HomeMy WebLinkAboutWQ0044546_More Information (Requested)_20230918ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS,]R.
Director
JAMES SCOTT JONES - MANAGER
PRINCESS HOLDINGS, LLC
1430 INNOVATION AVENUE
MORRISVILLE, NORTH CAROLINA 27560
Dear Mr. Jones:
NORTH CAROLINA
Environmental Quality
September 18, 2023
Subject: Application No. WQ0044546
Additional Information Request #1
6708 Bartley Point West SFR
Single -Family Residence
Wastewater Irrigation System
Wake County
Division of Water Resources' Central and Regional staff has reviewed the application package
received on July 3, 2023. However, additional information is required before the review may be completed.
Please address the items on the attached pages no later than the close of business on October 18, 2023.
Please be aware that you are responsible for meeting all requirements set forth in North Carolina
rules and regulations. Any oversights that occurred in the review of the subject application package are
still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items
in Sections A through K, or failure to provide the additional information on or before the above -requested
date may result in your application being returned as incomplete pursuant to 15A NCAC 02T .0107(e)(2).
Please reference the subject application number when providing the requested information. All
revised and/or additional documentation shall be signed, sealed, and dated (where needed), with an
electronic response submitted to my attention at: hiips://edocs.deq.nc.gov/Forms/NonDischarge-Branch-
Submittal-Form-Ver2.
If you have any questions regarding this request, please contact me at (919) 707-3655 or
cord.anthony(kdeq.nc.gov. Thank you for your cooperation.
DOCUSigned by:
Sincerely, Cad �Cn
2D03237162FA4E5_
Cord Anthony, Engineer II
Division of Water Resources
cc: Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy)
John R. Harman, PE — Professional Consulting Engineer (Electronic Copy)
Laserfiche File (Electronic Copy)
D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources
512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617
NORTH CAROLINA
n^w�e^e a 1.. ^^�� n^^�� 919.707.9000
Mr. James Scott Jones
September 18, 2023
Page 2 of 4
A. Cover Letter:
1. No comments.
B. Application Fee:
1. No comments.
C. Application (Form: SFRWWIS 06-16):
1. Sections VA and V.18 of Form: SFRWWIS 06-16 have not been filled out. Please ensure that all
relevant forms have been filled in.
2. Per 15A NCAC 02T .0106(b), a permit application shall be signed by a principle executive officer
of at least the level of vice president, or their authorized representative. According to the Secretary
of State website, James Scott Jones is a managing member of Princess Holdings, LLC. The
application, however, lists Steve Jones as the signature authority and the application has been
signed by Scott Jones. Are these individuals or are all the above names referring to James Scott
Jones?
D. Property Ownership Documentation:
1. According to the most current version of the Wake County GIS, parcels have not been subdivided
for individual housing lots. Also of note is the fact that setback waivers for specific lots have already
been recorded with the register of deeds. Generally, this would require specific parcel numbers to
occur. Have individual parcel numbers been issued for each lot? Please note that, if parcel numbers
have not been issued for each lot, this permit will be issued for construction only.
E. Soil Evaluation:
According to the soil evaluation, the site consists of Creedmoor/Green Level complex with
expansive clays overlain by suitable soils. Despite the proximity to a confining soil layer, a 13%
drainage coefficient is being proposed. How is runoff at the toe of the irrigation area to be prevented
and how has this coefficient been determined? Additionally, there is a large variance in drainage
coefficient between this site and surrounding lots despite very close proximity and similar soil
types. Please explain the reasoning for this variance.
2. Per 15A NCAC 02T .0604(b)(2), Ksat values are to be based upon the most restrictive horizon.
The soils report, however, states that the Ksat has been measured in the "least restrictive horizon".
Please clarify and or update the soils report.
3. No soil delineated map has been included. Per 15A NCAC 02T .0604(b)(3), a soil delineated map
shall be included within the soil evaluation. Please provide this documentation.
4. Application form SFRWWIS 06-16 requires all soil boring logs to be provided within the soil
evaluation. Please provide the soil boring logs for each boring that was performed.
Mr. James Scott Jones
September 18, 2023
Page 3 of 4
5. According to the summary table for the soil borings, multiple measurements of the seasonal high-
water table were found to be less than 18" from the ground surface and no mention of a perched
water table was made. Per 15A NCAC 02T .0605(p), a minimum of 18" of vertical separation shall
be provided. Please explain how this separation distance will be maintained and document any
required fill within the plans and soils report.
F. Engineering Plans:
On page 4 of the engineering plan set, the "Section Thru EZ Treat Pod" detail lists it as a Model
1200 EZ-Treat system. Please update this to reflect the currently designed Model 600 EZ-Treat
system.
Additionally, the return line diameter on page 4 of the engineering plans does not match those
found on page 3 of the engineering plans. The field plan also does not seem to call out the 4" service
line from the facility. Please correct any inconsistencies.
2. Per Form: SFRWWIS 06-16, engineering plans shall include the locations within the irrigation
system of air releases, drains, control valves, and the highest irrigation nozzle/emitter. Please
update the proposed engineering plans to include these details.
G. Specifications:
1. No comments.
H. Engineering Calculations:
1. No comments.
I. Site Map:
1. Per 15A NCAC 02T .0604(d)(2), a delineation of the review and compliance boundaries shall be
provided. The compliance and review boundaries have not been drawn on the site map. Please
update the site map to include these boundaries.
J. Operation & Maintenance Plan:
1. No Operation & Maintenance Plan has been provided. Please provide an Operation & Maintenance
Plan pursuant to 15A NCAC 02T .0604(f).
K. Additional Documentation:
➢ County Health Department Denial Letter:
1. No comments.
➢ Existing Permit:
1. Not applicable.
Mr. James Scott Jones
September 18, 2023
Page 4 of 4
➢ Floodway Regulation Compliance:
1. The geography of the area of development is complex. It is difficult to discern the proximity
of fields and other structures to the 100-year floodplain. Please provide an overlay of the
floodplain to ensure that no infringement is occurring.
➢ Operational Agreements:
Per 15A NCAC 02T .0604(h), a notarized Operation and Maintenance Agreement shall be
provided. The Operation and Maintenance Agreement provided, however, was recorded on a
previous version of our form. Please provide a copy of the agreement on the newest form
version with an up-to-date permit number.
➢ Threatened or Endangered Aquatic Species Documentation:
1. According to the NC Department of Natural and Cultural Resources report, an endangered
species has been identified in the area. Please contact the U.S. Fish and Wildlife Service for
further guidance.