Loading...
HomeMy WebLinkAboutNC0040070_Fact Sheet_20150112PV DENR / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT DEVELOPMENT NPDES Permit NCO040070 Derek Denard, Compliance & Expedited Permitting Unit / 919-807-6307 12Jan20I5 Facility Information Applicant/Facility Name City of Gastonia — Two Rivers Utilities WTP Alum De -watering Facility Applicant Address P.O. Box 1748, Gastonia, NC 28053 Facility Address 298 West Page Avenue, Gastonia, NC 28052 Permitted Flow (MGD) Not limited Type of Waste Water Plants and Water Conditioning Discharge —filter-backwash - Conventional WTP System Facility Class PC-1 County Gaston Permit Status Renewal Regional Office MRO Stream Characteristics Receiving Stream UT to Long Creek Stream Classification C Stream Segment [11-129-16-(4)] Drainage basin Catawba Summer 7Q10 (cfs) 0 Subbasin 03-08-36 Winter 7Q10 (cfs) 0 Use Support Aquatic Life 30Q2 (cfs) 0 303(d) Listed Impaired for Turbidity Average Flow (cfs) 0 State Grid F14SW IWC (%) 100% USGS Topo Quad Gastonia North, NC Facility Summary This facility is a conventional technology water treatment plant [coagulation, flocculation, sedimentation, and filtration] with discharge of wastewaters from media filter backwash and sedimentation basins with a design potable flowrate of 23.30 MGD and a wastewater discharge of 0.75 MGD. Because the waste flow is >50k gpd, continuous flow monitoring is required. The facility consists of the following water and wastewater treatment units: • coagulation • disinfection equipment • two (2) 0.600 MG sedimentation basin • filtration • alum sludge de -watering facility • dechlorination equipment • chemical usage consists of o aluminum sulfate o sodium hypochlorite o sodium hydroxide o sodium bicarbonate o hexameta-phosphate Fact Shcet RencN+al 2015 -- N D1S Permit N00040070 Payc I 0 orthophosphate o fluoride o polymer o sodium thiosulfate Monthly age FLOW (MGD) — Backwash or reject flow 0.75(MAX). Eligibility for Coverage Under the General Permit NCG590000 — The Two Rivers Utilities Water Treatment Plant (WTP) is not eligible for the general permit because there is not enough toxicity data. At least one permit cycle of toxicity data for is needed to determine eligibly. Toxici — With an IWC >0.25%, this permit requires Chronic Whole Effluent Toxicity (WET) testing using Ceriodaphnia dubia to be performed as a 7-day pass/fail test at 90% effluent concentration, during January, April, July and October [TGP3B]. For Renewal — This permit reflects discharge at Outfall 001. DWR updated the facility description and Map; added parameter codes to Section A. (L); added Electronic Reporting - Discharge Monitoring Reports page [Section A. (2.)]; changed flow monitoring to Continuous and Recording; added quarterly Total Zinc monitoring; and added weekly Turbidity monitoring with limit. Stream — Discharge from WTP for outfall 001 is into the an unnamed tributary to Long Creek [Stream Segment 11-129-16-(4)]. The segment is currently listed in the 2012 North Carolina 303(d) List as impaired for Turbidity. RPA — A RPA was not conducted. The most recent data was in February 2006 for Iron and Aluminum. Fact Shcct Renoal 2015 -- NPDI;S NOW40070 Page 2