Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0003304_Application (FTSE)_20231215
DoCuSign Envelope ID:E5B0023F-COF5-4CBC-89CF-BE0004CFA475 State of North Carolina Department of Environmental Quality DWR Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 06-21 &SUPPORTING DOCUMENTATION Application Number: DD3549(-YYlo,,,, (to be completed by DWR) All items must be completed or the application will be returned NOV 2 7 2023 1. APPLICANT INFORMATION: I. Applicant's name: Town of Holly Springs 2. Applicant type: ❑ Individual ❑Corporation ❑General Partnership ❑Privately-Owned Public Utility ❑Federal ❑ State/County ® Municipal ❑Other 3. Signature authority's name: Kendra D.Parrish,PE per 15A NCAC 02T.0106(bl Title: Executive Director of Utilities&Infrastructure Service 4. Applicant's mailing address: 128 South Main Street, PO Box 8 City: Holly Springs State:NC. Zip:27540 5. Applicant's contact information: emily.koncz@hollyspringsnc.gov Phone number:(919)577-3150 Email Address: Kendra.parrish_,hollysspringsnc.gov IL PROJECT INFORMATION: I. Project name: NC-55 Roadway Improvements Sewer Extension-Modification 2. Application/Project status: ❑Proposed(New Permit) ® Existing Permit/Project If a modification,provide the existing permit number: WQop_03304M and issued date: 1 1/16/1995 For modifications,also attach a detailed narrative description as oescriDed in Item G of the checklist. If new construction,but part of a master plan,provide the existing permit number: WQ00 3. County where project is located: Wake 4. Approximate Coordinates(Decimal Degrees): Latitude: 35.6566 Longitude: -78.8321_' 5. Parcel ID(if applicable) : 0003392 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: 1. Professional Engineer: Nick Williamson License Number: 48250 Firm: McAdams Mailing address: 2905 Meridian Parkway _ City: Durham State: NC Zip: 27713 Phone number: _(919)948-8064_ Email Address: : williamsonCc,D_mcadamsco.com IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION: 1. Facility Name:Utley Creek Water Reclamation Facility Permit Number: NCO063096 Owner Name: Town of Holly Springs V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(si. W000 31298 2. Downstream (Receiving)Sewer Information: 12 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s)(if applicable): WQCS00192 Owner Name(s):Town of Holly Springs FORM: FTA 06-21 Page ] of 5 Dodu5ign Endelope ID:E5B0023F-COF5-4CBC-89CF-BE0004CFA475 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been attached? El Yes El No ®NA 2. If the Applicant is a Developer of lots to be sold,has a Developer's Operational Agreem n FORM: DEVI been attached? ❑Yes ❑No ®NIA 3. If the Applicant is a Home/Property Owners'Association,has an HOA,'POA Operational _Agreement(FORM: HOA)and supplementary documentation as required by I SA NCAC 02T.0I 15(c) been attached? ❑Yes ❑No ®N.'A 4. Origin of wastewater:(check all that apply): Note - there are no new flows proposed with this application. ❑ Residential(Individually Owned) ❑Retail(stores,centers,malls) EJ Car Wash ❑ Residential(Leased) ❑Retail with food preparation/service ❑ Hotel and:or Motels ❑ School preschool day care ❑Medical'dental!veterinary facilities ❑Swimming Pool/Clubhouse ❑ Food and drink facilities ❑Church ❑Swimming PooFFilter Backwash ❑ Businesses 'offices/factories ❑Nursing Home ®Other(Explain in Attachment) 5. Nature of wastewater: "•o Domestic _%Commercial _°o Industrial(See 15A NCAC 02T.0103(20)) If Industrial,is there a Pretreatment Program in effect?❑Yes[-]No 6. Hasa flow reduction been approved under 15A NCAC 02T.0114(f)? ❑ Yes ®No ➢ If yes,Provide a cony of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type(see 02T.0114(f)) Daily Design Flow"° No.of Units Flow Various existing domestic and commercial flows 31720 gal/day 1 31,720 GPD gal/day GPD gal/day GPD gal/day GPD - - - -- gal/ GPD Please note - this is the flows from the existing application and no new flows are proposed _ gal/ GPD with the modification to this application. - --4 1 Toga! 31,720 3PD a See 15A NCAC 02T .0114(b),Ld),tel(I)and M2) for caveats to wastewater design flow rates(i,e., minimum flow per dwelling;proposed unknown non-residential development uses;public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.42A4). b Per 15A NCAC 02T.0114(c),design flow rates for establishments not identified [in table I SA NCAC 02T.01 141 shall be determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data. 8. Wastewater generated by project: _ _ 0 GPD(per 15A NCAC 02T.0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero,please indicate why: ❑ Pump Station'Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ®Other(Explain):Please see the cover letter for explanation FORM: FTA 06-21 Page 2 of 5 DoCuSign Envelope ID:E5B0023F-COF5-4CBC-89CF-BE0004CFA475 Vil. GRAVITY SEWER DESIGN CRITERIA(If Applicable)-OTh.0305& MDC(Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size(inches) Length(feet) Material IThe previous application contained 16,095 LF of 8" 12-inch 4,277 PVC 1PVC sanitary sewer line - 8-inch 11,818 PVC 'quantities shown include 4,277 of new 12" line that replace the same quantity of previous existing 8" line. The total sewer length is not changed since line is 'ust being upsized. ➢ Section II&III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA(If Applicable)—02T.0305& MDC(Pump S1tttion31Force MAIns): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station number or name: Easton Acres Pump Station _ 2. Approximate Coordinates(Decimal Degrees): Latitude: 35,6755 Longitude: -78.8400 3. Total number of pumps at the pump station: 2 3. Design flow of the pump station: 0.032 millions gallons per day(firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s)per pump(s): 22 gallons per minute(GPM)at: feet total dynamic head(TDH) 5. Summarize the force main to be permitted(for this Pump Station): Size(inches) Length(feet) Material 4-inch 2,086 If any portion of the force main is less than 4-inches in diameter,please identify the method of solids reduction per MDCPSFM Section 2.01C.1.b. ❑Grinder Pump ❑ Mechanical Bar Screen ❑Other(please specify)_ 6. Power reliability in accordance with 15A NCAC 02T.0305lhH 1): ® Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry- 15A NCAC 02T.0305(h)(1)(B); ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation,quick-connection receptacle and telemetry- or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations,an evaluation of al I the pump stations'storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes,shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 DoeuSign Envelope ID:E580023F-COF5.4CBC-89CF-BE0004CFA475 IX. SETBACKS&SEPARATIONS—(02B.0200 & 15A NCAC 02T.0305(f)): I. Does the project comply with all separationslalternatives found in 15A NCAC 02T.0305(f)&(g)? ® Yes [—]No 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below(vertical) 18 inches Water mains(vertical -water over sewer preferred, including in benched trenches) 18 inches 'Water mains(horizontal) 10 feet Reclaimed water lines(vertical -reclaimed over sewer) 18 inches Reclaimed water lines(horizontal -reclaimed over sewer) 2 feet **Any private or public water supply source,including any wells,WS-1 waters of Class 1 or Class II impounded reservoirs used as a source of drinking water,and associated wetlands. 100 feet **Waters classified WS(except WS-I or WS-V),B,SA,ORW,HQW,or SB from normal high water(or tide elevation)and wetlands associated with these waters(see item IX.2) 50 feet **Any other stream,lake,impoundment,or ground water lowering and surface drainage ditches,as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation(horizontal) 5 feet Any basement(horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade(vertical) 36 inches ➢ If noncompliance with 02T.0305(f)or(a), see Section X.I of this application *15A NCAC 02T.0305(g)contains alternatives where separations in 02T.0305(f)cannot be achieved. Please check"yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications w•ebyage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes [—]No ❑N:'A ➢ If no,please refer to 15A NCAC 18C.0906(f)for documentation requirements and submit a separate document, signed'sealed by an NC licensed PE,verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑No ❑N A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name:Neuse ❑No If yes,does the project comply with setbacks found in the river basin rules per 15A NCAC 02¢.0200? ® Yes ❑No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage.'authorization under a 404 Nationwide/individual permits ®Yes ❑No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coveragefauthorization is required. 1 6. Does project comply with 15A NCAC 02T.0105(cx6)(additional permits�certifications)? ®Yes [:]No Per 15A NCAC 02T.0105(c)(6),directly related environmental permits or certification applications must be being prepared, have been applied for,or have been obtained. Issuance of this permit is contingent on issuance of dependent permits(erosion and sedimentation control plans,stormwater management plans,etc.). 7. Does this project include any sewer collection lines that are deemed"high-priority?" ❑Yes ®No Per 15.A NC '02T.040'_,"high-priority sewer"means any aerial sewer,sewer contacting surface waters, siphon,or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes,include an attachment with details for each line,including type(aerial line,size,material,and location). High priority lines shall be inspected by the permittee or its representative at least once every six-months and inspections documented per 15A NCAC 02T.0403(a)(5)or the permittee's individual System-Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 DoduSign Envelope ID:ESBOO23F-COF5-4CBC-89CF-BE0004CFA475 X. CERTIFICATIONS: 1. Does the submitted system comply with ISA NCAC 02T,the Minimum Design Criteria for the Permitting of Pump Stations and Force_.Nlains(latest version),and the Umvi(y Sewer Minimum Design Criteria(latest version)as applicable? ® Yes ❑No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and proiects requiring a variance approval may be subiect to longer review times. For proiects requiring two or more variances or where the variance is determined by the Division to be a si nificant portion of the ro'ect the full technical review is required. 2. Professional Engineer's Certification: 1, Nick Williamson ,attest that this application for NC-55 Roadway Improvements Sewer rxlension-Modificalion (Professional Engineer's name from Application Item III l ) (Project Name from Application Item II I) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,engineering calculations,and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, MinintlMpC§ign Criteria for Gravity Sewers(latest version),and the Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains(latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE In accordance with General Statutes 143-215.6A and 1143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000,as well as civil penalties up to$25,000 per violation. Misrepresentation of the application information,including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina-licensed Professional Engineer to referral to the licensing board.(21 NCAC 56.0701) North Carolina Professional Engineer's seal,signature,and date: •���•``�N CAROB "*e Q- SEAL Z 0482502 o..usron.a by: ����C��CF/1rG,111��'�'�s��•�� 10MM............................................... 3. Applicant's Certification per 15A NCAC 02T.0106(b): 1, Kendra D.Parrish.PE ,attest that this application for NC-55 Roadway Improvements Sewer Extension-Modification (Signature Authority Name from Application Item 13) (Project Name from Application Item II 11 attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non-discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,injunctive relief,and,-or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000 as well as civil penalties up to$25,000 per violation. uacuSgn.e by. Signature: � ` - Date: 11/21/2023 03C05"9K.U440 FORM: FTA 06-21 Page 5 of 5 DoduSign EnJelope ID:E5B0023F-COFS-4CBC-89CF-BE0004CFA475 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-23) Entity Requesting Allocation: Town of Holly Springs Project Name for which flow is being requested: NC-55 Roadway Improvements Sewer Extension-Modification More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Utley Creek Wastewater Treatment Plant b. WWTP Facility Permit #: NC 0063096 All flows are in MGD c. WWTP facility's permitted flow 6.0 MGD d. Estimated obligated flow not yet tributary to the WWTP 1.860 MGD e. WWTP facility's actual avg. flow 3.077 MGD f. Total flow for this specific request 0 MGD g. Total actual and obligated flows to the facility 4.938 MGD h. Percent of permitted flow used 82% 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Average Approx. Obligated. Total Pump Pump Daily Current Not Yet Current Station Station Firm Flow** Avg. Daily Tributary Flow Plus (Name or Permit Capacity,• (Firm pf), Flow, Daily Flow, Obligated Available Number) No _LMGD MGD MGD MGD Flow Capacity*** Twelve Oaks W00030814M 4.140 1.656 0.517 0.096 0.613 1.043 *The Firm Capacity(design flow)of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor(pf)not less than 2.5,per Section 2.02(A)(4)(c)of the Minimum Design Criteria. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is<0. Downstream Facility Name (Sewer): Twelve Oaks Pump Station Page 1 of 9 FTSh 10-23 DocuSign Endelope ID:E5B0023F-COF5-4CBC-89CF-BE0004CFA475 Downstream Permit Number: III. Certification Statement: I Kendra D. Parrish certify to the best of my knowledge that the addition of the volume ofwastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Docaslgn•e by 11/21/2023 Signing rcial Signature Date Exec Director of utilities and Infrastructure Title of Signing Official Page 2 of 9 FTSE 10-23 DoduSign EnJelope ID:E580023F-COF5-4CBC-89CF-BE0004CFA475 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is-0. Pump Station(Name or Number): Given that: a. The proportion and amount of Obligated,Not Yet Tributary Daily Flow(C)accounts for %and MGD of the Available Capacity (E) in Pump Station ;and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD per year;and that c. A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in ;and/or d. The following applies: Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over-allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143- 215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Official Signature Date Page 4 of 9 FTSE 10-23 1 I APED/ _ •• -1 � ��-,>,F_` .- era l Al xis I Mily upgraded. Y � I • • �n�,.�4�J�J�� _wow *"Em �611.ev", I K,14, 1 4 �i NO) is •� I TOPOGRAPHICVIA 10 012 Ali kBoll W NO I MR, WAIMP INN N MAIN STREET VISTA USGS A PROJECT#: 1 , 1 1,000 2.000 4,000 HOLLY NORTH CAROLINA ,,, Feet AV] UJI, M �• • ••• :11 1 : 111• iT.j�'�'.!<YY+C 3.7�,�[�/ �}�• R1'�i i0. ,T ALIT.<'r °'� ..�, y r _ •,r Nor�f 1.'!� i Ir.,� ��. �/f i O �4 �-2 �'vit t ;"Y' y'7� 'fir+' •;h�lir JY y»� � I � >�M A ode' try. _;� � _ !�` • rt�= ►, 4• 9 � s •1 1., /tad•.,1 _ r• J ' r. JJ,ab iL �� r �• —�� _fir welly�n.�.ys Rd � 41I LAW. R��Sp ��{` "fin ~�- 7� , • � � �' �1 'J'.,,''�f• . w F., o "1� ♦ M t 'r R�p1 AI, y prinSt gs„� '' �.f• :`I ` •�.' e �fIII�FF+�, U �' t 1 1[ _ f r;y�• I_ Imo_ j.6 �7. `�-•.T" r -i L• T _ �a��,� K N'� ,fJ- r �/ � .�y�,_��i. v ` f. Y i.r.' �0'03! .� !ice ♦' ,I r � v i�11a � 1•pn � Y 1^ 1 �.' •+ may* �r, M 1� r �+ . i' ' ,Ye W irl a •„'.r' 1. ,. t 1. I• Transportation Improvements ExtensionSewer Aerial • 0 250 500 1,000 HOLLY •r CAROLINA DocuSign Envblope ID:E5B0023F-COF5-4CBC-89CF-BE0004CFA475 a l7 y 8.3, ... ui a M 3 o Z r fY. vai o W Z O �x Lp N IL 1 ��� `� a 19(O� LCL I ' I �A tlt;• I ��-i Un ad $ ' L Z E n c2 m j II( h � I II i} -` 1 � •_ '�^_�.:. i c_ �� 1 ,1' � 1 I l •• ' I +!l1I��- t ..._. to V I 1 I III L_. 1 1y I 1 �{ . I� k r yy 1 F I! 7 1 1 LEI Hs El a 7"R DocuSign Envelope ID!E5RU023F-COF5-4CBC-89CF-BEOOD4CFA475 J MCA DA M'--, COVER LETTER > VIS-22003 November 17,2023 NOV 2 7 2023 NCDENR- DWR Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 ( DS W00003304M �{1J Re: NC-55 Roadway Improvements Sewer Extension—ModificationMU Holly Springs, North Carolina VIS-22003 The accompanied Fast-Track Application (FTA 06-21) includes 4,277 linear feet of 12" PVC public sewer. The 12" line being installed is replacing existing 8"sewer within the Town of Holly Springs's current sewer network that is undersized. The existing 8" line is being removed and replaced with the 12" line listed in this permit. The sewer is planned to be removed and replaced in the same location,but new pipes and manholes will be used for replacement of the upsized line. This work will occur roughly from the location of Cayman Avenue/North Main Street all the way up to Sportsmanship Way/North Main Street in Holly Springs, NC. The existing permit WQ0003304 is being modified for the above as described—4,277 LF of 8 inch gravity sewer is being removed from the existing permit, but the remaining 11,818 LF of 8 inch gravity sewer will continue to operate as It was previously permitted. A 22 gpm pump station with duplex pumps,stand-by power, and approximately 2,086 I near feet of fl- inch force main will continue to serve Easton Acres. The existing flow of 31,720 GPD under this permit will remain and is already tributary to the plant. This permit application is just for the sewer being replaced as described above. It is being submitted with two other applications for the project that Is triggering the upgrades to this line. Those applications speak to an existing pump station that is to be taken offline as a result of the proposed project and new sewer lines being installed in order to serve that project. There Is a new application being submitted in tandem with this modification that is for the proposed project that is producing 73,079 GPD of flow. That flow is being permitted separately as part of that permit. Zero additional flows are included with this permit application. The sewer system will be a public system owned and operated by the Town of Holly Springs once it has been accepted after construction. The work for this sewer to be replaced is expected to begin in late Winter 2024. Sincerely, MCADAMS Nick Williamson, PE Project Manager, Residential Y V Enclosures t,r'experiences through e,pericnce 2905 Meridian Parkway,Durham,NC 27713/919 361 51300 DowSign Errvelope ID:E560023F-COF5-4CBC-89CF-BE0004CFA475 all 11 ' ]] ySpringsT HE TOWN OF �9 ol-L November 21, 2023 Director, Division of Water Resources Raleigh Regional Office Water Quality Operation Section 3800 Barrett Drive Raleigh,NC 27609 Re: Application for Sewer Extension Permit MODIFICATION Project: NC-55 Transportation Improvements Permit Number: WQ0003304M Dear Sir or Madam: In response to Elaine Wild's e-mail request for addition information dated 10/24/2023, please find enclosed the following items in application for a sewer extension permit to the Town of Holly Springs existing sewer distribution system: 0 One original and one copy cover letter including a project narrative o A check in the amount of$600.00 0 One original and one copy of the State of North Carolina Fast Track Sewer System Extension Application(FTA 06-21) 0 Two copies of FTSE 10-23 Flow Tracking/Acceptance Form o Two color copies of a 8.5-inch by 1 1-inch portion of a 7.5 minute USGS Topographic Map showing project area 0 Two copies of a street level map showing all relevant project areas 0 One copy of the locally-required Design and Application Certification 0 One copy of the existing permit WQ0003304M Feel free to contact me at 919-577-3150 should you have any questions or need additional information in order to process this application. Sincerely, ps og Docu44pn by - �M f� Kendra .Varrish, P.E., CFM Rachel Ingham catherine Jacobs Executive Director of Utilities and Infrastructure KP/ek cc: Project Consultant Engineer, Nick Williamson, PE Rachel Ingham, Utility Engineering Manager Drew Johnson, Development Construction Manager 3fx;� 041?zuls Utilities and Infrastructure Services P.O. Box 8 - 128 S. Main Street - Holly Springs, NC 27540 - www.hollyspringsnc.gov DocuSign Envelope ID:E5B0023F-COF5-4CBC-89CF-BE0004CFA475 ,;�k„ws•r►�. THE TOWN OF 011y Springs Emily Koncz, Utility Permitting Specialist Project file/Correspondence#42144 3002 04 172018 Utilities and Infrastructure Services P.O. Box 8 • 128 S. Main Street 9 Holly Springs, NC 27540 • www.hollyspringsnc.gov Dot:uSign Envelope ID:E5B0023F-COF5-4CBC-89CF-BE0004CFA475 DO NOT SUBMIT SEWER EXTENSION APPLICATIONS UNTIL CONSTRUCTION DRAWINGS HAVE BEEN APPROVED BY STAFF! Sewer Design and Application Certification Note: This form must be submitted with the Fast Tract Application for extension to the Town of Holly Springs Sewer System Project: NC-55 Roadway Improvements Sewer Extension - Modification Design Engineer: Nick Williamson Address: 2905 Meridian Parkway, Durham, NC 27713 Phone Number: (919)948-8064 Email: williamson@mcadamsco.com Date Complete Application Package Received by Town: 11/21/2023 oa fops 09 Date Approved: PP (by RJ) C'_!_ (by KDP) c" (by CJ) As design engineer for this project, I certify the following (please check(x) each applicable box): ® That the design of the project is in complete conformance with the Town of Holly Springs Engineering Design and Construction Standards and NC DEQ Sanitary Sewer Design Regulations; ® That each of the following items are completed and enclosed for submittal to the State for a sewer extension permit: xi One original and one copy of a cover letter that includes a project narrative o A check in the amount of$480.00 to NC DEQ o A check in the amount of$200.00 to the Town of Holly Springs 0 One original and one copy of the State of North Carolina form FTA 04-16 Fast Tract Sewer System Extension Application 0 Two copies of form FTSE 10-18 Flow Tracking for Sewer Extension Applications 0 Two color copies of an 8.5-inch by 11-inch portion of a 7.5-m inute USGS Topographic Map showing project area 0 Two copies of a street level map showing all relevant project areas 0 One copy of the locally-required Design and Application Certification (This form) Design Engineer's Signature_ Date 11/17/2023 Please contact Emily Koncz at(919)557-2933 or emily.koncz(ii%hollysprinv,,.snc.goy if you have any questions. 2003 Sc,.vcr Design Application Certification 01 1421 Utilities and Infrastructure Services P.O. Box 8 • 128 S.Main Street • Holly Springs,NC 27540 • www.hollyspringsncgov ! j DEPARTMENT OF THE ARMY U.S.ARMY CORPS OF ENGINEERS,WILMINGTON DISTRICT WILMINGTON REGULATORY OFFICE 69 DARLINGTON AVENUE r WILMINGTON NORTH CAROLINA 28403 September 27, 2023 Regulatory Program/Division Marcos Vidal Vista Residential Partners NC, LLC 2964 Peachtree Road Suite 585 Atlanta, Georgia 30305 Via Email: my@vistarp.com Dear Mr./Ms. Vidal: This letter is in response to the Pre-Construction Notification (PCN) you submitted to the Wilmington District, Raleigh Regulatory Office on July 21, 2023, for a Department of the Army Nationwide permit (NWP) verification. This project has been assigned the file number SAW-2022-01030 and is known as Main Street Vista. This file number should be referenced in all correspondence concerning this project. A review of the information provided indicates that the proposed work would include the construction of six apartment buildings, two access drives (North Main Street and Holly Springs Road), drive aisles, parking, landscaping, hardscape, sidewalks, utilities and stormwater management measures. Impacts associated with this project are limited to 0.095 acre of fill to accommodate road and grading improvements within Wetland W1 (Impact W1). The project area for this determination includes the feature to be impacted and uplands immediately adjacent. The project/review area is located in the Middle Creek watershed of the Neuse River basin; in the northeastern quadrant of the intersection of North Main Street and Holly Springs Road, at Latitude 35.656625 and Longitude -78.833248; in Holly Springs, Wake County, North Carolina. We have determined that the proposed work is authorized by Nationwide Permit 29 pursuant to authorities under Section 10 of the Rivers and Harbors Act of 1899 (33 U.S.C. § 403), and/or Section 404 of the Clean Water Act (33 U.S.C. § 1344) and Section 14 of the Rivers and Harbors Act of 1899 (33 U.S.C. § 408). The proposed work must be accomplished in strict accordance with the general permit conditions, any regional conditions, the special conditions listed in this letter, the application materials, and the enclosed plans Main Street Vistas (9pp). If the extent of the project area and/or nature of the authorized impacts to waters are modified, a revised PCN must be submitted to this office for written approval before work is initiated. Any violation of permit conditions or deviation from your submitted plans may subject the permittee to enforcement action. This verification is valid until March 15, 2026, unless prior to this date the subject NWP(s) is suspended, revoked, or is modified such that the activity no longer complies with the terms and conditions of this NWP. If you commence or are under contract to commence this activity before the date that the relevant NWP is modified or revoked, you will have 12 months from the date of the modification or revocation of the NWP to complete the activity under the present terms and conditions of this NWP. Project Specific Special Conditions: 1. Suitable habitat for tricolored bat (Perimyotis subflavus) may be present at the site. On September 14, 2022, the USFWS published a proposal in the Federal Register to list the tricolored bat as endangered under the Endangered Species Act (ESA). The permittee understands and agrees that all work associated with the clearing and removal of trees and removal or modification of culverts must be completed prior to the effective date of the final listing in the Federal Register. Work associated with the aforementioned activities not completed by that time must cease and the permittee must contact the Corps' (insert PM contact information here) to determine if additional coordination with the United States Fish and Wildlife Service is required under Section 7 of the Endangered Species Act prior to continuing work. Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements. For activities occurring within the twenty coastal counties subject to regulation under the Coastal Area Management Act (CAMA), prior to beginning work you must contact the N.C. Division of Coastal Management in Wilmington, NC, at (910) 796-7215. This NWP verification does not preclude the necessity to obtain any other Federal, State, or local permits, licenses, and/or certifications, which may be required. If you have any questions related to this verification or have issues accessing documents referenced in this letter, please contact Lyle Phillips, Team Leader/ Wilmington District Liaison of the Raleigh Regulatory Office at 919-588-9200, by mail at the above address, or by email at George.L.Phillips@usace.army.mil. Please take a moment to complete our customer satisfaction survey located at https://regulatory.ops.usace.army.mil/customer-service-survey/. Sincerely, (" wx,"�� Chris Hopper Team Leader/ Wilmington District Liaison Enclosures Cc (w/enclosures) Michelle Measday, ECS Southeast, LLP (via MMeasday@ecslimited.com) General Conditions (33 CFR PART 320-330): 1. The time limit for completing the work authorized ends on March 15, 2026. 2. You must maintain the activity authorized by this permit in good condition and in conformance with the terms and conditions of this permit. You are not relieved of this requirement if you abandon the permitted activity, although you may make a good faith transfer to a third party in compliance with General Condition 4 below. Should you wish to cease to maintain the authorized activity or should you desire to abandon it without a good faith transfer, you must obtain a modification of this permit from this office, which may require restoration of the area. 3. If you discover any previously unknown historic or archeological remains while accomplishing the activity authorized by this permit, you must immediately notify this office of what you have found. We will initiate the Federal and state coordination required to determine if the remains warrant a recovery effort of if the site is eligible for listing in the National Register of Historic Places. 4. If you sell the property associated with this permit you must obtain the signature of the new owner on the transfer form attached to this letter and forward a copy to this office to validate the transfer of this authorization. 5. If a conditioned water quality certification has been issued for your project, you must comply with the conditions specified in the certification as special conditions to this permit. 6. You must allow a representative from this office to inspect the authorized activity at any time deemed necessary to ensure that it is being or has been accomplished in accordance with the terms and conditions of your permit. Compliance Certification Form Action ID Number: SAW-2022-01030 County: Wake Permittee: Vista Residential Partners NC, LLC, Marcos Vidal Project Name: Main Street Vista Date Verification Issued: 9/27/2023 Project Manager: Lyle Phillips Within 30 days of completion of the activity authorized by this permit and any mitigation required by the permit, sign this certification and return it to the following address: US ARMY CORPS OF ENGINEERS Wilmington District Attn: Lyle Phillips Raleigh Regulatory Office 3331 Heritage Trade Drive, Suite 105 Wake Forest, North Carolina 27587 or George.L.PhiIIips@usace.army.miI Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Engineers representative. Failure to comply with any terms or conditions of this authorization may result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I administrative penalty, or initiating other appropriate legal action. hereby certify that the work, and mitigation (if applicable), authorized by the above referenced permit has been completed in accordance with the terms and conditions of the said permit including any general or specific conditions. Date Authorized Work Started: Completed: Describe any deviations from permit (attach drawing(s) depicting the deviations): *Note: The description of any deviations on this form does not constitute approval by the Corps. Signature of Permittee Date ---- \X .T---- i vvr , A McADAMS ( a The John R.McAdams Company,Inc. ( -\\ 2905 Meridian Parkway I ----—- IT7 J -----------T --- ; ' non ' Durham,NC 27713 phone 919.361.5000 fax license number:3 261. 69C-187 `II I \\ \ \/�/ '\ www.mcadamsco.com INDEX D^`, CLIENT I I \\ \ VISTA RESIDENTIAL PARTNERS-INC,LLC N/F 11 \ y \\ SHARMA,BALK 1 r _ SHARMA,RADHA 1\ \ \ \\ -` GABRIEL/F CHAU, , 1_ _ 4000 WESTCHASE BOULEVARD,SUITE 220 PIN: :0057229 I I \ / / \ of KAM YAN RALEIGH,NORTH CAROLINA,27607 REID:005]229 / ZONING:NM PIN^06499^455S I N/F EXISTING PHONE:919.782.6652 \ GARRET RAILSBA(;K, I _�°° �e--�—�---� TRINIDAD COURT DB. 121 PGBACK n2 r PIN0649949, 432 W W 1- GARRE RAILS ---- --------\A\'� JVISTA RESIDENTIAL N/F / / / PARTNERS SHARMA.BALK \'\]I� — �' N' W N' W `� © _ DIL IN °°� L \\\. // / \ /) / I L————J I SNgRMA,8490 11 \ ���( F / PIN:0649849011 .I. _MNING:NMX 1V 1�11 v �o "' — _ nI Ll L II, // AWIINDER SNGH CHADA,J ( JAPI 06590400t12 ( ANTHONY W.AUG DB.18632,PG.2586 TRUSTEE, MARILYN M.U. --- ST EET N TRUSTEE EXISTING Al _ x PI DB0 1278. PG 2306 9041020 - ` . - THIRD STREET N � c "/F JACOB SITE LEGEND 7 Q OOSTRA � Z N \ PIN:065903188] O \\ \ 0 `\ 0 \\ DB.18305,PG.280 SIGNAGE Q \\ \ \ �' N/F \ \II h \ I I I.. ` E k \�\\ \ YARD LIGHTS / Q O z TgPATI05 LLC 1 \\ \ II �\ I / ` , - l I \\\ \\ ] J LIGHT POLE � /I"1 U I I I ` \.J PIN:0649839863 [ I a REID:0266787 \ \\ BUILDING II I I li I� \ / 'I \ \ --- '-l. POWER POLE z_ < r- �ZBNIN6: MX II 1 I r O I 1 I. �, I 11 T ter' I /`\\\ \�J y TRAFFIC DIRECTIONAL ARROW LU z �/ F / -- x "/P \ ACC ACCESSIBLE PARKING STALL � aa \ 0 LISA MAN \ OC O L_zr J \ \\ 11 - - - - 4° 0 I I BRIAN WHyiMAN SH/uE N Q \ I 4 1 I PINTO5550PG.21 / \ \ VAN VAN ACCESSIBLE PARKING STALL F z t \ Da.982//,PG.210 Y II \ // \\ \I �w �' I❑ Ir --_ I /� N\ HX PARKING SPACE COUNT U J N , � r ;I`I , --J — JI ST. \ TMP EQ � — J A N O----------- \ WILDING JEXISTING RE PE© —OHN000RT TV Z N \\�x \ O o =T \ • 0 0 0 0 0• ACCESSIBLE ROUTE 7N A J N/F \ . . PHASE LINE L 1 J N/F JOHNEI-Al M;BAYUS \ / `——T—_ O `,, 6 NRF LLV SPRINGS LLC \ \\ \ / I.... PIN:06590}1 29 �/ ——— RIGHT-OF-WAY WAY LINE G P 0649839676 \ Iv+ 300 NORTH MAIN STREET LLC Q DB.11139,PG.16F/ / PROPERTY LINE G r-I L--- _ EID:0326278 1\R` \\ti, PIN:06499326]8 H S\ LOT LINE ZONING:NMX \\\\`mi \\ ` DB.19113,PG.25]0 W // - \ / I - - - - EASEMENT LINE CENTERLINE ASPHALT UAVEMENT STREET B - oW I WINDWARD P TE HOA INC. \ PIA 065903421 ,A4��r�E r--I DO 1111,PG.231 �J ,,��A'\ �A/��.. N/F \ V\\\\\l I1\ \\ J LEE HOLLEMAN PIN 0649933690 r / �.... - L----_-- (\ \\\\\ 1 \ I DB.10098,PG.477 L-J \ I I 50 1 ELLEFIN EVELOP9ER L L C /IN:064993489 DB.15265,PG34 PG.20 BM.2013, 560\I 9 . I '95`G.EI SNE.E 'F L_-_-_ J \\\III \III\ \ L---_J I ,1-_« L l� I111 \11\ \\ F_ I �---- 1 �I BUILDING -- d ._1_ / q/y \ 111 — /I —I�� I •, r REVISIONS \1 I _--- 10�, L —I NO, DATE c EXISTING < < -�/ _ _ W_HOLLY SPRIN_GSROAD =-- __-------- _ -� -- L - J --�-------------- - ---- ---------_ __ __ / _ 1H EXISTING INGS T — — -7t �—TT+- SEE SHEET CO.00 FOR ALL PROJECT,SITE, OLLY S _ -- 1 ------- �— r PR -- --- --- ��1 ft- GRADING,STORM DRAINAGE AND UTILITY PLAN INFORMATION -------ate\ // r==x=x=-----_--x x--� u —_— } `— I I`/ ---- I --� —I---- NOTES \T\ �1 I / —+ - ~'I \ r- } �— — — — f J --i _ ALL CONSTRUCTION SHALL BE IN ACCORDANCE PROJECT NO. VI522003 8 r I I — � —I— / WITH THE CURRENT TOWN OF HOLLY SPRINGS FILENAME VIS22003-CD-OAS1 L — - L_ i r-- - I( _ \\ (\*; I�r III III III JI i I L-J i L-�r / / // ENGINEERING DESIGN AND CONSTRUCTION CHECKED BY NDW -- - I O r f STANDARDS DRAWN BY KWH \ �\ --I \/ /� L- / SCALE 1„_60, J \ \ DATE m.zl.zozs w _ L wl SHEET \ \ ! / / L— NEGal0(NAD83) OVERALL s SITE PLAN GRAPHIC SCALE i 0 30 60 120 C 2 00 I imh=60 R. FINAL DRAWING-NOT RELEASED FOR CONSTRUCTION 4:1 ASPHALT TAp1=R \ PERIMETER BUFFER N/F 1 " 15'xg466�AASHTO SIGHT \ CAST-IN-PLACE GABRIEL P.CHAN, OI�YANCE TRIANGLE ` RETAINING WALL &IMANTENANCE 01 KAM Y55 15 (DESIGN BY OTHERS) EASEMENT pB.19048,PG.2697 I os a os o:,e=os os I` _ zo- —— 1/� \6 I i®PQ w W W W — — - - - — SHARM�,@,AL K \.I.I - SHARMA, DNA 1 O•N\ \ \\ \ W W// W W /` N"CONSERVATION AA6 W l IT I A PIN:064 4 112 \ CL' REID:00 �9 \ \ 3' \ ` W/ ✓ W / 09EN SPACE?1 )'ZONING:I\MX\ \ 6 \ - / W W//w \W (18.816 sF) W ° T L- J 9 m --- (V 1 e © Mc � I � � W RI PRIVATE ASPHALr sJ ST M ATE CO TR L. s'R 3'R(TYP,) to'R 1 The John R.McAdams Company,Inc. PARKING LOT MEASURE'B' , _N - - 2905 Meridian Parkway \\\\ 11 \ ► \S (g\ �' \\ /�' r g _____'� i _ _ +ND aAO _ _ _ _ _____sR �� m v�~ 1 Durham,NC 27713 `t/ V� W �V I I 30R W 1 tl Cll I \ \ ____ _ ______ ---\- 1 I�+ �0 W\ w m \ ��/ w m o o r � _r____ _m o'all IMEASUAIE"A"' = phone 919.361.22690 STORM WATER CONTROL w ® ,«•.,, ..• ® I to V A1V A \� ,�� �� �, �,/ �, 4UNDERCROUND VAULT) o -... -. li O . •••.«•••• : 2• W\ \1 ^ / / N license number:C-0293,C-187 -i W ✓' W W W .I, - __ PRIN TE EMAINTENCES OTHERS) BLOCK C<• 1 WWW.mGadamsGO.[Om \ \ \ \\ By NI 1 F IGHT DF-WAY � L RTHERS) WALL �TJ N ; INDEX MAP CLIENT SHARMA,RADHA \ \ r \ \ \ \ �� VARIAW W1DT4 W V' W W \ G ) (— '1 PIN: :0072 34' \I \ S I C II �, �, I _ v-wnRK 9" VISTA RESTCHASAL PARTV R D,SUIT LC SHARMA BALK 1 \ ; ('VARI 1 �LT A 5 ' BUILDING ZSF - L q A 4000 WESTCHASE BOULEVARD,SUITE 220 REID:DO]2034 1 1\ \ , fNCATION.� ZONING:NMX D 4'CONCRETE 1 \ 1 Ay, R �, Iw ( 097 SF) 5 BIKE SPACES RALEIGH,NORTH CAROLINA,27607 MEDIANS \ , \o '�EII-E I/t/1 o '18 2 18 4-STORY 44'-2}" I -SND PU R I i PHONE:919.782.6652 SE g11C - - TO �w)`I's - TREE GRATE(nv.) � r 20'IPubsDE 30 ♦ T •1 5O so � K • s0 � T2 ♦ 1 1 C• �s i � 30'R \ 30R „•••.. .. ... •. «« • ••••�« .. L VISTA RESIDENTIAL T2 ��••� � / q R 26245 EXISTING / 0+0 ' F�j \ 30R W♦♦ PARTNERS rv9Q 0000"E _R-200 op 3O'R TO 30'R ' THIRD S ET 6721 L=36.66' ity.pN TO I.�S]9'29 2 E s R A • • (VARIABLE WIDTH PUBLIC R ) 3o'R 3 00 5'R �p0000,E ; 0 -sz.9� _ _ � 05 �os�� ... ♦♦ FUTURE t `2 L=3868 TO - N R= Oro _ MONUMEN I L.••••• TQ y 1,11 TO NBO'IOR 30.0 AREA • "••••••• \ •1 J A�••_ O30'R TO 30'R ® • 10'R g I� ® ______ +SI • ._ L • \ ILLAGE GREEN \ 2♦ \ ', • • ® OPEN SPACE N2. A �2�k /� N O 4'CONCRETE �•1 \\ \ ,. ,� T2 ,I \� • \'� �� a' S. ♦ SITE LEGEND z Q r- MEDIANS 1 \ � 1j � � (V RETAININGLWA WALLS DRY 1 5' \� ` G�A ` x$ O a J,, • 4 BIKE SPACES PubSDE ♦ / ,/ SIGNAGE \\ • ) (DESIGN Br �� q/ * z \\ (F I4. \ \ : OTHERS) i.O, Itl RETAINING WALLS 2 s$ f�.A(�"$te /� \� • YARD LIGHTS `J < �V) J ODTHEIGN RS)BY - I / �/l (vr'I� \ LJI - 6 \2�,. �f`�/�`F/-/9� \�o \ I * UGHTPOLE LL `J 0 1 10'P,tSDE L_ 8 (0�/ Q 10 R N/F \ 1 \ I I - - - S A TO I'C T 1 ti POWER POLE z Q TAPATI05 LLC 1 \ ' -'\+ ♦ X ` S x W _ V PIN:0649839863 \ \ so\ " I TRAFFIC DIRECTIONAL ARROW z �/ _ REID:0Z 6]57 F ZONING:NMX \ a3. BUILDING t E BUILDING `� _� " SN \ VEV 4 EVSE SPACES ACC ACCESSIBLE PARKING STALL � � � \ \: O 2 EVSE SPACES / 4 O -- \\ L'R 24 UNITS SF I EV 'I STEM WALL / O \ /A TO / VAN VAN ACCESSIBLE PARKING STALL N \ 6q_' \ , / SLI UN WORK 4,884F 4 ,� so 30' Z 10 061 SF RETAIL TVP.( L I ( )\ 6LIVE WORN 4884SF 45TORY/54'-S I" II ' I EV❑ II C 4-STORY -6 e' ` � , so 30'R I XX PARKING SPACE COUNT ! 1 J N • `J \ • 1 (D \ 1 I\� ��` � ACCESSIBLE RAMPS � O z 10'TIRE PERIMETE'ABUFFER I 30'R "`� `_@_ __ 4 • �� • \`♦ 9 30'R m 1 N \ \ 30 R /a• TYPE(& TYPE(1 TYPE ©e - >W •••• :I I •••••••••• un ACCESSIBLE ROUTE A } --J 1 ` 1\ \I\ \ \ 10'sIDEPATH ACC 11� • ,�• `\ i r 1 =� • PHASE LINE J I i� I 1 \\ I • N G TO TQ x• MAINTENAN \\X 1 --- PROPERTY LINE G O rl O • VAN � g m GARAGE � \ 1 RIGHT-OF-WAY LINE TRA /RECYCLING • x SEGMENTAL BLOCK \ A A •I = 1 --_-- / 10'R x DOGxSPA v RETAINING WALLS^ _ LOT LINE 6 \4R\x ()ESIGN BY / \ • I I -1-STORY OTHERS) EASEMENT LINE / 1 5 TO - 1 t i m � \ \ 1 • ��• s Q l ,\ ` \ I \ I l l •.•. •• 12'1" I, \ • •• •••••••• ••• \ Pub50 R - CENTERILINE HEAVY DUTY PAVEMENT ` E 1 I ------------------ 10'R I �\\ I ASPHALT y10'TOHS-WE I.����- I • I \\ 8 BIKE 151.0924' STEM WALL ( I 1 / s' SPACES TYP HEAVVDUTY PERIMETER BUFFER ( TYPE CONCRETE PAVEMENT SEGMENTAL BLOCK \ 1 O E \ \ RETAINING WALL 30'R Irr `tl 4. \\ \\ \ 1 (DESIGN BY OTHERS) PubSDE PUBLIC NORM DRAINAGEEASEM - i¢�L %_ aL 1 PvtSDE PRIVATE STORM DRAINAGE � 50 GZ `\\ \\\ \ 1 �... -� I EASEMENT CIN'�E 4,0�: N/F A 50 \ \\ \\ \ \ 1 TOHS-WE TOWN OF HOLLY SPRINGSp�J� /- 1 \\ 6 ) 0 WATER EASEMENT NRF HOLLY SPRINGS LLC y \ \\ \ I \ N/F I SEGMENTAL OR I 63' I O 2O 6�LLL�L44• u I PIN:0649839676 <I RETAINING WA LS 300 NORTH MAIN STREET LLC (DESIGN BY L R 1 N EV (LEVEL 2J KING SPACE m REID:0326278 m�T \\ \ 1 \ PIN:0649932678 i --J ZONING:NMX G�J OG \\ \ \ \ 1 DB.19113,PG.2570 I PRIVATE ASPHALT -m� OTHERS) I V EVR EVSE READY PARKING SPACE c -J W (LEVEL 2) 1 \ \ I I f IW c Ln 111 \ \\ \\ \ 6 I STREET IIA311 �N 12.B. WIDTH P UBLIC R/W W SEE SHEET C5.01 -�LWi) (VARIABLE WI 3'DRY UTILITY 8'I 2 18' 18' 2 18' EASEMENT 1 \ e ------------------------ 1 REVISIONS d \I 6 DISTANCE ATRIAN SIGHT 5'TYPE'A' DISTANCE TRIANGLE I 1 TOHS-wE o 1 N0. DATE Ii\II.j _ J 5'R 5'R 1 PERIMETER BUFFER 13R(Yp o ' off\ 1\\\\\ I I I I (I ` __ ' E I.tORI. 20'R 30'R S --------------------�� _ 1 10'R \ m 30R • TO • - I \ \ 'i e ( • 9 0 3oz ® 1 SEE SHEET C0.00 FOR ALL PROJECT,SITE, TO I •" TQ • I GRADING,STORM DRAINAGE AND UTILITY PLAN INFORMATION 9, 1 \ \ 1 N/F 1. - - 1210o_ 1023LJ NOTES \ \ \ 1 \ I J.LEE HOLLEMAN L 6'� 11' / B \ 1i PIN:0649933690 y T2 N90'00'00'� PROJECT NO. VIS22003 = \�\ DB.10098.PG.477 R I ALL CONSTRUCTION SHALL BE IN ACCORDANCE 8 -- -- ------ \ 1 \ Q WITH THE CURRENT TOWN OF HOLLY SPRINGS FILENAME VIS22003-CD-S1 � \ 6 \\ \ \` \\ \\\ 9` ', \ \ II I - - -' - I • 30'R • ® I ENGINEERING DESIGN AND CONSTRUCTION CHECKED BY Now IB _ G. I STANDARDS DRAWN BY KWH \ \\ \ 9 I \ COMPACTOR/RECYCLING =os os l • �• SCALE 1"-30' \II\\\ \\ \\\ \\\\ \ 1+ 6 \\ L — .,-1 STREET IIBII o "1 DATE 07.21.2023 (VARIABLE WIDTH ; T° • SHEET -- -- -1 DJARK PUBLIC R/W) f 1 P \ \ \ \ \\ I OPEN0 SEE SHEETC5.01rvEORIU1NA0s310 SITE PLAN (5 • T2 ,-- - i GRAPHIC SCALE AREA.IA.. \\\\\\\ \\ \\\ \ \ \ \\ FENCE Lx-� J�T� *\ T° - 0 15 30 60 � Iimh=30rt. C •O 1 B � . E ~SEE SHEET C2.03 FINAL DRAWING-NOT RELEASED FOR CONSTRUCTION Y r-----� / --- --- 1 GABRIEL P.CHAU, 1 1 1 OI649 vnry STORMWATER CONTROL I r EXISTING _� 1 PIN:0649945515 CAST-IN-PLACE 1 IDS.19048,PG.2697 MEASURE"B" RETAINING WALL II 1 (UNDERGROUND VAULT) (DESIGN BY OTHERS) GARAGE N/F rJ I TRINIDAD COURT A L ee--�-�o A Y RAILS.-1 I (50'PUBLIC R/W) r __ ___ __ 4 EVSE GPRN:549949172w 1` 9 MCADAMS -� is SPACES 1 DB.1If030, Ts PC.43j 1 ' � 1-sroRv The John R.McAdams Company,Inc. 12'-1 e R AINING WALL Meridian Parkway O TOP V ,• (DIGN BY OTHERS) i \ Durham,NC 27713 111 1— V / 1 it Cll I 91 O r • ! i / phone fax 919.361.2269 0 w l� t VA 3'R ( Tom' 2� l: �I ,� © SEGMENTAL BL / \' / I license number:C-0293,C-187 Ln RETAINING WA I 1 LU (DESIGN BY O ENS) : 10'R 10'R /� / \ -- WWW.mCadam5C0.[Om W1 I i - 30'TY,� ----� INDEX MAP CLIENT PERIIoCC I % BUFFER / N L I s T l i / II II L _ VISTA RESIDENTIAL PARTNERS-NC,LLC r l♦ / I L 4000 WESTCHASE BOULEVARD,SUITE 220 mJ 7 I ••• ti I / I RALEIGH,NORTH CAROLINA,27607 20'PubsDE ♦ i•• • 10'R _. 1 o'R f,,\\ I /�� �S\ J/ I PHONE:91).782.6652 ♦ � T ♦♦ i PRI RKWG 1,�. JI / N/F ` ARVINDER SINGH CHADA, • ♦To BUILDING I/ �. ■ JAGTAR KAUR CHADA K •' \ ♦ 60 U NITSJ/S882,13]SF ••••• 10'R �I a DB.18632.PG.2586 ' 30' W ♦(6 LAVE-WORK/4,884SF) II' I N/F •••••• 10'PvfSDE I ANTHONY W.ADS `\ ♦4-STORY/48'-3 g" PERIMETER FENCE TRUSTEE. VISTA RESIDENTIAL �R. 40.25' h ♦♦ I MARILYN TRUSTEEAUB PARTNERS 'R t2845 'L� \ ♦ I/ PIND:0:5950 118020 30ps 5 9 ♦♦♦ B PG.2306 %0 \° ♦♦ STREET"A211 \ ♦♦ (VARIABLE WIDTH PUBLIC R/W)♦ SEE SHEET C5.00A iTill O I 30.5' \\ N/F `J L.rl os s � ` \ JACOB OOSTRA SITE LEGEND z Q � \ o �2°f jj I STEM WALL ,L� , , \ PN:0659 31887 ,- LitT-,—j T .) T _ _ \ Da 18305�PG.280 SIGNAGE � O Q \os � 4 BIKE SPACE YARD LIGHTS / �l �/7 o'R \ �I''L TQ r- ® I x� \ T UGHTPOLE Cf <J 0 os / /.\ isif•�!�♦:..•� ---- I \\ '-l. POWER POLE U 1-STORY \ \ TRAFFIC DIRECTIONAL ARROW Uj z �/ _ 10'R > > > > 30'R 12'-1 e' \ \ • ®i w 30R 30'R I i \\ \\ ACC ACCESSIBLE PARKING STALL O I 99 w w w VAN VAN ACCESSIBLE PARKING STALL N OL Z 10'TOHS-YrE _ _ _ _ s I I \ \\ HX PARKING SPACE COUNT U N 1 vv 30'Q / 11 5' 8' 6 EVSE SP CEO^ s .` SEGMENTAL LOCK I \ \ ACCESSIBLE RAMPS J- I�Z LEI I..�— -l•. .' TO `�\ INGW LL GARAGE x r\ \\ \ A 30 R j L .' (DESIGN BY THEIRS) \ \� LJ� O TYPE(& TYPE QB TYPE© CL 3Ln 0� / / ACCESSIBLE ROUTE A v w PIN-0 50AN S \ 1 ` 130.R • C �v v ® I,: m I \ • I-ii-i -ii-i I• PHASE LINE J 1 , M LISA HUE, \ " 10'PvtSDE ( BRIAN WH MAN SHUE \ G ? 1 \ -- PROPERTY LINE G O r-I re=1 a0.00' _I >a DB.98 7,PG.2106 // RIGHT-OF-WAY LINE 1 L=zosm I'/L 3" I. n5, / / 1 O - ( MAIL ROOM -- -- / ----- LOT LINE • STREET PUBLIC W) L / ' E EMENTLINE RETAINING WALL ------ x / 1 VARIABLE WIDTH — — — SEE SHEET C5.01 — (DESIGN BY OTHERS) / CENTERLINE 30'TYPE'C' 18' 24- is' F1124' 18 PERIMETER BUFFER \\ HEAVVDUTY 6 FINE PACES ASPHALT PAVEMENT 1 5R _ t •.0 _-t 1 PRIVATE AS HALT - HEAVVDUTY \6 LCA' p[' 1 3'R(TYP.) PARKING LOT 30.9, _ CONCRETE PAVEMENT p'��;\A R p C E i 1 PERIMETER FENCE �OF BUILDING Yl PubSDE PUBLIC STORM DRAINAGE 4 1 _ s cs o / ^\ \ EASEMENT _ _ _ Il- I 5F sxl \ \ PvtSDE PRIVATE STORM DRAINAGE 45 UNIT5578,394 50 ?_� EASEMENT 4-STORY 46'-3 a" • - E O I - - � \ � G EE of� 1 / •• • ••�i` 10'PvtSDE II `� \ TOHS-WE TOWN OF HOLLY SPRINGS •.�p"9S IN - • \N/F \ /2 WATER EASEMENT 1 r I • JOHN�8.BAYLS, 11 I \ / EV EVSE PARKINGSPACE I I ELAINE M,BAYUS 1 \ / 1-STORY PIN:0659 1629 / (LEVEL 2) DB.11139, GG.162 > / O AMENITY/POOL EVR EVSE READY PARKING SPACE N 1 OPEN SPACE#3 (LEVEL 2) ( 66 S 1 „] F) WALL I r �/ i N N m T..M / 1 - TO I �IY LU " ► 0 II m W GARAGE ry =1 0 LU I a m __, / W1 __________________P_ / --- - -------- REVISIONS e N 1 ����l�--�J� � s° — — — — — — � \� / PAVEMENT MARKING LEGEND / / LANE LINES/MARKINGS c ; •, ( SEGMENTAL BLOCK \\ \ / T2 24"WHITE STOPBAR RETAINING WALL SEGMENTAL BLOCK / NO, DATE / • 93 6' (DESIGN BY OTHERS) RETAINING WALL \ \(DESIGN By OTHERS) \ TO B"WHITE CROSSWALK LINE y ALL PAVEMENT MARKINGS SHALL BE THERMOPLASTIC AND ARE TO BE 2EVSE SPACES 10'PvISDE I \\ PLACED PER NCDOT STANDARDS(REFERENCE NCDOT DETAILS 5'R . L J \ I1206.01-1205.12) .L..N..... .N+..NN....• dd STREET LIBII 1 • --� (VARIABLE WIDTH PUBLIC R/W) "/F WINDWARD POINTE HOA INC. SEE SHEET CO.00 FOR ALL PROJECT,SITE, • i 1 io :o SEE SHEET C5.01 PIN:065903421 1 `- ••.-- Da.6637,PG.237 GRADING,STORM DRAINAGE AND UTILITY PLAN INFORMATION 3o R • •+'� NOTES o s 1 F Il T2 Q ALL CONSTRUCTION SHALL BE IN ACCORDANCE PROJECT NO. VIS22003 g f 1z�oo - - 11 iooNsvoo'oo'E + °0o FILENAME VIS22003-CD-51 m� � WITH THE CURRENT TOWN OF HOLLY SPRINGS TQ 21D23 TQ i I ENGINEERING DESIGN AND CONSTRUCTION CHECKED BY Now 1< Q 1oR ISTANDARDS DRAWN BY KWH 0R 3' 9 • ••• '�• •• 1 • • I SCALE 1"=30' - 1� • = DATE 07.21.2023 1 � ••••...••i•••... ••••.:. •N•N.a•••-••• T2 SHEET AA 5TYPE'A' 2 1 PERIMETER BUFFER - -- - - -- - -- BLUEFIN DEVE NF LOPERS LLC. 0 PINO649939489 NC GRID(NAD83) SITE PLAN $ 1 : DB.15265,PG.2034 AREA"B" 1 — o'Tous-wE BM.2013,Pc.560 GRAPHIC SCALE Q \�� I 0 15 30 T 60 S I T2 10'Pvt5D8 / C2e02 --------------------- ti �`�� Ij--------------------- -------------- (inch=30 k. SEE SHEET C2.03 FINAL DRAWING-NOT RELEASED FOR CONSTRUCTION 1 1 ' ' MCADAMS The John R.McAdams Company,Inc. �-- 2905 Meridian Parkway Durham,NC 27713 phone 919.361.5000 - - fax 919.361.2269 license number:C-0293,C-187 INDEX MAP w'ww.mcadamsco.com CLIENT VISTA RESIDENTIAL PARTNERS-INC,LLC 4000 WESTCHASE BOULEVARD,SUITE 220 RALEIGH,NORTH CAROLINA,27607 PHONE:919.782.6652 7 R VISTA RESIDENTIAL PARTNERS SEE SHEET C2.01 ---- --- _ SEE SHEET C2.02 ------------------------ -- —I— -8�- • r---`-------- ASPHALT PERIMETER BUFFER N/F • 10'R (,PARKING LOT BLUEEIN DEVELOPERS LIDO. f PIN:0649939489 ITDB.15265,PG.2034 • 10'R • 10'TOHS-WE BM.2013,PG.560 • T2 10'PvfGDE �` TREE GRATE • I 20'TORS \�`� / TRASH/RECYCLING (TVP.) - -SANITARY SEWER- - Ln r._ TO EASEMENT 'N `� .� (D C II � 4 EVSE SPACES w s~ w r\\ l ------ SITE LEGEND z Q P RTREE TO EMOVED BE N 20 R • U 9 \ I SIGNAGE \! Q AND STUMP • )9 - �' > ¢w \ • i 8 BIKE SPACES ■ ` ?j ,^ z CRINGED c 1 : A ♦ III I S YARD LIGHTS / Q/ �vr�I J �\•P • 635. �•.•.••••.• � sue•:- •..:a••a•. aT•••• M••••• J UGHTPOLE /� X R WLM 8 --------1 I ti POWER POLE V i /1 2' IL IL SEGMENTAL BLOCK r -� TRAFFIC DIRECTIONAL ARROW W • STREET A3 RETAINING WALLS 168' 1 1 W Z y� (DESIGN BY OTHERS) SEGIAENTAL BLOCK 1 ACC ACCESSIBLE PARKING STALL � K • (VARIABLE WIDTH PUBLIC R/W) RETPINING WALLS 1 I V) 0 III sl SEE SHEETC5.01 DE5IONBYOTHERS)1 VAN VAN ACCESSIBLE PARKINGSTALL z LI s ± BUILDING --- I HX PARKING SPACE COUNT 1 1 SEGMENTAL BLOCK -__ ----J ,A U N J ` RETAINING WALLS © V/ D J 0 \�•••• (DESIGN BY OTHERS)2(10061 IRETALIF I ACCESSIBLE RAMPS 2 N O �.•+-.. —�.Ii 10'TYPE'A �� a TYPE TYPEQB TYPE© T d PERIMETER BUFFER \ r -, • •• • •• ACCESSIBLE ROUTE L ' 1 N -- L� } RR •- PROPOSED ROAD IMPROVEMENTS MONVMENT 4 • \ EX.10'PRIVATE SANITARY FROM OTHERS(PART OF \ • - - - -�I• PHASE LINE G M J AREA B -� R • 10.6' 1 SEWER EASEMENT RO DTOWN/WIDENNGNCDOT OPROJECT)LL NGS I __ PROPERTY LINE G "�, 0 I I T2 - B.M.2013,PG.560 " I VARIABLE WIDTH — TQ • .... _.a• RRsLT-OF-WAY =I L --- RIGHT-OF-WAY LINE -- - DEDINTON �I 15'x450'AAS 30'R _- 4:1 ASPHAd TAPER I ®ORN J --—-- LOT LINE SIGHT DISTANCE 30'R ---�.�•�Ni • TO EXISTIN IPAVEMEN I j TRIANGLE _ • ---- `--- ,--- — — EASEMENT LINE _ ____ ____ _ -- 10'SI DEPATH 6 -- I - CENTERLINE -_ to __ _ _ HEAVYDUTY TPA SEGMEN BL TAL BLOCK .1 o m 1p _- ASPHALT PAVEMENT % RETAINING WALL - SHTO 0 0 - SIGH NCE T (STA AA�rxLAL�� 0\10 TRIANGE rMl /I I HEAVYDUTV AO�N OAR ---------------1J----- CONCRETE PAVEMENT O� E ATi ADDITIONAL PAVEMENT FOR FUTURE LANE SHOWN n.r oo F STRIPNG SHOWN PLbSDE PUBLICSTORM DRAINAGE , =QUO n� �_ n.irrr canMTAr. UNTIL ROAD IMPROVEMENTS ARE MDE TO THE EASEMENT _ _ EAST(PLANS BY OTHERS FOR TOWN PROJECT) 50 ----N __- _- -------- PvtSDE PRIVATE ST EASEMENTORM DRAINAGE , G ��� �'D / \ _ - _ � ?� TOHS-WE TOWN OF HOLLY SPRINGS ,qs I __ o PCN 6 ) z x x / WATER EASEMENT ` T6 1.0'YV\�AA i --- -\ -_J- - --- --- -r- --- -� / I HO I -� "-_- _-- / / EV EVSE PARKINGSPACE 2O , - -r--L (LEVEL 2) T IL HOLL EXISTING 1 -- I 1 r / / //� EVER EVSE READY PARKING SPACE -- f--�--- �I (VARIABLE WIDTH PUBLIC R/W) T F' I EXISTING I T — — —Ir-- — —r-_ — — t— —R tGRSTRE-ET—ei U 1 (VARIABLE-WIDTH PUBLIC R/W) >I r--,� ! / REVISIONS a N0. DATE 3 SEE SHEET CO.00 FOR ALL PROJECT,SITE, 3 GRADING,STORM DRAINAGE AND UTILITY PLAN INFORMATION NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE PROJECT NO. VI522003 8 WITH THE CURRENT TOWN OF HOLLY SPRINGS FILENAME VIS22003-CD-S1 ENGINEERING DESIGN AND CONSTRUCTION CHECKED BY Now STANDARDS DRAWN BY KWH SCALE 1"-30' DATE 07.21.2023 Qwl SHEET N DRIDINAD83, SITE PLAN s AREA"C' GRAPHIC SCALE i 0 16 30 60 C 2 O 3 I inch=30 rt. FINAL DRAWING-NOT RELEASED FOR CONSTRUCTION 1 1 McADAMS LpThe John R.McAdams Company,Inc. 2905 Meridian Parkway v \ - / - Durham,NC 27713 _ I - N \ I A / phone 919.361.5000 11 \ �\ I / ----- \ \ \ \ \ ■■ fax 919.361.2269 license number:C-0293,C-187 www.mcadamsco.com INDEX MAP 1 CLIENT N/F V11 so�� V / ---- -� / N A \ \\ V VISTA RESIDENTIAL PARTNERS-NC,LLC SHARMA,BAL K \ r- 1. - / 1 \\ / N/F - I \� \ _ \ _1_ _ 4000 WESTCHASE BOULEVARD,SUITE 220 /SHARMA,RADHA / \ \\ \1 \ / '.GPIO K P_QHAU, / PIN.0649849112 ° / \ oI KAM rCN \ RALEIGH,NORTH CAROLINA,27607 REID:0057229 / / / / ZONING.NMX \\ -- \ / / PIN:0649945515 I + N/F 1 / I %IUD > PHONE:919.782.6652 1p I� \\ \. W — +W— � .� _te-tee—to GARRET RAILSBAciK, I TRINIDADCOURT / � `� .■'o-� p m - - _ ��` — GARRETT RAILSBACK �1 I � \\\ c 1`i / y♦ -T PIN:06499491]2 DB. 16030.PG.432 \\o `W' W , W Jam. i / ♦�,, / ----� VISTA RESIDENTIAL r--1{, I I PARTNERS SHARMA,FBALK \' y d/ W ♦P �{� // // l (// 1 `� 11 I 1 L----{J \ SHARMA,RADHA 1 /y - \ / / \ / \ PIN:0649849011 \ — N, _/ UIL NG _ { I // / N/F / f/1 RED:00]2034 ----/`� 1 A A I 1 / -- / ZONING:NMX u, W y, ' - �' gRVIIXbER SINGH,CHgDA, I L / io_ _ _ _ _ L 7 JJ(GTAR KAUR dHADA /I LNl I PIN:06590p4pO 12 / ANTHONV_AUB ILDING _ - DB.18E3 /p 2586 / 1 TR TEE, MARK EEAUB T EXISTING I" oe85uzia20 THIRD STREET - / / PG.2306 / vI V.— — / 3 Rp Y ♦ �' _ _L ---z- --r--- --- I" ---�--- _-_ \ \ \ sT♦ \ \\ // JACOB OOSTRA// ,/I Z Q E — ♦♦ 0 % DaPIia3 a.Pc 67ao / GRADING LEGEND Q -/ -- \ m/ \ I \ I / ' \ ♦ + r _ i \\ /// X/ 1 134 FLARED END SECTION z / N/F \AA1 11\ \ I I \ \ \ I I C / // ENDWALL SECTION �N�rI''�� O TAPATIOS LLC 1 V PI a N:0649839863 \ � I I i 'I ♦ I - / / \ \/ /REID: 266 87 BUILD J I___ ___________� _ _ I/♦ \ 0 I _I _______� ' : / LISA QH � 7' - CATCH BASIN V 6:�M DROP INLET r = _ N/P/ STORM SERVICE INLET O If / II L zr i J // 11 1 " ♦'� \ / I, BRIAN PIN WHyTM 038 0'1 r'O E \ - ■ STORM SERVICE ROOF-DRAIN CI) O A t Y TOS$ 777 \w^ m --_- I DIE 982//,PG/210� Y' ♦ O JUNCTION BOX ' ` N `f \ / I '---J DRAINAGE FLOW A W LINE BREAK SYMBOL A 11 ` J \ DR GE F 0 RRO r�---------------- \ UILDING $ COURT 250.00 TOP&BOTTOM CURB ELEVATIONS — z EXISTING 250.50 z O T.JOHN = a O _T i �\ \ \TW=223.00 TOP OF WALL ELEVATION 7 ^ } �NJF �h _ BW=213.00 BOTTOM OF WALL ELEVATION \\\ L J JOHN M.BAYUS, // - NOTE: BOTTOM OF WALL IS GROUND G O m O N F / .Q \ 'I ELAINE MI BAYUS / ELEVATION NOT WALL FOUNDATION) Ng/ LLV SPRINGS LLC \ \ / / _ III PIN:0659 1629 / , _ - / 064/ \ \ �360 NORTH MAIN STREET LL / III / ` v 1 I (13 -I - P 983278 A PIN:06499326]8 / III r \\ li I\ DB.111391 P�16F// i/ }250.60 SPOT ELEVATION L_- EID:03262]8 rT1 ZONING:NMX' n - DE.19113,PG.25 0 \ I ----- / / STORM DRAINAGE I3' — STORM SERVICE LINE I I �\\\ —RD—RD—RD— L / / F NON-PERFORATED ADS OR EQUAL 1.0%MIN SLOPE 3 MIN COVER PVC SCHEDULE 40 IN � STREE B r I l I N/F f I _ / TRAFFIC AREAS V�INDWARD POINTE HOA NC. II -------/!------ / If \\ - I( . / / PI6637,03421 \ —TP—TP—TP— TREE PROTECTION FENCE / _` wf I a� / r-� 1 DB.883],PG.237\ �♦A♦�,�N 1S/F _ —__ __ I \ LDLO LIMITS OF DISTURBANCE P�� E „ //JN:0649933890N /N I 1 \ I 19B.10098.PG.477 / / / L-_J / WOODED AREA N/F \ --- 250 MAJOR CONTOUR E OZ ;\'\ ` \ •I I V // r-J _______ BLUER DEVELOPERS LLC. \ / 252 MINOR CONTOUR PIN:0649939489 95 X Da.15265,W.2034 \ __---250---_ EXISTING MAJOR CONTOUR / J' / \ ✓ / L_J / BM.2013,PG.560 / _______ ______ I \\ / 252 _ EXISTING MINOR CONTOUR --�--� I EASEMENT LINE r /I // // \ \\ \ / / / I / r■, I �r Tl I - - I I \ I I ACCESSIBLE PARKING AREA / \ V \ (2%MAX.SLOPE IN ALL DIRECTIONS) F F-1- Il /- „ f I BUILDING If J REVISIONS g =�—. — r / -- �� \ _ =r I \ \ � � - - - I I■°" I; N0. DATE EXISTINGL T— -��.c—a-�•� 5 �� c a ty— ���- „ ___--_ - , 3 / �_ G_HOLLYSPRINGSf(6AD -_ =_4�I / En -T� _ a E. - SEE SHEET CO.00 FOR ALL PROJECT,SITE, GRADING,STORM DRAINAGE AND UTILITY PLAN INFORMATION - i ---— NOTES �_I_ /�_ / I / / _ ��-� -- __ PROJECT NO. VIS22003 _ K k —X / __ -4- --F _ ____I _ / ALL CONSTRUCTION SHALL BE IN ACCORDANCE 8 / / / L/ 1 f �� I L — \ —z — WITH THE CURRENT TOWN OF HOLLY SPRINGS FILENAME VIS22003-CD-OAG1 / / I / 1 / �A --I_,� / �I AI 1 ��� r�� r✓ / ENGINEERING DESIGN AND CONSTRUCTION CHECKED BY NDW L-�--� I 1 I v I L- STANDARDS DRAWN BY KWH \ _ l� 4Q r-- / I V A / SCALE 1"=60, �\A L-L-1 II \V L--� I I ch \ lip/ DATE 07.2E 2023 L N SHEET NCGRI0(NA083) OVERALL GRADING AND s STORM DRAINAGE PLAN GRAPHIC SCALE i 0 30 IinCh60�k 120 C3e00 FINAL DRAWING-NOT RELEASED FOR CONSTRUCTION BU CHAD 1 / CAST-IN-PLACE / PRIVATE A CESS / 1 5 \ / I I I OJ KAM YAN / 15'x].5'x RETAINING WALL $MAINTE ANCE \ \ 8\ \I\ 9 \ I \ \ 22"THICK T kASEMEN 10.37 LF 5"RCP �1904899PG.26 1 9B. 9] 1/ \ RIP AP TW=426.00 (DESIGN BY OTHERS) iW=42.50 / ➢ ®1.459y� TW=432 50 1 ew=43 so / - - - - B=ansO - - - - _ - 0 -dam CA 1 o:�o:�Ts�o:a os.,�o:.T=o:v--os•%os os�l` �=i>r--- �- - 1/� 5 \6\\ ®W W B 3052].4 15'RCP 0.a R Cg1o7 - / SHARM,�,@AL`K� \ 1 II 1 I SHARMA,\RqDry'1 PIN:064984911,2 - A REID:0�72';9\\ 9 / YYY W/ ✓ W / W _ _ J� zorvlNc:v\Mx\S 1 AI\ �� �V // �\\� STOAMWATER CO�TROL �EOP-3o]A IN 1 ( e © cADA S MEASURE"B ---- ;O The John R.McAdams Company, (UNDERGROUND VA rrj Inc. W\ I Bw=a1 so / _ - - - 1 U 1� �I 2905 Meridian Parkway 6 \/ \w \.H Vv- w w w I1r _ 0 1.97% -c 1 Durham,NC 27713 W I I ____________________________ _________ _____�TW=435.50 _ ____ __ 1 w 1 IICII 1 '•'- \ I \, VVV �G �/ -r------- BW=433.00 1= phone 919.361.5000 5 \g �� STORMWATER CON OL \ € 11 - / DEEASUIYE"A4T / 4-41 L 12-HOPE 1 w fax 919.r:C-2269 W /meµ �,,I N=EERCTROUND 1(A LT) .y 0.74 1 3 a I w license number:C-0293,C-187 t s �I //. /w I 1 �� w ws � • / SEGMENTAL BLOCK II 1� www.mcadamsco.com \ \ 1 \ \ , ✓' W W W PRIVATE ACCESS RETAINING WALL 5.07 LF 12"HDPE CB+3 I s I \ I \ \ / - W: 1 &MAINTENANCE I (DESIGN BY 1 INDEX M A P N/F \_ W J W W V' /Jg c-- EASEMENT BUILDING OTHERS) ®b gljF 15"RC co-3o1A 1 CLIENT SHARMA,SAL K \ \ / 7,20 LF 12"HDPE EO-2b SHARMA,RA°HA �1`\ \\ VARIABILE WIDTH) W W W /W I O 0 1 3gy, 1 PIN ofia9'49on ICHT-of-WAY / o - FFE=433.00 VISTA RESIDENTIAL PARTNERS-NC,LLC REID:0072034 \ \ �\ \ \ fNCATION,R S�'DC 11 / -�i YI-303 ---- �EO-300 `R I _ 4000 WESTCHASE BOULEVARD,SUITE 220 zorvwc:NMx �\ I f \ \ \" a""'14B_LE t jDT v,-4 e �5 / 29.29 .2 L 12 HOPE RALEIGH,NORTH CAROLINA,27607 � I ° x I C _ PHONE:919.782.6652 SEf SHEE H PSD&LIC R�hy ° I M=434.50 co-3o1B ='y-00 ',✓ ___�- BW=433.00 a 182$LF 24" - HD 9.00 LF,2" PE ' CB-0, YI-302 I -zoz I♦♦♦ R a c \\ 3S6 B-210 \ / �� ♦ VISTA RESIDENTIAL =a,soo EXISTING g c W \ } `- BW=4140 38.19 LF 4"RCP ' \ 55. LF CP ♦ PARTNERS THIRD S - /W a. } ®D56%' W \ B-,- (VARIABLE WIDTH PUBLIC g° \ � \ ce-104- I \ \\ 63.2 LF 15" P 40.5O LF 1 RCP �\ B.s LF za RCP / a"BOB °s\ GRADING LEGEND / \\\ CB-209 e ® \ \\ CB-204 s FLARED END SECTION TW=423.25 5 STEM W L ENDWALL SECTION \ Bw=azs_oo -3 _ - (TVP.) - - \ ® ` Q /// 4N n, \ IN \% I II \ -•-' \ \ ,6 \ ♦ CATCH BASIN O `\ 1 / \ �\ ®0.]1� \ \ ♦ DROP INLET Q n TW=423.25 I 21 94 LF 24"RCP � \ \ \\ \ \ ♦ IV BW=423.25 \ ®059% 145.34 LF 24"RCP 27.0, LF 4"RCP S�, \ ■ STORM SERVICE INLET N O \ I I JB-211 I _.3'DRV UTILITY ®0.539, O55% PubSDE r \ \ / _ RETAINING WALLS EASEMENT JB-20] '6 L \ �/ Q \ -Iy� - • STORM SERVICE ROOF-DRAIN � I.J� (DESIGN BY CB'1 \,J. \ \ '0 �(� \ z \ - OTHERS) / RETAINING WALLS 19.0. LF 24"RCP \ .9 `•�'\ °.n `7 ,�\\\ / ®0.5]9, � •7. JUNCTION BOX / Q (,n J (DESIGN BY JB-206 �` e��(Kr. 1 0 N �...____ --_- _ i 89.50 LF 1 BOB LJi `�\\yFFC'9 9' \ 1 DRAINAGE FLOW ARROW � � . 10'PvtSDE OTHERS)I J NOS \ 1\ \ I ®12{7 .. .. 96.98 LF 30"RCP \ \ \ \TC. T °' 1 ti LINE BREAK SYMBOL Q PATIOS F LLC \ TW-424.50 I _\ ©0.559Uj PIN:0649839863 \ \ g \ 250.50 \\ \\ % BW=424.00 II I -FFE=433.00 , 4 \ \ \ 2-.00 TOP&BOTTOM CURB ELEVATIONS z F REID:0266]8] 91.30 LF 24"RCP 10'PvtSDE » \ O ^ Cr ZONING:NMX 'd Y,{ I ®0.55% \ L.L I I I W I 1 i I \ _ I' I ---_-_ BW=4?9.50\ BUILDING I Ii X I - \ \\ \ i /1 �TW=223.00 TOP OF WALL ELEVATION N O v1 9l I -I wll V r BW-213.00 BOTTOM OF WALL ELEVATION > I STEM wALC BUILDING `� o \ b \ z a\ W \% (NOTE:BOTTOM OF WALL IS GROUND / � FFE=424.80 II II I „ I ® \ ) V J v) `p i I ELEVATION NOT WALL FOUNDATION \- \ \ 4 I _ I I ❑ 1 CB 214 B_` \ \ J 1 }250.60 SPOT ELEVATION J g FFTE-435.50 1 N z \1� \\ \ I TW=42200 18.30 LF 12"HD II I / "' \ I 1 \ \` > •� STORM DRAINAGE IJ� O BW=420.50 0 0.60% 10'TYPE'A' " I / ---- ----- ---- - -- Y 1 STORM SERVICE LINE ,�^ = N \ PERIMETER BUFFER-, CB-212 x IW d1.. \ I 1 v' CB-1] 90.00 LF 15"RCP \ �W=428.05 DI-2 -RO-RD-RD- ROOF DRAIN,8"ADS Q 7 m J YI-108 �/ / ®1.5IL \ y TW=435.251 r I[Ell 1 NON-PERFORATED TUBING OR \\ L J 68.10 LF 15"BOB67,9 LF 30"RC 1 \ � - '-- - -- BW=430.00 \S EQUAL 1.0%MIN.SLOPE I MIN. O O I � 32�23 F 15" 21E v v ®220% ` � 0 1 COVER PVC SCHEDULE 401N G rl = DI-111 d .5% / ®0.55% 1 v TRAFFIC AREAS 3201 LF 15"RCP 1 SEGMENTAL BLOCK \ I 1 -TP-TP-TP- TREE PROTECTION FENCE ®078% - ❑ RETAINING WALLS W (DESIGN BY \ I _ LD LD LIMITS OF DISTURBANCE -215 OTHERS) \v) PubSOE 1J`J WOODED AREA a3.88 LF 30"RCP 1 0 0.55% - MAJOR CONTOUR LL n LL W d, ry LLN LL - ----------------- c i �26.87 LF 15"R ® C 124 1 ZSD / � 10'.PO11�m � r � BW=431�901J \� 2 1 252 MINOR CONTOUR YI-213 / ) �) \\\ * ® / 5'TYPE'A' 9r-110 / Dg STEM WALL -\A �A- 1W-43].00 I `B 2 1 2 2 EXISTING MAJOR CONTOUR PERIMETER BUFFER / 1 252 OAR 4 BW-43225 ,1 1� / G \ \� $ I/ / \ \ SEGMENTAL BLOCK / - -------- -------- EASEMENT CONTOUR NE 7T� 7a Of 1 �e / \ (DESIGN BY OTHERS) i� \� =Q� \ �_ _ \ I / RETAINING WALL s RCP __ ®FFE=438.00 1 © (2%MAX.SLOPE IN ALL DIRECrIONS) \'I ACCESSIBLE PARKING AREA 50 = X N/F / \\ PubSDE PUBLIC STORM DRAINAGE EASEMENT 0) \\ PP' NRF REID 03262 XS LLC \\\ \ W �\ ////�'/ 300 NORTH PIN AIN STREET LLC /////// I \ I III III /// at ODETAINI THERS)B WAILS 121.34 LF 30"RCP / PIN:0649839676 'd \\\ ``W" \ / SEGMENTAL$OCK�054% \ r O PvtSDE PRIVATE STORM DRAINAGE EASEMENT �]� uln�� ESO ESO / n m I \\ W \ /\ \\\ \ I^ I _ BE.19113,PG.2570/// i\ ' TOHS-WE TOWN OF HOLLY SPRINGS WATER EASEMENT ^o REID:0326278 C 02 LA \ \ \ TW=44T - � J / / BW=435.00 I w w n n I I IZ STREET A3 ll Ln \II 19ssa LF:15-RCP/ (VARIABLE WIDTH PUBLIC R/VV w SEE SHEET C5.01 IL/I CB-101 CB-209 CB-225 CB-307 JB-205 YI-221 j / v 3'DRY UTILITY C-2 6 1 1 T/C=423.53 T/C=426.22 T/C=436.86 T/C=432.57 RIM=434.25 T/G=435.50 EASEMENT INV IN=413.19(CB-102) INV IN=418.83(JB-211) INV OUT=431.92 INV OUT=427.63 INV IN=42].97(CB-222) INV OUT=432.31 / 29.88 LF 12"HDPE / o on% YI-2v REVISIONS d INV OUT=413.09 INV IN=421.05(CB-210) INV IN=417.29(JB-206) CB-226 CO-227A YI-227 / YI-228 * INV OUT=418.]3 INV OUT=416.69 / CB-10 T/C=438.15 RIM=436.80 T/G=436.65 / 10'TOHS-WE NO, DATE T/C=421.08 CB-210 INV IN=430.16(CB-229) INV IN=433.29(VI-228) JB-206 INV IN=433.07(CO-227A) �____ / I / TVJ-447 25 - INV IN=416.14(CB-106) T/C=426.22 INV IN=432.83(YI-227) INV OUT=433.19 RIM=435.01 INV OUT=432.97 -� 5'TYPE'A' / BW-437.00 i 1 INV IN=414.26(CB-10 INV OUT=421.28 INV OUT=430.06 INV IN=417.50(JB-207) . PERIMETER BUFFER CO-301A INV OUT=417.40 YI-228 _ / /INV OUT=413.41 RIM=431.00 --- CO-227A .3 CB-212 CB-229 T/G=43_Z / 1 CB-103 T/C=425.48 T/C=439.05 INV IN=429.28(CO-301B) JB-207 INV OUT=433.46 T/C=419.60 INV IN=420.54(CB-214) INV IN=433.25(CB-230) INV IN=428.36(CO-301 C) RIM=434.03 / ®0.61% INV IN=414.53(CB-104) INV IN=420.66(VI-213) INV IN=432.33(CB-239) INV IN=428.76(VI-303) INV IN=417.]t (CB-208) YI-302 I /I 24.80 LF 12"HDPE 1 3 INV OUT=414.43 INV OUT=419.56 INV OUT=430.53 INV OUT=428.26 INV OUT=41].61 T/G=432.87 / '�Z/ 0 0,56% u INV OUT=429.68 / 65.65 LF 3 C 1 m CB-104 CB-214 CB-230 CO-301B JB-211 l RIM=a3z.95 RIM=426.25 YI-303 // it \ ®oss% ce-229 SEE SHEET C0.00 FOR ALL PROJECT,SITE, T/c=419so T/c=426.94 T/c=aaas] / ,� INV IN=415.91 (vI-105) INV IN=422.00(JB-235) INV IN=435.88(Co-230A) INV IN=429.58(vI-302) INV IN=419O6(CB-232) T/c=432.05 I / 1 10'P"Ls I 1 GRADING,STORM DRAINAGE AND UTILITY PLAN INFORMATION INV OUT=429.48 INV OUT=418.96 INV OUT=428.86 1, _ INV OUT=414.66 INV OUT=421.90 INV IN=435.53(CB-233) N/F __-- - --- NOTES iNv INV OUT43433.650 5 CB-231) CO-301C JB-215 YI-304 // JPIN 0649933690 / - .4 LF 24"BOB CB-106 CB-216 36.35 LF 15"RC� r RIM=a35.0o RIM=4ze.zo T/c=43z.Os / 0 0.55% /� 1 PROJECT NO. VI522003 n T/C=423.22 T/C=428.8o DB.10098.PG.477 ®o.6% ALL CONSTRUCTION SHALL BE IN ACCORDANCE INV IN OUT=4 8. (VI-304) INV IN==423. (CB-216) INV OUT=428.86 INV IN=418.28(CB-10]) INV IN=423.86(CB-218) CB-231 / ;• 3 INV our=aza.66 INv out=423so / FILENAME VIS22003-CD-G1 INV our=ala.la INv our=423.76 T/c=aao.lz I I I L ca-z1 / \ __ 1 WITH THE CURRENT TOWN OF HOLLY SPRINGS NV IN=434.73(CB-232) DI-Jos vI-10s q 1_-- -- _ r o.z�LF 12"HIDES ENGINEERING DESIGN AND CONSTRUCTION CHECKED BY NDW n CB-107 CB-218 INV OUT=434.63 I / f l -rl _ I CB 230 1 T/C=424.30 T/C=435.11 T/G=423.25 T/G=424.25 63% NV OUT=4.81 (DI-no) INV our=4zOs6 CB-218 STANDARDS DRAWN BY KWH m INV IN=420.60(VI-108) INV IN=429.87(CB-219) CB-232 INV OUT=419.]1 INV IN=419.53(DI-109) INV OUT=429.77 T/C=439.91 VI-108 I / / l / SCALE 1"=30' g INV OUT=419.36 CB-219 INV OUT=434.97 DI-110 T/0=423.90 EOP-100 /I // \ "d / Os 11 11 C "'1 T/c=423.50 INV OUT=420.71 INv=a12.9e ❑ L vI-zz, DATE 07.21.2023 CB-202 T/C=435.01 CB-301 ' ___ S BEET B ` INV OUT=420.06 "'� T/C=435.61 INV IN=430.68(VI-220) T/C=429.54 VI-213 EOP-200 „°- INV IN=415.86(JB-203) INV OUT=430.0] INV IN=428.16(CO-301A) DI-223 T/G=425.25 INV=414.86 / / j / R (�RIABLE WIDTH -- -4 SHEET " INV IN=428.95(CB-243) INV OUT=42].81 T/G=435.20 INV OUT=421.06 / / i -220 62.28 LF 12"H ° INV OUT=415.26 CB-222 EOP-300 PUBLIC R/W) 1 P T/C=435.15 CB-305 INV IN=429.0](CB-224) y1-220 INV=42].66 / I / I^\ ®2.25% NV OUT=428.s7 i SEE SHEET C5.01 - A CB-204 NV IN=428.60(DI-223) T/C=428.32 T/0=434.10 2 6 LF 15 RC 1 NEGRI01NAP83) GRADING AND STORM T/C=434.47 INV OUT=428.50 INV OUT=423.38 EOP-305A I / L___J JB-203 INV IN=430.91 (YI-221) i / ( L " CB-232 -5 2 INV=423A 8 1 s NV IN=4,6.64(JB-205) RIM=435.44 Nv DDT=43D.8, \ DRAINAGE PLAN-AREA'All CB-224 CB-306 INV OUT=416.54 IN IN=416.26(CB-204) EOP-306A _ 6250 LF 15"RCP T/c=43].es T/c=a3o.aa __ _- - 1 GRAPHIC SCALE INV OUT=416.16 EOP-3 7A 4�3M-F 15" CP - BS 0 15 30 c6-208 INv w=429.41 (c6-226) wv our=4zss0 / \ 1 L -INV IN-4;7. INV IN=431.]0(CB-225) EOP-307A / \ ye- /' ®�"v8�\ / 9.99 LF 12"HObEINV IN=417.96(CB-209) INV IN=432.21 (CO-224B) INV=42].48 / sR, / 3.04%INV OUT=417.86 INV OUT=429.31 / \ L / - )inch=30(t. C3e01 SEE SHEET C3.03 FINAL DRAWING-NOT RELEASED FOR CONSTRUCTION / IT v - /F STORMWATER CONTROL / I I I I � V 1 1 cneRIEN P.cHAu, MEASURE"B" / v 1 01 KAM VAN (U,NDERGROUND VAULT) PIN:0649945515 CAST-IN-PLACE / I I I I ) EXISTING 1 1 48.19048,PG.2697 /� TW=442.DD TW-448.00 RETAINING WALL I I I \ TRINIDAD COURT/ TW=446.00 I J i BW=44.5�- BW=441.00 (DESIGN BY OTHERS) I N/F 1 r A Ltr ��o BW=439.00 A RAILSBACtt) I 5j0'P 1 _ / I GARR RAILSBAC� I ( PUBLIC R/W) ( ) '��//l�,■/'� 7,�■a A//�C __� ___, _ PIN:649949172 ,I 1 9 © 1•y\,J y/�j�y\,J DB.1If030,PG.43j The John R.McAdams Company,Inc. S 2905 Meridian Parkway O a o > e e o �E'FAININB WALL) Durham,NC 27713 Ch -__-- DtpT6�1GN BY OTHERS) / / / 1 NCN 1 U / / / I / phone 919.361.5000 ~ 1 / / / / / _ fax 919.361.2269 W ( =446.25 / / // / I license number:C-0293,C-187 Z 1 SEGMENTAL BLOCK �V / V BW=448.00 �/ (n RETAINING WALL - (DESIGN BY OTHERS) I/ / �/ /I www.mcadamsco.com LU LU ��� INDEX MAP Ln 1741 LF 11"RCP CB-255 _ /I 30'TYy['C' / // Ij r--- I-� CLIENT 1 0 0.57% I � PERIM-i" / 1 I BUFFER 1 FOP 300 B-254 4.50 LF 15"RCP // // L-_ VISTA RESIDENTIAL PARTNERS-NC,LLC B-201 ®9 3% I / / / / / I I I I 4000 WESTCHASE BOULEVARD,SUITE 220 _ \ f,, RALEIGH,NORTH CAROUNA,27607 1- 20' bSDE F 36"RCP ( I I // rS J/ I PHONE:919.782.6652 �3 0,54% FFE=448.65 \ 68.95 LF 15 BOB // ARVINDER SINON CHADA, \ / JAGTAR 5904 CHADf( 1 EOP 20b I' \ \ \ / GTAR 59 R CHA / ■ \ __- qr / DB.18632.PG.2516 I- / I / \ - CB-253 / I Iy/F / ♦ / BUILDING \ 1n'PvcsDE _ // // I ANTHOUSTEE,AUB / VISTA RESIDENTIAL ♦ C 2 1 O O55% 24"RCP O \ /�' / / I MARUSTEEAUB / PARTNERS ♦ \ L /° // I� �IDB6595 J1820 55. LF C _-- N!P/ PG.2306 / 101.00 LF 15"RCP / > n n - / GRADING LEGEND ♦ \ \ 43G6s STREET AZ \ ®403" / 0 2.00%,s'BOB CB-243 �s\ (VARIABLE WIDTH PUBLIC R \ I // I� FLARED END SECTION ♦ \ SEE SHEET C5.00 _ os i \__ _______ _____ J_ J \ ------- j-----_L-----. ENDWALL SECTION '^ CB-257 / �DI-258 \\ /// // CATCH BASIN rn Q ♦ i (ilJ 5T LF 0.56%24"RCP 47.07 LF 15"RCP \ / N/F / DROP 1�` `•J I� ♦ S / \ / JA:06 DOS / r Z Q STEM WALL yyI, ®0.57%/ FFE= PIN:o659031 BB] / N \\ (TYPE) T / / 0 TW=448,00 I 442.95 I j\ DB.18305,PG.280 / ■ STORM SERVICE INLET N 0 `� JB-244 CB-2521 / 447.50 / / \ // • STORM SERVILE ROOF-DRAIN = Q CB-256 // oF' FEE- / z ♦� \ \ \ 23.42 LF 2a"RCP '' / I 0 443.45 Y \ / `7 \ ( ® .60% / / \ / O JUNCTION BOX / NQ (n J 443E95 DRAINAGE FLOW ARROW ` Cif `J c FFE= /8Ix \\ /// / - LINE BREAK SYMBOL Z <8.50 F 15"RCP ^3 / _ ®0.7% I 444.45 \ / 250.50 W -- � \\ 250.00 TOP&BOTTOM CURB ELEVATIONS W Z F \� I FFE= \ O \ / 444.95 I // \ \ / �TW=223.00 TOP OF WALL ELEVATION _ ,� Cr I 14.20 LF 12" E / � / \ \ // BW=213.00 BOTTOM OF WALL ELEVATION v I 0 1 (i ®0.63% 44.62 L 1 RB P j / \ \ (NOTE:BOTTOM OF WALLIS GROUND � > z ®o % 5 FFE= \ 10'TOHB-WE J-251 445.45 � I 58.50 LF 24" _ .47 LF/15"RCP I I / \ //\ ELEVATION NOT WALL FOUNDATION) U 1 \ SEGMENTAL Jq��OCK / \ / }250.60 SPOT ELEVATION J 0.57% ��C8-25 7' `6=438.50 RETAINING LL / r\\ (DESIGN THERE) I / / /\ STORM DRAINAGE LL O Ir JB-260 / �CB_24] - _ I,/'� ri / I,/. \\ STORM SERVICE LINE N = N 1 r g4l'o6 LF 15"RCP �� > 000 R ®� RO-RD-RD- 0.56% /,� E I ROOF DRAIN,8"ADS 7=__ v v v I I N/!` // \ - NON-PERFORATED TUBING OR Z M J \T 11.89 LF 12"HOPE ' CB-261 LISA HUE, / \ EQUAL 1.0%MIN.SLOPE TMIN. ®0.59% 20 58 LF 15"R P / BRIAN WH MAN SHUE 10'PvtSDE I \ G \ YI-248 I! ! ®0.58% PINTO 5031810 / 1 \ COVER PVC SCHEDULE G v rl � _ DB.9827,PG.2106/ / TRAFFIC AREAS 1 20.50 LF 1 12"HOPE J-262 17.56 L 5"RCP �'e / / Y II 11 ®0.5]% / / -TP-TP-TP- TREE PROTECTION FENCE 1 STREET A3 ®D.59% ®852`�,2"HOPE f---- -- -- / / / YI-263 44].00 // / LD LO LIMITS OF DISTURBANCE - ) 1 (VARIABLE WIDTH PUBLIC W _-___-_ \ RETAINING WALL �CB-264 B 442.40 �\ 1 SEE SHEET C5.01 DESIGN BY o HERS) WOODED AREA 1 9,06 LF 15"R P 30'TYPE'C' I 2.00% /� PERIMETER BUFFER I 250 MAJOR CONTOUR 11 B zs 1 ZSZ MINORCONTOUR 54.48 LF 15"RCP - ®0.55% I I ___---, ------- ------ EXISTING MAJOR CONTOUR .�pF,,, 26,24 LF 12"HOPE CB 26 I \ -------Z52 CA _____-- EXISTING MINOR CONTOUR O`�........... '(N R ®0.53% \ \ TW=442.50 53.46 LF 15"R P r 1 BW=438.50 0 2,00% 1 FFE= I - - EASEMENT LINE �,,ZO��p \ 1 BUILDING - TW=44sso I 448.05 _ 0.50 LF 15"RCP O BW=444.50 ^\ ACCESSIBLE PARKING AREA 50 ? C 11 \ ®0.54% FFE=438.50 l I 447E55 i l \ (2%MAX.SLOPE IN ALL DIRERIONS) 02. G E 1 \ 16.18 LF 12"HOPE YI-2\ II CB-267 I FFE= \ \ ` PUbSDE PUBLIC STORM DRAINAGE EASEMENT IN JI � P ` 1 II 0.62% \ \ 447.05 \N/F \ 10'PvtSD`E a \i FFE= JOHN LI.BAYUS, \ �/ PvtSDE PRIVATE STORM DRAINAGE EASEMENT �] m CB-201 CB-247 CB-265 YI-235 1 \ \ I ELAINE M,BAYUS \ TOHS-WE TOWN OF HOLLY SPRINGS WATER EASEMENT F, T/C=434.43 T C-437.67 T/C=442.20 T/0=443.75 1 Co 23gB \ ` 1\ 446.56 PIN:0659 1629 / INV IN=415O6(CB-202) V IN=431.23(CB-250) INV IN=437.26(CB-268) INV OUT=439.06 1 \ \ I \ DB.11139,E PG 162 ' INV OUT=414.96 INV IN=433.40(YI-248) INV IN=437.25(CB-z67) O \ \ 8 I INV OUT=430.63 INV IN=433.82 YI-266 YI-240A 1 \ CB-202 INV OUT=333.4] ) T/G=43].60 m 1 \ 60.20 ELF 12"HOPE �.80.80 L 15" CP I 446.05 T/C=435.61 CB-250 INV IN=434.41 (YI-240B) V \ �J 0 0.5674 \ ®0.93% FEE- STEM WALL / INV IN=415.86(JB-203) T/C=438.96 CB-267 INV IN=433.87(CO-239B) 1 ( _ \- \l I 44555 (TYPE) / m INV IN-4z8.95(CB-243) INV OUT=4 1. (JB-251) T/C=44=43 INV OUT=433.52 W 1 I \ 1/ x 4� YI 2a0A T4\\3.50 Tip III �BL268 1 / LU 3 NV OUT 4315.92 TVC N44436.38(CB_253) NVC N684438�01 DI-289) YV�O�T8434.81 LL11 _ T ®258% 1TW A4 980 'I1 ---- --- -- _ _ II-269 I' / m yr BW 438.50 - INV IN 435.10(CB 256) - _ - L _ so ___ ________________®- YI-240B 97.92 LF 15"RCP v CB-229 T/G=437.60 W 1 BW-43 50 I \ INV ouT-a3a.7s �\ / j REVISIONS T/C 43905 CO 239A INV OUT-434.41 VI d INV IN=433.25(CB-230) CB-253 RIM=441.55 y1-246 1 c INV IN=432.33(CB-239) T/C=444.49 INV IN=433.34(YI-240A) 1 SEGMENTAL BLOCK / / INV OUT=433.24 T/G=435.90 N RETAINING WALL N0. DATE INV OUT=430.53 INV IN=439.55(CB-254) SEGMENTAL BLOCK INV OUT=432.21 FFE=440.50 ^' INV OUT=439.45 \(DESIGN BY OTHE S) RETAINING WALL I / CB CO-2398 m T/C=440.57 CB-254 RIM=438.00 YI-248 1 65.65 LF 30'RCP ) ( (DESIGN BY OTHERS) INV IN=435.88(CO-230A) T/C=445.29 INV IN=434.31 (YI-241) T/G=43].25 1 1 T=442.00 INV IN=433.57 ®O56% (� CB-242 B-438.50 I / INV IN=435.63(CB-233) INV IN=440.35(CB-255) INV OUT=434.21 (YI-249) 10'PvISDE � / \ / INV IN=434.50(CB-231) INV OUT=433.47 INV OUT=440.25 DI-258 I \ o INV OUT=433.65 T G=442.50 YI-249 1 CO-23 18.8 LF 15"H E d II II I / GB-255 /- STREET B u' CB-231 T/C=446.07 INV OUT=437.56 T/G=43].38 1 CB-229 ®0.59% / = /c=aao.lz INV our=aao.n INV OUT=433.69DI-269 1 --� (VARIABLE WIDTH PUBLIC R/W) N/F SEE SHEET CO.00 FOR ALL PROJECT,SITE, INV IN=434.73(CB-232) YI-263 / WINDWARD POINTE HOA INC. INV our=a34.63 c6-zss VG=444.7s I SEE SHEET C5.01 I PIN:065903421 GRADING,STORM DRAINAGE AND UTILITY PLAN INFORMATION T/C=440.48 INV OUT=439.81 T/G=437.15 CB-CB DB.6637,PG.237 INV OUT=433.96 1 `o CB-233 INV IN=435.26(CB-257) JB_244 p8e./ / I NOTES .V T/C=442.03 INV OUT=435.16 RIM=437.08 YI-266 PROJECT NO. V$22003 NV IN=437.09(DI-234) CB-257 INv IN=430.06(CB-245) T/G=437A5 1 a3.14 LF 18"RCP 78.39 LF 1r IjCP / I \ ALL CONSTRUCTION SHALL BE IN ACCORDANCE INV OUT=436.99 INV OUT=429.96 INV OUT=433.96 ®0.54% 0 3.66% g T/C=440.57 F L WITH THE CURRENT TOWN OF HOLLY SPRINGS FILENAME VIS22003-CD-G1 CB-239 INV IN=435.63(DI-258) JB-251 1 ]1.46 LF 24"RCP - T/C=440.38 INv OUT=435.53 RIM=440.06 EOP-200 / I ENGINEERING DESIGN AND CONSTRUCTION CHECKED BY NDW INV IN=435.44(CB-242) INV IN=434.49(CB-252) INV=414.86 1 1.73 LF 15"RCP ®0.56% / STANDARDS CB / L-- - DRAWN BY KWH 0.58% i INV IN=433.13(CO-239A) INV IN=432.40(JB-260) - O° INV OUT=432.78 T/C=443.61 INV IN=435.12(CB-259) EOP-300 1 / / YI-235 INV OUT=436.]t INV=42].66 / I I SCALE 1"-30' INV OUT=432.05 1 CB-242 CB-261 0 2.1 LF 15"RCP / T/G=443.25 JB-260 1 ®2.18% / DATE 07.21.2023 i INV OUT=438.31 T/C=441.46 RIM=441.05 1 o INV IN=432.97(JB-262) INV IN=432.75(CB-261) CB-233 CB-243 INV OUT=432.87 CB-2 PERIMETER BUFFER BLUEFIN DEVELOPERS LLC. I \ SHEET INV OUT=432.65 1 �. / \ 5'TYPE'A' 2 T/C==429+ VC=44 1 u INV IN=4z9.54 GB-244) INV OUT=43 JB-262 1 9. LF 15"RCP N/F \ / NCGRID(NAD83) NV DDT=az9.aa INV our=a37.z, RIM=441.17 _ ________________ ® �% \ GRADING AND STORM INV IN=433.17(CB-265) B 23 22.76 LF 15"RCP � 6].15 LF 12"HOPE pIN:0649939489 \ / $ CB-245 INV IN=436.23(CB-264) 1 0 0.57% I 0 0.55% DIE 15265,PG.2034 \ / DRAINAGE PLAN-AREA FFBLL N T/C=437.67 INV IN=433.83 YI-263 / BM.2013,PG.560 INV IN=430.30 CB-247 - - - - >`-'� I \ GRAPHIC SCALE INV OUT=433.0] ) 1 1!I'TOHS- / INV IN=432.12(YI-246) 1 1 0 3 12'-HOPE 10'PvtSDE__ / / INV OUT=430.20 , U 15 30 C3e02 _ so SEE SHEET C3.03 FINAL DRAWING-NOT RELEASED FOR CONSTRUCTION 1 1 MCADAMS The John R.McAdams Company,Inc. �-- 2905 Meridian Parkway ' 11C11 ' Durham,NC 27713 phone 919.361.5000 - - fax 919.361.2269 license number:C-0293,C-187 INDEX MAP www.mcadamsco.com CLIENT VISTA RESIDENTIAL PARTNERS-INC,LLC 4000 WESTCHASE BOULEVARD,SUITE 220 RALEIGH,NORTH CAROLINA,27607 PHONE:919.782.6652 Nft VISTA RESIDENTIAL PARTNERS I SEE SHEET C3.01_ _ I SEE SHEEN C3.02 -----------------------I -- - - -ILI cu=23-3-----1 --- �1 5 TYPE A C-2 1 / PERIMETER BUFFER N/F \ GRADING LEGEND ��\ a 1 �\15"RCP 7.15 LF 12"HOPE BLUEFIN DEVELOPERS LLC. \ 62.50 LF 15"RCP \ 0.55% PIN:0649939489 I \ FLARED END SECTION 0 2.18% / / DB.15265,PG.2034 \ \ �� 1d'TONS- BM.2013,PG.560 \ 1.3 LF 15 RCP 69.99 LF 12"yDPE / / I \ ENDWALLSECrION CB-2 587 I ®3.04 ° 10'P1sDE- ` Ln 2 76 LF 15 RCP \\ CATCH BASIN r n Q / 7- 1 T/C=440.57 DROP INLET z Q I" CB-2 0 DI-234 V IN_ (CO_ /A \ \ BEWER TONS �� W -----� INV IN=435.63(CB-233)) V/ O N SANITARY - 1\/ ■ STORM SERVICE INLET EASEMENT 1W=443.00 TW=446.85 TY=44600 I 22.94 LF 12"HOPE INV IN=434.50(CB-231) a \ \ i BW=443.00 BW=444.00 BW=44.00 \ I 0 6.10% I INV OUT=433.65 • STORM SERVICE ROOF-DRAIN `7 I.J� z \ I w I I CB-231 O JUNCTION BOX / Q (,n J �•R CO-230A/ TW=447.00 T/C=440.12 NN Q BW=446.85 I INV IN=434.]3(CB-232) - DRAINAGE FLOW ARROW I..L l/\ / -� S I I INV OUT=434.63 �.. LINE BREAK SYMBOL _ -------- Z a I/I - { CB-2 W v II II SEGMENTAL BLOCK Y_ ® I I T/C=439.91 250.50 TOP BOTTOM CURB ELEVATIONS W ^ F STREET A3 RETAINING WALLS I� I INV OUT=434.97 250.00 Z CC y (DESIGN BY OTHERS) S'ytI ENTAL BLOCK I CB-233 I.- =46.eo (VARIABLE WIDTH PUBLIC R/W) SE/WING WALLS I �TW=223.00 TOP OF WALL ELEVATION _O , ) P B=445.50 DE ION BY OTHERS I / T/C=442.03 BW=213.00 BOTTOM OF WALL ELEVATION v I 0 III SEE SHEETC5.01 I NV OUT=436.99 (NEOTE:OTTO OFWALLISGR UN) ~ z IN IN=2303 (DI-234) WALL �I ND BUILDING \ 85.4 12"HERE- SEGMENTAL BLOCK / r--r _l _ -L I CO-230A ,A U _j N T97% RETAINING WALLS O v I 6 RIM=442.]0 J I DESIGN BY OTHERS) FFE=447.DO / I INV IN=439.51 (CO-230B) +250.60 SPOT ELEVATION z / TW=448.001 / INV OUT=438.01 Z O / TK' / BW=446.8�' / I � STORM DRAINAGE � - 10-TWE,A, - - � I CO-230B - STORM SERVICE LINE � = d TW=44].00\ / RIM=446.30 N 1 =446.75 PERIMETER BUFFER / INV IN=441.29(VI-237) _ =4 5.00 Tw=447.50 / 48.54 LF-11e HDPE Bw=446.85\ `a-' r INV OUT=441.19 ROOF DRAIN,8"ADS N A \ BW=447.GO 0 0.56% - / a \ PROPOSED ROAD IMIVROVEMENTSI � -RD-RD-RD- NON-PERFORATED TUBING OR � Z ' ` J 110 / Yi-237 20.13 LF 12"HOPE YI-23� EX.10'PRIVAATE SANITA�jY FROM OTHERS(PART OF CO-230C M J B --� ®0.55% CO-230D SEWER EASEMENT TOWN/NCDOT HOLLY SPRINGS RIM=446.95 EQUAL 1.0%MIN.SLOPE 3'MIN. G O O = 6.60 B.M.2013,PG\560 ROrAD WIDENING PROJECT) I / INV IN=441.70(CO-230D) COVER PVC SCHEDULE 401N G U r-I = �' TW=448.00 INV OUT=441.60 TRAFFIC AREAS e=4146,10 BW 4 7.00 ,\ \ I L CO-230D -TP-TP-TP- TREE PROTECTION FENCE _ 0-230B --- - - - -- _CO-23OE // ®ORry RIM=446.95 --- _ - =q 5 LF 12' HIRE _- I T I� INV IN=441.95(CO-230E) LD TO LIMITS OF DISTURBANCE - Q- OC BW= .85 0.57 __- INV OUT=441.85 __ ur-¢r - � yr--ter-- ro � - J� -230E WOODED AREA -------___ �_-� RIM=446.95 INV IN=442.32 17.11 L 1 - 17€ SEGMENTAL BLOCK \ ro ro- 1p Fo A ------ - INV OUT=44222 2 250 MAJOR CONTOUR _ ___ 38) A„A w�w w urv®-.p58Z, yrv,�$EINGW VARIABLE WID 1Tro ro�ro� - - 252 MINOR CONTOUR w rwf''^' RIGHT-OF-WAY \ T/G-4 T/G=444.35 _______25g_______ EXISTING MAJOR CONTOUR ,4��ru o ¢ c ¢ c c ° qry c4ry �cery w ry M INV IN=440.66(VI-236) ss INV IN=438.69(VI-235) 252 ------ EX15TING MINOR CONTOUR 0�4,'(Y`` OAR" ------ .,r5a ___________ p` ---- INV OUT=438.34 / r I YI-236 - - EASEMENT LINE s T/G=445.25 Q INV OUT=442.06 i JACC E NGAREA 0 YI-237 (2%MAX.SLOPE IN ALL DIRERONS) _ O - -- _----"--_- ----- T/G=4458 -ram._„ -sue==u°ss ? INv IN=441.49(Co-230C) LINE ¢u- - s ss PubSDE PUBLIC STORM DRAINAGE EASEMENT pAp Ou �_ ss INV OUT=441.39 YI-238 PVtSDE PRIVATE STORM DRAINAGE EASEMENT 70 INV OU45442.51 TOHS-WE TOWN OF HOLLY SPRINGS WATER EASEMENT ro EXISTING /F (VARIABLE WIDTH PU LIC R/W) I � / I FT - I --- I I I EXISTING J <-T--J - _R�LL�1G�STRE-ET- N �\ - (VARIABLE-WIDTH PUBLIC R/W) >I v REVISIONS a N0. DATE 3 SEE SHEET CO.00 FOR ALL PROJECT,SITE, 3 GRADING,STORM DRAINAGE AND UTILITY PLAN INFORMATION NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE PROJECT NO. VI522003 8 WITH THE CURRENT TOWN OF HOLLY SPRINGS FILENAME VIS22003-CD-G1 ENGINEERING DESIGN AND CONSTRUCTION CHECKED BY Now STANDARDS DRAWN BY KWH SCALE 1"=30' DATE 07.21.2023 Qwl SHEET NCGRID(NAD83) GRADING AND STORM s DRAINAGE PLAN-AREA"C" GRAPHIC SCALE 0 60 I i C3e03 inch=30 rt. FINAL DRAWING-NOT RELEASED FOR CONSTRUCTION LEGEND EXISTING WETLANDS + + + + + + + + PERMANENT WETLAND + + + + + + + + IMPACT F'o o + + \ + \ cl\ u + 1 y / -v GI + �\ DEDI EATEg /,0+ WETLANDS LIMITS \ DISTUf�B'F CE \ I / \ \ � L() + + + UD + 0 w 416 . . . . + + + + + + / T o s\ + + + + + + + o + + + + x + T n U) + + o + - + 0 0 T RE "A"o v o - OJ T T o CIA U') � o \ 1 T u) . EXISTING Al PERMANENT THIRD STREET WETLAND IMPACT 4,084 SF (VARIABLE WIDTH PUBLIC R/W) (0.094 AC) N NC GRID(NAD83) GRAPHIC SCALE 0 15 30 60 mini 1 inch=30 ft. M:\Projects\VIS\VIS22003\04-Production\En ineerin\Exhibits\Im act Ma s\VIS22003-E1.dw,6/15/202310:44:49 AM,Kevin Hughes !! The John R.McAdams Company,Inc. PLAN INFORMATION 2905 Meridian Parkway MAIN STREET VISTA Durham,NC 27713 PROJECT NO. VIS22003 FILENAME VIS22003-El phone 919.361.5000 WETLAND IMPACTS CHECKED BY NDW fax 919.361.2269 137 HOLLY SPRINGS ROAD DRAWN BY KWH license number:C-0293,C-187 SCALE 1"=30' MCADAMS www.mr.adamsco.com HOLLY SPRINGS, NORTH CAROLINA, 27540 DATE 06.15.2023 Simpson, Richard From: Rachel Jones <rachel Jones@hollyspringsnc.gov> Sent: Thursday, January 4, 2024 4:54 PM To: Simpson, Richard Cc: Rachel Ingham; Koncz, Emily; Wild, Elaine; Nick Williamson; Kendra Parrish Subject: RE: --[EXTERNAL]--NC-55 Roadway Improvements Sewer Extension 2nd Additional Information Request Attachments: NC-55 Roadway Imp Sewer Ex_Attachment_010424.pdf Follow Up Flag: Flag for follow up Flag Status: Flagged CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Hello Richard, Happy new year! We appreciate your feedback on this application. Please see our responses below and the associated attachment. 1—Please confirm the 80 GPM pump station with duplex pumps, standby power, and approximately 7,399 linear feet of 4-inch force main is still operational per the existing permit. Section VIII.3. of the Fast Track Application list 2 pumps but Section VIII.5. notes only the 22 GPM pump. An updated Page 3 of 5 for the Fast Track Application is needed. We believe the Fast Track permit application to be completed correctly and not need revision based on the following information: Section V111.3 lists 2 pumps—the 22 GPM pump station has duplex pumps at that pump station. Section V111.4 notes only the 22 GPM pump station—the 80 GPM pump station and 7,399 LF of 4-inch FM that was permitted with WQ003304 on November 16, 1995 is no longer operational. We would like to take this opportunity to remove it from the permit. 2—The current permit has a 22 GPM pump station with duplex pumps, standby power, and approximately 2,086 linear feet of 2-inch force main. In Section VIII.S. of the Fast Track Application,the 22 GPM has a 4-inch force main. If it is a fl- inch, has it been certified with a previous modification? Please explain. To the best of our knowledge, WQ003304 was originally permitted on May 10, 1991 and showed the 4-inch force main as part of the original Easton Acres Sanitary Sewer Improvement Project(as-builts date February 1992). Modification of permit WQ003304 occurred on November of 1995. Between 1995 and 2023, there do not appear to be further modifications. "NOTE.Please see attachment from the 1992 As-Built Drawings. The Easton Acres Pump Station(Pump Station#1) and associated 4-inch force main are highlighted in orange and clouded for clarity. 1 NLGS Rachel Jones, El I Utility Engineer Town of Holly Springs I Utilities & Infrastructure Services PO Box 8 1 128 S Main St I Holly Springs, NC 27540 }� Main: (919) 577-3156 1 Cell (919)-980-2992 vs��o www.hollyssprin snc.gov North From: Simpson, Richard<richard.simpson@deq.nc.gov> Sent: Wednesday,January 3, 2024 2:55 PM To: Nick Williamson <williamson@mcadamsco.com>; Kendra Parrish <kendra.parrish@hollyspringsnc.gov> Cc: Rachel Ingham <rachel.ingham@hollyspringsnc.gov>; Emily Koncz<emily.koncz@hollyspringsnc.gov>; Wild, Elaine <elaine.wild@deq.nc.gov>; Simpson, Richard <richard.simpson@deq.nc.gov> Subject: --[EXTERNAL]--NC-55 Roadway Improvements Sewer Extension 2nd Additional Information Request Hello Kendra and Nick, After reviewing the Fast Track Sewer System Extension Application for NC-55 Roadway Improvements Sewer Extension —Modification (Application Number WQ0003304), additional information is required in order to further process the application. Please provide the following information by February 2,2024, and note that the requested information must be submitted within 30 days of this request, or the applicant will be required to submit a new application and application fee in accordance with 15A NCAC 02T.0107. 1—Please confirm the 80 GPM pump station with duplex pumps, standby power, and approximately 7,399 linear feet of 4-inch force main is still operational per the existing permit. Section VIII.3. of the Fast Track Application list 2 pumps but Section VIII.5. notes only the 22 GPM pump. An updated Page 3 of 5 for the Fast Track Application is needed. 2—The current permit has a 22 GPM pump station with duplex pumps, standby power, and approximately 2,086 linear feet of 2-inch force main. In Section VIII.5. of the Fast Track Application,the 22 GPM has a 4-inch force main. If it is a fl- inch, has it been certified with a previous modification? Please explain. 15A NCAC 02T.0107 Staff Review and Permit Preparation states: "(2) (e) If an application is accepted and later found to be incomplete,the applicant shall be advised how the application or accompanying supporting information may be modified to make it complete.The staff shall advise the applicant: (2) if all required information is not submitted within 30 days,the project will be returned as incomplete. Any resubmittal of a returned application shall be accompanied with a new application fee." Please contact me with any questions that you may have regarding this request. *Please note that the fee for fast track sewer extension permits has increased to$600 as of October 3,2023(as stipulated in the 2023 House Appropriations Act, House Bill 259, Water Quality and Stormwater Fees,Section 12.14(a)). Sincerely, Richard From: Nick Williamson <williamson@mcadamsco.com> Sent:Tuesday, December 19, 2023 2:43 PM To: Simpson, Richard<richard.simpson@deg.nc.gov>; Kendra Parrish <kendra.parrish@hollyspringsnc.gov> Cc: Rachel Ingham <rachel.ingham@hollysprinesnc.gov>; Koncz, Emily<emily.koncz@hollyspringsnc.gov>;Wild, Elaine <elaine.wild@deg.nc.gov> Subject: [External] RE: NC-55 Roadway Improvements Sewer Extension Additional Information Request 2 CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Please see the attached 404 permit for this project. There are no buffer impacts that would require a 401 permit. Thanks, Nick Nick Williamson PE Project Manager MCADAMS mobile 919.948.8064 williamson@mcadamsco.com 2905 Meridian Parkway Durham,NC 27713 www.mcadamsco.com Join Our Team From: Simpson, Richard <richard.simpson@deg.nc.gov> Sent: Friday, December 15, 2023 1:30 PM To: Kendra Parrish <kendra.parrish@hollyspringsnc.gov> Cc: Rachel Ingham <rachel.ingham@hollyspringsnc.gov>; Nick Williamson<williamson@mcadamsco.com>; Koncz, Emily <emily.koncz@hollyspringsnc.gov>; Simpson, Richard <richard.simpson@deg.nc.Rov>;Wild, Elaine <elaine.wild@deg.nc.gov> Subject: NC-55 Roadway Improvements Sewer Extension Additional Information Request I You don't often get email from richard.simpson@deg.nc.sov. Learn why this is important CAUTION:This email is NOT from McAdams. DO NOT click links or open attachments unless you verify the sender and content. Hello Kendra and Nick, After reviewing the Fast Track Sewer System Extension Application for NC-55 Roadway Improvements Sewer Extension —Modification (Application Number WQ0003304), additional information is required in order to further process the application. Please provide the following information by January 14, 2024, and note that the requested information must be submitted within 30 days of this request, or the applicant will be required to submit a new application and application fee in accordance with 15A NCAC 02T.0107. 1—Please provide the Permit Number/Permitting Status letter for the 404/401 authorization specified in Section IX.5. of the Fast Track Application. 15A NCAC 02T.0107 Staff Review and Permit Preparation states: "(2) (e) If an application is accepted and later found to be incomplete,the applicant shall be advised how the application or accompanying supporting information may be modified to make it complete.The staff shall advise the applicant: (2) if all required information is not submitted within 30 days,the project will be returned as incomplete. Any resubmittal of a returned application shall be accompanied with a new application fee." Please contact me with any questions that you may have regarding this request. 3 *Please note that the fee for fast track sewer extension permits has increased to$600 as of October 3,2023[as stipulated in the 2023 House Appropriations Act, House Bill 259, Water Quality and Stormwater Fees, Section 12.14(a)]. Sincerely, Richard Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. This email originated • outside of organization. 1 • not click links or open attachments unless you • •nize the sender and know the content Warning:This email is subject to disclosure under the North Carolina Public Records Law(NCGS 132-1). 4 �SANI:TARY SEWER IMPROVEMENTS � TO SERVE EASTON ACRES' m Q D TOWN OF HOLLY SPRINGS cn cn NORTH CAROLINA _ c CD MAYOR - GERALD HOLLEMAN „ 3 COMMSSIONER WILLIAM J. BANKS COMMISSIONER - JOHNNY McNEIL CD COMMISSIONER - PARRISH WOMBLE N COMMISSIONER - OTIS BYRD COMMISSIONER - EDISON PERKINS SITE 1 S 12655) V -Zf-9p BUILT 13 FEB. 92 BGL REVISED 24 JAN. 91 BGL o11r0—.ems HOBBS■ UPCHURCH & ASSOCIATES, P. A., AmJ �;? CONSULTING ENGINEERS � i VICINITY MAP SOUTHERN PINES , NORTH CARO-LINA m w 0 Z3 D c� _. m (n W m (D 0 m m 55 Z3 (n S-11 EXISTING PUMP STATION, GRAVITY SEWER & FORCE MAIN ✓ EXISTING GRAVITY SEWER (D ---- ---� ----_-_----- W FM-3 N S-II t— S-12 PROPOSED 4" FORCE MAIN I) N.C.HWY 55 FM-2 ALTERNATE -- ------------- -- -- ----- -3 --------- - - - -- --- - - - -- -- EXISTING MANHOLE S_g I S-1 S PROPOSED 4" FORCE+ MAIN - PROPOSE GRAVITY SEWER - - - S_ - - - S-3 FM-2 ALTERNATE I I M-1 I S-2 �+ S 10 S-1 - _. PROPOSED 4" FORCE MAI �FM-1 S-7 UMP STATION-#2 ALTERNATE - - - - S-6 - - PUMP STATION #1 LAYOUT MAP NTS AS-BUILT 13 FEB. 92 BGL REVISED 24 JAN. 91 BGL onrE HOBBS, UPCHURCH & ASSOCIATES, P.A. MAR.14,1990 CONSULTING ENGINEERS DESIGNED - SOUTHERN PINES,.NORTH CAROLINA 28387 JWM - - DRAWN: SEWER IMPROVEMENTS JL" HECKS c`�an•CA„ � i ,Jco�SO—RO��'� C Z/"' DT III -z •pffSSfp.1 TO SERVE `e� _ EASTON ACRES TC—ALE o 12655 � ` - SHEET NO. LAYOUT MAP 2 g_2,f0 ALTERNATE D 26 Simpson, Richard From: Wild, Elaine Sent: Friday, December 15, 2023 11:37 AM To: Marcos Vidal Cc: Jones, Rachel; Rachel Ingham; Kendra Parrish;williamson@mcadamsco.com; Koncz, Emily; Simpson, Richard Subject: RE: [External] WQ0044787 Ver A - Main Street Vista HI Marcos, Application reviews are currently taking 5-8 weeks for permits to be reviewed/issued from date of receipt, provided all required documentation is submitted to the Division and applications are considered complete according to the Application Instructions. Thank you, Elaine Wild Environmental Engineer Division of Water Resources- Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild@deq.nc.gov R E Q: pportmlwl of tnwromenW Oual� Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Sewer Extension Permitting I NC DEQ subchapter t rules.pdf(state.nc.us) From: Marcos Vidal <mv@vistarp.com> Sent: Friday, December 15, 2023 10:55 AM To:Wild, Elaine<elaine.wild@deq.nc.gov> Subject: RE: [External] WQ0044787 Ver A- Main Street Vista CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Thank you, Elaine. For my edification, and that of our investors.What is a typical timeframe to review the two applications? I'm trying to map this out internally as we have many stakeholders that want to know when we'll have all our approvals. From:Wild, Elaine<elaine.wild@deg.nc.gov> Sent: Friday, December 15, 2023 10:47 AM To: Marcos Vidal <mv@vistarp.com> Subject: RE: [External] WQ0044787 Ver A- Main Street Vista Hello Marcos, Please see the attached update email sent to the Town of Holly Springs and the consultant. Thank you, Elaine Wild Environmental Engineer Division of Water Resources- Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild@deg.nc.gov a tmma�ir owi,� Email correspondence to and from this address is subject to the North Carolina Public Records Lave and may be disclosed to third parties. Sewer Extension Permitting I NC DEQ subchapter t rules.pdf(state.nc.us) From: Marcos Vidal <mv@vistarp.com> Sent: Friday, December 15, 2023 9:49 AM To:Wild, Elaine<elaine.wildelaine.wild@deg.ncgov> Subject: RE: [External] WQ0044787 Ver A- Main Street Vista CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Good morning, Elaine, I checked the online portal, noticed it still shows as waiting on a resubmittal. I know there's been a lot of back and forth between Holly Springs and yourself. I wanted to ask if there were more questions you need answered. I appreciate it. Thanks, Marcos Marcos Vidal Development Manager-Carolinas Vista Residential Partners 2 4000 Westchase Blvd, Suite 220 Raleigh, NC 27607 off: (919) 782-6652 x103 cell: (305) 297-1223 ft ISTA RESIDENTIA1, 11\R1\1 Rs From: Wild, Elaine<elaine.wild@deg.nc.gov> Sent:Tuesday, November 28, 2023 12:35 PM To: Marcos Vidal <mv@vistarp.com> Cc: Kendra Parrish <kendra.parrish@hollyspringsnc.gov>;Alex Barroso<ab@vistarp.com>; Nick Williamson <williamson@mcadamsco.com> Subject: RE: [External] WQ0044787 Ver A- Main Street Vista Hello Marcos, I have received several items for the Main Street Vista project. I will reach out if I have any further questions or comments after I have reviewed all items submitted. Thank you, Elaine Wild Environmental Engineer Division of Water Resources- Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild@deg.nc.gov Ueyartmenl of f nnroMMnill QYI� Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Sewer Extension Permitting I NC DEQ subchapter t rules.pdf(state.nc.us) From: Marcos Vidal <mv@vistarp.com> Sent:Tuesday, November 28, 2023 9:47 AM To: Wild, Elaine<elaine.wild@deg.nc.gov> Cc: Kendra Parrish <kendra.parrish@hollyspringsnc.gov>;Alex Barroso<ab@vistarp.com>; Nick Williamson <williamson@mcadamsco.com> Subject: RE: [External] WQ0044787 Ver A- Main Street Vista 3 CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Good morning, Elaine, I understand that The Town of Holly Springs sent additional info last Tuesday(11/21/23)—I wanted to check in to make sure it was received since the application tracker still shows NCDEQ as waiting: Current Status: In review Application #: WQ0044787 Ver A Application Schedule: Application Type: New Project Application/Permit#: WQ0044787 Ver A Application Signed By: Kendra D. Parrish Program Category: Collection Systems Permit Class: Individual Project Type: New Project Is Fast Track? Yes Primary Reviewer: Elaine Wild Status Updated: 2023-10-02 Application Received: 2023-10-02 Application Reviewed: 2023-10-24 Last Add'I Info Requested: 2023-10-24 Last Add'I Info Received: Total Add Infos Requested: 1 Total Days Waiting for Add Info: 34 Issued Date: Zoom to Thanks, Marcos Vidal Development Manager-Carolinas Vista Residential Partners 4000 Westchase Blvd, Suite 220 Raleigh, NC 27607 off: (919) 782-6652 x103 cell: (305) 297-1223 Nft VISTA RI-:SII)FV"I'IAL 4 From: Marcos Vidal Sent:Thursday, November 2, 2023 12:07 PM To: 'Wild, Elaine' <elaine.wild@deg.nc.gov> Cc: Kendra Parrish <kendra.parrish@hollyspringsnc.gov>;Alex Barroso<ab@vistarp.com>; Nick Williamson <williamson@mcadamsco.com> Subject: RE: [External] WQ0044787 Ver A- Main Street Vista Hi Elaine, I see you requested additional information on 10/24—could you please share those comments with me? I assume they are routed through the Town (but we have not received comments through the Town yet) and I'd like to have our engineer address asap. Current Status: In review Application#:WQ0044787 VerA Application Schedule: Application Type: New Project Application/Permit#:WO0044787 Ver A Application Signed By: Kendra D.Parrish Program Category: Collection Systems Permit Class: Individual Project Type: New Project Is Fast Track? Yes Primary Reviewer: Elaine Wild Status Updated:2023-10-02 Application Received: 2023-10-02 Application Reviewed: 2023-10-24 LastAdd'I Info Requested: 2023-10-24 LastAdd'I Info Received: Total Add Infos Requested: 1 Total Days Waiting for Add Info: 8 Issued Date: Zoom to ••• Thanks, Marcos Vidal Development Manager-Carolinas Vista Residential Partners 4000 Westchase Blvd, Suite 220 Raleigh, NC 27607 off: (919) 782-6652 x103 cell: (305) 297-1223 T VISTA A RESIDENTIAL IAL P.ARTVFRS 5 From: Marcos Vidal Sent: Monday, October 23, 2023 3:32 PM To: 'Wild, Elaine'<elaine.wild@deg.nc.Pov> Cc: Manuel,Vanessa<vanessa.manuel@deg.nc.gov>; kendraparrish@hollyspringsnc.us; williamson@mcadamsco.com; Alex Barroso<ab@vistarp.com> Subject: RE: [External] WQ0044787 Ver A- Main Street Vista Thank you, Elaine. From: Wild, Elaine<elaine.wild@deg.nc.gov> Sent: Monday, October 23, 2023 3:25 PM To: kendraparrish@hollysprinPsnc.us; williamson@mcadamsco.com; Marcos Vidal <mv@vistarp.com> Cc: Manuel,Vanessa<vanessa.manuel@deg.nc.gov> Subject: RE: [External] WQ0044787 Ver A- Main Street Vista Hello Kendra, Nick, and Marcos, Thank you for reaching out. The Division is currently reviewing the application for the Main Street Vista Sewer Extension project,that was received on October 2, 2023. Application reviews are currently taking 5-8 weeks for permits to be reviewed/issued from date of receipt, provided all required documentation is submitted to the Division and applications are considered complete according to the Application Instructions. If you have any further questions or concerns regarding this application, please contact feel free to reach out to me. Thank you, Elaine Wlld Environmental Engineer Division of Water Resources- Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild@deg.nc.gov D_EQ A rto,t-'-w , Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Sewer Extension Permitting I NC DEQ subchapter t rules.pdf(state.nc.us) From: Manuel,Vanessa<vanessa.manuel@deg.nc.gov> Sent: Monday, October 23, 2023 2:53 PM To:Wild, Elaine<elaine.wild@deg.nc.gov> Subject: FW: [External] WQ0044787 Ver A- Main Street Vista Please see and respond to the email below. Thanks. 6 Vanessa E. Manuel Assistant Regional Supervisor Division of Water Resources— Raleigh Regional Office Department of Environmental Quality 919 791-4232 Office; 919 817-1256 Mobile vanessa.manuel(L-D eg.nc.gov Physical: 3800 Barrett Drive, Raleigh, NC 27609 Mailing: 1628 Mail Service Center, Raleigh, NC 27699-1628 Note: DEQ is updating its email addresses to @deg.nc.gov in phases from May 1'to June 9`h Employee email addresses may look different, but email performance will not be impacted. Xz_ !' 'Nothing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Marcos Vidal <mv@vistarp.com> Sent: Monday, October 23, 2023 2:33 PM To: Manuel,Vanessa<vanessa.manuel@deg.nc.gov> Subject: [External] WQ0044787 Ver A- Main Street Vista CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Hi,Vanessa, I'm the developer for Main Street Vista—a new project located in Town of Holly Springs with Sewer Permit fast track application#WQ0044787 Ver A. I wanted to ask what your typical review duration is and whether fast track applications typically go through 1 or 2 review cycles? I appreciate any info! Thanks, Marcos Vidal Development Manager-Carolinas Vista Residential Partners 4000 Westchase Blvd, Suite 220 Raleigh, NC 27607 off: (919) 782-6652 x103 cell: (305) 297-1223 7 Nft VISTA RESIDENTIAL PARTNERS Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. 8