HomeMy WebLinkAboutNCG550062_Compliance Evaluation Inspection_20150904 Cat c il'� L Ji-L_ NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary September 4,2015 Mr. Harold Bagwell, Owner RECEIVED ,�' 1V ED 4653 Dick Wilson Road SEP 1 0 .- Denver, NC 28037 CENTRAL FILES SEP 2,13 DWR SECTION LCIVTlc�L FILES Subject: Notice of Deficiency DWR • Compliance Evaluation Inspection ECT70,, • NOD-2015-PC-0216 Bagwell Property Certificate of Coverage No. NAGS 6 Gaston County Dear Mr. Bagwell: Please find enclosed the Compliance Evaluation Inspection for the site visit conducted on August 11, 2015 by Mr. Ori Tuvia and myself. Your cooperation during the site visit was much appreciated. An area of concern is that annual effluent testing is not being performed as required by the permit.This testing is necessary to ascertain whether or not your wastewater treatment system is functioning properly. As discussed during the inspection,when effluent is not being generated for sampling,you may need to schedule your effluent collection on days when significant amounts of water will be used at the residence,such as on wash days. Please note that your prompt attention to these issues will help avoid future compliance problems. If you have any questions, please contact me at (704) 235-2194. Sincerely, 7zeo, Michael Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office, DWR • Enclosures 610 East Center Avenue,Suite 301,Mooresville,NC 28115 Phone:704-663-1699\Internet:www.ncwaterqualitv.org v United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e.,PCS) Transaction Code, NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IAI I. 2 3 I NCG550064 I11 12 I 15/08/11 117 18 1 ] 19 I s I 201 I 21111 I I I- I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I l f6 Inspection Work Days Facility Self-Monitoring Evaluation Rating 81 QA ------- Reserved---- — 67 I 70 71 I I 72 1 ,, 731 I 174751 I I I I I I I80 L_1 Section B:Facility Data L-1 t Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:OOAM 15/08/11 13/08/01 6622 Denver Heights Circle 6622 Denver Hts Cir Exit Time/Date Permit Expiration Date Denver NC 28037 - • 09:45AM 15/08/11 18/07/31 Name(s)of Onsite Representative(s)lTitles(s)/Phone and Fax Number(s) Other Facility Data /// Harold W Bagwell/// Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Harold Wayne Bagwell,4653 Dick Wilson Rd Denver NC 280378174/New Owner// Yes Section C:Areas Evaluated During Inspection(Check only those areas evaluated) In Permit II Operations&Maintenance 1. Records/Reports Self-Monitoring Program Facility Site Review I. Effluent/Receiving Waters Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) , Agency/Office/Phone and Fax Numbers Date Michael L Parker MRO WQ//704-663-1699 Ext.2194/ On A Tuvia MRO WQ//704-663-1699/ ' ature of Management Q A Revie Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 d NPDES yr/mo/day Inspection Type (Cont.) 1 31 NCG550064 I11 12I 15/08/11 117 18 I C Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) The wastewater treatment facility serving the subject residence was in good operational condition at the time of the site inspection. The septic tank has been pumped regularly and chlorine tablets used for wastewater treatment were present in the disenfection tubes. Effluent was not,observed coming out of the discharge pipe, and there were no solids deposition at either the outlet or instream. There was no evidence that gray water was by-passing the treatment system: • The permittee has not sampled the effluent on an annual basis as required by the permit.This was discussed with the permittee at the time of the site visit. V • Page# 2 Permit: NCG550064 Owner-Facility: 6622 Denver Heights Circle Inspection Date: 08/11/2015 Inspection Type. Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ 0 Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable ❑ ❑ ■ ❑ Solids,pH, DO,Sludge Judge,and other that are applicable? - - Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ■ 0 application? Is the facility as described in the permit? • ❑ ❑ ❑ #Are there any special conditions for the permit? ❑ ■ ❑ 0 Is access to the plant site restricted to the general public? ❑ ❑ I ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: Effluent Samplinq 0 Yes No NA NE Is composite sampling flow proportional? ❑ ❑ • ❑ Is sample collected below all treatment units? ❑ ❑ IN ❑ Is proper volume collected? ❑ ❑ I ❑ Is the tubing clean? ❑ ❑ MI ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees ❑ ❑ II ❑ - Celsius)? Is the facility sampling performed as required by the permit(frequency,sampling type ❑ ❑ I ❑ representative)? • Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? IM ❑ ❑ ❑ Are the tablets the proper size and type? I ❑ ❑ ❑ Number of tubes in use? Is the level of chlorine residual acceptable? ❑ ❑ ❑ • Is the contact chamber free of growth,or sludge buildup? ❑ ❑ ❑ MI Is there chlorine residual prior to de-chlorination? ❑ ❑ • ❑ Comment: Page# 3 Permit: NCG550064 Owner-Facility: 6622 Denver Heights Circle Inspection Date: 08/11/2015 Inspection Type: Compliance Evaluation Septic Tank Yes No NA NE' (If pumps are used)Is an audible and visual alarm operational? ❑ ❑ NI ❑ Is septic tank pumped on a schedule? • ❑ 0 ❑ Are pumps or syphons operating properly? 0 0 0 ®• Are high and low water alarms operating properly? ❑ ❑ 0 ❑ Comment: Page# 4