HomeMy WebLinkAboutWI0300475_Staff Report_20220602 Permit No. WI0300475
Date: June 2, 2022 County: Catawba
To: Michael Rogers, UIC Program_
Permittee/Applicant: (Owner) Jetzer Residence
Central Office Reviewer Michael Rogers
L GENERAL INFORMATION
1. This application is(check all that apply): ®New ❑ Renewal
❑ Minor Modification❑ Major Modification
a. Date of Inspection: 0512512022
b. Person contacted and contact information: Michael Jetzer(954)-415-5927- Cell Phone
c. Site visit conducted by: Edward Watson,Hydrogeologist
d. Inspection Report Printed from BIMS attached: ❑ Yes ®No.
e. Physical Address of Site including zip code: 5415 Little Parkway, Sherrills Ford, NC 28673
L Driving Directions if rural site and/or no physical address:
g. Latitude:35.588012 Longitude:-81.066275
Source of Lat./Long&Accuracy(i.e., Google Earth,GPS, etc.): GCS WGS 1984 to nearest 10 seconds.
II.DESCRIPTION OF INJECTION WELLS)AND FACILITY
1. Type of injection system:
® Geothermal Heating/Cooling Water Return
❑In situ Groundwater Remediation
❑Non-Discharge Groundwater Remediation
❑ Other(Specify:
2. For Geothermal Water Return Well(s) only
a. For existing geothermal system only:
Were samples collected from Influent/Effluent sampling ports? ❑ Yes ❑No.
Provide well construction information from well tag: N/A
b. Does existing or proposed system use same well for water source and injection? ❑ Yes ®No
If No,please provide source/supply well construction info(i.e., depth, date drilled,well contractor,
etc.) and attached map and sketch location of supply well in relation to injection well and any other
features in Section IV of this Staff Report.
3. Quality of drainage at site: ❑ Good ® Adequate ❑ Poor
4. Flooding potential of site: ® Low ❑ Moderate ❑ High
5. Does the map included in the Application reasonably represent the actual site (property lines,wells, surface
drainage)? ® Yes ❑No. If No, or no map,please attach a sketch of the site. Show property boundaries,
buildings,wells,potential pollution sources,roads, approximate scale,and north arrow.
III.E VAL UA TION AND RECOMMENDATIONS
1. Do you foresee any problems with issuance/renewal of this permit? ❑ Yes ®No. If Yes, explain.
2. List any items that you would like WQROS Central Office to obtain through an additional information request.
Make sure that you provide a reason for each item:
Item Reason
3. List specific special conditions or compliance schedules that you recommend to be included in the permit when
issued. Make sure that you provide a reason for each special condition:
Condition Reason
4. Recommendation
❑ Deny. If Deny,please state reasons:
❑ Hold pending receipt and review of additional information by Regional Office
❑ Issue upon receipt of needed additional information
® Issue
5. Signature of Report Preparer(s): Edward Watson Date 6/2/2022.
DocuSigned by:
Signature of WQROS Regional Supervisor: As-- aw H PU4." Date: 6/16/2022
F161FB69A2D84A3...
IV.ADDITIONAL REGIONAL STAFF REVIEW COMMENTS/ATTACHMENTS(Optional/If Needed)
During the site visit, DWR staff observed the test pits that were created for the Septic and Drain field. DWR
staff contacted Catawba County Environmental Health staff to eft information regarding soil type in the septic
and drain field prosed area. Mr. Steven Price of Catawba County Health indicated the soil type was not
Saprolitic in nature. The conversation with Mr. Price indicated that the septic tank and the drain field were to
be installed in soil profiles 4, 5, 7, &8. To a depth of 19"on the downhill side of the property. The soil type
was determined to be a Sandy Loam. A standard septic tank and drain field are to be installed to handle
residential wastewater.
The repair area is in soil profiles 1 &2. The soils in these pits are Saprolitic soils and the recommended
rgpair area would be subsurface drip irri ag tion.
Since the soils in the area closest to the infection well are not being characterized as Saprolitic, the setbackfor
the geothermal wells is 50 feet for the septic and drain field and the proposal meets that setback.
The property has a water supply well. The Well Tag information is below:
Depth to 265 ft. bls.
Static Water 70 ft.
Yield 12 GPM
8-inch diameter schedule 80 PVC casing to 62 ft
Installed 311112022