HomeMy WebLinkAboutWQ0003468_More Information (Requested)_20231108ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director D. J. RUSSELL — GENERAL MANAGER WEST FRASER, INC. 361 FEDERAL ROAD RIEGELWOOD, NORTH CAROLINA 28456 Dear Mr. Russell: NORTH CAROLINA Environmental Quality November 8, 2023 Subject: Application No. WQ0003468 Additional Information Request #2 Armour Lumber Mill CLRS Closed -Loop Recycle System Columbus County Division of Water Resources' Central and Regional staff has reviewed the application package received on June 6, 2023, and subsequent additional information received on August 24, 2023. However, additional information is required before the review may be completed. Please address the items on the attached pages no later than the close of business on December 8. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items in Sections A through B, or failure to provide the additional information on or before the above -requested date may result in your application being returned as incomplete pursuant to 15A NCAC 02T .0107(e)(2). Please reference the subject application number when providing the requested information. All revised and/or additional documentation shall be signed, sealed, and dated (where needed), with an electronic response submitted to my attention at: https://edocs.deq.nc.gov/Forms/NonDischarfze-Branch- Submittal-Form-Ver2. If you have any questions regarding this request, please contact me at (919) 707-3656 or leah.parente@deq.nc.gov. Thank you for your cooperation. Sincerely, �, /ff 'PAC. Leah H. Parente, Geologist/Hydrogeologist Division of Water Resources cc: Wilmington Regional Office, Water Quality Regional Operations Section (Electronic Copy) Laserfiche File (Electronic Copy) D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROLINA oepammem of eammamemai uuahty /`� 919.707.9000 Mr. Russell November 8, 2023 Page 2 of 2 A. Cover Letter: 1. Per the submitted cover letter, two of the minor modifications already performed at the facility are described as the removal of the centrifuge system and the addition of a new oil/water separator. Please confirm that the centrifuge system was replaced by the new oil/water separator. If the centrifuge system was replaced by the new oil/water separator, please provide an attestation verifying the new oil removal system is equal to or more efficient than the previous centrifuge system. 2. Per the submitted cover letter, the recirculation pump is being replaced as part of the minor modification. The operating rate of the previous recirculation pump was listed as 500 gallons per minute (GPM). Based on the performance curve submitted in the current application, the new Model T3A60S-B Self -Priming Centrifugal Pump cannot operate at a rate of 500 GPM. Please provide the correct rate at which the new pump will be operating and plot this point on the performance curve. Per the submitted cover letter, modifications to the Ash Pond 2 outlet pipe have been made. However, it is unclear what modifications were made. It appears that a rip rap pad for erosion control was added which involved excavation into the clay liner. This excavation could potentially compromise the clay liner integrity. Please provide a thorough explanation of the modifications made to the outlet pipe and comment on the clay liner integrity. B. Attachment B — Signature Authority Delegation: A signature authority designation letter was submitted as a part of the response to the Additional Information Request dated August 9, 2023. The person who signed this letter, Paul Jenkins, does not have the authority to designate D. J. Russell as a signature authority for this facility. Please resubmit the designation letter signed by a principal executive officer of at least the level of Vice President pursuant to 15A NCAC 02T .0106(c) authorizing Mr. Russell to sign this application, or resubmit the application signed by a signature authority for this facility. A blank designation letter template is attached to this letter.