Loading...
HomeMy WebLinkAboutSW6231204_Supplement-EZ Form_20240117 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Faircloth Gas Station 2 Project Area(ac) 64.7 ''r 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 1 5 Is this project High or Low Density? Low 6 Does this project use an off site SCM? No COMPLIANCE WITH 02H 1003(4) M1 R 7 Width of vegetated setbacks provided(feet) n/a ` 8 Will the vegetated setback remain vegetated? N/A 9 'If BUA is proposed in the setback, does it meet NCAC 02H 1003(4)(c-d)? N/A ( 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs t 11 Infiltration System 12 ,Bioretention Cell i 13 ;Wet Pond t 14 Stormwater Wetland 15 ';Permeable Pavement ent ' 16 ;Sand Filter _4 17 Rainwater Harvesting(RWH) i ° 18 Green Roof • 19 Level Spreader-Filter Strip(LS-FS) I i 20 Disconnected Impervious ervious Surface(DIS)DIS , f 21 Treatment Swale 22 ;Dry Pond 1 23 StormFilter , 24 Silva Cell 1 25 .Bayfilter 1. 26 Filterra FORMS LOADED d DESIGNER CERTIFICATION pas 1 , 27 Name and Title: C. Scott Brown,PE 28 !Organization: 4D Site Solutions, Inc. 29 Street address: 409 Chicago Drive-Ste 112 30 ;City,State,Zip: Fayetteville, NC 28306 31 Phone number(s): 910-426-6777 32 Email sbrown@4dsitesolutions.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer GAR° ...., z. -1-.NFESS^ip ..,9, ��_ , . .) ti ot • _ _ J tA`,1-1,--.i-- - Signature ofsigner 027452 - •. NGIN• E‹ ��_. ' SCOTy ?Rsos ,"' ` i(—Z9-z Seal Date DRAINAGE AREAS 1 4ls this a high density project'? No 2 ; If so number of drainage areas/SCMs 0 3 "Does this project have low density areas? Yes 4 ! If so,number of low density drainage areas 1 I I Is all/part of this project subject to previous rule 5 :versions? No I I O R rv1 S LOADED I max.. DRAINAGE AREA INFORMATION Entire Site LD 1 ....a, 4 Type of SCM Low Density t Low Density I 5 )Total drainage area(sq ft) iI 2,818,716 2 818 716 IT6 jOnsite drainage area(sq ft) 2,818,716 2,818 716 t 7 Offsite drainage area(sq ft) ) 8 tTotal BUA in project(sq ft) 3 169040 sf a 169040 sf . 1 "New BUA on subdivided lots(subject to 9 }permitting)(sq h). _ , ;New BUA not on subdivided lots(subject to .gZ( 144069 sf 144069 sf _._ j, 10 Ipermittin sf) t 11 Offsite BUA(sq ft) . .___ T. j 12 :Breakdown of new BUA not on subdivided lots: ( LI Parking(sq ft)1. . AA Roof(sq ft sq ft) ._ 7168 sf 0186 sf € 10186 t j 68 sf — I Roadway(sq_ft) 119099 sf 119099 sf i it Future(sgft) t 7616sf1 7616sf - f . Other, please specify in the comment box ✓ tsgft below( ) New infiltrating permeable pavement on t 13 }subdivided lots(sq ft) 1 t New infiltrating permeable pavement not on ) 114 `subdivided lots(sq ft) 1 ,. Existing BUA that will remain(not subject to ip 9)( q ) 15 " ermittin s ft 1 24971 sf g 24971 sf .._ @16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sgft) 393 sf 1 393 sf 18 I Percent BUA 6% I, 6% 19 [Design storm(inches) i 20 Design volume of SCM(cu ft) A 21 Calculation method for design volume ADDITIONAL INFORMATION ;Please use this space to provide any additional information about the 1 1 22 !drainage area(s): t Future BUA is allotted for the outparcel ;j i LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 Is protect below densely thresholds set forth in the applicable stormwater rule? Yes 1 2 Does protect maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 2:1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 3.6 1 6 Are curb outlet swales proposed? Yes • 7 Maximum longitudinal slope of curb outlet swale(s)(%) 1% i 8 Bottom width of curb outlet swale(s)(feet) 2 ft 9 Maximum side slope of curb outlet swale(s)(H:V) 3:1 10 Minimum length of curb outlet swale(s)(feet) 100 ft 11 Are treatment swales used instead of curb outlet swales? No l 12 Is stormwater released at the edge of the setback as dispersed flow? N/A 13 Have stormwater outlets been designed to prevent downslope erosion? Yes z 14 I Are variations to rule 1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: i i F q i Swale Drainage BUA Pervious Q Slope Va., Vacua Flow depth # fact tact Area (ac) area C (cis) (%) (fps) lfps) (It) 1 2.44 1.88 0.56 0.80 15.39 0.85 4.50 2.61 1.25 2 12.27 5.67 6.61 0.60 35.60 0.36 4.50 2.33 1.95 3 12.71 5.86 6.84 0.60 36.85 0 36 4.50 2.53 2.25 4 14.88 5.72 9.15 0.55 31.58 0.36 4.50 2.43 2.10 6 15.44 5.94 9.50 0.55 32.77 0.36 2.00 1.49 2.13 8 7 8 , 9 i0 11 12 ... 13 14 15 16 17 I 18 19 20 , 21 22 23 24 25 26 27 28 , 29 30