Loading...
HomeMy WebLinkAboutSWA000230_Response To Comments_20240212 MORRIS & RITCHIE ASSOCIATES OF NC, PC • kT1 ■ —JAB AN AFFILIATE OF MORRIS& RITCHIE ASSOCIATES, INC.WHICH PROVIDES ENGINEERING,ARCHITECTURE, PLANNING, SURVEYING& LANDSCAPE ARCHITECTURE THROUGHOUT THE MID-ATLANTIC REGION Department of Environmental Quality Division of Energy, Mineral, and Land Resources 225 Green Street, Suite 714 Fayetteville,NC 28301 Subject: Middle Point Project(SWA00230) MRA Project: 21814 State Stormwater Response to Comments Dear Jim Farkas: We have received your review comments for the above referenced project dated January 25, 2024, and made the changes as requested. Please find the updated plan set and response to comments letter enclosed. The review comments are listed below and have been addressed as follows: 1. Prior Comment l.a— "15A NCAC 02H.1003(1)(d)(i) — This project is shown as draining to... separate receiving waters,please provide documentation showing that each portion of the project is below the maximum allowable percent BUA for a low-density project or redesign as needed to meet the high-density requirements... Please revise as needed. " The drainage area divide for the project area as shown on plan sheet C1.0B does not reflect the proposed site grading. In "DA Divide" (attached), the area and roadway in the vicinity of Lots 241-244 etc... are shown to be in the part of the project that drains to Barbecue Creek, but actually appear to drain to Hickory Branch. In "DA Divide 2" (attached), outlets A3-79, A3-82, A3-85, etc... and their respective drainage areas are shown to be in the part of the project that drains to Barbecue Creek, but actually drain to Hickory Branch (some, such as A3-79, are fairly obvious). Please ensure that the drainage area divide for the project is accurate. Revise as needed. The drainage areas and subsequent B.U.A. calculations have been revised. Please see sheet C1.0B. 530 Hinton Pond Road, Suite 104, Knightdale, NC 27545 (984)200-2103 www.mragta.com Abingdon,MD ♦ Baltimore,MD ♦ Laurel,MD ♦ Towson,MD ♦ Georgetown,DE ♦ New Castle,DE ♦ Leesburg,VA ♦ Raleigh,NC (410)515-9000 (443)490-7201 (410)792-9792 (410)821-1690 (302)855-5734 (302)326-2200 (703)994-4047 (984)200-2103 DEMLR Re: Middle Point(SWA00230): Response to Comments Letter February 9,2024 Page 2 of 2 2. Prior Comment 1.e. — "15A NCAC 02H.1003(2)(d)(v) — The minimum required downstream length of vegetated area from a curb outlet system is 100 feet. There are a number of instances where this minimum length does not appear to be provided. Please ensure that this minimum flow length is provided." There still appears to be curb outlets that are located in such a manner that prohibit 100 feet of downstream vegetated area, specifically A2-1, A3-4, &A4-1 (see attached). The surface waters cannot be used as part of this 100 ft of vegetated area. Please revise as needed. NOTE: The plan sheets indicated in the response to comments (C4.10-C4.12) were not provided as part of the 12/29/23 resubmission. The aforementioned Catch Basins have been revised to ensure a minimum of 100' of downstream flow. Please See sheets C4.0-C4.9. 3. Prior Comment 4.a. — "Part D4—Please...provide a phone number and email address at which we can contact the property owner. " Please provide an email address for the Signing Official. Pages three and five of the ATC Application have been revised per comments #1 and #3. Please see the revised application in this resubmittal package. Sincerely, Morris &Ritchie Associates of NC, PC Edgar Rodriguez-Diaz DirectI984-200-2103 ErodriguezDiaz@mragta.com CC: Jeremy Keeny, PE, PLS