Mr. Eplin,
Attached are the original and revised design calculations for the storage volume of basin SB-5,the basin
associated with Outfall SDO-003 (see Attachment 5 and Figure 2 of the previously submitted action plan).The
minimum storage volume required for the drainage area to SB-5 is 15,354 cubic feet.The original volume provided
in SB-5 (at the elevation of the primary outlet)was 68,148 cubic feet.The extra foot of rock below the skimmer in
SB-5 will effectively reduce the volume of the basin by 8,954.2 cubic feet, resulting in an effective storage volume
of 59,193.8 cubic feet.The effective storage volume of SB-5 will still exceed the required minimum storage volume
for the drainage area following the proposed modification.
Thankyou,
Caroline L. Funderburk, P.E.
1029 W. South St.
Raleigh, NC 27603
Mobile: 919.738.9583
www.garrett-moore.com
From: Eplin,Jerry W<jerry.eplin@deq.nc.gov>
Sent: Sunday, November 26, 2023 2:59 PM
To: Caroline Funderburk<clafave@garrett-moore.com>
Cc: Peterson, Kathryn S<kathryn.peterson@deq.nc.gov>
Subject:Action Plan submitted for TSS at outfall SDO-003
NC DEQ has reviewed the "Corrective Action Plan for Total Suspended Solids at Outfall SDO-003"for the Cleveland
County Landfill Facility. Upon review DEQ needs additional information.
The skimmer design calculations were provided; however, the basin design was not provided. DEQ is generally
supportive of the proposed plan for adding an extra foot of rock below the skimmer to keep it out of the collected
sediment. However, this means that the basin would never fully drain, thus the effective volume of the basin would be
reduced. Can you provide information on basin design showing that it will achieve the required design volume with the
reduction caused by this modification?
i
Jerry W. Eplin, PE
Assistant Regional Engineer
North Carolina Department of Environmental Quality
Division of Energy, Mineral, and Land Resources
Office: (704) 235-2147
Email: jerry.eplin@deq.nc.gov
Physical and Mailing Address:
610 E. Center Ave. Suite 301
Mooresville, NC 28115
�e-e��D,- E
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties
Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized
state official.
2
SB-5 Storage Calculations
Depth (FT) 0 0 Storage (FT^3) SB-5 Storage Curve
3 33642 250000
5 68148
8 136152.9 200000
101 193328.11 <
150000
E
0 100000
r°po 50000
N l
0 ••
0 2 4 6 8 10 12
-50000
Depth(FT)
Drainage Area = 8.53 ACRES
Vreq = (1800 CF/acre)(Drainage Area)
= 15,354.00 CF
Vprovided = 68,148.00 CF
Provided storage is greater than required.
March 2020
SB-5 Storage Calculations
Depth (FT) Storage (FT^3) SB-5 Storage Curve
0 0.0
8,954.2 250,000.0
3 33,642.0
5 68,148.0 200,000.0
81 136,152.9 m
10 193,328.1 150,000.0
;_
0 100,000.0
50,000.0
o �•
2 4 6 8 10 12
-50,000.0
Depth (FT)
Drainage Area = 8.53 ACRES
Vreq = (1800 CF/acre)(Drainage Area)
= 15,354.0 CF
Original Vprovided = 68,148.0 CF
Less Vdepth of 1 foot = 8,954.2 (reduction in pond volume due to elevation of skimmer pad by 1 foot)
Veffective = 59,193.8
Effective provided storage is greater than required.
Revised December 2023