HomeMy WebLinkAboutNC0021601_NOV-2024-PC-0004_20240104
January 04, 2024
Jim Fatland
Town of Tryon
301 N Trade St
Tryon, NC 28782
SUBJECT: NOTICE OF VIOLATION
Tracking Number: NOV-2024-PC-0004
Permit No. NC0021601
Tryon WWTP
Polk County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Tryon WWTP on December 19,
2023. This inspection was conducted to verify that the facility is operating in compliance with the conditions and
limitations specified in NPDES WW Permit No. NC0021601. A summary of the findings and comments noted
during the inspection are provided in the enclosed copy of the inspection report.
The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Asheville
Regional Office. The following violation(s) were noted during the inspection:
Inspection Area Description of Violation _________________________________________________________________________________________________________________________________________________________________________
Effluent Sampling Currently, effluent sampling is time-based. Per permit requirements (see Part II, Section A)
sampling should be flow-proportional.
_________________________________________________________________________________________________________________________________________________________________________
DocuSign Envelope ID: 068AB960-2088-4A28-956F-BFF9CB0B63D2
Remedial actions should have already been taken to correct this problem and prevent further occurrences in the
future. The Division of Water Resources may pursue enforcement action for this and any additional violations of
State law.
To prevent further action, please respond in writing to this office within 30 days upon your receipt of this Notice
of Violation regarding your plans or measures to be taken to address the indicated violations and other identified
issues, if applicable.
If you should have any questions, please do not hesitate to contact Melanie Kemp with the Water Quality
Regional Operations Section in the Asheville Regional Office at 828-296-4500 or melanie.kemp@deq.nc.gov.
Sincerely,
Daniel J. Boss, Acting Regional Supervisor
Water Quality Regional Operations Section
Asheville Regional Office
Division of Water Resources, NCDEQ
ATTACHMENT: Compliance Evaluation Inspection Report
Ec: LF, Brad McKinney (ORC), Deborah Bradley (BORC)
DocuSign Envelope ID: 068AB960-2088-4A28-956F-BFF9CB0B63D2
EPA
United States Environmental Protection Agency
Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NC0021601 23/12/19 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
3 N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Tryon WWTP
1526 E Howard St
Tryon NC 28782
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
10:00AM 23/12/19 20/08/01
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Bradley Lynn McKinney/ORC//
Other Facility Data
12:00PM 23/12/19 24/12/31
Name, Address of Responsible Official/Title/Phone and Fax Number
Deborah Bradley, /ORC/828-894-2048/Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self-Monitoring Program Facility Site Review Effluent/Receiving Waters Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Melanie Kemp DWR/ARO WQ/ - - /
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
DocuSign Envelope ID: 068AB960-2088-4A28-956F-BFF9CB0B63D2
NPDES yr/mo/day
23/12/19
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Melanie Kemp, with the Asheville Regional Office, conducted a Compliance Evaluation Inspection of
the Town of Tryon’ s WWTP on December 19, 2023, to ensure the facility is operating in compliance
with NDPES permit NC0021601. Brad McKinney (ORC) and Deborah Bradley (BORC) were present
and assisted with the inspection.
Sampling: Effluent composite samples are currently time-based (collecting 100 mL/hour). Per permit
requirements (see Part II, Section A), effluent composite samples should be flow-proportional. A
notice of violation (NOV) is being issued for failure to comply with permit requirements.
Mechanical Bar Screen: The bar screen is still operational, however, the facility reported that based
on the age and parts availability of the equipment it should be replaced in the next couple of years.
Secondary Clarifiers: The weir teeth on Clarifier # 1 are still severely rusted. This does not appear to
have adversely affected effluent values, but this has been a noted deficiency since 2017. Funds
required for clarifier upgrades should be included in the next town budget.
During the inspection, a meeting was conducted with Tryon Finishing Corp to discuss copper limits
and flow rates. Deborah Bradley (WWTP BORC), Melanie Kemp (ARO) and Naiden Kremenliev
(President of Tryon Finishing Corp) were present during the meeting. The industrial user (IU) is
discussing the addition of industrial hemp fiber processing in the coming years. The facility is
interested in adjusting their permitted flow and copper limits. The current Headworks Analysis
submitted by the town indicates that the WWTP has additional copper allocation that could be
provided to the IU, should they want to change their permit.
NC0021601 17 (Cont.)
Page#2
DocuSign Envelope ID: 068AB960-2088-4A28-956F-BFF9CB0B63D2
Permit:NC0021601
Inspection Date:12/19/2023
Owner - Facility:
Inspection Type:
Tryon WWTP
Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Flow Measurement - Influent Yes No NA NE
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Influent flow was reading at 0.224 MGD during the inspection. The flow meter was last
calibrated on 12/8/23.
Comment:
Influent Sampling Yes No NA NE
# Is composite sampling flow proportional?
Is sample collected above side streams?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is sampling performed according to the permit?
Currently, sampling is time-based (100 mL/hour).Comment:
Bar Screens Yes No NA NE
Type of bar screen
Page#3
DocuSign Envelope ID: 068AB960-2088-4A28-956F-BFF9CB0B63D2
Permit:NC0021601
Inspection Date:12/19/2023
Owner - Facility:
Inspection Type:
Tryon WWTP
Compliance Evaluation
Bar Screens Yes No NA NE
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Facility reports that the bar screen is dated and back-up parts are difficult to source.
The bar screen should be upgraded in the coming years.
Comment:
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth)
No observable sludge blanket present in Clarifier 2 during inspection. Weir teeth are
eroded and need to be replaced on Clarifier 1.
Comment:
Disinfection-Gas Yes No NA NE
Are cylinders secured adequately?
Are cylinders protected from direct sunlight?
Is there adequate reserve supply of disinfectant?
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de-chlorination?
Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No.
7782-50-5)?
If yes, then is there a Risk Management Plan on site?
Page#4
DocuSign Envelope ID: 068AB960-2088-4A28-956F-BFF9CB0B63D2
Permit:NC0021601
Inspection Date:12/19/2023
Owner - Facility:
Inspection Type:
Tryon WWTP
Compliance Evaluation
Disinfection-Gas Yes No NA NE
If yes, then what is the EPA twelve digit ID Number? (1000-____-____)
If yes, then when was the RMP last updated?
Manual feed system for chlorine gas. Two cylinders were in use and four stored during
the inspection. The feed system is inspected and maintained yearly by an outside
contractor.
Comment:
De-chlorination Yes No NA NE
Type of system ?Liquid
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de-chlorination substance stored away from chlorine containers?
Are the tablets the proper size and type?
Liquid chlorine is dripped into contact chamber.Comment:
Are tablet de-chlorinators operational?
Number of tubes in use?
Comment:
Flow Measurement - Effluent Yes No NA NE
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Effluent flow meter calibrated annually (last on 12/8/23).Comment:
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Currently, sampling is time-based (100 mL/hour). Per the permit, effluent composite
sampling should be flow-proportional.
Comment:
Page#5
DocuSign Envelope ID: 068AB960-2088-4A28-956F-BFF9CB0B63D2
Permit:NC0021601
Inspection Date:12/19/2023
Owner - Facility:
Inspection Type:
Tryon WWTP
Compliance Evaluation
Effluent Sampling Yes No NA NE
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Page#6