Loading...
HomeMy WebLinkAboutNCG030721_Inspection Report_20240110 Compliance Inspection Report Permit:NCG030721 Effective: 09/13/21 Expiration: 06/30/26 Owner: Southwire Company LLC-Youngsville SOC: Effective: Expiration: Facility: DCN Cables,A Southwire Company County: Franklin 130 Mosswood Blvd Region: Raleigh Youngsville NC 27596 Contact Person:Kenneth Playford Title: Phone:470-230-9903 Directions to Facility: System Classifications: SWNC, Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: Inspection Date: 01/10/2024 Entry Time 01:10PM Exit Time: 02:20PM Primary Inspector:Thaddeus W Valentine Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NCG030721 Owner-Facility:Southwire Company LLC-Youngsville Inspection Date: 01/10/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Inspection Summary: The facility was able to provide additional information on the SWPPP after the inspection. The SWPPP was generic and was not site specific and many of the permit requirements were no available including a list of significant spills, feasability study and site specific BMP summery. They did perform regular inspections but they didn't focus on all the areas of concern or specifically what to look for and the ionspections were only done during the second shift. Although there is training materials in the SWPPP no one knew they had the training. The facility has added a shelter to store wood materials under outside and have included connex boxes to store materials outside. The facility has also installed hand operated roll-off dumpster covers to cover roll-offs during rain. The facility has made significant effgerts to keep everything under cover to prevent pollutants in the stormwater. We suggest additional training that is site specific and continued inspections to maintain no exposure. I recommend the no exposure be approved due to efforts by the facility to store and stage everything under cover. Page 2 of 3 Permit: NCG030721 Owner-Facility:Southwire Company LLC-Youngsville Inspection Date: 01/10/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ❑ ❑ ❑ #Does the Plan include a General Location (USGS) map? ❑ ❑ ❑ #Does the Plan include a"Narrative Description of Practices"? ❑ ❑ ❑ #Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ #Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ #Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ #Does the facility provide all necessary secondary containment? ❑ ❑ ❑ #Does the Plan include a BMP summary? ❑ ❑ ❑ #Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ #Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ❑ ❑ #Does the facility provide and document Employee Training? ❑ 0 ❑ ❑ #Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ 0 ❑ ❑ #Does the Plan include a Stormwater Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: The facility was able to provide the information after the fact, but there ware parts missing and not demonstrated as required by the permit. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring? 0 ❑ ❑ ❑ Comment: Provided after the inspection Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ #Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: Provided after the inspection Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ❑ ❑ ❑ #Were all outfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ #Has the facility evaluated all illicit(non stormwater)discharges? ❑ 0 ❑ ❑ Comment: The one outfall was observed Page 3 of 3