Loading...
HomeMy WebLinkAboutWM0100564_Monitoring Well Construction Application_20230816FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: August 16, 2023 2. County: Henderson 3.What type of well are you applying for? (Monitoring or recovery): Monitoring 4. Applicant: Tiffany Bauman on behalf of ExxonMobil Telephone: 346.268.0985 Applicant’s Mailing Address: 22777 Springwoods Village Pky. Spring, TX 77389 Applicant’s Email Address (if available): tiffany.n.bauman@exxonmobil.com 5. Contact Person (if different than Applicant): Jeremy Blumberg Telephone: 508.270.6574 Contact Person’s Mailing Address: 1 Beacon Street, Suite 8100, Boston, MA 02108 Contact Person’s Email Address (if available): JBlumberg@Kleinfelder.com 6. Property Owner (if different than Applicant): Duane and Margaret McKibbin Family LTD PRTNR Telephone: Property Owner’s Mailing Address: 745 Ashe Street, Hendersonville, NC 28792 Property Owner’s Email Address (if available): mckibbin@hendersonoil.com 7. Property Physical Address (Including PIN Number) 9579259550 City Hendersonville County Henderson Zip Code 28792 8. Reason for Well(s): Assessment (ex: non-discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: Active retail petroleum (ex: non-discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). Incident #9644 11. Type of contaminants being monitored or recovered:Organics (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? Ten monitoring wells Existing Monitoring or Recovery Well Construction Permit No(s).: Unknown 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): Between 50-100 feet 14. Are there any water supply wells located less than 500 feet from the proposed well(s)?No If yes, give distance(s): 15. Well Contractor:SAEDACCO Certification No.: Well Contractor Address: 9088 Northfield Drive, Fort Mill, SC 29707 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse WM0100564 12/7/2023 PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated material: Two 3. Number of wells to be constructed in bedrock: 4. Total Number of wells to be constructed: Two (add answers from 2 and 3) 5. How will the well(s) be secured? cap and metal cover 6. Estimated beginning construction date: 9/26 7. Estimated construction completion date: 9/28 ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant assumes total responsibility for ensuring that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. Consultant for ExxonMobil. Project Manager Signature of Applicant or *Agent Title of Applicant or *Agent Jeremy Blumberg * If signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the Applicant, the property owner hereby consents to allow the Applicant to construct well(s) as outlined in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to ensure that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources’ Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 GW-22M/R (Rev. 5-26-2022) GW-22MR (6/11) GW-22M (Rev. 5/11) Tiffany Bauman Portfolio Manager, Americas Environmental Programs MW-13 MW-12 MW-11 AS-3 SVE-3 NOTES: FOU R S E A S O N S B O U L E V A R D (US H I G H W A Y 6 4 ) CAN O P Y EXX O N S E R V I C E S T A T I O N #45 5 5 2 CON C R E T E CON C R E T E 12 K U N L E A D E D 10 K E X T R A 8K E X X O N R E M E D I A T I O N T R A I L E R MW-9 MW-10 MW-3R MW-5 MW-1 MW-6 DW-1* MW-4* MW-8*INJ-2 AS-6 (ERM) AS-5 (ERM) AS-7 (ERM) AS-4 AS-1 AS-2 AS-4 (ERM) AS-3 (ERM) AS-2 (ERM) AS-1 (ERM) AS-8 (ERM) AS-9 (ERM) AS-10 (ERM) MW-2RVW-4 (ERM) VW-3 (ERM) SVE-1 SVE-2 VW-2 (ERM) VW-7 (ERM)VW-5 (ERM) VW-6 (ERM) VW-1 (ERM) SIGN 1" PIPE VMP-3 VMP-2 SB-1 (MiHP) SB-6 (MiHP) SB-5 (MiHP) SB-4 (MiHP) SB-8 (MiHP) SB-2 SB-3 SB-10 SB-7 SB-9 MW-7* 1,00 0 G A L L O N USE D - O I L U S T LEGEND PROPERTY BOUNDARY MONITORING WELL SOIL VAPOR EXTRACTION WELL VAPOR MONITORING POINT AIR SPARGE WELL GROUNDWATER ELEVATION ABANDONED/DESTROYED MONITORING WELL CHEMICAL INJECTION WELL // UNDERGROUND STORAGE TANK OVERHEAD POWER LINE ABANDONED/DESTROYED CHEMICAL INJECTION WELL MiHP LOCATION SOIL BORING LOCATION PROPOSED MONITORING WELL N CA D F I L E : G: \ C A D D \ K L F P R O J E C T S \ N O R T H C A R O L I N A \ C A D \ 4 5 5 5 2 \ 4 5 5 5 2 S P - S t a n d a r d \ 2 0 2 3 \ 4 5 5 5 2 _ M A R 2 3 . d w g L A Y O U T : F2 PL O T T E D : 7/ 1 9 / 2 0 2 3 1 2 : 5 0 P M B Y : ch r i s h a i t DRAWN BY DATE: PROJECT NO. CHECKED BY REVISED: FIGURESITE PLAN EXXONMOBIL SERVICE STATION #4-5552 1920 4 SEASONS BOULEVARD HENDERSONVILLE, NORTH CAROLINA 20212946 CTH MR 07/18/2023 1 0 SCALE IN FEET 30 60 SCALE: 1" = 30' NOTES: 1.BASE MAP PREPARED FROM A DRAWING "MONITORING WELL LOCATION SURVEY" PROVIDED BY TWT (TAYLOR WISEMAN & TAYLOR), CHARLOTTE, NC; DATED AUGUST 21, 2019. 24-INCH 24-INCH BOLT-DOWN MANHOLE CENTERED IN 2-FEETx2-FEET CONCRETE PAD MONITORING WELL (2-FEET X 2-FEET MINIMUM) CONCRETE PAD 2-INCH DIAMETER SCHEDULE 40 PVC WELL CASING 6-INCH DIAMETER BOREHOLE GROUND SURFACE LOCKING CAP 2-INCH 0.010" SLOTTED SCHEDULE 40 PVC WITH SOCKET CONNNECTION 12-INCH DIAMETER MANHOLE WITH BOLT DOWN LID GROUT SLOPED AWAY FROM MANHOLE FOR DRAINAGE CEMENT PAD BENTONITE SEAL #2 SAND PACK 6" 1'-0" 5'-0" 25'-6" BGS 20'-0" The information included on this graphic representation has been compiled from a variety of sources and is subject to change without notice. Kleinfelder makes no representations or warranties, express or implied, as to accuracy, completeness, timeliness, or rights to the use of such information. This document is not intended for use as a land survey product nor is it designed or intended as a construction design document. The use or misuse of the information contained on this graphic representation is at the sole risk of the party using or misusing the information. CA D F I L E : G: \ C A D D \ K L F P R O J E C T S \ N O R T H C A R O L I N A \ C A D \ 4 5 5 5 2 \ 4 5 5 5 2 S P - S t a n d a r d \ 2 0 2 3 \ 4 5 5 5 2 _ W e l l C o n . d w g PL O T T E D : 8/ 2 1 / 2 0 2 3 2 : 3 0 P M B Y : ch r i s h a i t FIGURE DRAWN BY: PROJECT NO. CHECKED BY: REVISED: DATE: WELL CONSTRUCTION DETAIL (MW-12 AND MW-13) EXXONMOBIL SERVICE STATION #4-5552 1920 4 SEASONS BOULEVARD HENDERSONVILLE, NORTH CAROLINA 20212946 CTH MR 08/21/2023 1 KLEINFELDER - #### | #### | PH: #### | FAX: #### | www.kleinfelder.com