Loading...
HomeMy WebLinkAboutNCG551026_2024 Effluent Sampling Report_20240117ENVIRONMENTAL - WATER SUPPLY - WASTEWATER CONNER CONSULTING, LLC 12284 WINDY RIDGE ROAD, CHAPEL HILL, NORTH CAROLINA 27517 PHONE: (919) 260.7301 .............................................................................. .............................................................................. January 17, 2024 Mr. Stephen Jonsdotter 726 Donlee Drive Durham, North Carolina 27712 Re: Effluent Sampling NCG551026 Residence 726 Donlee Drive Durham, Durham County Dear Mr. Jonsdotter: On January 8, 2024, Conner Consulting collected effluent samples as required on your septic system permit at 726 Donlee Drive, Durham. The results are as follows: Flow Yes, <100 gpd estimated Total Residual Chlorine: 2.2 ppm @ 11:40 BOD 41 mg/L TSS 4.0 mg/L Fecal Coliform <1.0 cfu See attached lab results The wastewater treatment system appears to be working properly. My field laboratory certification is #5149. Please call with questions and comments. Sincerely yours, Chad Leinbach Conner Consulting, LLC Field Laboratory Certification #5149 • % eurofins Environment Testing I ANALYTICAL REPORT C PREPARED FOR Attn: Chad Leinbach Conner Consulting 1284 WINDY RIDGE RD C CHAPEL HILL, North Carolina 27517 Generated 1 /16/2024 10:37:01 AM JOB DESCRIPTION Eff- 726 Donlee Drive JOB NUMBER 752-15359-1 This report may not be reproduced except in full, and with written approval from the laboratory. The results relate only to the samples tested. For questions please contact the Project Manager at the e-mail address or telephone number listed on this page. L The test results in this report relate only to the samples as received by the laboratory and will meet all requirements of the methodology, with any exceptions noted. This report shall not be reproduced except in full, without the express written approval of the laboratory. All questions should be directed to the Eurofins Environment Testing Southeast, LLC Project Manager. 6#o* Generated 1 /16/2024 10:37:01 AM r Authorized for release by Heather Trotter, Project Manager Heather.Trotter@et.eurofinsus.com (912)354-7858 Eurofins Savannah is a laboratory within Eurofins Environment Testing Southeast, LLC, a company within Eurofins Environment Testing Group of Companies Page 2 of 15 1 /16/2024 Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive Table of Contents Laboratory Job ID: 752-15359-1 C Cover Page .............................................. 1 Table of Contents ......................................... 3 Definitions/Glossary....................................... 4 L Case Narrative ........................................... 5 Detection Summary ........................................ 6 Client Sample Results ...................................... 7 QC Sample Results ........................................ 8 QC Association Summary ................................... 9 E: Lab Chronicle ............................................ 10 F Certification Summary ...................................... 11 Method Summary ......................................... 12 Sample Summary ......................................... 13 Chain of Custody .......................................... 14 Receipt Checklists ......................................... 15 F Eurofins Raleigh Page 3 of 15 1 /16/2024 Definitions/Glossary Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive Qualifiers General Chemistry Qualifier Qualifier Description b Result Detected in the Unseeded Control blank (USB). Glossary Abbreviation These commonly used abbreviations may or may not be present in this report. a Listed under the "Y column to designate that the result is reported on a dry weight basis %R Percent Recovery CFL Contains Free Liquid CFU Colony Forming Unit CNF Contains No Free Liquid DER Duplicate Error Ratio (normalized absolute difference) Dil Fac Dilution Factor DL Detection Limit (DoD/DOE) DL, RA, RE, IN Indicates a Dilution, Re -analysis, Re -extraction, or additional Initial metals/anion analysis of the sample DLC Decision Level Concentration (Radiochemistry) EDL Estimated Detection Limit (Dioxin) LOD Limit of Detection (DoD/DOE) LOQ Limit of Quantitation (DoD/DOE) MCL EPA recommended "Maximum Contaminant Level' MDA Minimum Detectable Activity (Radiochemistry) MDC Minimum Detectable Concentration (Radiochemistry) MDL Method Detection Limit ML Minimum Level (Dioxin) MPN Most Probable Number MQL Method Quantitation Limit NC Not Calculated ND Not Detected at the reporting limit (or MDL or EDL if shown) NEG Negative / Absent POS Positive / Present IDOL Practical Quantitation Limit PRES Presumptive QC Quality Control RER Relative Error Ratio (Radiochemistry) RL Reporting Limit or Requested Limit (Radiochemistry) RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin) TEQ Toxicity Equivalent Quotient (Dioxin) TNTC Too Numerous To Count Job ID: 752-15359-1 Eurofins Raleigh Page 4 of 15 1 /16/2024 Case Narrative Client: Conner Consulting Project: Eff- 726 Donlee Drive Job ID: 752-15359-1 Job ID: 752-15359-1 Eurofins Raleigh Job Narrative 752-15359-1 Receipt The sample was received on 1/8/2024 1:53 PM. Unless otherwise noted below, the sample arrived in good condition, and where required, properly preserved and on ice. The temperature of the cooler at receipt was 2.90 C. General Chemistry Method SM 521013: The method blank result associated with batch 752-5859 was higher than the method -required limit of 0.2 mg/L. Method SM 5210B: During the 5-day BOD/CBOD incubation period, the temperature inside the incubator exceeded the method - required 20±1 °C control limit. On Tuesday, January 9, 2024, a weathered power outage occurred causing the incubator to read 25°C. The incubator was reset and the temperature returned to the method required limit. The following samples is impacted: Eff.- 726 Donlee Drive (752-15359-1), (LCS 752-5859/3), (SCB 752-5859/2), (USB 752-5859/1), (752-15355-A-1) and (752-15355-A-1 DU). No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. Biology No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. 0 Page 5 of 15 Eurofins Raleigh 1 /16/2024 Detection Summary Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive F Job ID: 752-15359-1 Client Sample ID: Eff.- 726 Donlee Drive Lab Sample ID: 752-15359-1 Analyte Result Qualifier RL MDL Unit Dil Fac D Method Prep Type Total Suspended Solids 4.0 3.6 3.6 mg/L 1 SM 2540D Total/NA Biochemical Oxygen Demand 41 b 2.0 2.0 mg/L 1 SM 5210B Total/NA This Detection Summary does not include radiochemical test results. Eurofins Raleigh Page 6 of 15 1 /16/2024 Client Sample Results Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive F Job ID: 752-15359-1 Client Sample ID: Eff.- 726 Donlee Drive Lab Sample ID: 752-15359-1 Date Collected: 01/08/24 11:35 Matrix: Water Date Received: 01/08/24 13:53 General Chemistry Analyte Result Qualifier Total Suspended Solids (SM 4.0 2540D) Biochemical Oxygen Demand (SM 41 b 5210B) Method: IDEXX Coliform - Coliforms, Fecal Analyte Result Qualifier Coliform, Fecal <1.0 RL MDL Unit D Prepared Analyzed Dil Fac 3.6 3.6 mg/L 01/11/24 09:18 1 2.0 2.0 mg/L 01/09/2416:43 1 RL MDL Unit D Prepared Analyzed Dil Fac 1.0 1.0 MPN/100ml- 01/08/2414:59 1 Eurofins Raleigh Page 7 of 15 1 /16/2024 QC Sample Results Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive Method: SM 2540D - Solids, Total Suspended (TSS) Lab Sample ID: MB 752-5820/1 Matrix: Water Analysis Batch: 5820 MB MB Analyte Result Qualifier RL Total Suspended Solids <2.5 2.5 Lab Sample ID: LCS 752-5820/2 Matrix: Water Analysis Batch: 5820 Spike Analyte Added Total Suspended Solids 100 Method: SM 5210B - BOD, 5-Day Lab Sample ID: SCB 752-5859/2 Matrix: Water Analysis Batch: 5859 SCB SCB Analyte Result Qualifier Biochemical Oxygen Demand 0.989 Lab Sample ID: USB 752-5859/1 Matrix: Water Analysis Batch: 5859 USB USB Analyte Result Qualifier Biochemical Oxygen Demand 0.780 Lab Sample ID: LCS 752-5859/3 Matrix: Water Analysis Batch: 5859 Analyte Biochemical Oxygen Demand F Job ID: 752-15359-1 Client Sample ID: Method Blank Prep Type: Total/NA L MDL Unit D Prepared Analyzed Dil Fac 2.5 mg/L 01/11/24 09:18 1 Client Sample ID: Lab Control Sample Prep Type: Total/NA LCS LCS %Rec Result Qualifier Unit D %Rec Limits 103 mg/L 103 80-120 Client Sample ID: Method Blank Prep Type: Total/NA RL MDL Unit D Prepared Analyzed Dil Fac 0.0000020 0.0000020 mg/L 01 /09/24 16:11 1 Client Sample ID: Method Blank Prep Type: Total/NA RL MDL Unit D Prepared Analyzed Dil Fac 0.0000020 0.0000020 mg/L 01/09/2416:06 1 Client Sample ID: Lab Control Sample Prep Type: Total/NA Spike LCS LCS Added Result Qualifier Unit 198 211 mg/L %Rec D %Rec Limits 107 85-115 Page 8 of 15 Eurofins Raleigh 1 /16/2024 QC Association Summary Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive General Chemistry Analysis Batch: 5820 Lab Sample ID Client Sample ID 752-15359-1 Eff.- 726 Donlee Drive MB 752-5820/1 Method Blank LCS 752-5820/2 Lab Control Sample Analysis Batch: 5859 Lab Sample ID Client Sample ID 752-15359-1 Eff.- 726 Donlee Drive SCB 752-5859/2 Method Blank USB 752-5859/1 Method Blank LCS 752-5859/3 Lab Control Sample F Job ID: 752-15359-1 Prep Type Matrix Method Prep Batch Total/NA Water SM 2540D Total/NA Water SM 2540D Total/NA Water SM 2540D Prep Type Matrix Method Prep Batch Total/NA Water SM 5210B Total/NA Water SM 5210B Total/NA Water SM 5210B Total/NA Water SM 5210B Biology Analysis Batch: 5804 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 752-15359-1 Eff.- 726 Donlee Drive Total/NA Water Coliform Eurofins Raleigh Page 9 of 15 1 /16/2024 Lab Chronicle Client: Conner Consulting Job ID: 752-15359-1 Project/Site: Eff- 726 Donlee Drive Client Sample ID: Eff.- 726 Donlee Drive Lab Sample ID: 752-15359-1 Date Collected: 01/08/24 11:35 Matrix: Water Date Received: 01/08/24 13:53 Batch Batch Dilution Batch Prepared Prep Type Type Method Run Factor Number Analyst Lab or Analyzed Total/NA Analysis SM 2540D 1 5820 CB EET ESC 01/11/24 09:18 Total/NA Analysis SM 5210B 1 5859 JC EET ESC 01/09/24 16:43 Total/NA Analysis Coliform 1 5804 CB EET ESC 01/08/24 14:59 - 01/09/24 11:15' ' This procedure uses a method stipulated length of time for the process. Both start and end times are displayed. Laboratory References: EET ESC = Eurofins Raleigh, 102-A Woodwinds Industrial Court, Cary, NC 27511, TEL (919)677-1669 E Eurofins Raleigh Page 10 of 15 1 /16/2024 Accreditation/Certification Summary Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive Laboratory: Eurofins Raleigh The accreditations/certifications listed below are applicable to this report. Authority Program Identification Number Expiration Date North Carolina (WW/SW) State 591 12-31-24 Job ID: 752-15359-1 10 Eurofins Raleigh Page 11 of 15 1 /16/2024 Method Summary Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive Job ID: 752-15359-1 Method Method Description Protocol Laboratory SM 2540D Solids, Total Suspended (TSS) SM EET ESC SM 5210B BOD, 5-Day SM EET ESC Coliform Coliforms, Fecal IDEXX EET ESC Protocol References: IDEXX = IDEXX Laboratories SM = "Standard Methods For The Examination Of Water And Wastewater" Laboratory References: EET ESC = Eurofins Raleigh, 102-A Woodwinds Industrial Court, Cary, NC 27511, TEL (919)677-1669 Eurofins Raleigh Page 12 of 15 1 /16/2024 Sample Summary Client: Conner Consulting Project/Site: Eff- 726 Donlee Drive Lab Sample ID Client Sample ID Matrix Collected Received 752-15359-1 Eff.- 726 Donlee Drive Water 01/08/24 11:35 01/08/24 13:53 Job ID: 752-15359-1 Page 13 of 15 Eurofins Raleigh 1 /16/204 r U in pm a OM" ZUa Sm N %m.Z- N 2 m O ^\ t c m c c o Itl iNv0. uu� to� � Sz¢zz2h(7 U ¢i aFF- o S` N ZOa OWWM'Di3:Y N U U A x��� xi ta¢ z U �¢ � E ✓fie00 N o b1 SZIZZ g¢¢ $OLUw ® v D U- U as a ry ¢a3Uawu c9x x `b' b °i i a y 4 yd E c ` v a09 eleD H9LZSWS'°"Tl u lb G v w' U p o leael'woillo0 m InIG0 mal H! N Q � p l� fi n �i11M'�3i�NN.�.f.9E499 � 2 p m C Q� m m CJ rn m y CL X 8 d 8 41 c� O U ': �r D E 5, m 'v _ C a'.. ry5 m a Q 0 0P. 7 O o �ONj N W Q. A F- U a. � d N CO .H 4 a o 'm a w U CL H U Z N -2 m 0 �+ U Eta ch I N cZ w � to o >- ❑ � ti m � c 4i c o � � T m �, m ...3 d n R� v U CivU U ¢� t3U niz aa� w o u mZ V1' 4 Q W cc Q� Page 14 of 15 1 /16/2024 Login Sample Receipt Checklist Client: Conner Consulting Job Number: 752-15359-1 Login Number: 15359 List Number: 1 Creator: Hyatt, Samantha Question List Source: Eurofins Raleigh Answer Comment Radioactivity wasn't checked or is </= background as measured by a survey True meter. The cooler's custody seal, if present, is intact. True Sample custody seals, if present, are intact. True The cooler or samples do not appear to have been compromised or True tampered with. Samples were received on ice. True Cooler Temperature is acceptable. True Cooler Temperature is recorded. True COC is present. True COC is filled out in ink and legible. True COC is filled out with all pertinent information. True Is the Field Sampler's name present on COC? True There are no discrepancies between the containers received and the COC. True Samples are received within Holding Time (excluding tests with immediate True m HTs) Sample containers have legible labels. True Containers are not broken or leaking. True Sample collection date/times are provided. True Appropriate sample containers are used. True Sample bottles are completely filled. True Sample Preservation Verified. True There is sufficient vol. for all requested analyses, incl. any requested True MS/MSDs Containers requiring zero headspace have no headspace or bubble is True <6mm (1/4"). Multiphasic samples are not present. True Samples do not require splitting or compositing. True Residual Chlorine Checked. True Eurofins Raleigh Page 15 of 15 1 /16/2024