Loading...
HomeMy WebLinkAboutWM0100570_Monitoring Well Construction Application_20240212AECOM 6000 Fairview Raod, Suite 200 Charlotte, NC 28210 T: 704.522.0330 aecom.com February 12, 2024 North Carolina Department of Environmental Quality Aquifer Protection Section Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Attn: Mr. Landon Davidson Re: Monitoring Well Permit Application Swannanoa Cleaners DSCA Site No. DC110003 916 Tunnel Road, Asheville, Buncombe County, North Carolina Dear Mr. Davidson: AECOM Technical Services of North Carolina, Inc. on behalf of the NCDEQ – DSCA Program, has prepared the attached permit application for the construction of one monitoring well in Asheville, Buncombe County, North Carolina. This application is being submitted in accordance with 15A NCAC 2C.0105. Proposed activities include installation of one monitoring well on an off-site property (936 Tunnel Road). Upon approval, please forward a copy of the monitoring well construction permit to aaron.council@aecom.com. If you have any questions or require additional information, please do not hesitate to call Rob MacWilliams at 704.499.4839 or Aaron Council at 864.351.9517. Sincerely, AECOM TECHNICAL SERVICES OF NORTH CAROLINA, INC. Aaron S. Council Robert H. MacWilliams, PG Senior Project Manager Program Manager Enclosures FOR OFFICE USE ONLY  PERMIT NO.   ISSUED DATE   NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1.Date: 02/12/2024 2.County: Buncombe 3.What type of well are you applying for? (monitoring or recovery): Monitoring 4.Applicant: Swannanoa Laundry, Inc. (Petitioner for DSCA Site DC110003) Telephone: 919-707-8359 Applicant’s Mailing Address:DSCA Program (Attn: Scott Stupak), 1646 Mail Service Center, Raleigh, NC 27699-1646 Applicant’s Email Address (if available): scott.stupak@deq.nc.gov 5.Contact Person (if different than Applicant): Aaron Council Telephone: (864) 351-9517 Contact Person’s Mailing Address: 10 Patewood Drive, Building 6, Suite 500, Greenville, SC 27615 Contact Person’s Email Address (if available): aaron.council@aecom.com 6.Property Owner (if different than Applicant): Casa Terra Properties, LLC (Majorie Varn) Telephone: 828-713-2130 Property Owner’s Mailing Address: 1546 Pearson Falls Road, Saluda, NC 28773 Property Owner’s Email Address (if available): samamongtrees@gmail.com 7.Property Physical Address (Including PIN Number) 936 Tunnel Road, Asheville, NC 28805 / PIN 965897168100000 City Asheville County Buncombe Zip Code 28805 8.Reason for Well(s): Groundwater contamination (ex: non-discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed:DSCA site DC110003 (ex: non-discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). DC110003 / Swannanoa Cleaners (DSCA Site) 11.Type of contaminants being monitored or recovered:chlorinated solvents (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? 3 Existing Monitoring or Recovery Well Construction Permit No(s).: None 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet):~100 feet 14.Are there any water supply wells located less than 500 feet from the proposed well(s)?No known wells If yes, give distance(s): 15.Well Contractor: M&W Drilling, LLC Certification No.: 2332-A Well Contractor Address: 4158 N NC 16 Business Highway, Denver, NC 28037-6206 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a.Borehole and well diameter e.Type of casing material and thickness b.Estimated well depth f.Grout horizons c.Screen intervals g.Well head completion details d.Sand/gravel pack intervals WM0100570 02/13/2024 PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2.Number of wells to be constructed in unconsolidated material: 1 3.Number of wells to be constructed in bedrock: 0 4.Total Number of wells to be constructed: 1 (add answers from 2 and 3) 5.How will the well(s) be secured?Bolted manhole cover and padlock 6.Estimated beginning construction date: 2/21/2024 7.Estimated construction completion date: 2/21/2024 ADDITIONAL INFORMATION 1.As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a.All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b.All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c.The proposed well or well system. d.Any test borings within 500 feet of proposed well or well system. e.All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant assumes total responsibility for ensuring that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. on behalf of DSCA Petitioner for DSCA Site DC110003 Project Manager_ Signature of Applicant or *Agent Title of Applicant or *Agent Aaron Council, on behalf of DSCA Petitioner for DSCA Site DC110003* If signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the Applicant, the property owner hereby consents to allow the Applicant to construct well(s) as outlined in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to ensure that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. See attached access agreement See attached access agreement Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources’ Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 GW-22M/R (Rev. 5-26-2022) GW 22MR (6/11) HENDERSON BUNCOMBE HENDERSON AREA SHOWN WITHIN BUNCOMBE COUNTY Site Location Map Former Swannanoa Cleaners 916 Tunnel Road Asheville, NC DSCA Site DC110003 NOTE: Source: City of Asheville Approximate site boundary AECOM TECHNICAL SERVICES OF NORTH CAROLINA, INC 6000 FAIRVIEW ROAD, SUITE 200 CHARLOTTE, NC 28210 TEL: (704) 522-0330 FAX: (704) 522-0063 DR AWN B Y: CH E C K E D B Y: PR O J E C T N O . : E D - 0 9 / 1 4 / 2 0 2 2 Figure 1 000,10500 Feet SITE 11 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 42 43 40 41 LEGEND Former Swannanoa Cleaners (DC110003) Area of PCE 2L Standard Exceedance Proposed Monitoring Well Location Parcel Line Red highlighted text indicates concentrations above 2L Standards. PCE - Tetrachloroethylene TCE - Trichloroethylene cis-1,2-DCE - cis-1,2-Dichloroethylene Analytical results do not exceed calculated vapor intrusion risk for residential or non-residential exposure – DSCA Indoor Air Risk Calculator. Analytical results do not exceed calculated vapor intrusion risk for non-residential exposure but do exceed for residential exposure – DSCA Indoor Air Risk Calculator. Analytical results exceed calculated vapor intrusion risk for residential and non-resi- dential exposure – DSCA Indoor Air Risk Calculator. MW-5 Potentiometric Surface Contour (ft) Inferred Groundwater Flow APPROX. SCALE, ft. 0 Figure 2SHEET: DR A W N B Y : CH E C K E D B Y : PR O J E C T N O . : AE C O M T E C H N I C A L S E R V I C E S O F N O R T H C A R O L I N A , I N C 60 0 0 F A I R V I E W R O A D , S U I T E 2 0 0 CH A R L O T T E , N C 2 8 2 1 0 TE L : ( 7 0 4 ) 5 2 2 - 0 3 3 0 FA X : ( 7 0 4 ) 5 2 2 - 0 0 6 3 120 JC W - 1 2 / 1 1 / 2 0 2 3 Pr o p o s e d G r o u n d w a t e r M o n i t o r i n g We l l L o c a t i o n s Fo r m e r S w a n n a n o a C l e a n e r s 9 1 6 T u n n e l R o a d , A s h e v i l l e , N C DS C A S i t e D C 1 1 0 0 0 3 60 6 9 5 2 8 5 AS C - 1 2 / 1 1 / 2 0 2 3 Monitoring Well Location BDL MW-2 (12/2/2022) MW-3 (12/2/2022) PCE - 7.5 µg/L TCE - 11.9 µg/L Cis-1,2-DCE - 496 µg/L BDL MW-1 (12/2/2022) MW-4 60.80 ft 60.90 ft TUNN E L R O A D L Y N N S T O N E C O U R T BEVE R L Y R O A D TYPE II GROUNDWATER MONITORING WELL INSTALLATION DETAIL Project Name:Swannanoa Cleaners Drilling Co:M&W Drilling, LLC Well Number: Location:Asheville, North Carolina Driller:Chris Schappell Job Number: Client:NCDEQ - DSCA Program Drilling Method:Hollow-Stem Auger Date Completed: Geologist:Griffin Collins Static Water Level: b.TOC Survey Datum: Manhole with Bolt Down Lid Top Of Casing Elevation ft 0.00 ft With Lockable Cap Stickup Grass, Asphalt/Concrete Land Surface Elevation ft Concrete Surface Pad Surface Casing From ft to 35.0 ft (2 ft x 2 ft x 6 in) Casing Type: SCH-40 PVC COMMENTS Inside Diameter: 2 Diameter of Borehole (nominal) 6 in Bentonite/Cement Grout From ft to 31.0 ft Note:Bottom of Boring (estimated)Depth 50 ft Drawing Not to Scale Depth 50.0 ft All Depths are Referenced to Ground Surface Total Depth of Well, b. Top of Casing Depth 50 ft Bottom of Well ft in Screen Length: 10 ft Filter Sand for Screen Sand Type: Medium 2 From 33.0 ft to 50.0 Screen Slot Size: 0.010-in ID 33.0 ft Top of Screen Depth 35.0 ft Screen Type: SCH-40 PVC to Bentonite Pellet Seal From 31.0 ft TBD 0.0 0.5 TBD MW-4 60723135 TBD TBD TBD MW Construction Details.xlsx