Loading...
HomeMy WebLinkAboutWR0500150_Recovery Well Permit Application_20240118 North Carolina Department of Environmental Quality Division of Water Resources 512 North Salisbury Street 1611 Mail Service Center Raleigh, North Carolina 27699-1611 919.707.9000 January 18, 2024 Mr. Hassan Osman North Carolina Department of Environmental Quality Division of Waste Management, Underground Storage Tank Section 1646 Mail Service Center Raleigh, NC 27699-1646 Sent Via Email Subject: Recovery Well Construction Permit # WR0500150 Wicker Mart 10 (UST Incident #12607) 200 South Horner Boulevard Sanford, NC 27330 – Lee County Mr. Osman: In accordance with the application received on January 12, 2024, we are forwarding herewith Recovery Well Construction Permit No. WR0500150 dated January 18, 2024, issued for the construction of a recovery well system (installation of nine wells). Please be aware that some counties have well construction programs, and you may be required to obtain a well construction permit before installation. This Permit will be effective from the date of its issuance and shall be subject to the conditions and limitations as specified therein. Please note the addition of stipulation #3 to the permit enclosed. If you have any questions about this permit, please contact Michael Hall at (919) 791-4237 or via email at michael.hall@deq.nc.gov. Sincerely, Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Enclosure -Permit -Application Package cc: Chris Hanley, ATC Associates of North Carolina, P.C. Laserfiche DocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA North Carolina Department of Environmental Quality Division of Water Resources 512 North Salisbury Street 1611 Mail Service Center Raleigh, North Carolina 27699-1611 919.707.9000 NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES PERMIT FOR THE CONSTRUCTION OF A RECOVERY WELL In accordance with the provisions of Article 7, Chapter 87, North Carolina General Statutes, and other applicable Laws, Rules and Regulations. PERMISSION IS HEREBY GRANTED TO The North Carolina Department of Environmental Quality, State Lead Program FOR THE CONSTRUCTION OF A RECOVERY WELL owned by The North Carolina Department of Environmental Quality, State Lead Program, at mailing address 1646 Mail Service Center, Raleigh, NC 27699-1646. The wells will be located on the property owned by Patterson-Seminole Properties, LLC at 200 South Horner Boulevard (PIN 9642-69-5083-00), Sanford, NC 27330. This Permit is issued in accordance with the application received on January 14, 2024, in conformity with specifications and supporting data, all of which are filed with the Department of Environmental Quality and are considered integral parts of this Permit. This Permit is for well construction only and does not waive any provision or requirement of any other applicable law or regulation. Construction of any well under this Permit shall be in strict compliance with the North Carolina Well Construction Regulations and Standards (15A NCAC 02C .0100), and other State and Local Laws and regulations pertaining to well construction. If any requirements or limitations specified in this Permit are unacceptable, you have a right to an adjudicatory hearing upon written request within 30 days of receipt of this Permit. The request must be in the form of a written petition conforming to Chapter 150B of the North Carolina General Statutes and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, North Carolina 27699-6714. Unless such a demand is made, this Permit is final and binding. This Permit will be effective for one year from the date of its issuance and shall be subject to other specified conditions, limitations, or exceptions as follows: 1. Issuance of this Permit does not obligate reimbursement from State trust funds, if these wells are being installed as part of an investigation for contamination from an underground storage tank or dry cleaner incident. 2. Issuance of this Permit does not supersede any other agreement, permit, or requirement issued by another agency. 3. The well(s) shall be located and constructed as shown on the attachments submitted as part of the Permit application. 4. Each well shall have a Well Contractor Identification Plate in accordance with 15A NCAC 02C .0108(o). 5. Well construction records (GW-1) for each well shall be submitted to the Division of Water Quality’s Information Processing Unit within 30 days of the well completion. 6. When the well is discontinued or abandoned, it shall be abandoned in accordance with 15A NCAC 02C .0113 and a well abandonment record (GW-30) shall be submitted to the Division of Water Quality’s Information Processing Unit within 30 days of the well abandonment. 7. If the well penetrates any water-bearing zone that contains contaminated waters, the upper three feet of the well shall be grouted within one day after the casing is set or the well abandoned. 8. Discharge from this well must be treated at a NC permitted wastewater treatment facility appropriate to treat this waste. ____________________________________ Vanessa E. Manuel, Assistant Regional Supervisor Division of Water Resources By Authority of the Environmental Management Commission Permit Number: WR0500150 Permit Issued: January 18, 2024 DocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA 2725 E. Millbrook Road, Suite 121 Raleigh, North Carolina 27604 Telephone 919-871-0999 Fax 919-871-0335 www.atcgroupservices.com January 12, 2024 North Carolina Department of Environmental Quality - Division of Water Resources Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609 Re: Permit to Construct Monitoring Well Former Wicker Mart N0. 10 200 South Horner Blvd Sanford, Lee County, North Carolina NCDEQ Incident No. 12607 ATC Project No. STL1260701 Dear Sir or Madam: Enclosed please find an application for a permit to construct one Type II recovery well. The recovery well will be installed on a property (Pin# 9642-69-5083-00) located at 200 South Horner Blvd, Lee County, North Carolina. The permit application, site map with the proposed location of the monitoring well, well construction details, and other relevant informati on are enclosed as attachments. Please review this package and return the approved permit to this office. The associated recovery well is scheduled to be installed on January 31, 2024. If you have any questions or require additional information, please contact my office at (919) 649-7605. Sincerely, ATC Associates of North Carolina, P.C. Chris Hanley, P.G. Project Geologist 919-649-7605 Chris.Hanley@oneatlas.com DocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: 1/12/2024 2. County: Sanford 3. What type of well are you applying for? (monitoring or recovery): Recovery 4. Applicant: Hassan Osman (NCDEQ State Lead) Telephone: 919-707-8167 Applicant’s Mailing Address: 1646 Mail Service Center, Raleigh, NC 27699 Applicant’s Email Address (if available): Hassan.Osman@NCDENR.GOV 5. Contact Person (if different than Applicant): Chris Hanley (ATC Associates) Telephone: 919-649-7605 Contact Person’s Mailing Address: 2725 E Millbrook Rd, Ste 121, Raleigh, NC 27604 Contact Person’s Email Address (if available): Chris.Hanley@oneatlas.com 6. Property Owner (if different than Applicant): Patterson-Seminole Properties LLC Telephone: 919-353-4462 Property Owner’s Mailing Address: PO Box 1185, Broadway, NC 27505 Property Owner’s Email Address (if available): 7. Property Physical Address (Including PIN Number) 200 S. Horner Blvd (PIN# 9642-69-5083-00) City Sanford County Lee Zip Code 8. Reason for Well(s): Groundwater contamination assessment and remediation (ex: non-discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: UST (ex: non-discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). Yes, NCDEQ UST Incident # 12607 11. Type of contaminants being monitored or recovered: Petroleum (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? Yes, 11 Existing Monitoring or Recovery Well Construction Permit No(s).: None 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): 15 feet 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? No If yes, give distance(s): NA 15. Well Contractor: SAEDACCO, Inc Certification No.: 4439 Well Contractor Address: 9088 Northfield Dr, Fort Mill, SC 29707 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse DocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated material: 1 3. Number of wells to be constructed in bedrock: 0 4. Total Number of wells to be constructed: 1 (add answers from 2 and 3) 5. How will the well(s) be secured? Locked metal flush-grade cover. 6. Estimated beginning construction date: 1/31/2024 7. Estimated construction completion date: 1/31/2024 ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant assumes total responsibility for ensuring that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. Project Geologist Signature of Applicant or *Agent Title of Applicant or *Agent Chris Hanley (ATC Associates) * If signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the Applicant, the property owner hereby consents to allow the Applicant to construct well(s) as outlined in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to ensure that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. See attached signed access agreement. Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources’ Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 GW-22M/R (Rev. 5-26-2022) DocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA 10 SCALE: 1" = 30' 0 20 30 N WICK E R S T R E E T (N.C . H W Y . 4 2 ) H O R N E R B O U L E V A R D G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S S S S S S S S S S S S S MW-10 MW-7 MW-11 MW-6 MW-1 MW-2 MW-3 MW-8 MW-4 MW-5 MW-9 F O R M E R U S T T 1 FORMER DISPENSER ISLAND F O R M E R U S T T 2 F O R M E R U S T T 3 FORMER DISPENSER ISLAND COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL SITE LEGEND: SITE PROPERTY LINE NOTE: ALL LOCATIONS ARE APPROXIMATE PARCEL LINE MW-3 TYPE III MONITORING WELL Well Identification G G GAS LINE SS SANITARY SEWER W W WATER LINE MW-9 DESTROYED MONITORING WELL Well Identification 100 BENZENE ISOCONCENTRAION CONTOUR (DASHED WHERE INFERRED) (µg/L) MW-2 7,320 MONITORING WELL Well Identification Benzene Concentration (µg/L) 219 7,320 1.99NS 2,940 <1.00 <1.00 <1.00 <1.00 <1.00 5, 0 0 0 1 , 0 0 0 1 10 10 0 Figure: Dr a w i n g F i l e : Pr o j e c t N u m b e r : Ck d . B y : Dr n . B y : Ap p ' d B y : Ck d . D a t e : Scale: Date: H: \ 2 0 2 2 \ 1 O T H E R O F F I C E S \ N O R T H C A R O L I N A \ N C D E Q - S T A T E L E A D \ W I C K E R M A R T \ S L C 1 2 6 0 7 0 1 - B E N Z . D W G , FI G 4 DI S S O L V E D B E N Z E N E IS O C O N C E N T R A T I O N C O N T O U R M A P 06/02/2022 SE E L O W E R L E F T WI C K E R M A R T N O . 1 0 - I N C I D E N T # 1 2 6 0 7 20 0 S O U T H H O R N E R B O U L E V A R D SA N F O R D , N O R T H C A R O L I N A SL C 1 2 6 0 7 0 1 AS SHOWN DH AW 4 NO T E S : 1. Fe a t u r e s s h o w n a r e n o t a n a u t h o r i t a t i v e l o c a t i o n , n o r a r e t h e y p r e s e n t e d to a s t a t e d a c c u r a c y . 2. Gr o u n d w a t e r s a m p l e s c o l l e c t e d M a y 1 1 , 2 0 2 2 . 3. Gr o u n d w a t e r r e s u l t s m e a s u r e d i n m i c r o g r a m s p e r l i t e r ( µg / L ) . 4. Ty p e I I I w e l l M W - 3 n o t u s e d t o c o n s t r u c t c o n t o u r s . 5. NS = N o t S a m p l e d . CO O R D I N A T E S Y S T E M : NA D 1 9 8 3 N O R T H C A R O L I N A S T A T E P L A N E F I P S 3 2 0 0 , U S S U R V E Y F E E T Proposed Recovery Well (RW-1) DocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA DocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA DocuSign Envelope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ocuSign Envelope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ocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA MONITORING WELL CONSTRUCTION DETAILS FLUSH GRADE MANHOLE CROSS SECTIONAL VIEW (NOT TO SCALE) LOCKABLE WELL CAP PROTECTIVE CASING AND CONCRETE PAD L1 CASING MATERIAL sch 40 PVC CASING DIAMETER 8 inches CASING LENGTH 12 inches PAD DIMENSIONS 2 feet x 2 feet HEIGHT ABOVE GROUND Flush Grade WELL CASING MATERIAL sch 40 PVC DIAMETER 4 inches JOINT TYPE flush threaded LENGTH 5 feet L2 BACKFILL AROUND CASING MATERIAL cement grout THICKNESS 3 feet SEAL TYPE OF SEAL bentonite L4 THICKNESS 1 feet FILTER PACK TYPE OF FILTER #2 silica sand DISTANCE ABOVE SCREEN 1 feet WELL SCREEN L3 SCREEN MATERIAL sch 40 PVC DIAMETER 4 inches LENGTH 15 feet SLOT SIZE 0.010 inches DEPTH TO BOTTOM OF MONITORING WELL 20 feet DEPTH TO BOTTOM OF BOREHOLE 20 feet L1 =0 FT. L2 =5 FT.DIAMETER OF BOREHOLE 12 inches L3 =15 FT. L4 =20 FT. TITLE Recovery Well Wicker Mart No. 10 200 South Horner Blvd, 2725 East Millbrook Road, Suite 121 Sanford, Lee County Raleigh, North Carolina 27604 North Carolina FILE PREP. BY REV. BY DATE PROJECT NO. CH 1/12/2024 STL1260701 DocuSign Envelope ID: 3D92E36A-7C13-4030-9BE0-EA18C71F27DA