Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
090132_Permit Renewal Application 2019_20190410
State of North Carolina Department of Environmental Quality Division of Water Resources Animal Waste Management Systems Request for Certification of Coverage Facility Currently covered by an Expiring Sate Non -Discharge General Permit On September 30, 2019, the North Carolina State Non -Discharge General Permits for Animal Waste Management Systems will expire. As required by these permits, facilities that have been issued Certificates of Coverage to operate under these State Non -Discharge General Permits must apply for renewal at least 180 days prior to their expiration date. Therefore, all applications must be received by the Division of Water Resources by no later than April 3, 2019. Please do not leave any question unanswered. Please verify all information and make any necessary corrections below. Application must be signed and dated by the Permittee. 1. Farm Number: 09-0132 Certificate Of Coverage Number: AWS090132 2. Facility Name: Terra Nova 3. Landowner's Name (same as on the Waste Management Plan): Willie L Beard 4. Landowner's Mailing Address: 3281 Rosindale Rd City: Clarkton State: NC Zip: 28433 Telephone Number: 910-520-3749 Ext. E-mail: 5. Facility's Physical Address: 580 Rosindale Rd City: Clarkton State: NC Zip: 28433 6. County where Facility is located: Bladen 7. Farm Manager's Name (if different from Landowner): 8. Farm Manager's telephone number (include area code): 9. Integrator's Name (if there is not an Integrator, write "None"): Murphy -Brown LLC 10. Operator Name (OIC): Willie L. Beard Phone No.: 910-520-3749 OIC #: 16271 11. Lessee's Name (if there is not a Lessee, write "None"): 12. Indicate animal operation type and number: Current Permit: Operations Type Allowable Count Swine - Feeder to Finish 3,672 Operation Types: Swine Cattle Dry Poultry Other Types Wean to Finish Dairy Calf Non Laying Chickens Horses - Horses Wean to Feeder Dairy Heifer Laying Chickens Horses - Other Farrow to Finish Milk Cow Pullets Sheep - Sheep Feeder to Finish Dry Cow Turkeys . Sheep - Other Farrow to Wean Beef Stocker Calf Turkey Pullet Farrow to Feeder Beef Feeder Boar/Stud Beef Broad Cow Wet Poultry Gilts Other Non Laying Pullet Other Layers 13. Waste Treatment and Storage Lagoons (Verify the following information is accurate and complete. Make all necessary corrections and provide missing data.) Structure Name Estimated Date Built Liner Type (Clay, Synthetic, Unknown) Capacity Feet) Estimated Surface Area (Square Feet) Design Freeboard "Redline" (Inches) 1 7j28142 (I:.:! �(Cuubic Li7f(ta3 -7)too 19.00 1 I9.00 2 q ju/e 4 ('_iti- ZQtia�)1 7 14,,;2D 19.00 I V 6.4390,7 Mail one (1) copy of the Certified Animal Waste Management Plan (CAWMP) with this completed and signed application as required by NC General Statutes 143-215.10C(d) to the address below. The CAWMP must include the following components: 1. The most recent Waste Utilization Plan (WUP) signed bs the owner and a certified technical specialistcontaining: a. The method by which waste is applied to the disposal fields (e.g. irrigation, injection, etc.) b. A map of every field used for land application (for example: irrigation map) c. The soil series present on every land application field d. The crops grown on every land application field e. The Realistic Yield Expectation (RYE) for every crop shown in the WUP f. The maximum PAN to be applied to every land application field g. The waste application windows for every crop utilized in the WUP h. The required NRCS Standard specifications 2. A site map/schematic 3. Emergency Action Plan 4. Insect Control Checklist with chosen best management practices noted 5. Odor Control Checklist with chosen best management practices noted 6. Mortality Control Checklist with selected method noted - Use the enclosed updated Mortality Control Checklist 7. Lagoon/storage pond capacity documentation (design, calculations, etc.) Please be sure the above table is accurate and complete. Also provide any site evaluations, wetland determinations, or hazard classifications that may be applicable to your facility. 8. Operation and Maintenance Plan If your CAWMP includes any components not shown on this list, please include the additional components with your submittal. (e.g. composting, digesters, waste transfers, etc.) As a second option to mailing paper copies of the application package, you can scan and email one signed copy of the application and all the CAWMP items above to: 2019PermitRenewal@ncdenr.gov I attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that, if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application may be subject to civil penalties up to $25,000 per violation. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment of not more than 5 years, or both for a similar offense.) Printed Name of Signing Official (Landowner, or if multiple Landowners all landowners should sign. If Landowner is a corporation, signature should be byi,a principal executive officer of the corporation): Name: J C) r��i3r JQV J4 9V 1 I 1 t P Title: �W }}f� Signature: IN1-' 1- 1 Date: 3 ,as 19 Name: Title: Signature: Date: Name: Title: Signature: Date: THE COMPLETED APPLICATION SHOULD BE SENT.TO.THE FOLLOWING ADDRESS: NCDEQ-DWR Animal Feeding Operations Program 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Telephone number: (919) 707-9100 E-mail: 2019PermitRenewal@ncdenr.gov FORM: RENEWAL -STATE GENERAL 02/2019 ROY COOPER Gaaernot MICHAEL S. REGAN Secretary L1NDA CULPEPPER Oirettor NORTH CAROLINA Envfronntentaf Quality February 27, 2019 Willie L Beard Terra Nova 3281 Rosindale Rd Clarkton, NC 28433 Subject: Application for Renewal of Coverage for Expiring State General Permit Dear Permittee: APR 0' 12019 Your facility is currently approved for operation under one of the Animal Waste Operation State Non -Discharge General Permits, which expire on September 30, 2019. Copies of the new animal waste operation State Non -Discharge General Permits are available at https://den.nc.gov/about/divisions/water-resources/water-qualit'-rezional-operations/afo or by writing or calling: NCDEQ-DWR Animal Feeding Operations Program 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Telephone number: (919) 707-9100 In order to assure ►our continued coverage under the State Non -Discharge General Permits. you must submit an application for permit coverage to the Division. Enclosed you will find a "Reouest for Certificate of Coverage Facility Currently Covered b■ an Expiring State Non -Discharge General Permit." The application form must be completed, siened and returned by April 3, 2019. Please note that you must include one i11 con of the Certified Animal Waste Management Plan (CAWMP) with the completed and siened application form. A list of items included in the CAWMP can be found on page 2 of the renewal application form. Failure to request renewal of your coverage under a general permit within the time period specified may result in a civil penalty. Operation of your facility without coverage under a valid general permit would constitute a violation of NCGS 143-215.1 and could result in assessments of civil penalties of up to $25,000 per day. If you have any questions about the State Non -Discharge General Permits, the enclosed application, or any related matter please feel free to contact the Animal Feeding Operations Branch staff at 919-707-9100. Enclosures cc (w/o enclosures): Sincerely, Jon Risgaard, Section Chief Animal Feeding Operations and Groundwater Section Fay etteville Regional Office, Water Quality Regional Operations Section Bladen County Soil and Water Conservation District AFOG Section Central Files - AWS090132 Murph' -Brown LLC North. Caro ra Depa trnert of Env roarrenta qua ty I D-vs or of Water Resorraes 0.41• 512 N. Ss abury St. 11e'3e Na Sery as Cents, I Ra ash, North Caro, -pa 2789E-1S3S 919.737.9MC WASTE UTILIZATION PLAN PRODUCER: Terrallova LOCATION: 3281 Rosindale Rd. Clarkton, NC 28433 TELEPHONE: (910) 645 4840 TYPE OPERATION: Feeder - Finish NUMBER OF ANIMALS: 3672 (Design Capacity) The waste from your animal facility must be land applied at a specified rate to prevent pollution of surface and/or groundwater. The plant nutrients in the animal waste should be used to reduce the amount of commercial fertilizer required for the crops in the fields where the waste is to be applied. This waste utilization plan uses nitrogen as the limiting nutrient. Waste should be analyzed before each application cycle. Annual soil tests are strongly encouraged so that all plant nutrients can be balanced for realistic yields of the crop to be grown. Several factors are important in implementing your waste utilization plan in order to maximize the fertilizer value of the waste and to ensure that it is applied in an environmentally safe manner. Always apply waste based on the needs of the crop to be grown and the nutrient content of the waste. Do not apply more nitrogen than the crop can utilize. Soil types are important as they have different infiltration rates, leaching potentials, cation exchange capacities, and available water holding capacities. Normally waste shall not be applied to land eroding at greater than 5 tons per acre per year. With special precautions, waste may be applied to land eroding at up to 10 tons per year. Do not apply waste on saturated soils, when it is raining, or when the surface is frozen. Either of these conditions may result in runoff to surface waters which is not allowed under DEM regulations. Wind conditions should also be considered to avoid drift and downwind odor problems. To maximize the value of nutrients for crop production and to reduce the potential for pollution, the waste should be applied to a growing crop or applied to bare ground not more than 30 days prior to planting. Injecting the waste or disking will conserve nutrients and reduce odor problems. The estimated acres needed to apply the animal waste is based on typical nutrient content for this type of facility. Acreage requirements should be based on the waste analysis report from your waste management facility. Attached you will find information on proper sampling techniques, preparation, and transfer of waste samples to the lab for analysis. This waste utilization plan, if carried out, meets the requirements for compliance with 15A NCAC 2H.0217 adopted by the Environmental Management Commission. Page 1 ...... .... WASTE UTILIZATION PLAN Amount of Waste Produced Per Year (gallons. ft. tons. etc.) 3,672 animals X 1,2 (tons) waste/animal/year = 6,977 (tons) waste/year. Amount of Plant Available Nitrogen (PAN) Produced Per Year 3,672 animals X 2.3 lbs. PAN/animal/year = 8,446 lbs. PAN/year. (PAN from N.C. Guide Std. 633) Tech Applying the above amount of waste is a big job. You should plan time and have appropriate equipment to apply the waste in a timely manner The following acreage will be needed for waste application based on the crop to be grown and surface application: Tract Field* Soil # No. Type T8197 T8197 T8197 T8197 1 1 2 2 ExA ExA ExA/AyB ExA/AyB Table 1: ACRES OWNED BY PRODUCER Crop Lbs. N Acres Lbs. N Month of Per Acre Utilized Application Bermuda(G) Matua(G) Bermuda(G) Matua(G) Total 275 155 270 150 14.61 14.61 5.25 5.25 4018.85 2264.55 1417.5 787.5 April - Sept. Oct. - March April - Sept. Oct. - March 19.86 8,488.40 *This N is from animal waste only. If nutrients from other sources such as commercial fertilizer are applied, they must be accounted for. LV must be based on realistic yield expectation. NOTE: The applicator is cautioned that P and K may be over applied while meeting the N requirements. Beginning in 1996 the Coastal Zone Management Act will require farmers in some eastern counties of North Caroline to have a nutrient management plan that addresses all nutrients. This plan only addresses Nitrogen. Page 2 -WASTE1JTILI14TION .PLAN. Table 2: ACRES WITH AGREEMENT OR LONG TERM LEASE (Agreement with adjacent landowner must be attached) (Required only if operator does not own adequate land [see Required Specification 2]) Tract Field Soil Crop Lbs. N Acres Lbs. N Month of # No. Type Per Acre* Utilized Application * See footnote for Table 1. Total Totals from above Tables Acres Lbs. N Utilized Table 1 19.86 Table 2 0.00 Total 19.86 Amount of N Produced Surplus or Deficit 8,488 8,488 8,446 (43) NOTE: The Waste Utilization Plan must contain provisions for periodic land application of sludge at agronomic rates. The sludge will be nutrient rich and will require precautionary measures to prevent over application of nutrient or other elements. Page 3 WASTE UTILIZATION PLAN See attached map showing the fields to be used for the utilization of waste water. Application of Waste by Irrigation Crop Field No. Soil Type Application Rate (In/Hr. Application Amount (In. 1 ExA Bermuda 0.35 0.75 2 ExA/AyB Bermuda THIS TABLE IS NOT NEEDED IF WASTE IS NOT BEING APPLIED BY IRRIGATION, HOWEVER A SIMILAR TABLE WILL BE NEEDED FOR DRY LITTER OR SLURRY. Your facility is designed for 180 days of temporary storage and the temporary storage must be removed on the average of once every E MONTHS. In no instance should the volume of waste being stored in your structure exceed Elevation *see lagoon des'grl. Call the local Natural Resources Conservation Service (formerly Soil Conservation Service) or Soil and Water Conservation District office after you receive the waste analysis report for assistance in determining the amount per acre to apply and the proper application rate prior to applying the waste. Narrative of operation: Acres shown are 'wetted' acres of fields shown. For matua overseeded into bermuda, the management guidelines supplied should be followed by the grower. All land may be grazed. Page 4 . WASTE UTILIZATION:: PLAN , REQUIRED SPECIFICATIONS 1 Animal waste shall not reach surface waters of the state by runoff, drift, manmade conveyances, direct application, or direct discharge during operation or land application. Any discharge of waste which reaches surface water is prohibited. 2 There must be documentation in the design folder that the producer either owns or has an agreement for use of adequate land on which to properly apply the waste. If the producer does not own adequate land to properly dispose of waste, he/she shall provide a copy of an agreement with a landowner who is within a reasonable proximity, allowing him/her the use of the land for waste application. It is the responsibility of the owner of the facility to secure an update of the Waste Utilization Plan when there is a change in the operation, increase in the number of animals, method of utilization, or available land. 3 Animal waste shall be applied to meet, but not exceed, the nitrogen needs for realistic crop yields based on soil type, available moisture, historical data, climatic conditions, and level of management, unless there are regulations that restrict the rate of application for other nutrients. 4 Animal waste shall be applied to land eroding Tess than 5 tons per acre per year. Waste may be applied to land that is eroding at 5 or more tons, but less than 10 tons per acre per year providing grass filter strips are installed where runoff leaves the field. (See FOTG Standard 393 - Filter Strip). 5 Odors can be reduced by injecting the waste or disking after waste application. Waste should not be applied when there is danger of drift from the irrigation field. 6 When animal waste is to be applied on acres subject to flooding, it will be soil incorporated on conventionally tilled cropland. When applied to conservation tilled crops or grassland, the waste may be broadcast provided the application does not occur during a season prone to flooding. (See "Weather and Climate in North Carolina" for guidance.) 7 Liquid waste shall be applied at rates not to exceed the soil infiltration rate such that runoff does not occur offsite or to surface waters and in a method which does not cause drift from the site during application. No ponding should occur in order to control odor or flies. 8 Animal waste shall not be applied to saturated soils, during rainfall events, or when the surface is frozen. Page 5 WASTE UTILIZATION PLAN REQUIRED SPECIFICATIONS (continued) 9 Animal waste shall be applied on actively growing crops in such a manner that the crop is not covered with waste to a depth that would inhibit growth. The potential for salt damage from animal waste should also be considered. 10 Waste nutrients shall not be applied in fall or winter for spring planted crops on soils with a high potential for leaching. Waste nutrient loading rates on these soils should be held to a minimum and a suitable winter cover crop planted to take up released nutrients. Waste shall not be applied more than 30 days prior to planting of the crop or forages breaking dormancy. 11 Any new swine facility sited on or after October 1, 1995 shall comply with the following: The outer perimeter of the land area onto which waste is applied from a lagoon that is a component of a swine farm shall be at least 50 feet from any residential property boundary and from any perennial stream or river (other than an irrigation ditch or canal. Animal waste other than swine waste from facilities sited on or after October 1, 1995), shall not be applied closer than 25 feet to perennial waters. (See Standard 393 - Filter Strips). 12 Animal waste shall not be applied closer than 100 feet to wells. 13 Animal waste shall not be applied closer than 200 feet of dwellings other than those owned by the landowner. 14 Waste shall be applied in a manner not to reach other property and public right-of-ways. 15 Animal waste shall not be discharged into surface waters, drainageways, or wetlands by discharge or by over -spraying. Animal waste may be applied to prior converted wetlands provided they have been approved as a land application site by a "technical specialist". Animal waste shall not be applied on grassed waterways that discharge directly into water courses, and on other grassed waterways, waste shall be applied at agronomic rates in a manner that courses no runoff or drift from the site. 16 Domestic and industrial waste from washdown facilities, showers, toilets, sinks, etc., shall not be discharged into the animal waste management system. Page 6 WASTE UTILIZATIONPLAN REQUIRED SPECIFICATIONS (continued) 17 A protective cover of appropriate vegetation will be established on all disturbed areas (lagoon embankments, berms, pipe runs, etc.). Areas shall be fenced as necessary to protect the vegetation. Vegetation such as trees, shrubs, and other woody species, etc., are limited to areas where considered appropriate. Lagoon areas should be kept mowed and accessible. Berms and structures should be inspected regularly for evidence of erosion, leakage or discharge. 18 If animal production at the facility is to be suspended or terminated, the owner is responsible for obtaining and implementing a "closure plan" which will eliminate the possibility of an illegal discharge, pollution and erosion. 19 Waste handling structures, piping pumps, reels, etc., should be inspected on a regular basis to prevent breakdowns, Teaks and spills. A regular maintenance checklist should be kept on site. 20 Animal waste can be used in a rotation that includes vegetables and other crops for direct human consumption. However, if animal waste is used on crops for direct human consumption it should only be applied pre -plant with no further applications animal waste during the crop season. 21 Highly visible markers shall be installed to mark the top and bottom elevations of the temporary storage (pumping volume) of all waste treatment lagoons. Pumping shall be managed to maintain the liquid level between the markers. A marker will be required to mark the maximum storage volume for waste storage ponds. 22 Waste shall be tested within 60 days of utilization and soil shall be tested at least annually at crop sites where waste products are applied. Nitrogen shall be the rate -determining element. Zinc and copper levels in the soil shall be monitored and alternative crop sites shall be used when these metal approach excessive levels. pH shall be adjusted for optimum crop production and maintained. Soil and waste analysis records shall be kept for five years. Poultry dry waste application records shall be maintained for three (3) years. Waste application records for all other waste shall be maintained for five (5) years. 23 Dead animals will be disposed of in a manner that meets North Carolina regulations. Page 7 Date: 9_ /S -O Date: Kraig A. Westerbeek WASTE UTILIZATION PLAN WASTE UTILIZATION PLAN AGREEMENT Name of Farm: Terrallova Farm Owner / Manager Agreement I (we) understand and will follow and implement the specifications and the operation and maintenance procedures established in the approved animal waste utilization plan for the farm named above. I (we) know that any expansion to the existing design capacity of the waste treatment and storage system or construction of new facilities will require a new certification to be submitted to the Division of Environment Management (DEM) before the new animals are stocked. I (we) also understand that there must be no discharge of animal waste from this system to surface waters of the state from a storm event less severe than the 25-year, 24-hour storm. The approved plan will be filed on -site at the farm office and at the office of the local Soil and Water Conservation District and will be available for review by DEM upon request. Name of Facility Owner: Willie Beard (Please print) Signature: ki dies .c) Name of Manager (If different from owner): Signature: Name of Technical Specialist: (Please print) Affiliation: Murphy Family Farms Address (Agency): P.O. Box 759 Rose H'i,NC2: 58 Signature: Date: -IOA Page 8 Go gle Maps 1194 Rosindale Rd - e'wc1 vc(. Imagery ©2019 Google, Map data ©2019 Google 200 ft EMERGENCY ACTION PLAfsj PHONE NUMBERS DW EMERGENCY MANAGEMENT SYSTEM 4I SWCD 910-862-693611 NRCS 910-8622-6936 This plan will be your plan w on are implemented in the event that site. You should leaking, overflowing,in off from ot wait until wastereach surfaceg or leave your Property toreach waters You should make ever Y o consider that happen. This y effort to ensure you have a problem.• happe lan should be osted that this does ion for all em in an accessible not_ are some action 1° ees at the facilit ssible items you should take. The following 1. Stop the release of wastes. situation, this may or ma situ to some y not be possible.Dependingon Suggested problems are listed below. A. Lagoon overflow - possible solutions are: a. Add soil to berm to Addwastes btincrease elevation of b.- Pumpop was flows fields at an acceptable dam. Call a the lagoon immediately. d. pumping contractor. Make sure no surface water is entering lagoon. g on. B: Runoff from waste application field -actions include: a. Immediately stop waste a b. Create a temporary dzvppl2cation. c. Incorporate wastetoersion to contain waste. d. Evaluate and eliminate educe runoff. caused the runoff, reason(s) that e. Evaluate the application rates for the fie where runoff occurred. Ids C: Leakage from the waste pipes and sprinkle - include: sprinklers -action a. Stop recycle pump. b. Stop irrigation pump. c. Close valves to eliminate further dischar e. 5 2. air all leaks prior to restarting pumps. d. Re p D; Leakage from flush systems, houses, solid separators -action include: a. Stop recycle pumpump. b. Stop irrigation hon occurs. d.c. Stop sure no sip or in the house, flush systems, p all flows um s. solid separators• rior to restarting pump e. Repair all leaks P E; Leakage or sidewalof lagoon. often this is seepage as opposedl base flowing leaks - possible action: to catch all seepage, p a. Dig a small well or ditch and pump back to put in a submersible pum trap animals an lagoon. b burrowing animals, If holes are caused byfill holes and compact or remove with a clay type soil.evaluate the condition o rof essiandllagoon soon as f c. Havea professional walls bottom as theheside w possible. Assess the extent of damages. a each any surface waters? b. D. the waste r how much was released and for b. Approximately injury, duration' e noted, such as employee c. Any dam or property damage? killsDithe , spill leave the property? d. e. Does the spill have the potential to waters? f. Could a future rain surface waterse '• wells g• Arotable water ofhe property)? h. How much reached surface waters? the spill and note any obvious what fish reach surface event cause the spill to reach in danger (either on or off o riate agencies. 3: contact aPPr p call your DWQ Phone normal business hours, call y office; g19- a. During . Water Quality) aloffice; (Division of After hours, emergency 910-486-1541• hone call should include: lu e: yourf name, 42. Your P number, name, facility, telephone the incident from item 2 above, the exact location of the facility, the location or direction of movement of the spill, weather and wind conditions. The corrective treasures that have been under taken, and the seriousness of the situation. b. If spill leaves property or enters surface waters, call local EMS Phone number •911-. c. Instruct EMS to contact local Health Department. d. Contact CES, phone number 910-862-4591, local SWCD office phone number 920-862-6936, and local NRCS office for advice/technical assistance phone number 910-862-6936_ 4: If none of the above works call 911 or the Sheriff's Department and explain your problem to them and ask that person to contact the proper agencies for you. 5: Contact the contractor of your choice to begin repair of problem to minimize off-site damage. a. Contractors Name: Did' J. -cICSo V)) b. Contractors Address: r-u-- ) Lox' 3 a 1 c. Contractors Phone: G,-d..,51,„"0001 J }F}, c. -9 /0— 69ci— 6: Contact the technical specialist who certified the lagoon (NRCS, Consulting Engineer, etc.) - a . Name: (5- Pi (iJ 9-rr e &) b. Phone: Cfi 6 — - L cl3 Lo 7: Implement procedures as advised by DWQ and technical assistance agencies to rectify the damage, repair the system, and reassess the waste management plan to keep problems with release of wastes from happening again. c audelnash/wordlempactplen.dc: sot 12.96 c as f.Y 0cc.AS'�v ..' ... •: � : .. ..,_ ;... • ii:1'A\v'C�}11.. :.. -,..x a�.c ,•"or.:nSWwvc.Aw.�Y,..;:a h:..xLSac.i?a...ntsa. E..�:.,ca.. aowawb�aar This plan will be implemented in the event that animal manure or lagoon effluent from your operation is leaking, overflowing, or running off the site: Step (1) Stop the release or flow of manure/effluent. Step (2) Assess the extent of the spill and note any obvious -damages. Step (3) Contact appropriate personnel and agencies. Murphy Family Farms: 800-311-9458 or 910-289-6439 (See Land & Nutrient Management phone list attached) Department of Environmental Management (DEM) Regional Office: cr/ - FG - )v1+1 DEM after hours emergency: 919-733-3942 Local Emergency Management System: / / 1 Local Natural Resource Conservation Service: 9 0 -" a Ce a- — (0 3 (Qa--- - 5 9 I Local Cooperative Extension Service: I Q .. Local Soil and Water Conservation District: 9) a- S'4 a-- 6 9 3 6 Local dirt-moving/heavy equipment companies: Name 1. , /Z., roc,- c. (C. so ?N1 2. r 11 ,t:e,11Lh 3. G—r c t Local contract pumping/urigation equipment companies: Name Phone # 1. E-1,75-(_c.)..ro f)=5r; SS-1-erg 9/a- a93 (200 3_ Joh»T•-‘nclr-)1 •.c71.0 -(5 ,&7 `0,5 Step (4) Implement procedures as advised by MFF, DEM, and technical assistance agencies to rectify the damage, repair the system, and reassess the nutrient management plan to prevent future problems. Phone # 9(0- 62,9' 9 o- 8"6 -393S q 0 -- -s (1-- VS Note 1: See MFF Environmental Emergency Procedures Flowchart attached Note 2: See pages 89-91 of the Certification Training Manual for more details. Flush Clutters • Accumulation of solids Lagoons ;and fits • Crusted Solids -Excessive Vegetative • Decoying vegetation (iromit Mortality Management Methods (check which method(s) are being. implemented) 'J Burial three feet beneath the surface of the ground within 24 hours after knowledge of the death. The burial must be at. least 300 feet from any flowing. _stream or public body of water. �Y Rendering at a rendering plant licensed under G.S. 106-163.7 ❑ Complete incineration In the case of dead poultry only, piacine in a disposal pit of a size and desi;n approved by the Department of Agriculture Any method which in the professional opinion of the State Veterinarian would make possible the salvage of part of a dead animal's value without endangering human or animal health. (Written approval of the State Veterinarian must be attached) J Insect Control Checklist for Animal Operations Source cnusc IIA11's lu Coulrol Llsecls Sitc Sl,ceiGc l'racliccs Liquid Systems —" C?'Flush system is designed and operated sufficiently to remove accumulated solids from Antlers as designed. £Y. Remove bridging of accumulated solids at discharge CLACiaintain lagoons, settling basins and piis wlicrc pest breeding is apparent to minimize the crusting of solids to a depth of no more than 6 - 8 inches over more than 30% of surface. 11..-- itintain vegetative control along banks of lagoons and other impoundments to Prevent accumulation of decaying vegetative matter along water's edge on impoundment's perinieler. Swine Farm Waste Management Odor Control Checklist Source Cause BMPs to Minimize Odor Site Specific Practices Farmstead • Swine production Olegetative or wooded buffers t —1 ecommended best management practices Good judgment and common sense Animal body surfaces • Dirty manure -covered O Dry floors animals Floor surfaces • Wet manure -covered floors CTotted floors O Waterers located over slotted floors Z.-Feeders at high end of solid floors 0--Serape manure buildup from floors O Underfloor ventilation for drying Manure collection • Urine EP—Frequent manure removal by flush, pit recharge, pits • Partial microbial or scrape decomposition O Underfloor ventilation Ventilation exhaust • Volatile gases fans • Dust 0--Fan maintenance O Efficient air movement Indoor surfaces • Dust —Washdown between groups of animals O Feed additives C7 Feeder covers eed delivery downspout extenders to feeder covers Flush tanks • Agitation of recycled lagoon Cl Flush tank covers liquid while tanks are filling CYExtend fill lines to near bottom of tanks with anti -siphon vents Swine Farm Waste Management Odor Control Checklist Source Flush alleys Pit recharge points "(4 Lift stations 44 Cause • Agitation during wastewater conveyance • Agitation of recycled lagoon liquid while pits are filling BMPs to Minimize Odor O Underfloor flush with underfloor ventilation Site Specific Practices O Extend recharge lines to near bottom of pits with anti -siphon vents Outside drain collection or 416.junction boxes End of drainpipes at lagoon Lagoon surfaces • Agitation during sump tank filling and drawdown O Sump tank covers • Agitation during wastewater conveyance El Box covers • Agitation during wastewater conveyance O Extend discharge point of pipes underneath lagoon liquid level • Volatile gas emissions • Biological mixing • Agitation Irrigation sprinkler nozzles • High pressure agitation • Wind drift Doper lagoon liquid capacity C Correct lagoon startup procedures 1p2ilinimum surface area -to -volume ratio CLlvfinimum agitation when pumping O Mechanical aeration O Proven biological additives CL-t r`igate on dry days with little or no wind LIinimum recommended operating pressure Ct1-I tnnp intake near lagoon liquid surface O Pump from second -stage lagoon Swine Farm Waste Management Odor Control Checklist Source Cause Storage tank or basin surface �'� Settling basin surface • Partial microbial decomposition • Mixing while filling • Agitation when emptying BMPs to Minimize Odor Site Specific Practices ❑ Bottom or midlevel loading ❑ Tank covers ❑ Basin surface mats of solids ❑ Proven biological additives or oxidants • Partial microbial decomposition • Mixing while filling • Agitation when emptying Manure, slurry, or sludge spreader outlets Uncovered manure, slurry, or sludge on field surfaces Dead animals ❑ Extend drainpipe outlets underneath liquid level ❑ Remove settled solids regularly • Agitation when spreading • Volatile gas emissions El Soil injection of slurry/sludges ❑ Wash residual manure from spreader after use O Proven biological additives or oxidants • Volatile gas emissions while drying ❑ Soil injection of slurry/sludges O Soil incorporation within 48 hours O Spread in thin uniform layers for rapid drying O Proven biological additives or oxidants • Carcass decomposition IYY Proper disposition of carcasses Dead animal disposal pits • Carcass decomposition Incinerators N ( �' • Standing water • around facilities O Complete covering of carcasses in burial pits O Proper location/construction of disposal pits Incomplete combustion Improper drainage El Secondary stack burners • Microbial decomposition of organic matter fa --Grade and landscape such that water drains away from facilities. Swine Farm Waste Management Odor Control Checklist Source Cause BMPs to Minimize Odor Manure tracked onto • Poorly maintained access public roads from roads farm access { arm access road maintenance Site Specific Practices Additional Information: Available From: Swine Manure Management; .0200 Rule/BMP Packet Swine Production Farm Potential Odor Sources and Remedies; EBAE Fact Sheet Swine Production Facility Manure Management: Pit Recharge —Lagoon Treatment; EBAE 128-88 Swine Production Facility Manure Management: Underfloor Flush —Lagoon Treatment; EBAE 129-88 Lagoon Design and Management for Livestock Manure Treatment and Storage; EBAE 103-83 Calibration of Manure and Wastewater Application Equipment; EBAE Fact Sheet Controlling Odors from Swine Buildings; PII-1-33 Environmental Assurance Program; NPPC Manual Options for Managing Odor; a report from the Swine Odor Task Force Nuisance Concerns in Animal Manure Management: Odors and Flies; PRO107, 1995 Conference Proceedings NCSU, County Extension Center NCSU—BAG NCSU—BAE NCSU—BAE NCSU—BAE NCSU—BAE NCSU—Swine Extension N.C. Pork Producers Assoc. NCSU Agricultural Communications Florida Cooperative Extension e (rr O v 9-132 Mortality Management Methods indicate which method(s) will be implemented. When selecting multiple methods indicate a primary versus secondary option. Methods other than those listed must be approved by the State Veterinarian. Primary Secondary Routine Mortality El El El El -71 as 00 El Version —November 26, 2018 Burial three feet beneath the surface of the ground within 24 hours of knowledge of animal death. The burial must be at least 300 feet from any flowing stream or public body of water (G.S.106-403). The bottom of the burial pit should be at least one foot above the seasonal high water table. Attach burial location map and plan. Landfill at municipal solid waste facility permitted by NC DEQ under GS 15A NCAC 13B .0200. Rendering at a rendering plant licensed under G.S. 106-168.7. Complete incineration according to 02 NCAC 52C .0102. A composting system approved and permitted by the NC Department of Agriculture & Con- sumer Services Veterinary Division (attach copy of permit). If compost is distributed off -farm, additional requirements must be met and a permit is required from NC DEQ. In the case of dead poultry only, placing in a disposal pit of a size and design approved by the NC Department of Agriculture & Consumer Services (G.S. 106-549.70). Any method which, in the professional opinion of the State Veterinarian, would make possible the salvage of part of a dead animal's value without endangering human or animal health. (Written approval by the State Veterinarian must be attached). Mass Mortality Plan Mass mortality plans are required for farms covered by an NPDES permit. These plans are also recommended for all animal operations. This plan outlines farm -specific mortality man- agement methods to be used for mass mortality. The NCDA&CS Veterinary Division sup- ports a variety of emergency mortality disposal options; contact the Division for guidance. • A catastrophic mortality disposal plan is part of the facility's CAWMP and is activated when numbers of dead animals exceed normal mortality rates as specified by the State Veterinarian. • Burial must be done in accordance with NC General Statutes and NCDA&CS Veterinary Division regulations and guidance. • Mass burial sites are subject to additional permit conditions (refer to facility's animal waste management system permit). • In the event of imminent threat of a disease emergency, the State Veterinarian may enact additional temporary procedures or measures for disposal according to G.S. 106-399.4. Signature of Farm Owner/Manager 60/V Signat re of Technical Specialist Date c icleci Date ^ ,�:�� | Te \� u�--. �V�� /erator:Bi||y Mc8avock County: BLADEN Date: 07/28/92 - Distance to nearest residence (other than ownei): I200.0 feet 1 STEADY STATE LIVE WEIGHT 0 sows (farrow to finish) x 1417 |bs. = 0 1ns O sOws (farrow to feeder) x 522 !bs. = 0 |bs 2448 head (finishing only) x 135 lbs. = 330480 ibs 0 sews (farrow to wean) x 433 /bs. = 0 /bs 0 nead (wean to feeder) x 30 lbs. = 0 ibs TOTAL STEADY STATE LIVE WEIGHT (SSLN) = 330480 !'bs 2. NINIMUM REQUIRED TREATMENT VOLUME OF LAGOON. Volume = 330480 !bs. SSLW x Trearment Vo|ume(CF)/|o, SSLN Treatment Volume(CF)//b. SSLN= 1 CF//b. SSLW Ve.ume = 330480 cubic feet 3. STORAGE VOLUmE FOR SLUDGE ACCUMULATION Volume = 0.0 cubic feet 4. TOTAL DESIGN VOLUME Inside top !endth 300.0 feet ; Inside top w/dtn 240.0 feet Top of dike at elevation 48.0 feet Freeboara 1.0 feet ; Side slopes 3.0 : 1 (inside lagoon) Total design lagoon liquid level at elevation 47.0 feet Bottom of lagoon elevation 38.0 feet Seasonal high water table elevation 41.0 feet Total design volume using prismoida! formula SS/END1 3.0 SS/END2 SS/SIDE1 S8/SIDE2 3.0 3.0 3.0 LENGTH 294.0 WIDTH 234.0 AREA OF TOP LENGTH * WIDTH = 294.0 234.0 68796.0 (AREA OF TOP) AREA OF BOTTOM LENGTH * WIDTH = 240.0 180.0 43200.0 (AREA OF BOTTOM) DEPTH 9.0 AREA OF MIDSECTION LENGTH * WIDTH * 4 267.0 207.0 221076.0 (AREA OF MIDSECTION * 4) CU. FT. = [AREA TOP + (4*AREA MIDSECTION) + AREA BOTTOM] * DEPTH/6 68796.0 221076.0 43200.0 1. VOLUME OF LAGOON AT TOTAL DESIGN LIQUID LEVEL = 499608 CO. F7. ^ 58. TEMPORARY STORAGE REQUIRED DRAINAGE AREA: Lagoon (top of dike) Length * Width = 300.0 240.0 � ' ,_w 72000.0 square feet Buildings (roof and lot water) Len8th * Width = 0.0 0.0 0.0 square feet TOTAL DA 72000.0 square feet Design temporary storage period to be 180 days. 5A. Volume of waste proouced Approximate daily production of manure in CF/L8 SSi-N 0.00136 Volume o ume = 330480 Lss. SSLW * CF of Waste/Lb./Day * 180 days Volume = 80705 cubic feet Volume of wash water This is the amount of fresh water useo for washing fioors or volume of fresh water used for a flush system. Flush systems that rccircu\at the lagoon water are accounted for in 5A. Vo|ume = Volume = 0.0 cubic feet 0.0 gallons/day * 180 days stora3e/(.48 gallons per CF 5C. Volume of rainfall in excess of evaporation Use period of time when rainfall exceeds evaporation by largest amount -� , 180 days excess rainfall = T.O'inches Vo|ume = 7.0 in * DA / 12 inches per foot r /%m Volume = 42000.0 cubic feet Volume of 25 year - 24 hour storm Volume = 7.0 inches / 12 inches per foot * DA Volume = 42000.0 cubic feet TOTAL REQUIRED TPMPORARY STORA8E 5A. 80705 cubic feet 5B. 0 cubic feet 5C. 42000 cubic feet 5D. 42000 cubic feet TOTAL 164705 cubic feet 6. SUMMARY Total required voiume 495185 cubic feet Total design volume avai |. cubic feet Min. req. treatment volume plus s/udSe accumunnon 330480 cubic f At elev. 44.5 feet ; Volume is 337331 cubic feet (end pumping) Total design volume less 25yr-24hr storm is 45760S cubic feet At elev. 46.3 feet ; Volume is 452223 cubic feet (start pumping Seasonaj high water table e!evat/on 41.0 feet 7. DESIGNED BY: �=� ~W '' ^� APPROVED BY: DATE: �_�3-q7_ DATE: NOTE: SEE ATTACHED WASTE UTILIZATION PLAN Jperato�� E County: BLADEN Date: 09/16/94 Distinc'e to n/^rest residence (other than owner) : 0.0 feet I. AVERAGE LIVE WEIGHT (ALW) 0 sows (farrow to finish) x 1417 lbs = 0 lb 0 sows (farrow to feeder) x 522 lbs. s 1224 head (finishing only) : 135 lbs. = 0 lbs 0 sows (farrow to wean) x 433 lbs^ = 165240 lbs 0 head (wean to feeder).x 30 lbs,. = 0 lbs Describe other : = 0 lbs .................................... 0 ____ _________________________ ------- Total Average Live Weight = 165240 lbs Z. MINIMUM REQUIRED TREATMENT VOLUME OF LAGOON Volume = 165240 lbs. ALW x Treatment Volume(CF)/lb ALW Treatment Volume(CF)/lb. ALW = 1 CF/lb ^LW Volume = 165240 cubic feet ^ � 1. STORAGE VOLUME FOR SLUDGE ACCUMULATION Volume = 0.0 cubic feet 4. TOTAL DESIGNED VOLUME APR 012019 Inside top length (feet) ----- ..................... 365 0 --- Inside top width (feet) ------- ^ ------------ 128.0 ---- Top of dike elevation (feet) --- ^ ---------- 51.3 Bottom of lagoon elevation (feet)------------ 41^3 Freeboard (feet)--------------__ ^ ------------- 1 0 Side slopes (inside lagoon) ------------------ 3^0 : 1 Total design volume using prismoidal formula SS/END1 SS/END2 SS/SIDE1 SS/SIDE2 LENGTH WIDTH DEPTH 3.0 NO 3.0 3.0 359.0 122.0 9.0 AREA OF TOP LENGTH * WIDTH = 359.0 122.0 AREA OF BOTTOM LENGTH * WIDTH = 305.0 68.0 AREA OF MIDSECTION LENGTH * WIDTH * 4 332.0 95.0 / 43798 (AREA OF TOP) 20740 (AREA OF BOTTOM) 126160 (AREA OF MIDSECTION * 4) CU. FT. = [AREA TOP + (4*AREA MIDSECTION) + AREA BOTTOM] 43798.0 126160.0 20740.0 * DEPTH/6 1.5 Total Designed Volume Avai1able = 286047 CU. F7' TEMPORARY STORAGE REQUIRED DRAINAGE AREA: Lagoon (top of dike) Length * Width = 365.0 128.0 46720.0 square feet Buildings (roof and lot water) 0.0 square feet Describe this area. TOTAL DA 46720.0 square feet Design temporary storage period to be 180 days. Volume of waste produced Feces & urine production in gal./day per 135 lb. ALW 1.37 Volume = 165240 lbs. ALW/135 lbs. ALW * 1.37 gal/day 180 days Volume = 301838 gals. or 40352.7 cubic feet Volume of wash water This is the amount of fresh water used for washing floors or volume of fresh water used for a flush system. Flush systems that recirculate the lagoon water are accounted for in 5A. Volume = 0.0 gallons/day * 180 days storage/7.48 gallons per CF Volume = 0.0 cubic feet' Volume of rainfall in excess of evaporation Use period of time when rainfall exceeds evaporation by largest amount. 180 days excess rainfall Volume = = 7'0 inches ��. 7.0 in * DA / 12 inches per foot := 410 Volume = 27253.3 cubic feet 5D. Volume of 25 year - 24 hour storm Volume = 7.3 inches / 12 inches per foot * DA Volume - 28421.3 cubic feet TOTAL REQUIRED TEMPORARY STORAGE 5A. 40353 cubic feet SB • 0 cubic feet 5C. 27253 cubic feet 5D. 28421 cubic feet TOTAL. 96027 cubic feet . SUMMARY Temporary storage peri. od =•-•-'---------- -__:____::_-__ . 180 days Rainfall in excess of evaporation============__'::. 7.0 inches 25 year - 24 hour rainfall ----•--•--__ _•_ = __=:__ ___''> -- - inches Fr-eehoard= _:__.•=====:= _:_-___-_:--_---•-_._:__= :_:_•_____-:•• ... Side slopes.._.. - =--•- 1.0 feet inside top length----- --=---•--•--===___--•---. 365.0 feet. inside top width=====__-_ _:___:__=_________;___ _'_ ` 128. 0 feet Top of dike e.leverti on==____ _____ =_.-.• _====•:> 51.3 feet Bottom of lagoon elevation--------- -------- :.• 41.3 feet Total required vo.l ume==-==========:__•=•=_ _:___=:-:'> 26:1267 cu. ft. Actual design volume--------- ___._.-_._________-•. 286047 cu. ft. Seasonal high water•tab l e elevation (SHWT) === 45.8 feet Stop pumping el ev. =_-=-_ �--------•--•------- ____ _ __-•----':> 47.5 •feet Must be > or = to the SHWT el ev. __--•- .__-=_> 45.8 feet Must be ::> or = to min. req. treatment el . _:• 47.3 feet Required minimum treatment volume=======___-_ > 165240 cu. ft. Volume at stop pumping elevation=====____ __== :> 174462 cu. f t . Start pumping elev.- -----.__.___.----__-•-. 49.5 feet. * Must be at bottom of freeboard &. 25 yr. . -rainfall. Actual .volume less 25 yr.- 24 hr. rainfall==> 257626 cu. ft. Vol ume at start pumping elevation=======:__= == => 2_ , _.�19�6 cu. ft. Required vol ume to be pumped =•____-----.-.-_=_ _=:> 67606 cu. f t . Actual volume planned to be pumped--•-----___--.. 77464 cu. ft. Min. thickness of soil liner when required== > 1.5 feet. - DESIGNED BY: DATE APPROVED BY: DATE: p514/14 NOTE: SEE ATTACHED WASTE UTILIZATION PLAN COMMENT : fir rt OPERATION AND MAINTENANCE PLAN SHEET 1 OF 2 This lagoon is designed for waste treatment (permanent storage) and 180 days of temporary storage. The time required for the planned fluid level (permanent and temporary storage) to be reached may vary due to site conditions, weather, flushing operations, and the amount of fresh water added to the system. The designed temporary storage consists of 180 days storage for: (1) waste from animals and (2) excess rainfall after evaporation. Also included is storage for the 25 year - 24 hour storm for the location. The volume of waste generated from a given number of animals will be fairly constant throughout the year and from year to year, but excess rainfall will vary from year to year. The 25 year rainfall will not be a factor to consider in an annual pumping cycle, but this storage volume must always be available. A maximum elevation is determined in each design to begin pumping and this is usually the outlet invert of pipe(s) from building(s). If the outlet pipe is not installed at the elevation to begin pumping, a permanent marker must be installed at this elevation to indicate when pumping should begin. An elevation must be established to stop pumping to maintain lagoon treatment depth. Pumping can be started or stopped at any time between these two elevations for operating convenience as site conditions permit, such as weather, soils, crop, and equipment in order to apply waste without runoff or leaching. Land application of method of disposal. center pivot, guns, taken when applying waste water is recognized as an acceptable Methods of application include solid set, and traveling gun irrigation. Care should be waste to prevent damage to crops. The following items are to be carried out: 1. It is strongly recommended that the treatment lagoon be pre - charged to 1/2 its capacity to prevent excessive odors during start-up. Pre -charging reduces the concentration of the initial waste entering the lagoon thereby reducing odors. Solids should be covered with effluent at all times. When precharging is complete, flush buildings with recycled lagoon liquid. Fresh water should not be used for flushing after initial filling. 2. The attached waste utilization plan shall be followed. This plan recommends sampling and testing of waste (see attachment) before land application. 3. Begin temporary storage pump -out of the lagoon when fluid level reaches the elevation 98.0 as marked by permanent marker. Stop pump - out when the fluid level reaches elevation 95.6 . This temporary storage, less 25 yr- 24 hr storm, contains 172100 cubic feet or 1287307 gallons. SHEET 2 OF 2 4. The recommended maximum amount to apply per irrigation is one (1) inch and the recommended maximum application rate is 0.3 inch per hour. Refer to the waste utilization plan for further details. 5. Keep vegetation on the embankment and areas adjacent to the lagoon mowed annually. Vegetation should be fertilized as needed to maintain a vigorous stand. 6. Repair any eroded areas or areas damaged by rodents and establish in vegetation. 7. All surface runoff is to be diverted from the lagoon to stable outlets. 8. Keep a minimum of 25 feet of grass vegetated buffer around waste utilization fields adjacent to perennial streams. Waste will not be applied in open ditches. Do not pump within 200 feet of a residence or within 100 feet of a well. Waste shall be applied in a manner not to reach other property and public right-of-ways. 9. The Clean Water Act of 1977 prohibits the discharge of pollutants into waters of the United States. The Department of Environment, Health, and Natural Resources, Division of Environ- mental Management, has the responsibility for enforcing this law.