HomeMy WebLinkAbout20231123 Ver 1_USACE Permit_20240129Electronic Transmittal
U.S. ARMY CORPS OF ENGINEERS
WILMINGTON DISTRICT
Action Id. SAW-2000-00502 County: Carteret U.S.G.S. Quad: NC -Morehead City
GENERAL PERMIT (REGIONAL AND NATIONWIDE) VERIFICATION
Permittee HBCC Properties, LLC C/o Lynn Hudson
Address: 1450 East Arlington Blvd Suite A
Greenville NC 27858
Telephone Number: 252-353-2000
E-mail: elhudsonAhudsonbros.co
Size (acres) 8.4 acre Nearest Town Morehead City
Nearest Waterway Peltier Creek River Basin White Oak
USGS HUC 030203010702 Coordinates Latitude: 34.728510
Longitude:-76.766434
Location description: The project This tract is located on Friendly Road in Morehead City, Carteret County, North Carolina.
Description of projects area and activity: This verification authorizes permanent impacts to 0.216 acre of permanent wetland
impacts. The project is to storage unit facility will hold two self -storage buildings and a stormwater pond.
Applicable Law(s): ❑x Section 404 (Clean Water Act, 33 USC 1344)
El Section 10 (Rivers and Harbors Act, 33 USC 403)
Authorization: Nationwide Permit's # 's 18 & 39
SEE ATTACHED NWP GENERAL, REGIONAL, AND/OR SPECIAL CONDITIONS
Your work is authorized by the above referenced permit provided it is accomplished in strict accordance with the attached
Conditions, your application signed and dated 8/3/2023, and the enclosed SITE PLAN & wetland impact 1: 0.12 & 2: 0.096,.
Nobles Division Tract 1, date 4/13/23. Any violation of the attached conditions or deviation from your submitted plans may
subject the permittee to a stop work order, a restoration order, a Class I administrative penalty, and/or appropriate legal
action.
This verification will remain valid until the expiration date identified below unless the nationwide and/or regional general permit
authorization is modified, suspended or revoked. If, prior to the expiration date identified below, the nationwide and/or regional general
permit authorization is reissued and/or modified, this verification will remain valid until the expiration date identified below, provided
it complies with all requirements of the modified nationwide permit. If the nationwide and/or regional general permit authorization
expires or is suspended, revoked, or is modified, such that the activity would no longer comply with the terms and conditions of the
nationwide permit, activities which have commenced (i.e., are under construction) or are under contract to commence in reliance upon
the nationwide and/or regional general permit, will remain authorized provided the activity is completed within twelve months of the
date of the nationwide and/or regional general permit's expiration, modification or revocation, unless discretionary authority has been
exercised on a case -by -case basis to modify, suspend or revoke the authorization.
Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You
should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements.
For activities occurring within the twenty coastal counties subject to regulation under the Coastal Area Management Act (CAMA), prior
to beginning work you must contact the N.C. Division of Coastal Management in Wilmington, NC, at (910) 796-7215.
This Department of the Army verification does not relieve the permittee of the responsibility to obtain any other required Federal, State
or local approvals/permits. If there are any questions regarding this verification, any of the conditions of the Permit, or the Corps of
Engineers regulatory program, please contact Thomas Charles at (910) 251-4101or Thomas.p.charles(a,usace.army.mil.
CorpsRegulatory Thomas Charles Digitally signed by Thomas Charles
Co s Official: Date: 2024.01.29 13:53:20 -05'00' Date: 1/29/2024
Expiration Date of Verification: 3/22/2026
SSMH RIM = 16.51
FLnWLINF = 5.31
SSMH RIM = 20.01
FLOWLINE = 4.36
24 " RC
NOTE:
1) TRACT 1 AREA = 360.834.50 S.F. OR 8.28 ACRES
2) AREA BY COORDINATES.
3) ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES.
4) THIS MAP IS NOT FOR RECORDING.
5) THIS SURVEY IS OF AN EXISTING PARCEL OF LAND.
6) NO TOPOGRAPHICAL INFORMATION TAKEN INSIDE OF WETL
7) 10' SIDEWALK & UTILITY EASEMENT ON PROPERTY ADJAC
SEE MAP BOOK 29 PAGE 884.
8) THIS PROPERTY LOCATED IN FLOOD ZONE X.
9) 25' FRONT SETBACK ALONG FRIENDLY ROAD AND BRIDGES
MAP BOOK 29 PAGE 884.
10) TRACT IS WOODED AND VACANT.
LEGEND
EIR EXISTING IRON RDD
EIP EXISTING IRON PIPE
EPK EXISTING PK NAIL
ECM EXISTING CONC. MON.
ERRS EXISTING R/R SPIKE
SIR SET IRON ROD
CP CALCULATED POINT
MHW MEAN HIGH WATER
N/F NOW OR FORMERLY
MB MAP BOOK
DB DEED BOOK
PG PAGE
PP POWER POLE
LP LIGHT POLE
OE OVERHEAD ELECTRIC
ELEC ELECTRICAL PEDESTAL
TRANS ELEC. TRANSFORMER
TEL TELEPHONE PEDESTAL
TV CABLE TV PEDESTAL
WM WATER METER
CO CLEAN OUT
CONC CONCRETE
VICINITY MAP (NITS)
=RET PLACE INVEST., LLC
J PG. 74
'G. 731
7613137963000
TAINING WALL
NV = 22.36'
THE BLUFFS LAND CO.. LLC
1146 PG. 137
29 PG. 884
'IN 637613137254000
,RESS: 4010 BRIDGES
B.69
5.59
STREET
FROM
521
TO
522.
S 85
22
21.918
W.
232507
� NT
FROM
522
TO
523,
S 87
16
58.520
W.
28:6009
FROM
523
TO
524.
N 65
55
41.117
W.
67.5307
FROM
524
TO
527.
N 55
04
33.463
W.
45.8322
FROM
527
TO
528.
N 55
09
51.053
W.
40.4864
FROM
528
TO
529.
N 41
41
32.657
W.
30.4087
FROM
529
TO
539.
N 22
05
32.319
E.
14.7323
FROM
539
TO
540.
N 10
ll
28.575
W.
27.9662
FROM
540
TO
541.
N 28
29
31.564
E.
49.8615
FROM
541
TO
542.
N 46
10
48.746
E.
35.6419
REVISIONS:
FROM
542
TO
543.
N 48
31
34.694
E.
35.5664
FROM
543
TO
544.
S 78
13
41.635
E.
39.0288
Na
BY
DATE
FROM
544
TO
545.
S 72
45
06.003
E.
20.6452
FROM
545
TO
548.
N 69
45
02.998
E.
36.3776
REFERENCES:
FROM
548
TO
549.
S 57
32
08.251
E.
40.8011
OWNER: N/F JOHN NOBLES. JR.
FROM
549
TO
550.
S 77
37
24.913
E.
43.3936
D.B. 770 P G. 99 01
FROM
550
TO
551.
S 63
12
07.857
E.
37.3731
M.B. 29 PG. 884
FROM
551
TO
552.
S 74
54
34.702
E.
41.0748
FROM
552
TO
553.
N 88
46
00.692
E.
31.3884
NCP I N 63761313241 7000
FROM
553
TO
554,
S 72
58
21.389
E.
49.1772
ADDRESS: 200 FRIENDLY ROAD
FROM
554
TO
557,
N 20
20
50.190
W.
33.8912
WA21 WAS SKIPPED
WA30 WAS USED TWICE
WA36 WAS USED TWICE
PRELIMINARY NOT FOR RECORDING
PROJECT No. PM2378-003
SAW-2000-00502
SPECIAL CONDITIONS
MITIGATION: The applicant proposes to purchase 0.4 acre of non -riparian wetland credits from the NC DMS.
Action ID Number: SAW-2000-00502 County: Carteret
Permittee: HBCC Properties, LLC C/o Lynn Hudson
Project Name: Bridges Street Mini Storge /Friendly Road Storage
Date Verification Issued: 1/29/2024
Project Manager: Thomas Charles
Upon completion of the activity authorized by this permit and any mitigation required by the permit,
sign this certification and return it to the following address:
US ARMY CORPS OF ENGINEERS
WILMINGTON DISTRICT
Attn: Thomas Charles
Wilmington Regulatory Office
U.S Army Corps of Engineers
69 Darlington Avenue
Wilmington, North Carolina 28403
or
Thomas.p.charles@usace.army.mil
Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of
Engineers representative. Failure to comply with any terms or conditions of this authorization may
result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I
administrative penalty, or initiating other appropriate legal action.
I hereby certify that the work authorized by the above referenced permit has been completed in
accordance with the terms and condition of the said permit, and required mitigation was completed in
accordance with the permit conditions.
Signature of Permittee
Date
U.S. ARMY CORPS OF ENGINEERS
Wilmington District
Compensatory Mitigation Responsibility Transfer Form
Permittee: HBCC Properties, LLC C/o Lynn Hudson Action ID: SAW-2000-00502
Project Name: Bridges Street Mini Storge. County: Carteret
Instructions to Permittee: The Permittee must provide a copy of this form to the Mitigation Sponsor, either an approved
Mitigation Bank or the North Carolina Division of Mitigation Services (NCDMS), who will then sign the form to verify the
transfer of the mitigation responsibility. Once the Sponsor has signed this form, it is the Permittee's responsibility to ensure
that Wilmington District Project Manager identified on page two is in receipt of a signed copy of this form before conducting
authorized impacts, unless otherwise specified below. If more than one Mitigation Sponsor will be used to provide the
mitigation associated with the permit, or if the impacts and/or the mitigation will occur in more than one 8-digit Hydrologic
Unit Code (HUC), multiple forms will be attached to the permit, and the separate forms for each Sponsor and/or HUC must
be provided to the appropriate Mitigation Sponsors.
Instructions to Sponsor: The Sponsor verifies that the mitigation requirements (credits) shown below have been released
and are available at the identified site. By signing below, the Sponsor is accepting full responsibility for the identified
mitigation, regardless of whether they have received payment from the Permittee. Once the form is signed, the Sponsor
must update the bank ledger and provide a copy of the signed form and the updated ledger to the Permittee, the Project
Manager who issued the permit, the Bank Project Manager, and the District Mitigation Office (see contact information on
page 2). The Sponsor must also comply with all reporting requirements established in their authorizing instrument.
Permitted Impacts and Compensatory Mitigation Requirements:
Permitted Impacts Requiring Mitigation* 8-digit HUC and Basin: 03020106, White Oak River Basin
Stream Impacts (linear feet)
Wetland Impacts (acres)
Warm
Cool
Cold
Riparian Riverine
Riparian Non-Riverine
Non -Riparian
Coastal
0.216
*If more than one mitigation sponsor will be used for the permit, only include impacts to be mitigated by this sponsor.
Compensatory Mitigation Requirements: 8-digit HUC and Basin: 03020106, White Oak River Basin
Stream Mitigation (credits)
Wetland Mitigation (credits)
Warm
Cool
Cold
Riparian Riverine
Riparian Non-Riverine
Non -Riparian
Coastal
0.4
Mitigation Site Debited: _NC DMS. White Oak River Basin
(List the name of the bank to be debited. For umbrella banks, also list the specific site.
acceptance letter identifies a specific site, also list the specific site to be debited).
For NCDMS, list NCDMS. If the NCDMS
Section to be completed by the Mitigation Sponsor
Statement of Mitigation Liability Acceptance: I, the undersigned, verify that I am authorized to approve mitigation
transactions for the Mitigation Sponsor shown below, and I certify that the Sponsor agrees to accept full responsibility for
providing the mitigation identified in this document (see the table above), associated with the USACE Permittee and Action
ID number shown. I also verify that released credits (and/or advance credits for NCDMS), as approved by the Wilmington
District, are currently available at the mitigation site identified above. Further, I understand that if the Sponsor fails to provide
the required compensatory mitigation, the USACE Wilmington District Engineer may pursue measures against the Sponsor to
ensure compliance associated with the mitigation requirements.
Mitigation Sponsor Name:
Name of Sponsor's Authorized Representative:
Page 1 of 2 Form Version 10 June 2020updated
Signature of Sponsor's Authorized Representative Date of Signature
Conditions for Transfer of Compensatory Mitigation Credit:
• Once this document has been signed by the Mitigation Sponsor and the District is in receipt of the signed form, the
Permittee is no longer responsible for providing the mitigation identified in this form, though the Permittee remains
responsible for any other mitigation requirements stated in the permit conditions.
• Construction within jurisdictional areas authorized by the permit identified on page one of this form can begin only after
the District is in receipt of a copy of this document signed by the Sponsor, confirming that the Sponsor has accepted
responsibility for providing the mitigation requirements listed herein. When NCDMS provides mitigation for authorized
impacts conducted bythe North Carolina Department of Transportation (NCDOT), construction within jurisdictional areas
may proceed upon permit issuance; however, a copy of this form signed by NCDMS must be provided to the District
within 30 days of permit issuance. NCDOT remains fully responsible for the mitigation until the District has received this
form, confirming that the Sponsor has accepted responsibility for providing the mitigation requirements listed herein.
• Signed copies of this document must be retained by the Permittee, Mitigation Sponsor, and in the USACE administrative
records for both the permit and the Bank/ILF Instrument. It is the Permittee's responsibility to ensure that the District
Project Manager (address below) is provided with a signed copy of this form.
• If changes are proposed to the type, amount, or location of mitigation after this form has been signed and returned to
the District, the Sponsor must obtain case -by -case approval from the District Project Manager and/or North Carolina
Interagency Review Team (NCIRT). If approved, higher mitigation ratios may be applied, as per current District guidance
and a new version of this form must be completed and included in the District administrative records for both the permit
and the Bank/ILF Instrument.
Comments/Additional Conditions: A letter from Kelly Williams, confirming they are willing and able to accept the
applicant's compensatory mitigation responsibility, dated 7/28/2023 was included with the preconstruction notification.
This form is not valid unless signed below by the District Project Manager and by the Mitigation Sponsor on Page 1. Once
signed, the Sponsor should provide copies of this form along with an updated bank ledger to: 1) the Permittee, 2) the
District Project Manager at the address below, 3) the Bank Manager listed in RIBITS, and 4) the Wilmington District
Mitigation Office, 3331 Heritage Trade Drive, Suite 105, Wake Forest, NC27587 (or by email to SAWMIT@usace.arm y.mil).
Questions regarding this form or any of the permit conditions may be directed to the District Mitigation Office.
USACE Project Manager: Thomas Charles
USACE Field Office: Wilmington Regulatory Office
US Army Corps of Engineers
69 Darlington Avenue
Wilmington, North Carolina 28403
Email: Thomas. p.charles@usace.army.miI
Thomas Charles Digitally signed by Thomas Charles
Date: 2024.01.29 13:52:49-05'00'
USACE Project Manager Signature
1/29/2024
Date of Signature
Current Wilmington District mitigation guidance, including information on mitigation ratios, functional assessments, and
mitigation bank location and availability, and credit classifications (including stream temperature and wetland groupings) is
available at http://ribits.usace.army.mi1.