact pivot pad
Ricky Kornegay
7/10/02
Hard Hose Traveling Gun System
Wettable Acre Computations
Performance Guide & Specifications
Model
Flow Rate
(GPM)
Inlet
Pressure
(PSI)
Hose
Length
(Ft)(Ft.)
Hose I.D.
(In.)
Lane
Spacing
Acres Per
Pull
Time To Apply
1 Inch Acre
(Min.)
Time Per Pull
(Hrs.)
Cadman 2625
177
130
900
2.625
257
5.9
154.8
15.2
100 RING NOZZLE 100R
100R = Body + Cap + Set of 7 Rings
Specify size when ordering
Complete set of 7 rings only = #6847
0.71"
6738-071
0.77"
6738-077
L (
0.81 "
6738-081
COMPONENTS:
Body Ring
#9956-001 #6738-??? #7872
(711t#
_86" 0.89"
6738-086 6738-089
Cap
0.93"
673E-093
Flow Path
0.96"
6738-096
PSI
GPM
DU 9
GPM
CIA 9
GPM
DIA 9
GPM
DIA Fr
GPM
DIA Fl
GPM
DIA Fl
GPM
DIA Fr
40
66
208
78
212
91
215
103
224
118
235
134
23B
152
242
50
74
220
88
225
100
230
115
240
129
250
150
255
167
260
60
81
235
96
240
110
245
125
260
141
270
(j64
27
183
280
70
)
88
245
104
250
118
260
2
152
290
177
295
198
300
80
94
255
111
265
127
275
145
285
163
300
189
305
211
315
90
99
265
117
275
134
285
154
295
173
310
201
315
224
325
100
105
270
124
280
142
295
162
305
182
320
212
325
236
335
110
110
275
130
290
149
305
170
315
191
325
222
335
248
345
faan'eten eta bated on 24' trojahay Bie Gun' porfomnnce dulu ha beau abkine l under ideal txt milion and may be adversely oBect.d by wind. poor hydofic enhmt& cordikrt or oil+w;won Nelun I,,4 akr
Carpav40n from no raaraortbnon rogardr g droplet arrhion, urifomity, or oprl cdim rotes
Existing Hard Hose Traveler Gun Irrigation System
• # of Exterior Lanes 6
• # of Interior Lanes 7
• # of Total Lanes 13
• Lane Spacing 157'
• Wetted o [Field Verified] 275'
• Lane Spacing as a % 57%
1
Ricky Kornegay
7/1 0/02
T-1321 F 160.1 ac. +i_ Spray Field
Lane 1
➢ Start End .Area [Table EE60 - B] 0.56 ac.
➢ Middle Area [802'(275'/2 + 157'/2)/43,560] 3.98 ac.
➢ Stop End Area [Table EE60 - G] 0.45 ac.
➢ Total Area [(0.56 ac. + 3.98 ac. + 0.45 ac.)] 4.99 ac.
Lane 2
D. Start End Area [Table EI60 - B] 0.47 ac.
➢ Middle Area [817'(157')/43,560] 2.94 ac.
D. Stop End Area [Table EI60 - G] 0.36 ac.
Total Area [(0.47 ac. + 2.94 ac. + 0.36 ac.)] 3.77 ac.
Lane 3
➢ Start End Area [Table EI60 - B] 0.47 ac.
➢ Middle Area [833'(157')/43,560] 3.00 ac.
➢ Stop End Area [Table EI60 - G] 0.36 ac.
D. Total Area [(0.47 ac. + 3.00 ac. + 0.36 ac.)] 3.83 ac.
Lane 4
➢ Start End Area [Table EI60 - B] 0.47 ac.
Middle Area [848'(157)/43,560] 3.06 ac.
• Stop End Area [Table EI60 - G] 0.36 ac.
➢ Total Area [(0.47 ac. + 3.06 ac. + 0.36 ac.)] 3.89 ac.
Lanes
D. Start End Area [Table EI60 - B] 0.47 ac.
D. Middle Area [864'(157)/43,560] 3.11 ac.
D. Stop End Area [Table EI60 - G] 0.36 ac.
➢ Total Area [(0.47 ac. + 3.11 ac. + 0.36 ac.)] 3.94 ac.
Lane 6
Start End Area [Table EE60 - B] 0.56 ac.
• Middle Area [878'(275'/2 + 157'/2)/43,560] 4.35 ac.
➢ Stop End Area [Table EE60 - G] 0.45 ac.
➢ Total Area [(0.56 ac. + 4.35 ac. + 0.45 ac.)] 5.36 ac.
Lane 7
➢ Start End Area [Table EE60 - B] 0.56 ac.
➢ Middle Area [900'(275'/2 + 157'/2)/43,560] 4.46 ac.
Stop End Area [Table EE60 - G] 0.45 ac.
Total Area [(0.56 ac. + 4.35 ac. + 0.45 ac.)] 5.47 ac.
2
Ricky Kornegay
Lane 8
7/10/02
➢ Start End Area [Table EI60 - B] 0.47 ac.
➢ Middle Area [900'(157)/43,560] 3.24 ac.
• Stop End Area [Table EI60 - G] 0.36 ac.
➢ Total Area [(0.47 ac. + 3.24 ac. + 0.36 ac.)] 4.07 ac.
Lane 9
➢ Start End Area [Table EI60 - B] 0.47 ac.
➢ Middle Area [900'(157)/43,560] 3.24 ac.
Stop End Area [Table EI60 - G] 0.36 ac.
> Total Area [(0.47 ac. + 3.24 ac. + 0.36 ac.)] 4.07 ac.
Lane 10
D. Start End Area [Table EI60 - B] 0.47 ac.
➢ Middle Area [900'(157)/43,560] 3.24 ac.
➢ Stop End Area [Table EI60 - G] 0.36 ac.
> Total Area [(0.47 ac. + 3.24 ac. + 0.36 ac.)] 4.07 ac.
Lane 11
➢ Start End Area [Table EE60 - B] 0.56 ac.
Middle Area [143'(275'/2 + 157'/2)/43,560] 0.71 ac.
> Stop End Area [Table EE60 - G] 0.45 ac.
➢ Total Area [(0.56 ac. + 0.71 ac. + 0.45 ac.)] 1.72 ac.
Lane 12
➢ Start End Area [Table EE60 - B] 0.56 ac.
➢ Middle Area [321'(275'/2 + 157'/2)/43,560] 1.59 ac.
➢ Stop End Area [Table EE60 - G] 0.45 ac.
➢ Total Area [(0.56 ac. + 1.59 ac. + 0.45 ac.)] 2.60 ac.
Lane 13
➢ Start End Area [Table EE60 - B] 0.56 ac.
➢ Middle Area [526'(275'/2 + 157'/2)/43,560] 2.61 ac.
Stop End Area [Table EE60 - G] 0.45 ac.
➢ Total Area [(0.56 ac. + 2.61 ac. + 0.45 ac.)] 3.62 ac.
T-1321 F1 Total Wettable Acres 51.40 arc.
T 1321 F i Honey Wagon Acres 1.75 ac.
3
Ricky Kornegay 7/10/02
Available Honey Wagon, 'i.Qs],d Needed
'r 1330 Fl 111.10 ac.
T 1320 F2 59.70 a.c.
Prepared by Agriment Services Inc.
P.O. Box 1096 - Beulaville , NC - 28518
Phone (252) 568-2648 - Fax (252) 568-2750
Signature of owner or facility representative Signure of technical specialist
Poe J `yj
Printed name of the same above
Date
(3/3/° 61-
/ (' .fs G /�-'e'A ,4eo(f A
Printed name of the same above
Date
4
4. TOTAL DESIGNED VOLUME
Inside top length (feet)
Inside top width (feet)
Top of dike elevation (feet)
Bottom of lagoon elevation (feet)
Freeboard (feet)
Side slopes (inside lagoon)
:rator:Ricky Kornegay County: Duplin Date: 10/24/94
Distance to nearest residence (other than owner): 1700.0 feet
1. AVERAGE LIVE WEIGHT (ALW)
0 sows (farrow to finish) x 1417 lbs. = 0 lbs
0 sows (farrow to feeder) x 522 lbs. = 0 lbs
4410 head (finishing only) x 135 lbs. = 595350 lbs
0 sows (farrow to wean) x 433 lbs. = 0 lbs
0 head (wean to feeder) x 30 lbs. = 0 lbs
Describe other : 0
Total Average Live Weight = 595350 lbs
2. MINIMUM REQUIRED TREATMENT VOLUME OF LAGOON
Volume = 595350 lbs. ALW x Treatment Volume(CF)/lb. ALW
Treatment Volume(CF)/lb. ALW = 1 CF/lb. ALW
Volume = 595350 cubic feet
3. STORAGE VOLUME FOR SLUDGE ACCUMULATION SLUDGE ,qCGVm vI..igl joN 1o7 CO/6 p/np
Volume = 0.0 cubic feet 64T OWNERS RE QUEST, REMovE .SLUOG&
ASS NEEDED .
Total design volume using prismoidal formula
380.0
-258.7
49.8
36.8
1.0
3.0 : 1
SS/END1 SS/END2 SS/SIDE1 SS/SIDE2 LENGTH WIDTH DEPTH
3.0 3.0 3.0 3.0 374.0 252.7 12.0
AREA OF TOP
LENGTH * WIDTH =
374.0 252.7
AREA OF BOTTOM
LENGTH * WIDTH =
302.0 180.7
94509 (AREA OF TOP)
54571 (AREA OF BOTTOM)
AREA OF MIDSECTION
LENGTH * WIDTH * 4
338.0 216.7 292975 (AREA OF MIDSECTION * 4)
CU. FT. = [AREA TOP + (4*AREA MIDSECTION) + AREA BOTTOM] * DEPTH/6
94508.9 292975.0 54570.6 2.0
Total Designed Volume Available = 884109 CU. FT.
TEMPORARY STORAGE REQUIRED
DRAINAGE AREA:
Lagoon (top of dike)
Length * Width =
380.0 258.7 98305.1 square feet
Buildings (roof and lot water)
0.0 square feet Describe this area.
TOTAL DA 101955.0 square feet
Design temporary storage period to be 180 days.
5A. Volume of waste produced
Feces & urine production in gal./day per 135 lb. ALW • 1.37
Volume = 595350 lbs. ALW/135 lbs. ALW * 1.37 gal/day 180 days
Volume = 1087506 gals. or 145388.5 cubic feet
Volume of wash water
This is the amount of fresh water used for washing floors or volume
of fresh water used for a flush system. Flush systems that recirculate
the lagoon water are accounted for in 5A.
Volume =
Volume = 0.0 cubic feet
0.0 gallons/day * 180 days storage/7.48 gallons
per CF
5C. Volume of rainfall in excess of evaporation
Use period of time when rainfall exceeds evaporation by largest amount.
180 days excess rainfall = 7.0 inches
Volume = 7.0 in * DA / 12 inches per foot
Volume = 59473.8 cubic feet
elIPN
5D. Volume of 25 year - 24 hour storm
Volume =
7.5 inches / 12 inches per
Volume = 63721.9 cubic feet
TOTAL REQUIRED TEMPORARY STORAGE
6. SUMMARY
ego'
5A. 145389 cubic feet
5B. 0 cubic feet
5C. 59474 cubic feet
5D. 63722 cubic feet
TOTAL
268584 cubic feet
BEFORE BEGINNING EXCAVATION
LANDOWNER IS ADVISED TO
CONTACT ULOCO TO ASSURE THAT
UNDERGROUND UTILITIES ARE NOT
DESTROYED 1-800-632-4949
foot * DA
Temporary storage period > 180 days
> 7.0 inches
> 7.5.inches
> 1.0 feet
> 3.0 : 1
> 380.0 feet
> 4; 258.7 feet
> 49.8 feet
> 36.8 feet
> 86393.4 cu. f t .
> 884109 cu. ft.
Seasonal high watertable elevation (SHWT)===> -4- feet 45.1
Stop pumping elev. > 45.7 feet
Must be > or = to the SHWT elev. > 45:4 feettw.9
Must be > or = to min. req. treatment el.=> 42.8 feet
Required minimum treatment volume > 595350 cu. ft.
Volume at stop pumping elevation > 608842 cu. ft.
Start pumping elev. > 48.1 feet
Must be at bottom of freeboard & 25 yr. rainfall
Actual volume less 25 yr.- 24 hr. rainfall==> 820387 cu. ft.
Volume at start pumping elevation > 818870 cu. ft.
Required volume to be pumped > 204862 cu. ft.
Actual volume planned to be pumped > 210028 cu. ft.
Min. thickness of soil liner when required==> 1.9 feet
Rainfall in excess of evaporation
25 year - 24 hour rainfall
Freeboard
Side slopes
Inside top length
Inside top width
Top of dike elevation
Bottom of lagoon elevation
Total required volume
Actual design volume
7. DESIGNED BY: A.
Phi-, !aww).
DATE: ilioa/9Y-
APPROVED BY:
DATE:
NOTE: SEE ATTACHED WASTE UTILIZATION PLAN
COMMENTS: aI. 17istensOA w .d -cor. V0/1114t CO" pri+i, or,
LDyAv± SOLI, 4I 01. Qn110�
*
SCS DOES NOT CERTIFY THAT
EXCAVATION AND FILL
VOLUMES ARE CORRECT
SEEDING SPECIFICATIONS
AREA TO BE SEEDED: 5.0 ACRES
USE THE SEED MIXTURE INDICATED AS FOLLOWS:
300.0 LBS. FESCUE GRASS AT 60 LBS./ACRE
(BEST SUITED ON CLAYEY OR WET SOIL CONDITIONS)
SEEDING DATES: SEPTEMBER 1 TO NOVEMBER 30
FEBRUARY 1 TO MARCH 30
150.0 LBS. RYE GRAIN AT 30 LBS./ACRE (NURSERY FOR FESCUE)
0.0 LBS. 'PENSACOLA' BAHIA GRASS AT 60 LBS./ACRE
(SEE FOOTNOTE NO. 1)
SEEDING DATES: MARCH 15 TO JUNE 15
0.0 LBS. HULLED COMMON BERMUDA GRASS AT 8 LBS./ACRE
(SUITED FOR MOST SOIL CONDITIONS)
SEEDING DATES: APRIL 1 TO JULY 31
0.0 LBS. UNHULLED COMMON BERMUDA GRASS AT 10 LBS./ACRE
SEEDING DATES: JANUARY 1 TO MARCH 30 •
0.0 LBS. RYE GRASS AT 40 LBS./ACRE (TEMPORARY VEGETATION)
SEEDING DATES: DECEMBER 1 TO MARCH 30
LBS.
APPLY THE FOLLOWING:
5000.0 LBS. OF 10-10-10 FERTILIZER (1000 LBS./ACRE)
10.0 TONS OF DOLOMITIC LIME (2 TONS/ACRE)
500.0 BALES OF SMALL GRAIN STRAW (100 BALES/ACRE)
ALL SURFACE DRAINS SHOULD BE INSTALLED PRIOR TO SEEDING. SHAPE
ALL DISTURBED AREA IMMEDIATELY AFTER EARTH MOVING IS COMPLETED.
APPLY LIME AND FERTILIZER THEN DISK TO PREPARE A 3 TO 4 INCH
SMOOTH SEEDBED. APPLY SEED AND FIRM SEEDBED WITH A CULTIPACKER
OR SIMILAR EQUIPMENT. APPLY MULCH AND SECURE WITH A MULCH
ANCHORING TOOL OR NETTING.
1. PENSACOLA BAHIAGRASS IS SLOWER TO ESTABLISH THAN COMMON
BERMUDA GRASS. WHEN USING BAHIA, IT IS RECOMMENDED THAT 8
LBS./ACRE OF COMMON BERMUDA BE INCLUDED TO PROVIDE COVER
UNTIL BAHIAGRASS IS ESTABLISHED.
rr'N
■MMw■
MEW
_•
�I1
J;U. 1r 1IuTR -
1 a +' o'
..1- IG.►_T.
4.:7'0
1
—1
e_Let. 5 c�
r■
MEM
NEM
• le_ ' 1
ii • . figimnzwmww■
■ wwwwII■NEIMMI w■
Et
■www111ww■w■■■
_wzr.T.TaAa.. e
.o
n
1
Rev. S-i0
O. S. OtrAKTwltrIi %Jr Atirtll.ULlUkt
SOIL CONSERVATION SERVICE
•
SOIL INVESTIGATION TO DETERMINE SUITABILITY OF PROPOSED POND SITE
FARMER'S NAME R;AC y' k s r A.. a' DISTRICT f
3
• DATE 1 I - .11 - q I • COUNTY ay) i n '
. S. C. S. PHOTO SHEET NO. • WORK UNIT
WATERSHED AREA MEASUREMENTS
CROPLAND ACRES PASTURE ACRES
•
•
••.
WOODLAND•' ACRES TOTAL ' ' ACRES
POND CLASS
WORK UNIT CONSERVATIONIST
_
SKETCH OF PROPOSED•POND SHOWING WHERE BORINGS WERE MADE (Approx. scale 1"
__feet)
Locale reference point ,n center lint of darn and ldenl(fll on sketch. •
•
•
•
•
rI
��
•
J
.3
Lit
-
.
L►�
p
._
.
1::4
....r
L
C
O
•
;
o
.
.
•
'
01
, \ '
; i
SHOW
Mahe and list dans-sits
BORING NUMBER AND PROFILE
borings first Men
DEPTH
SCALE
(Continued on bath
and
wlscnr
spillway • ponded circa and borrow pit borings • scparois with vertical 1.4 !Me.
net J$ary) Show water table ekuations on darn site borings.
1
2
3
4
5
6
7
8
_
9
_
10
11
12
13
_
14
15T16
17
-
18
19
20.21
22
23
Q -t
3
C--.
M
' AA
rC
; •
SNP
1-2,
M
;SC
i
L.CM•
• S
•o
- -4
Sc
;
i)
ci,.,
SG
,Sc,
1.
r
ur c'
c
r
-
-
S-(,
fit.
-
6 - '
Sc-'.
L
t sc
(
sc
r
r
l .
S
. G
SC
SC
iM
'
•
1.J-,
' • - •
c,•-,
"vsM-
IP
piisci.,i,fts
M'
,.SM
SM'.ic
-
Id.- 1 i „`M- "F • sift' rJM-JP
BORINGS MADE BY 1:oc.°_ %tn •r SIGNATURE & TITLE A ' '%-•,rc r"7
tin Eeli2r
TYPES OF MATERIAL ENCOUNTERED IN BORINGS
(Use one of systems below)
UNIFIED CLASSIFICATION
r'GW- Well graded gravels; gravel, sand mix : •-
GP -Poorly graded gravels • _ •,
GM - Silty gravels; gravel -sand -silt mix
GC -Clayey gravels; gravel -sand -clay mix
SVi- Well graded sands; sand -gravel mix
SP - Poorly graded sands
SM -Silty sand
SC - Clayey sands; sand -clay mixtures
ML - Silts; silty, v. fine sands; sandy or clayey silt
CL - Clays of low to medium plasticity
CH -Inorganic clays of high plasticity
MH - Elastic silts
OL-Organic silts dad silty clays, low plasticity
OH -Organic clays, medium to high plasticity
1. Suitable material for embankment is available
USDA CLASSIFICATION
g - gravel • • • •
s -sand • •• •
yfs-very fine sand ......
sl - sandy loam
fsl -fine sandy .loan ' '
1-.loam.
. gl -gravelly. loam
si-silt
sil-silt loam
cl -clay loam
Sicl-silty clay loath
scl-sandy clay loam
sic -silty clay
c -clay
reverse side)
'Yes. EJ
REMARKS:
Gore dike dowh 4-r,hie fc
5.00d
w 1- k C. lsty ,
•
testy ra �L'r %q f•
No • 'acidic/de cohere located on the sketch oft
IA^ter iel1 11'DM !rS to 3,0 7'i- a-
2Explain hazards requiring special attention in design (Seepaoe. spr(n0..rock etc,)
GENERAL REMARKS:
/i'a
24 25
26
j
S r
29 30
31 32 33 -134
1
i
35
36
37 38
39
40
41 42, 43
3
4t;45
46
47 48
49 50
4
51
Is
EMERGENCY ACTION PLAN
PHONF. NI JMRFR S
DWQ 9/0 - 39q- 3goo
EMERGENCY MANAGEMENT SYSTEM 9i 0 - of 96 - A/ b o
SWCD 9/0- 02q6 -a/ao
NRCS 9io-aid - A/a/
This plan will be implemented in the event that wastes from your operation are leaking,
overflowing, or running off site. You should not wait until wastes reach surface waters or
leave your property to consider that you have a problem. You should make every effort to
ensure that this does not happen. This plan should be posted in an accessible location for all
employees at the facility. The following are some action items you should take.
1. Stop the release of wastes. Depending on the situation, this may or may not be possible.
Suggested responses to some possible problems are listed below.
A. Lagoon overflow -possible solutions are:
a. Add soil to berm to increase elevation of dam.
b. Pump wastes to fields at an acceptable rate.
c. Stop all flows to the lagoon immediately.
d. Call a pumping contractor.
e. Make sure no surface water is entering lagoon.
B. Runoff from waste application field -actions include:
a. Immediately stop waste application.
b. Create a temporary diversion to contain waste.
c. Incorporate waste to reduce runoff.
d. Evaluate and eliminate the reason(s) that caused the runoff.
e. Evaluate the application rates for the fields where runoff occurred.
C. Leakage from the waste pipes and sprinklers -action include:
a. Stop recycle pump.
b. Stop irrigation pump.
c. Close valves to eliminate further discharge.
d. Repair all leaks prior to restarting pumps.
D. Leakage from flush systems, houses, solid separators -action include:
1 December 18, 1996
a. Stop recycle pump.
b. Stop irrigation pump.
c. Make sure no siphon occurs.
d. Stop all flows in the house, flush systems, or solid separators.
e. Repair all leaks prior to restarting pumps.
E. Leakage from base or sidewall of lagoon. Often this is seepage as opposed to flowi;
a. Dig a small sump or ditch away from the embankment to catch all seepage, put
in a submersible pump, and pump back to the lagoon.
b. If holes are caused by burrowing animals, trap or remove animals and fill holes
and compact with a clay type soil.
c. Have a professional evaluate the condition of the side walls and lagoon bottom
as soon as possible.
2. Assess the extent of the spill and note any obvious damages.
a. Did the waste reach any surface waters?
b. Approximately how much was released and for what duration?
c. Any damage noted, such as employee injury, fish kills, or property damage?
d. Did the spill leave the property?
e. Does the spill have the potential to reach surface waters?
f. Could a future rain event cause the spill to reach surface waters?
g. Ate potable water wells in danger (either on or off of the property)?
h. How much reached surface waters?
3. Contact appropriate agencies.
a. During normal business hours, call your DWQ (Division of Water Quality) regional office;
Phone - - . After hours, emergency number. 919-733-3942. Your phone call
should include: your name, facility, telephone number, the details of the incident from item
2 above, the exact location of the facility, the location or direction of movement of the spill,
weather and wind conditions. The corrective measures that have been under taken, and the
seriousness of the situation.
b. If spill leaves property or enters surface waters, call local EMS phone number
c. Instruct EMS to contact local Health Department.
d. Contact CES, phone number - - , local SWCD office phone number , and
local NRCS office for advice/technical assistance phone number -
4. If none of the above works call 911 or the Sheriffs Department and explain your problem
to them and ask that person to contact the proper agencies for you.
2 December 18, 1996
5. Contact the contractor of your choice to begin repair of problem to minimize off -site
damage.
a. Contractors Name: Aoc: ``'-Y Se C •
b. Contractors Address: " (IC.- a)4 % 144 f+AdC Him
c. Contractors Phone: ZA'2.- 5%6 - 2- `F -
6. Contact the technical specialist who certified the lagoon (NRCS, Consulting Engineer, etc.
a. Name:
b. Phone:
sery �.
tem, te-eMAC. ciy
7. Implement procedures as advised by DWQ and technical assistance agencies to rectify
the damage, repair the system, and reassess the waste management plan to keep
problems with release of wastes from happening again.
3 December 18, 1996
OPERATION & MAINTENANCE PLAN
Proper lagoon liquid management should be a year-round priority. It is especially
important to manage levels so that you do not have problems during extended rainy and
wet periods.
Maximum storage capacity should be available in the lagoon for periods when the
receiving crop is dormant (such as wintertime for bermudagrass) or when there are
extended rainy spells such as the thunderstorm season in the summertime. This means
that at the first signs of plant growth in the later winter/early spring, irrigation according to
a farm waste management plan should be done whenever the land is dry enough to
receive lagoon liquid. This will make storage space available in the lagoon for future wet
periods. In the late summer/early fall the lagoon should be pumped down to the low
marker (see Figure 2-1) to allow for winter storage. Every effort should be made to
maintain the lagoon close to the minimum liquid level as long as the weather and waste
utilization plan will allow it.
Waiting until the lagoon has reached its maximum storage capacity before starting to
irrigate does not leave room for storing excess water during extended wet periods.
Overflow from the lagoon for any reason except a 25-year, 24-hour storm is a violation of
state law and subject to penalty action.
The routine maintenance of a lagoon involves the following:
Maintenance of a vegetative cover for the dam.
Fescue or common bermudagrass are the most common vegetative
covers. The vegetation should be fertilized each year, if needed, to
maintain a vigorous stand. The amount of fertilizer applied should be
based on a soils test, but in the event that it is not practical to obtain
a soils test each year, the lagoon embankment and surrounding areas
should be fertilized with 800 pounds per acre of 10-10-10, or
equivalent.
Brush and trees on the embankment must be controlled. This may be
done by mowing, spraying, grazing, chopping, or a combination of
these practices. This should be done at least once a year and
possibly twice in years that weather conditions are favorable for
heavy vegetative growth.
NOTE: If vegetation is controlled by spraying, the herbicide must not be allowed to enter
the lagoon water. Such chemicals could harm the bacteria in the lagoon that are treating
the waste.
Maintenance inspections of the entire lagoon should be made during the initial filling of
the lagoon and at least monthly and after major rainfall and storm events. Items to be
checked should include, as a minimum, the following:
Waste Inlet Pipes, Recycling Pipes, and Overflow Pipes ---look for:
1. separation of joints
2. cracks or breaks
3. accumulation of salts or minerals
4. overall condition of pipes
Lagoon surface ---look for:
1. undesirable vegetative growth
2. floating or lodged debris
Embankment ---look for:
1. settlement, cracking, or "jug" holes
2. side slope stability ---slumps or bulges
3. wet or damp areas on the back slope
4. erosion due to lack of vegetation or as a result of wave action
5. rodent damage
Larger lagoons may be subject to liner damage due to wave action caused by strong
winds. These waves can erode the lagoon sidewalis, thereby weakening the lagoon dam.
A good stand of vegetation will reduce the potential damage caused by wave action. If
wave action causes serious damage to a lagoon sidewall, baffles in the lagoon may be
used to reduce the wave impacts.
Any of these features could lead to erosion and weakening of the dam. If your lagoon has
any of these features, you should call an appropriate expert familiar with design and
construction of waste lagoons. You may need to provide a temporary fix if there is a threat
of a waste discharge. However, a permanent solution should be reviewed by the
technical expert. Any digging into a lagoon dam with heavy equipment is a serious
undertaking with potentially serious consequences and should not be conducted unless
recommended by an appropriate technical expert.
Transfer Pumps ---check for proper operation of:
1. recycling pumps
2. irrigation pumps
Check for leaks, loose fittings, and overall pump operation. An unusually loud or grinding
noise, or a large amount of vibration, may indicate that the pump is in need or repair or
replacement.
NOTE: Pumping systems should be inspected and operated frequently enough so that you
are not completely "surprised" by equipment failure. You should perform your pumping
system maintenance at a time when your lagoon is at its low level. This will allow some
safety time should major repairs be required. Having a nearly full lagoon is not the time
to think about switching, repairing , or borrowing pumps. Probably, if your lagoon is full,
your neighbor's lagoon is full also. You should consider maintaining an inventory of spare
parts or pumps.
Surface water diversion features are designed to carry all surface
drainage waters (such as rainfall runoff, roof drainage, gutter outlets,
and parking lot runoff) away from your lagoon and other waste
treatment or storage structures. The only water that should be
coming from your lagoon is that which comes from your flushing
(washing) system pipes and the rainfall that hits the lagoon directly.
You should inspect your diversion system for the following:
1. adequate vegetation
2. diversion capacity
3. ridge berm height
Identified problems should be corrected promptly. It is advisable to inspect your system
during or immediately following a heavy rain. If technical assistance is needed to
determine proper solutions, consult with appropriate experts.
You should record the level of the lagoon just prior to when rain is predicted, and then
record the level again 4 to 6 hours after the rain (assumes there is no pumping). This will
give you an idea of how much your lagoon level will rise with a certain rainfall amount
(you must also be recording your rainfall for this to work). Knowing this should help in
planning irrigation applications and storage. If your lagoon rises excessively, you may
have an inflow problem from a surface water diversion or there may be seepage into the
lagoon from the surrounding land.
Lagoon Operation
Startup:
1. Immediately after construction establish a complete sod cover on bare soil
surfaces to avoid erosion.
2. Fill new lagoon design treatment volume at least half full of water before
waste loading begins, taking care not to erode lining or bank slopes.
3. Drainpipes into the lagoon should have a flexible pipe extender on the
end of the pipe to discharge near the bottom of the lagoon during initial
filling or another means of slowing the incoming water to avoid erosion of
the lining.
4. When possible, begin loading new lagoons in the spring to maximize
bacterial establishment (due to warmer weather).
5. It is recommended that a new lagoon be seeded with sludge from a healthy
working swine lagoon in the amount of 0.25 percent of the full lagoon
liquid volume. This seeding should occour at least two weeks prior to the
addition of wastewater.
6. Maintain a periodic check on the lagoon liquid pH. If the pH falls below
7.0, add agricultural lime at the rate of 1 pound per 1000 cubic feet of
lagoon liquid volume until the pH rises above 7.0. Optimum lagoon liquid
pH is between 7.5 and 8.0.
7. A dark color, lack of bubbling, and excessive odor signals inadequate
biological activity. Consultation with a technical specialist is recommended
if these conditions occur for prolonged periods, especially during the warm
season.
Loading:
The more frequently and regularly that wastewater is added to a lagoon, the better the
lagoon will function. Flush systems that wash waste into the lagoon several times daily are
optimum for treatment. Pit recharge systems, in which one or more buildings are drained
and recharged each day, also work well.
rt‘
Practice water conservation —minimize building water usage and
spillage from leaking waterers, broken pipes and washdown through
proper maintenance and water conservation.
Minimize feed wastage and spillage by keeping feeders adjusted. This
will reduce the amount of solids entering the lagoon
Management:
Maintain lagoon liquid level between the permanent storage level and
the full temporary storage level.
Place visible markers or stakes on the lagoon bank to show the
minimum liquid level and the maximum liquid lever (Figure 2-1).
Start irrigating at the earliest possible date in the spring based on
nutrient requirements and soil moisture so that temporary storage
will be maximized for the summer thunderstorm season. Similarly,
irrigate in the late summer/early fall to provide maximum lagoon
storage for the winter.
The lagoon liquid level should never be closer than 1 foot to the lowest
point of the dam or embankment.
Do not pump the lagoon liquid level lower that the permanent storage
level unless you are removing sludge.
Locate float pump intakes approximately 18 inches underneath the liquid
surface and as far away from the drainpipe inlets as possible.
Prevent additions of bedding materials, long-stemmed forage or vegetation,
molded feed, plastic syringes, or other foreign materials into the lagoon.
Frequently remove solids from catch basins at end of confinement houses or
wherever they are installed.
. Maintain strict vegetation, rodent, and varmint control near lagoon edges.
Do not allow trees or large bushes to grow on lagoon dam or embankment.
Remove sludge from the lagoon either when the sludge storage capacity is
;full or before it fills 50 percent of the permanent storage volume.
If animal production is to be terminated, the owner is responsible for
obtaining and implementing a closure plan to eliminate the possibility of a
pollutant discharge.
Sludge Removal:
Rate of lagoon sludge buildup can be reduced by:
rrg
proper lagoon sizing,
mechanical solids separation of flushed waste,
• gravity settling of flushed waste solids in an appropriately designed basin, or
. minimizing feed wastage and spillage.
Lagoon sludge that is removed annually rather than stored long term will:
have more nutrients,
have more odor, and
require more land to properly use the nutrients.
Removal techniques:
Hire a custom applicator.
Mix the sludge and lagoon liquid with a chopper -agitator impeller
pump through large -bore sprinkler irrigation system onto nearby cropland;
and soil incorporate.
Dewater the upper part of lagoon by irrigation onto nearby cropland or
forageland; mix remaining sludge; pump into liquid sludge applicator; haul
and spread onto cropland or forageland; and soil incorporate.
Dewater the upper part of lagoon by irrigation onto nearby cropland or
forageland; dredge sludge from lagoon with dragline or sludge barge; berm
an area beside lagoon to receive the sludge so that liquids can drain back
into lagoon; allow sludge to dewater; haul and spread with manure spreader
onto cropland or forageland; and soil incorporate.
Regardless of the method, you must have the sludge material analyzed for waste
constituents just as you would your lagoon water. The sludge will contain different
nutrient and metal values from the liquid. The application of the sludge to fields will be
limited by these nutrients as well as any previous waste applications to that field and crop
requirement. Waste application rates will be discussed in detail in Chapter 3.
When removing sludge, you must also pay attention to the liner to prevent damage. Close
attention by the pumper or drag -line operator will ensure that the lagoon liner remains
intact. If you see soil material or the synthetic liner material being disturbed, you should
stop the activity immediately and not resume until you are sure that the sludge can be
removed without liner injury. If the liner is damaged it must be repaired as soon as
possible.
Sludge removed from the lagoon has a much higher phosphorus and heavy metal content
than liquid. Because of this it should probably be applied to land with low phosphorus
and metal levels, as indicated by a soil test, and incorporated to reduce the chance of
erosion. Note that if the sludge is applied to fields with very high soil -test phosphores, it
should be applied only at rates equal to the crop removal of phosphorus. As with other
wastes, always have your lagoon sludge analyzed for its nutrient value.
The application of sludge will increase the amount of odor at the waste application site.
Extra precaution should be used to observe the wind direction and other conditions which
could increase the concern of neighbors.
Possible Causes of Lagoon' Failure
Lagoon failures result in the unplanned discharge of wastewater from the structure. Types
of failures include leakage through the bottom or sides, overtopping, and breach of the
dam. Assuming proper design and construction, the owner has the responsibility for
ensuring structure safety. Items which may lead to lagoon failures include:
Modification of the lagoon structure ---an example is the placement of a pipe
in the dam without proper design and construction. (Consult an expert in
lagoon design before placing any pipes in dams.)
Lagoon liquid levels ---high levels are a safety risk.
Failure to inspect and maintain the dam.
Excess surface water flowing into the lagoon.
Liner integrity ---protect from inlet pipe scouring, damage during sludge
removal, or rupture from lowering lagoon liquid level below groundwater
table.
NOTE: If lagoon water is allowed to overtop the dam, the moving water will soon cause
gullies to form in the dam. Once this damage starts, it can quickly cause a large discharge
of wastewater and possible dam failure.
Insect Control Checklist for Animal Operations
Source Cause BMPs to Minimize Insects Site Specific Practices
Liquid Systems
Flush Gutters
• Accumulation of Solids 171' Flush system is designed and operated sufficiently to
remove accumulated solids from gutters as designed;
gI Remove bridging of accumulated solids at discharge
Lagoons and Pits • Crusted Solids
e Maintain lagoons, settling basins and pits where
pest breeding is apparent to minimize the crusting
of solids to a depth of no more than 6 - 8 inches
over more than 30% of surface.
Excessive Vegetative • Decaying vegetation I "Maintain vegetative control along banks of lagoons
Growth and other impoundments to prevent accumulation of
decaying vegetative matter along waters edge on
impoundment's perimeter.
nr„ Svctpms
Feeders • Feed Spillage O Design, operate and maintain feed systems(e.g.,
bunkers and troughs) to minimize the accumulation
of decaying.wastage.
O Clean up spillage on a routine basis (e.g., 7 - 10 day
interval during summer; 15-30 day interval during
winter) .
Feed Storage • Accumulation of feed residues
AMIC - November 11, 1996, Page 1
O Reduce moisture accumulation within and around
immediate perimeter of feed storage areas by
insuring drainage away from site and/or providing
adequate containment (e.g., covered bin for
brewer's grain and similar high moisture grain
O kpr and remove or break up accumulated
solids in filter strips around feed storage as needed.
Source Cause BMPs to Minimize Insects Site Specific Practices
Animal Holding Areas • Accumulations of animal wastes
and feed wastage
O Eliminate low areas that trap moisture along fences
and other locations where waste accumulates and
disturbance by animals is minimal.
O Maintain fence rows and filter strips around
animal holding areas to minimize accumulations
of wastes (i.e. inspect for and remove or break up
accumulated solids as needed.
Dry Manure Handling • Accumulations of animal wastes 0 Remove spillage on a routine basis (e.g., 7-10 day
Systems interval during summer; 15-30 day interval during
winter) where manure is loaded for land application
O Pi6Vfinifil adequate drainage around manure
stockpi les.
O Inspect for an remove or break up accumulated
wastes in filter strips around stockpiles and manure
' handling areas as needed.
For more information contact the Cooperative Extension Service, Department of Entomology, Box 7613, North Carolina State University, Raleigh, NC
27695-7613
AMIC - November 11, 1996, Page 2
Swine Farm Waste Management Odor Control Checklist
Source Cause BMPs to Minimize Odor Site Specific Practices
Farmstead • Swine Production ET Vegetative or wooded buffers;
O Recommended best management practices;
f Good judgement and common sense
Animal body surfaces
• Dirty manure -covered animals 17r-Dry floors
Floor surfaces • Wet manure -covered floors
Manure collection pits • Urine;
• Partial microbial decomposition
'Slotted floors;
'Waterers located over slotted floors;
O Feeders at high end of solid floors;
'Scrape manure buildup from floors;
'Underfloor ventilation for drying
ET Frequent manure removal by flush, pit recharge, or
scrape;
Ir Underfloor ventilation
Ventilation exhaust fans • Volatile gases;
• Dust
0/Fan maintenance;
f2r Efficient air movement
Indoor surfaces • Dust
L 'Washdown between groups of animals;
O Feed additives;
O Feed covers;
O Feed delivery downspout extenders to feeder
covers
Flush tanks
• Agitation of recycled lagoon liquid 0 Flush tank covers;
while tanks are filling 0 Extend fill to near bottom of tanks with
anti -siphon vents
Flush alleys
• Agitation during wastewater 0 Underfloor flush with underfloor ventilation
conveyance
Pit recharge points • Agitation of recycled lagoon liquid 0 Extend recharge lines to near bottom of pits with
while pits are filling anti -siphon vents
Lift stations • Agitation during sump tank filling 0 Sump tank covers
and drawdown
AMOC - November 11, 1996, Page 3
Source
Cause
BMPs to Minimize Odor Site Specific Practices
Outside drain collection or
junction boxes
• Agitation during wastewater
conveyance
O Box covers
End of drainpipes at lagoon • Agitation during wastewater
conveyance
Lagoon surfaces
Irrigation sprinkler nozzles
• Volatile gas emission;
• Biological mixing;
• Agitation
• High pressure agitation;
• Wind drift
Storage tank or basin • Partial microbial decomposition;
surface • Mixing while filling;
• Agitation when emptying
Settling basin surface
Manure, slurry or sludge
spreader outlets
Uncovered manure, slurry
or sludge on field surfaces
•
•
•
•
•
Partial microbial decomposition;
Mixing while filling;
Agitation when emptying
Agitation when spreading;
Volatile gas emissions
• Volatile gas emissions while
drying
Dead animals • Carcass decomposition
AMOC - November 11, 1996, Page 4
O Extend discharge point of pipes underneath
lagoon liquid level
Er Proper lagoon liquid capacity;
• Correct lagoon startup procedures;
Minimum surface area -to -volume ratio;
l3 Minimum agitation when pumping;
O Mechanical aeration;
O Proven biological additives
'irrigate on dry days with little or no wind:
Cr.—Minimum recommended operating pressure:
12K-Pump intake near lagoon liquid surface:
O Pump from second stage lagoon
❑ Bottom or midlevel loading:
❑ Tank covers:
O Basin surface mats of solids:
O Proven biological additives or oxidants
O Extend drainpipe outlets underneath liquid level;
11 Remove settled solids regularly
MV-Soil injection of slurry/sludges;
Izlt"/Wash residual manure from spreader after use;
n Proven biological additives or oxidants
• Soil injection of slurry/sludges;
Pt' Soil incorporation within 48 hrs.;
Ig' Spread in thin uniform lavers for rapid drying:
r1 Proven biological additives or oxidants
rl Proper disposition of carcasses
Source
Cause
BMPs to Minimize Odor
Site Specific Practices
Dead animal disposal pits
Incinerators
Standing water around
facilities
• Carcass decomposition
• Incomplete combustion
• Improper drainage;
• Microbial decomposition of
organic matter
n Complete covering of carcasses in burial pits;
n Proper location/construction of disposal pits
n Secondary stack burners
a'Grade and landscape such that water drains away
from facilities
Mud tracked onto public • Poorly maintained access roads
roads from farm access
Farm access road maintenance
Additional Information:
Swine Manure Management; .0200 Ru1eBMP Packet
Swine Production Farm Potential Odor Sources and Remedies; EBAE Fact Sheet
Swine Production Facility Manure Management: Pit Recharge - Lagoon Treatment; EBAE 128-88
Swine Production Facility Manure Management: Underfloor Flush - Lagoon Treatment; EBAE 129-88
Lagoon Design and Management for Livestock Manure Treatment and Storage; EBAE 103-88
Calibration of Manure and Wastewater Application Equipment; EBAE Fact Sheet
Controlling Odors from Swine Buildings; PIH-33
Environmental Assurance Program: NPPC Manual
Options for Managing Odor; a report from the Swine Odor Task Force
Nuisance Concerns in Animal Manure Management: Odors and Flies; PRO107, 1995 Conference Proceedings
AMOC - November 11, 1996, Page 5
Available From:
NCSU, County Extension Center
NCSU - BAE
NCSU -BAE
NCSU - BAE
NCSU - BAE
NCSU - BAE
NCSU - Swine Extension
NC Pork Producers Assoc.
NCSU - Agri Communications
Florida Cooperative Extension