HomeMy WebLinkAboutNC0089893_Compliance Evaluation Inspection_20231211ROY COOPER Governor ELIZABETH S. BISER Secretury RICHARD E. ROGERS, JR. Director Mr. John Shutak Union County Public Works 500 N Main St., Suite 600 Monroe, NC 28112 SUBJECT: Compliance Evaluation Inspection Permit No. NCO089893 Crooked Creek WWTP #2 Union County Mr. Shutak: NORTH CAROLINA Environmental Quality December 12, 2023 The North Carolina Division of Water Resources conducted a Compliance Evaluation Inspection (CEI) of the Yadkin River WTP on December 5, 2023. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0089893. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. We would like to thank the operating staff for their assistance during this inspection. If you should have any questions, please do not hesitate to contact Roberto Scheller with the Water Quality Regional Operations Section in the Mooresville Regional Office at 704-663-1699. Sincerely, DocuSigned by: L 27DF9ACF858041F... for Andrew H. Pitner, P.G., Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Mooresville Regional Office - Enforcement File o.wm.�raua�n.miowrm` /"� North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO089893 111 121 23/12/05 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701� I 711 L LJ L -1 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 11:03AM 23/12/05 23/05/01 Yadkin River Water Treatment Plant 3522 New Salem Rd Exit Time/Date Permit Expiration Date Unionville NC 28110 12:07PM 23/12/05 25/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Jonathan T Smith/ORC/704-320-6758/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Brian Matthews,500 N Main St Ste 920 Monroe NC 28112//704-292-2597/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Records/Reports Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Sig natur )Dqt g%R"r(s) Agency/Office/Phone and Fax Numbers Date Lrtj�6 ��Roberto Scheller DWR/MRO WQ/707-235-2204/ 12/11/2023 2A007838943E... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Brandy Costner DWR/MRO WQ/704-235-2185/ DocuSigned by: 12/12/2023 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. �-27DF9ACFbs8043F... Page# NPDES yr/mo/day Inspection Type NCO089893 I11 12I 23/12/05 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The Yadkin River Water Treatment Plant has Grade I Physical -Chemical treatment under NPDES Permit # NC0089893. The subject permit became effective July 1, 2020, and expires on June 30, 2025. Facility has a design potable flowrate of 13 MGD and a maximum monthly average wastewater discharge of 0.49 MGD. Discharge is into an unnamed tributary of Richardson Creek, Class C waters, in the Yadkin -Pee Dee River Basin. During the on -site inspection and records review it was noted that flow rates are above permitted limits. Facility is reported as having issues with start-up and as of the date of inspection, has not started producing potable water for distribution. Flow is to be reported in Million Gallons per Day (MGD). Effluent discharge was clear with no visible suspended soilds at point of discharge from Outfall #001. Discharge pipe stops short of creek and flows down gradient, overland, to creek creating erosion and turbidity issues. Effluent should be in a pipe or lined constructed channel to discharge into Ut of Richardson Creek. Please note that construction of discharge point on creek may require a 404 and/or 401 Permit. Page# Permit: NC0089893 Inspection Date: 12/05/2023 Owner -Facility: Yadkin River Water Treatment Plant Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 3