Loading...
HomeMy WebLinkAboutNC0023736_Compliance Evaluation Inspection_20220209DocuSign Envelope ID: 08FBFBEA-9F9A-4EC8-A5FA-6D2D7840BBB0 ROY COOPER Governor ELIZABETH S. BISER �. • , ,I Secretary 5. DANIEL SMITH NORTH CAROUNA Director Environmental Qualify SENT VIA ELECTRONIC MAIL ONLY: NO HARD COPY WILL BE MAILED. February 9, 2022 Elisa R. Triplett, Wastewater Superintendent City of Lenoir Lower Creek WWTP E-mail: I rtriplett@CI. LENOIR. NC. US SUBJECT: Compliance Inspection Report Gunpowder Creek WWTP NPDES WW Permit No. NCO023736 Caldwell County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Gunpowder Creek WWTP on 2/08/2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0023736. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact me with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500 or via email at tim.heim@ncdenr.gov. Sincerely, EDocuSigned by: fiKAbfAj �uwA 082 10�SA3CA 18 Tim elm, .E. —Environmental Engineer Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Ec: LF, Radford Thomas — City of Lenoir D ��� North Carolina Depar[merrtaf Environmental Qualrcylolvlsbnaf Wazer Resources -/ Asheville Regional Office 1209005, Highway 701 5wannan- Noah Carolha 28775 82&296 Me DocuSign Envelope ID: 08FBFBEA-9F9A-4EC8-A5FA-6D2D7840BBB0 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO023736 111 121 22/02/08 I17 18 LC] I 19 I s I 201 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:00AM 22/02/08 21/04/01 Gunpowder Creek WWTP 450 Pine Mtn Rd Exit Time/Date Permit Expiration Date Hudson NC 28638 01:30PM 22/02/08 26/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Donnie Robert Hawkins/ORC/828-757-2198/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Elisa Robbins Triplett,PO Box 958 Lenoir NC 286450958H828-757-4462/ Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Timothy H Heim D �s/'II�db. DWR/ARO WQ/828-296-4665/ 2/9/2022 �iw,o{%u� (fiuw, CG-1 Mikal Willmer DWR/Division of Water Qua D- 90P°bya,a 2/9/2022 K" Wil-ft Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date e 25' Eb 2/9/2022 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: 08FBFBEA-9F9A-4EC8-A5FA-6D2D7840BBB0 NPDES yr/mo/day Inspection Type (Cont.) NCO023736 I11 12I 22/02/08 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Tim Heim and Mikal Willmer of the Asheville Regional Office performed a Compliance Inspection of the Facility on February 8, 2022. Lisa Triplett and Donnie Hawkins (City of Lenoir) were present and assisted with the inspection. The facility appeared well maintained and operated at the time of the inspection, and in compliance with Permit NC0023736. Upgrades and improvements been made to the facility since the last inspection including: A new sludge storage tank. A new influent flow proportional auto -sampler. Replacement of all influent pumps. Replacement of the bar screen. Page# DocuSign Envelope ID: 08FBFBEA-9F9A-4EC8-A5FA-6D2D7840BBB0 Permit: NCO023736 Owner -Facility: Gunpowder Creek WWTP Inspection Date: 02/08/2022 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ■ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑ Is the wet well free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ Are float controls operable? 0 ❑ ❑ ❑ Is SCADA telemetry available and operational? 0 ❑ ❑ ❑ Is audible and visual alarm available and operational? M ❑ ❑ ❑ Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual ❑ b.Mechanical Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Page# 3 DocuSign Envelope ID: 08FBFBEA-9F9A-4EC8-A5FA-6D2D7840BBB0 Permit: NC0023736 Owner -Facility: Gunpowder Creek WWTP Inspection Date: 02/08/2022 Inspection Type: Compliance Evaluation Grit Removal Yes No NA NE Type of grit removal a.Manual ❑ b.Mechanical Is the grit free of excessive organic matter? ■ ❑ ❑ ❑ Is the grit free of excessive odor? 0 ❑ ❑ ❑ # Is disposal of grit in compliance? 0 ❑ ❑ ❑ Comment: Sequencing Batch Reactors Yes No NA NE Type of operation: Simplex, Multiple Is the reactor effluent free of solids? ❑ ❑ ❑ Does minimum fill time correspond to the peak hour flow rate of the facility? ❑ ❑ ❑ Is aeration and mixing cycled on and off during fill? ❑ ❑ ❑ The operator understands and can explain the process? ❑ ❑ ❑ Comment: Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Is the generator tested by interrupting primary power source? 0 ❑ ❑ ❑ Is the generator tested under load? ■ ❑ ❑ ❑ Was generator tested & operational during the inspection? ❑ ❑ ❑ Do the generator(s) have adequate capacity to operate the entire wastewater site? 0 ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up ■ ❑ ❑ ❑ power? Is the generator fuel level monitored? E ❑ ❑ ❑ Comment: Disinfection -Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? 0 ❑ ❑ ❑ (Sodium Hypochlorite) Is pump feed system operational? 0 ❑ ❑ ❑ Is bulk storage tank containment area adequate? (free of leaks/open drains) 0 ❑ ❑ ❑ Is the level of chlorine residual acceptable? 0 ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Page# 4 DocuSign Envelope ID: 08FBFBEA-9F9A-4EC8-A5FA-6D2D7840BBB0 Permit: NCO023736 Owner -Facility: Gunpowder Creek WWTP Inspection Date: 02/08/2022 Inspection Type: Compliance Evaluation Disinfection -Liquid Yes No NA NE Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected above side streams? 0 ❑ ❑ ❑ Is proper volume collected? ■ ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 0 ❑ ❑ ❑ degrees Celsius)? Is sampling performed according to the permit? 0 ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? ■ ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ■ ❑ ❑ ❑ representative)? Comment: Page# 5