Loading...
HomeMy WebLinkAboutSW4231202_Supplement-EZ Form_20231229 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name The Townes at Bermuda Run-Phase 1 2 Project Area(ac) 21.99 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 1.53 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 30' 8 Will the vegetated setback remain vegetated'? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 2 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Clark A.Fleming,P.E. 28 Organization: Evans Engineering,Inc. 29 Street address: 4609 Dundas Drive 30 City,State,Zip: Greensboro,NC 27407 31 Phone number(s): 336-854-8877 32 Email: caf@evans-eng.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here, Designer `_s���t1111111111//0// •'Q. SE/IL _ Signature of Designer • • 035Q1.h • • •� ��/0l$fB01111\ Date DRAINAGE AREAS 1 Is this a high density project? Yes , 2 If so,number of drainage areas/SCMs 2 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS WADED DRAINAGE AREA INFORMATION 1 2 LD 9 I 4 T •e of SCM 1111111111111.1 Wet Pond#1 i Wet Pond#2 None 5 Total draina•e area s• ft 545 634 ( 219,121 " 275,685 50,828 6 Onsite drainage area s• ft 542,217 218,289 273,100 50,828 7 Offsite draina•e area s• ft 3 421 832 2,589 '` N/A 8 Total BUA in •ro'ect s•ft 270911 sf { 122617 sf 139136 sf ( 9158 sf New BUA on subdivided lots(subject to permitting) 9 s•ft 159590 sf 71198 sf 88392 sf N/A New BUA not on subdivided lots(subject to 110 •ermittin• s 111321 sf _ 51419 sf 50744 sf 9158 sf 11 Offsite BUA s•ft N/A } N/A I N/A N/A ®Breakdown of new BUA not on subdivided lots: 1111 -Parkin• s•ft 6605 sf 3330 sf !® N/A - -Sidewalk s•ft 15572 sf 7238 sf 6462 sf 1872 sf 1111 -Roof s•ft 159590 sf 71198 sf 88392 sf N/A -Roadwa s• ft 89144 sf j 40851 sf 41007 sf 7286 sf IIIIINESEIREIIIIIIIIIIIIIIIIIIIMIIIIIIIN/A I N/A N/A N/A Other,please specify in the comment box below s• ft N/A N/A [ N/A N/A IIINew infiltrating permeable pavement on subdivided lots s•ft N/A N/A N/A N/A New infiltrating permeable pavement not onIII C i subdivided lots s•ft N/A N/A N/A N/A ®Existing BUA that will remain(not subject to •ermittin• s•ft N/A N/A N/A N/A 16 Existin• BUA that is alread •ermitted s• ft N/A N/A p N/A N/A ®Existin• BUA that will be removed s• ft N/A N/A N/A N/A 18 Percent BUA 50% 56% 50% ' 18% 19 Desi•n storm inches N/A 1.0 in 1.0 in N/A 20 Desi.n volume of SCM cu ft N/A 10136 cf 4mv 11696 cf N/A ®Calculation method for design volume N/A Simple Method Simple Method N/A ADDITIONAL INFORMATION IIIPlease use this space to provide any additional information about the drainage area(s): WET POND '1 Drainage area number 1 2 2 Minimum required treatment volume Scu ft) i`L 11..h -IL.%, t.:i 'I.ii 3 Is the SCM sized to treat the SW from all surfaces at build-out?4 Is the SCM located away from contaminated soils? 1111.011111111 Yes ©What are the side slopes of the SCM(H: ? 3:1 3:1 Does the SCM have retaining walls,gabion walls or other engineered1111 No No side slosea? IIEAre the inlets,outlets,and receiving stream protected from erosion Yes (10-year storm? Ell Isthere an overflow or bypass for inflow volume in excess of the No No deli.n volume? 9 What is the method for dewatering the SCM for maintenance? Pum. .referred Pum. .referred 10 If applicable,will the SCM be cleaned out after construction? MEI Does the maintenance access comply with General MDC(8)? M.11. ®Does the drainage easement comply with General MDC(9)? 11.111011111111 ®If the SCM is on a single family lot,does(will?)the plat comply with N/A N/A General MDC(10)? •Is there an O&M Agreement that complies with General MDC(11)? Yes ®Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Nip Was the SCM desi.ned b an NC licensed .rofessional? 18 Sizing method used SA/DA� SA/DA 19 Has a stage/storage table been provided in the calculations? Yes Yes 20 Elevation of the excavated main pool depth(bottom of sediment 739.00 722.00 removal fmsl) ®Elevation of the main pool bottom(top of sediment removal)(fmsl) 739.50 I 722.50 ®Elevation of the bottom of the vegetated shelf(fmsl) 744.50 726.50 ®Elevation of the permanent pool(fmsl) 745.00 727.00 24 Elevation of the top of the vegetated shelf(fmsl) 745.50 727.50 ®Elevation of the temporary pool(fmsl) 747.50 730.00 26 Surface area of the main permanent pool(square feet) 6,197 SF 5,781 SF NM Volume of the main permanent pool(cubic feet) 21051 cf 16803 cf 28 Average depth of the main pool(feet) 3.80 ft 3.27 ft 29 Average depth equation used E. .f. Equation 3 30 If using equation 3,main pool perimeter(feet 242.0 ft 240.0 ft ® If using equation 3,width of submerged veg.shelf(feet) 3.0 ft 3.0 ft ®Volume of the forebay(cubic feet) 3693 cf 2640 cf ®Is this 15-20%of the volume in the main pool? Yes 34 Clean-out depth for forebay(inches) 36 in ®Design volume of SCM(cu ft) 10136 cf 11696 cf 36 Is the outlet an orifice or a weir? Orifice Orifice Egg If orifice,orifice diameter(inches) 2 in '=C' 38 If weir,weir height(inches) N/A N/A 39 If weir,weir length(inches) N/A N/A Drawdown time for the temporary pool(days) 3.43 �'� Are the inlet(s)and outlet located in a manner that avoids short- i circuiting? Yes Yes 42 Are berms or baffles provided to improve the flow.ath? Yes Yes 43 Depth of forebay at entrance(inches) 48 in 48 in 44 Depth of forebay at exit inches) 36 in 36 in 45 Does water flow out of the forebay in a non-erosive manner? Yes Yes 46 Width of the vegetated shelf(feet 6 ft 6 ft 47 Slope of vegetated shelf(H:V) 6:1 6:1 Does the orifice drawdown from below the top surface of the No No .ermanent pool? Does the pond minimize impacts to the receiving channel from the 1- Yes Yes E yr,24-hr storm? Are fountains proposed?(If Y,please provide documentation that 50 MDC(9)is met.) No No ®Is a trash rack or other device provided to protect the outlet system? Yes Yes MEAre the dam and embankment planted in non-clumping turf grass? Yes Yes Species of turf that will be used on the dam and embankment Fescue 11111=maM Hasa.Iantin. .Ian been .rovided for the vegetated shelf? Yes ADDITIONAL INFORMATION ®Please use( this space to provide any additional information about the pond(s): and s) Wet Pond 1 1:59 PM 12/5/2023