February 09, 2024
SUBJECT: COMPLIANCE EVALUATION INSPECTION AND NOTICE OF VIOLATION
Tracking Number: NOV-2024-PC-0103
Permit No. NCG590019
Ramseur WTP
Randolph County
Dear Ms. Caudle:
On January 17, 2024, Division of Water Resources (DWR) Winston-Salem Regional Office (WSRO)
staff Jesse Barnes conducted a routine compliance evaluation inspection at the Ramseur WTP in
reference to NPDES general permit NCG590000 and certificate of coverage NCG590019. ORC
Terry Lewallen and Utilities Director Jason Helton were present during the inspection. A review
of the subject permit, records, data, laboratory, treatment components, sampling methods, outfall
area, operations, and maintenance was completed. This review reflected noncompliance with the
subject permit. The determined permit violations and items of concern are listed below.
Inspection findings are detailed in the attached Water Compliance Inspection Report.
Permit Violations
According to DWR records, a Back-up ORC has not been properly designated and reported
to the Division. Part II, Section C. (1.) (b.) of the subject permit requires the permit owner
to designate at least one Back-up ORC who possesses a valid certificate of the type of
system and no more than one grade less than the grade of the system. Please complete
and submit the attached ORC Designation Form with the required Back-up ORC
information.
Items of Concern
Field laboratory parameters have been performed by the Ramseur WTP field lab (NC
certified lab #5270), but this information has not been listed on discharge monitoring
reports (DMRs). Please list all certified labs used during each month on future DMRs.
Plans or measures should be taken to address the indicated violation(s) and/or item(s) of concern,
if applicable. Please be aware that the Division may take enforcement action against any individual
who fails to comply with the requirements of all applicable permits, regulations, and/or statutes.
Pursuant to NC General Statute (NCGS) 143-215.6A, a civil penalty of not more than twenty-five
thousand dollars ($25,000.00) may be assessed against any person who violates or fails to act in
D North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105
Moan caaouNn 336.776.9800
oep.m.m or em�nmen� Qualm
accordance with the terms, conditions, or requirements of any permit, or applicable regulations,
issued pursuant to G.S. 143-215.1.
If you have questions or concerns, contact Jesse Barnes by phone at 336-776-9701 or by email
at iesse.barnes@deq.nc.gov.
Sincerely,
DocuSigned by:
OD2D3CE3F1 B7456...
Jennifer F. Graznak, Assistant Regional Supervisor
Water Quality Regional Operations Section
Winston-Salem Regional Office
Division of Water Resources, NCDEQ
Attachments:
1. Water Compliance Inspection Report, NCG590019
2. ORC Designation Form
REQ� North Carolina Department ofEnvironmental Quality I Division ofWater Resources
Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 1 Raleigh, North Carolina 27105
NORTH CAROLINA 336.776.9800
naparMeM of EmironmanW 9uallly
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 u 3 I NCG590019 I11 121 24/01/17 I17 18I � I 19 I s I 20L]
21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
I 72 I n, I 71 I 74 79 I I I I I I I80
701 I 71 I LL -1 I I
LJ
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Dermit Number)
12:OOPM 24/01/17
19/09/01
Ramseur WTP
797 NC Hwy 22 N
Exit Time/Date
Permit Expiration Date
Franklinville NC 27248
01:OOPM 24/01/17
24/07/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Terry Cheyenne Lewallen/ORC/336-824-3939/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Vicki Caudle,PO Box 545 Ramseur NC 273160545/Mayor/336-824-4111/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Jesse Barnes Docusigned by: DWR/WSRO WQ/336-776-9701/ 2/9/2024
� 5 Ba4~0'
E
41797473D3194ED...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
Docusigned by:
DWR/WSRo 336-776-9695 2/9/2024
'---OD2D3CE3F 1 B7456_.
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCG590019 I11 12I 24/01/17 117 18 ici cJ
(Cont.)
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
On January 17, 2024, Division of Water Resources (DWR) Winston-Salem Regional Office (WSRO)
staff Jesse Barnes conducted a routine compliance evaluation inspection at the Ramseur WTP in
reference to NPDES general permit NCG590000 and certificate of coverage NCG590019. ORC Terry
Lewallen and Utilities Director Jason Helton were present during the inspection. A review of the
subject permit, records, data, laboratory, treatment components, sampling methods, outfall area,
operations, and maintenance was completed. This review reflected noncompliance with the subject
permit. The determined permit violations and items of concern are listed below. Inspection findings
are detailed in the attached Water Compliance Inspection Report.
Permit Violations:
1. According to DWR records, a Back-up ORC has not been properly designated and reported to
the Division. Part II, Section C. (1.) (b.) of the subject permit requires the permit owner to designate at
least one Back-up ORC who possesses a valid certificate of the type of system and no more than one
grade less than the grade of the system. Please complete and submit the attached ORC Designation
Form with the required Back-up ORC information.
Items of Concern:
1. Field laboratory parameters have been performed by the Ramseur WTP field lab (NC certified lab
#5270), but this information has not been listed on discharge monitoring reports (DMRs). Please list
all certified labs used during each month on future DMRs.
Other observations:
NPDES general permit NCG590000 became effective August 1, 2019, and will expire at midnight on
July 31, 2024. Certificate of coverage NCG590019 became effective June 1, 2021, and will remain in
effect for the duration of the general permit. The facility is a conventional WTP discharging to
freshwater and therefore required to monitor and report according to Part I, Section B. (4.) of the
subject permit.
The discharge monitoring report (DMR) and associated laboratory records for September 2023 were
reviewed during the inspection and appeared to be complete with no errors found. The benchtop
DR3900 used to analyze total chlorine is calibrated annually by Meritech Inc and calibration records
appeared to be complete.
A diesel standby power generator is available in the event of power failures. The generator is
automatically activated, can power the entire facility, and is tested once per month by interrupting the
primary power source. Records of generator testing were available during the inspection and
appeared to be complete.
Wastewater is treated by a clarifier to remove excess solids and then de -chlorinated by feeding liquid
sodium thiosulfate into the center well of the clarifier. The clarifier and de -chlorination system
appeared to be operating properly during the inspection.
Effluent flow is estimated based on the change in water depth within the clarifier over time. Facility
staff estimate 9,000 gallons of effluent flow for every foot of water depth change in the clarifier. Mr.
Helton stated that a leaky valve controlling effluent flow from the clarifier to the outfall causes
constant effluent flow and limits the staff's ability to totally stop effluent flow.
Instream and effluent sampling locations and methods were verified during the inspection and
appeared to comply with the subject permit.
Page#
Permit: NCG590019
Inspection Date: 01/17/2024
Owner -Facility: Ramseur WTP
Inspection Type: Compliance Evaluation
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment:
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
❑ ❑ ■ ❑
❑ ❑ ■ ❑
❑ ■ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
■ ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ ■
El
El
■ ❑ ❑ ❑
❑ ❑ ■ ❑
❑ ❑ ■ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ■ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
Comment: According to DWR records, a Back-up ORC has not been properly designated and
reported to the Division.
Laboratory
Yes No NA NE
Page# 3
Permit: NCG590019 Owner -Facility: Ramseur WTP
Inspection Date: 01/17/2024 Inspection Type: Compliance Evaluation
Laboratory
Yes
No
NA
NE
Are field parameters performed by certified personnel or laboratory?
0
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
0
❑
❑
❑
# Is the facility using a contract lab?
■
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
❑
❑
❑
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
❑
❑
❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
❑
❑
❑
Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Standby Power
Yes
No
NA
NE
Is automatically activated standby power available?
0
❑
❑
❑
Is the generator tested by interrupting primary power source?
■
❑
❑
❑
Is the generator tested under load?
0
❑
❑
❑
Was generator tested & operational during the inspection?
❑
❑
❑
Do the generator(s) have adequate capacity to operate the entire wastewater site?
0
❑
❑
❑
Is there an emergency agreement with a fuel vendor for extended run on back-up
❑
❑
❑
■
power?
Is the generator fuel level monitored?
0
❑
❑
❑
Comment:
De -chlorination
Yes No
NA
NE
Type of system ?
Liquid
Is the feed ratio proportional to chlorine amount (1 to 1)?
❑ ❑
❑
Is storage appropriate for cylinders?
❑ ❑
0
❑
# Is de -chlorination substance stored away from chlorine containers?
❑ ❑
❑
Comment:
Are the tablets the proper size and type? ❑ ❑ 0 ❑
Are tablet de -chlorinators operational? ❑ ❑ 0 ❑
Page# 4
Permit: NCG590019 Owner -Facility: Ramseur WTP
Inspection Date: 01/17/2024 Inspection Type: Compliance Evaluation
De -chlorination Yes No NA NE
Number of tubes in use?
Comment:
Flow Measurement - Effluent
Yes
No
NA
NE
# Is flow meter used for reporting?
❑
0
❑
❑
Is flow meter calibrated annually?
❑
❑
0
❑
Is the flow meter operational?
❑
❑
0
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
0
❑
Comment:
Effluent Sampling
Yes
No
NA
NE
Is composite sampling flow proportional?
❑
❑
0
❑
Is sample collected below all treatment units?
0
❑
❑
❑
Is proper volume collected?
❑
❑
❑
■
Is the tubing clean?
❑
❑
■
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
❑
❑
❑
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
0
❑
❑
❑
representative)?
Comment:
Effluent Pipe
Yes
No
NA
NE
Is right of way to the outfall properly maintained?
0
❑
❑
❑
Are the receiving water free of foam other than trace amounts and other debris?
0
❑
❑
❑
If effluent (diffuser pipes are required) are they operating properly?
❑
❑
■
❑
Comment:
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, 0 ❑ ❑ ❑
and sampling location)?
Comment:
Page# 5