HomeMy WebLinkAboutNCG020330_2023 DMR_20240119 (3) • %% eurofins Environment Testing ANALYTICAL REPORT PREPARED FOR Attn: Daniel Christman 3M Company 4191 Hwy 87 South Moncure, North Carolina 27559 Generated 12/14/2023 2:53:07 PM JOB DESCRIPTION 3M WMS - SW Inorganics Pittsboro NC JOB NUMBER 410-152202-1 Eurofins Lancaster Laboratories Environment Testing, LLC 2425 New Holland Pike Lancaster PA 17601 Page 1 of 16 ��`� EOL See page two for job notes and contact information. g o 111 Eurofins Lancaster Laboratories Environment Testing, LLC Job Notes This report may not be reproduced except in full, and with written approval from the laboratory. The results relate only to the samples tested. For questions please contact the Project Manager at the e-mail address or telephone number listed on this page. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 17025) unless otherwise noted under the individual analysis. Authorization Generated 12/14/2023 2:53:07 PM Authorized for release by Nicole Brown,Project Manager Nicole.Brown@et.eurofinsus.com (717)471-3265 Eurofins Lancaster Laboratories is a laboratory within Eurofins Lancaster Laboratories Environment Testing, LLC,a company within Eurofins Environment Testing Group of Companies Page 2 of 16 12/14/2023 Eurofins Lancaster Laboratories Environment Testing, LLC Compliance Statement Analytical test results meet all requirements of the associated regulatory program (e.g., NELAC (TNI), DoD, and ISO 17025) unless otherwise noted under the individual analysis. Data qualifiers are applied to note exceptions. Noncompliant quality control (QC) is further explained in narrative comments. • QC results that exceed the upper limits and are associated with non-detect samples are qualified but further narration is not required since the bias is high and does not change a non-detect result. Further narration is also not required with QC blank detection when the associated sample concentration is non-detect or more than ten times the level in the blank. Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD is performed, unless otherwise specified in the method. Surrogate and/or isotope dilution analyte recoveries (if applicable)which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in the narrative. Regulated compliance samples (e.g. SDWA, NPDES) must comply with the associated agency requirements/permits. Measurement uncertainty values, as applicable, are available upon request. Test results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. Times are local to the area of activity. Parameters listed in the 40 CFR Part 136 Table II as "analyze immediately" and tested in the laboratory are not performed within 15 minutes of collection. This report shall not be reproduced except in full, without the written approval of the laboratory. WARRANTY AND LIMITS OF LIABILITY- In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. The foregoing express warranty is exclusive and is given in lieu of all other warranties, expressed or implied, except as otherwise agreed. We disclaim any other warranties, expressed or implied, including a warranty of fitness for particular purpose and warranty of merchantability. In no event shall Eurofins Lancaster Laboratories Environmental, LLC be liable for indirect, special, consequential, or incidental damages including, but not limited to, damages for loss of profit or goodwill regardless of(A)the negligence (either sole or concurrent) of Eurofins Lancaster Laboratories Environmental and (B)whether Eurofins Lancaster Laboratories Environmental has been informed of the possibility of such damages. We accept no legal responsibility for the purposes for which the client uses the test results. Except as otherwise agreed, no purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client. 77( Page 3 of 16 12/14/2023 Client: 3M Company Laboratory Job ID:410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Table of Contents U Cover Page 1 Table of Contents 4 Definitions/Glossary 5 Case Narrative 6 Detection Summary 7 Client Sample Results 8 QC Sample Results 9 QC Association Summary 10 Lab Chronicle 11 Certification Summary 12 Method Summary 13 Sample Summary 14 Chain of Custody 15 Receipt Checklists 16 Eurofins Lancaster Laboratories Environment Testing LLC Page 4 of 16 12/14/2023 Definitions/Glossary Client:3M Company Job ID: 410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Qualifiers General Chemistry Qualifier Qualifier Description J Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value. Glossary Abbreviation These commonly used abbreviations may or may not be present in this report. c Listed under the"D"column to designate that the result is reported on a dry weight basis %R Percent Recovery CFL Contains Free Liquid CFU Colony Forming Unit CNF Contains No Free Liquid DER Duplicate Error Ratio(normalized absolute difference) Dil Fac Dilution Factor DL Detection Limit(DoD/DOE) DL,RA,RE,IN Indicates a Dilution,Re-analysis,Re-extraction,or additional Initial metals/anion analysis of the sample DLC Decision Level Concentration(Radiochemistry) EDL Estimated Detection Limit(Dioxin) LOD Limit of Detection(DoD/DOE) LOQ Limit of Quantitation(DoD/DOE) MCL EPA recommended"Maximum Contaminant Level" MDA Minimum Detectable Activity(Radiochemistry) MDC Minimum Detectable Concentration(Radiochemistry) MDL Method Detection Limit ML Minimum Level(Dioxin) MPN Most Probable Number MQL Method Quantitation Limit NC Not Calculated ND Not Detected at the reporting limit(or MDL or EDL if shown) NEG Negative/Absent POS Positive/Present PQL Practical Quantitation Limit PRES Presumptive QC Quality Control RER Relative Error Ratio(Radiochemistry) RL Reporting Limit or Requested Limit(Radiochemistry) RPD Relative Percent Difference,a measure of the relative difference between two points TEF Toxicity Equivalent Factor(Dioxin) TEQ Toxicity Equivalent Quotient(Dioxin) TNTC Too Numerous To Count Eurofins Lancaster Laboratories Environment Testing, LLC Page 5 of 16 12/14/2023 Case Narrative Client: 3M Company Job ID:410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Job ID: 410-152202-1 Laboratory: Eurofins Lancaster Laboratories Environment Testing,LLC 4 Narrative Job Narrative 410-152202-1 Analytical test results meet all requirements of the associated regulatory program listed on the Accreditation/Certification Summary Page unless otherwise noted under the individual analysis. Data qualifiers are applied to indicate exceptions. Noncompliant quality control (QC)is further explained in narrative comments. Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations,to demonstrate precision and accuracy at a batch level,a LCS/LCSD may be performed,unless otherwise specified in the method. Surrogate and/or isotope dilution analyte recoveries(if applicable)which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in the narrative. Regulated compliance samples(e.g.SDWA, NPDES)must comply with the associated agency requirements/permits. Receipt The samples were received on 11/22/2023 10:12 AM. Unless otherwise noted below,the samples arrived in good condition,and,where required,properly preserved and on ice. The temperatures of the 3 coolers at receipt time were 0.3°C, 1.8°C and 3.3°C Receipt Exceptions The Field Sampler was not listed on the Chain of Custody.The client responded that the field sampler was Faelan Hoese. The following sample was listed on the Chain of Custody(COC);however, no sample was received:OF-002(410-152202-2). Samples start with"OF",not"3M"as listed on the COC.The client was contacted and provided instructions to login the samples with the prefix"OF-". General Chemistry No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. Eurofins Lancaster Laboratories Environment Testing, LLC Page 6 of 16 12/14/2023 Detection Summary Client: 3M Company Job ID: 410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Client Sample ID: OF-001 Lab Sample ID: 410-152202-1 Analyte Result Qualifier RL MDL Unit Dil Fac D Method Prep Type Total Suspended Solids 2.9 J 3.0 1.0 mg/L 1 2540D-2011 Total/NA Total Organic Carbon 6.0 1.0 0.50 mg/L 1 5310C-2011 Total/NA Client Sample ID: OF-005 Lab Sample ID: 410-152202-3 El Analyte Result Qualifier RL MDL Unit Dil Fac D Method Prep Type Total Suspended Solids 37 7.5 2.5 mg/L 1 2540D-2011 Total/NA Total Organic Carbon 6.3 1.0 0.50 mg/L 1 5310C-2011 Total/NA Client Sample ID: OF-008 Lab Sample ID: 410-152202-4 Analyte Result Qualifier RL MDL Unit Dil Fac D Method Prep Type Total Suspended Solids 3.1 3.0 1.0 mg/L 1 2540D-2011 Total/NA Total Organic Carbon 7.1 1.0 0.50 mg/L 1 5310C-2011 Total/NA Client Sample ID: OF-006 Lab Sample ID: 410-152202-5 Analyte Result Qualifier RL MDL Unit Dil Fac D Method Prep Type Total Suspended Solids 19 5.5 1.8 mg/L 1 2540D-2011 Total/NA Total Organic Carbon 2.9 1.0 0.50 mg/L 1 5310C-2011 Total/NA This Detection Summary does not include radiochemical test results. Eurofins Lancaster Laboratories Environment Testing, LLC Page 7 of 16 12/14/2023 Client Sample Results Client: 3M Company Job ID:410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Client Sample ID: OF-001 Lab Sample ID: 410-152202-1 Date Collected: 11/21/23 11:40 Matrix: Stormwater Date Received: 11/22/23 10:12 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM(Oil&Grease)(1664B) ND 5.3 1.5 mg/L 12/12/23 19:36 1 Total Suspended Solids(SM 2.9 J 3.0 1.0 mg/L 11/28/23 12:10 1 6 2540D-2011) Total Organic Carbon(SM 6.0 1.0 0.50 mg/L 12/14/23 03:06 1 5310C-2011) Client Sample ID: OF-005 Lab Sample ID: 410-152202-3 Date Collected: 11/21/23 11:55 Matrix: Stormwater Date Received: 11/22/23 10:12 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM(Oil&Grease)(1664B) ND 5.2 1.5 mg/L 12/12/23 19:36 1 Total Suspended Solids(SM 37 7.5 2.5 mg/L 11/28/23 12:10 1 2540D-2011) Total Organic Carbon(SM 6.3 1.0 0.50 mg/L 12/14/23 03:50 1 5310C-2011) Client Sample ID: OF-008 Lab Sample ID: 410-152202-4 Date Collected: 11/21/23 12:00 Matrix: Stormwater Date Received: 11/22/23 10:12 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM(Oil&Grease)(1664B) ND 5.3 1.5 mg/L 12/12/23 19:36 1 Total Suspended Solids(SM 3.1 3.0 1.0 mg/L 11/28/23 12:10 1 2540D-2011) Total Organic Carbon(SM 7.1 1.0 0.50 mg/L 12/14/23 04:05 1 5310C-2011) Client Sample ID: OF-006 Lab Sample ID: 410-152202-5 Date Collected: 11/21/23 15:00 Matrix: Stormwater Date Received: 11/22/23 10:12 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM(Oil&Grease)(1664B) ND 5.6 1.6 mg/L 12/12/23 19:36 1 Total Suspended Solids(SM 19 5.5 1.8 mg/L 11/28/23 12:10 1 2540D-2011) Total Organic Carbon(SM 2.9 1.0 0.50 mg/L 12/14/23 05:16 1 5310C-2011) Eurofins Lancaster Laboratories Environment Testing, LLC Page 8 of 16 12/14/2023 QC Sample Results Client: 3M Company Job ID:410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Method: 1664B - HEM and SGT-HEM Lab Sample ID: MB 410-453196/1 Client Sample ID: Method Blank Matrix:Water Prep Type:Total/NA Analysis Batch:453196 MB MB Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM(Oil&Grease) ND 5.0 1.4 mg/L 12/12/23 19:36 1 Lab Sample ID: LCS 410-453196/2 Client Sample ID: Lab Control Sample U Matrix:Water Prep Type:Total/NA Analysis Batch:453196 Spike LCS LCS %Rec Analyte Added Result Qualifier Unit D %Rec Limits HEM(Oil&Grease) 40.0 31.6 mg/L 79 78.114 Lab Sample ID: LCSD 410-453196/3 Client Sample ID: Lab Control Sample Dup Matrix:Water Prep Type: Total/NA Analysis Batch:453196 Spike LCSD LCSD %Rec RPD Analyte Added Result Qualifier Unit D %Rec Limits RPD Limit HEM(Oil&Grease) 40.0 33.3 mg/L 83 78-114 5 13 Method: 2540D-2011 -Solids, Total Suspended (TSS) Lab Sample ID: MB 410-447531/1 Client Sample ID: Method Blank Matrix:Water Prep Type:Total/NA Analysis Batch:447531 MB MB Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Total Suspended Solids ND 3.0 1.0 mg/L 11/28/23 12:10 1 Lab Sample ID: LCS 410-447531/2 Client Sample ID: Lab Control Sample Matrix:Water Prep Type:Total/NA Analysis Batch:447531 Spike LCS LCS %Rec Analyte Added Result Qualifier Unit D %Rec Limits Total Suspended Solids 150 147 mg/L 98 89.105 Method: 5310C-2011 -Total Organic Carbon/Persulfate - Ultrav Lab Sample ID: MB 410-454076/36 Client Sample ID: Method Blank Matrix:Water Prep Type:Total/NA Analysis Batch:454076 MB MB Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Total Organic Carbon ND 1.0 0.50 mg/L 12/14/23 00:14 1 Lab Sample ID: LCS 410-454076/35 Client Sample ID: Lab Control Sample Matrix:Water Prep Type:Total/NA Analysis Batch:454076 Spike LCS LCS %Rec Analyte Added Result Qualifier Unit D %Rec Limits Total Organic Carbon 25.0 25.5 mg/L 102 91-113 Eurofins Lancaster Laboratories Environment Testing, LLC Page 9 of 16 12/14/2023 QC Association Summary Client: 3M Company Job ID: 410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC General Chemistry Analysis Batch: 447531 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 410-152202-1 OF-001 Total/NA Stormwater 2540D-2011 410-152202-3 OF-005 Total/NA Stormwater 2540D-2011 410-152202-4 OF-008 Total/NA Stormwater 2540D-2011 410-152202-5 OF-006 Total/NA Stormwater 2540D-2011 MB 410-447531/1 Method Blank Total/NA Water 2540D-2011 LCS 410-447531/2 Lab Control Sample Total/NA Water 2540D-2011 Analysis Batch: 453196 8 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 410-152202-1 OF-001 Total/NA Stormwater 1664B 410-152202-3 OF-005 Total/NA Stormwater 1664B 410-152202-4 OF-008 Total/NA Stormwater 1664B 410-152202-5 OF-006 Total/NA Stormwater 1664B MB 410-453196/1 Method Blank Total/NA Water 1664B LCS 410-453196/2 Lab Control Sample Total/NA Water 1664B LCSD 410-453196/3 Lab Control Sample Dup Total/NA Water 1664B Analysis Batch:454076 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 410-152202-1 OF-001 Total/NA Stormwater 5310C-2011 410-152202-3 OF-005 Total/NA Stormwater 5310C-2011 410-152202-4 OF-008 Total/NA Stormwater 5310C-2011 410-152202-5 OF-006 Total/NA Stormwater 5310C-2011 MB 410-454076/36 Method Blank Total/NA Water 5310C-2011 LCS 410-454076/35 Lab Control Sample Total/NA Water 5310C-2011 Eurofins Lancaster Laboratories Environment Testing, LLC Page 10 of 16 12/14/2023 Lab Chronicle Client: 3M Company Job ID: 410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Client Sample ID: OF-001 Lab Sample ID: 410-152202-1 Date Collected: 11/21/23 11:40 Matrix: Stormwater Date Received: 11/22/23 10:12 Batch Batch Dilution Batch Prepared Prep Type Type Method Run Factor Number Analyst Lab or Analyzed Total/NA Analysis 1664B 1 453196 QT6L ELLE 12/12/23 19:36 Total/NA Analysis 2540D-2011 1 447531 M98K ELLE 11/28/23 12:10-11/29/23 07:10' Total/NA Analysis 5310C-2011 1 454076 P684 ELLE 12/14/23 03:06 Client Sample ID: OF-005 Lab Sample ID: 410-152202-3 Date Collected: 11/21/23 11:55 Matrix: Stormwater Date Received: 11/22/23 10:12 Batch Batch Dilution Batch Prepared Prep Type Type Method Run Factor Number Analyst Lab or Analyzed 1" Total/NA Analysis 1664B 1 453196 QT6L ELLE 12/12/23 19:36 Total/NA Analysis 2540D-2011 1 447531 M98K ELLE 11/28/23 12:10-11/29/23 07:10' Total/NA Analysis 5310C-2011 1 454076 P684 ELLE 12/14/23 03:50 Client Sample ID: OF-008 Lab Sample ID: 410-152202-4 Date Collected: 11/21/23 12:00 Matrix: Stormwater Date Received: 11/22/23 10:12 Batch Batch Dilution Batch Prepared Prep Type Type Method Run Factor Number Analyst Lab or Analyzed Total/NA Analysis 1664E 1 453196 QT6L ELLE 12/12/23 19:36 Total/NA Analysis 2540D-2011 1 447531 M98K ELLE 11/28/23 12:10-11/29/23 07:10' Total/NA Analysis 5310C-2011 1 454076 P684 ELLE 12/14/23 04:05 Client Sample ID: OF-006 Lab Sample ID: 410-152202-5 Date Collected: 11/21/23 15:00 Matrix: Stormwater Date Received: 11/22/23 10:12 Batch Batch Dilution Batch Prepared Prep Type Type Method Run Factor Number Analyst Lab or Analyzed Total/NA Analysis 1664B 1 453196 QT6L ELLE 12/12/23 19:36 Total/NA Analysis 2540D-2011 1 447531 M98K ELLE 11/28/23 12:10-11/29/23 07:10' Total/NA Analysis 5310C-2011 1 454076 P684 ELLE 12/14/23 05:16 'This procedure uses a method stipulated length of time for the process. Both start and end times are displayed. Laboratory References: ELLE=Eurofins Lancaster Laboratories Environment Testing,LLC,2425 New Holland Pike,Lancaster,PA 17601,TEL(717)656-2300 Eurofins Lancaster Laboratories Environment Testing, LLC Page 11 of 16 12/14/2023 Accreditation/Certification Summary Client: 3M Company Job ID:410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Laboratory: Eurofins Lancaster Laboratories Environment Testing, LLC Unless otherwise noted,all analytes for this laboratory were covered under each accreditation/certification below. Authority Program Identification Number Expiration Date North Carolina(WW/SW) State 521 12-31-23 The following analytes are included in this report,but the laboratory is not certified by the governing authority. This list may include analytes for which the agency does not offer certification. Analysis Method Prep Method Matrix Analyte 2540D-2011 Stormwater Total Suspended Solids 10 Eurofins Lancaster Laboratories Environment Testing, LLC Page 12 of 16 12/14/2023 Method Summary Client: 3M Company Job ID:410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Method Method Description Protocol Laboratory 1664B HEM and SGT-HEM 1664B ELLE 2540D-2011 Solids,Total Suspended(TSS) SM ELLE 5310C-2011 Total Organic Carbon/Persulfate-Ultrav SM ELLE Protocol References: 1664B=EPA-821-98-002 SM="Standard Methods For The Examination Of Water And Wastewater" Laboratory References: ELLE=Eurofins Lancaster Laboratories Environment Testing,LLC,2425 New Holland Pike,Lancaster,PA 17601,TEL(717)656-2300 a Eurofins Lancaster Laboratories Environment Testing, LLC Page 13 of 16 12/14/2023 Sample Summary Client: 3M Company Job ID:410-152202-1 Project/Site: 3M WMS-SW Inorganics Pittsboro NC Lab Sample ID Client Sample ID Matrix Collected Received 410-152202-1 OF-001 Stormwater 11/21/23 11:40 11/22/23 10:12 410-152202-3 OF-005 Stormwater 11/21/23 11:55 11/22/23 10:12 410-152202-4 OF-008 Stormwater 11/21/23 12:00 11/22/23 10:12 410-152202-5 OF-006 Stormwater 11/21/23 15:00 11/22/23 10:12 EE Eurofins Lancaster Laboratories Environment Testing, LLC Page 14 of 16 12/14/2023 vironme Chain of Custody Record ti:=eurofins 1 Environment Testing 410-152202 Chain of Custody Isarrn'er Lab PM Carrier Tracking No(s) COO No Brown.Nicole 410 101661.29021 1 Prone E-Mail State of Ongm Page Daniel Christman Nicole Brown@et eurofinsus corn Page 1 of 1 Company PWS'.D Job p 3M Company Analysis Requested Address Due Date Requested. ' Preservation Codes: 4191 Hwy 87 South M Hexane City TAT Requested(days): 8-NaOH N•None Moncure 0-AsNaO2 m C-Zn Acetate p-Na204S State,Zip .N- D-Nitric And D.Na2903 NC,27559 Compliance Project: A Yes A No v E•NaH504 R-Na2S203 Phone PO e P-McOH hlor S S.H2504 919.642-4010(Tel) Purchase Order Requested El a H-Abic -Ascorbic Acid T-TSP Dodecahydrate Email WO a Z m I-Ice U-Acetone `pp w J-DI Water V V.MCAA dchristman@mmm corn .e Z o e `m K-EDTA W-PH 45 Project Name Project x } w Wm I. EDA Z•other(specify) 3M MS-SW Inorganics Pittsboro NC 41017322 m 0 ' v ` Site SSOW# a O 0 y a ID Other, y i ZC C CI a w ❑ O m` Matrix = coSamPle m E Type (W....br. LL E z, rni Z Sample (C=com n p, o•W..du a - Sample Identification Sample Date Time G=grab) ei•iv.u..A•Air C N' 9 iC S F° Special Instructions/Note: Preservation Code A N >( — — ------ �.✓lll Ud t I1Iz1(7-3 l l'i-Le (� Water ., - X Al 0 } (7-;7c) (.y Water Y sk lix Ail C165- ll-$S t.. Water X s. M Cog 1.: \y.Qb ( Water `f 1/41 y. Ela 3-tit OV 6 - -- V 3=te a (7 , X Y X _ Possible Hazard Identification Sample Disposal(A fee may be assessed if samples are retained longer than 1 month) CI 0 Non-Hazard O Flammable C�1 Skin Irritant Poison B Unknown Radiological 0 Return To Client O Disposal By Lab U Archive For Months Deliverable Requested I,II.III,IV,Other(specify) Special Instructions/OC Requirements Empty Kit Relinquished by !Date ITlme t`Method of Shipment Relinquished by Date/Time Company Received by Date/Time Company per— ‘(t2i I23 - 7. CD .0 Relinquished by Date/Time Company Received by + ." batenime Company --. • Relinquished by Dare/ ima Company Received by ^ �f)���' Dateire �3 2/„ pa y Cus��gc�dyy Seals Intact Custody Seal No c Cooler Temperature(s)°C and Other RReemJarrkss • ;• .1.Yes A No 14S 2- 1 l 1c -2 :�""/3i Qr3 9./ 2.,90.� Ver 0610tl;2(121 - ^ Page 15 of 16 12/14/2 Login Sample Receipt Checklist Client:3M Company Job Number:410-152202-1 Login Number: 152202 List Source:Eurofins Lancaster Laboratories Environment Testing,LLC List Number: 1 Creator:McCaskey,Jonathan Question Answer Comment The cooler's custody seal is intact. True The cooler or samples do not appear to have been compromised or True tampered with. Samples were received on ice. True Cooler Temperature acceptable,where thermal pres is required(</=6C,not True frozen). Cooler Temperature is recorded. True WV:Container Temp acceptable,where thermal pres is required(</=6C,not N/A frozen). WV: Container Temperature is recorded. N/A COC is present. True COC is filled out in ink and legible. True COC is filled out with all pertinent information. True There are no discrepancies between the containers received and the COC. False Refer to Job Narrative for details. Sample containers have legible labels. True 14 Containers are not broken or leaking. True Sample collection date/times are provided. True Appropriate sample containers are used. True Sample bottles are completely filled. True There is sufficient vol.for all requested analyses. True Is the Field Sampler's name present on COC? False Refer to Job Narrative for details. Sample custody seals are intact. N/A VOA sample vials do not have headspace>6mm in diameter(none,if from N/A WV)? Eurofins Lancaster Laboratories Environment Testing,LLC Page 16 of 16 12/14/2023