Loading...
HomeMy WebLinkAboutNCG060175_Frito -Lay Inc. Inspection Report_20231211 ChmrfoN-M4cA4nburg ji / STORM Facility Inspection Wi E 5tormW ate r.Cho rMeck.org SuviceS Facility Name: Frito Lay Incorporated Inspection#: 80771 Contact: Sam Denison, EH&S Manager Permit#: NCG060175 Inspector: Michael Schley Receiving Stream: STEELE Inspection Date: 12/04/2023 Entry Time: 1:00 pm Exit Time: 2:30 pm SIC#: 2096 SUMMA Facility Description: Frito Lay Inc. is located at 2911 Nevada Boulevard in Charlotte, NC on 29.33 acres.The facility manufactures and packages potato and corn chips. File Review/History:The facility was previously inspected by Charlotte-Mecklenburg Storm Water Services (CMSWS) on 2/21/2019, and the report was issued as satisfactory. Inspection Summary: During the inspection, Frito Lay Inc.was observed to be in compliance with the City of Charlotte Storm Water Pollution Control Ordinance. Please refer to the report for comments and recommendations. Site Inspection Deficiency Comments Stormwater system (catch basins, Satisfactory Stormwater flows through the site via sheet flow which enters inlets, outfalls, etc.) a series of catch basins before discharging from three outfalls . No stormwater pollution issues were observed. Erosion issues Satisfactory No stormwater erosion issues were observed onsite during the inspection. Structural stormwater control N/A measures(SCMs) Illicit discharges/connections Satisfactory No illicit discharges or connections were observed onsite during the inspection. Aboveground storage tank(s)(ASTs) Satisfactory ASTs were observed throughout the facility.A complete list of and any associated venting and/or AST contents,sizes, secondary containment and locations dispenser(s)—list tank size(s)and was observed in the SWPPP and SPCC plans for the facility. contents No stormwater pollution issues were observed. Underground storage tank(s)(USTs) Satisfactory One 20,000-gallon diesel UST is located on the property near and any associated fill port area(s) the maintenance shop. No stormwater pollution issues were and dispenser(s)—list tank size(s) observed with the associated fill ports and dispensers. and contents Outdoor material storage area(s) Recommendation Assorted equipment and supplies for food production were observed to be stored outdoors under cover. Tires were observed to be stored outdoors at the maintenance shop. Water softening resin pellets used for equipment cleaning were observed on the ground near the outdoor storage and waste area. CMSWS recommends all spills are cleaned promptly and properly to help protect water quality. Follow-up photos to document the resin pellet cleanup were submitted to CMSWS on 12/7/2023. Outdoor processing area(s) N/A Loading/unloading area(s) Satisfactory No stormwater pollution issues were observed. To report pollution or drainage problems call: 311 :T CIIARLOTTE_ http://stormwater.charmeck.org 12/8/2023 12:17:09PM Page 1 of 3 Site Inspection Deficiency Comments Vehicle/equipment area(s)-fueling, Satisfactory Vehicle maintenance is conducted inside the maintenance maintenance,washing, storage, etc. shop.Vehicle fueling is conducted at the covered fueling area .Vehicle washing is conducted in an indoor wash bay at the maintenance shop. Vehicles and equipment were observed to be stored uncovered outdoors. No stormwater pollution issues were observed. Oil/water separator and/or Satisfactory Per facility staff,floor drains at the manufacturing building, pretreatment maintenance shop,fueling area, and wash bay drain to an oil water separator before discharging to the facility's onsite wastewater treatment plant.The facility has a pretreatment permit with Charlotte Water to discharge into the sanitary sewer system. No stormwater pollution issues were observed Waste storage/disposal area(s)- Recommendation One municipal waste container was observed with rain flaps open tops,waste containers, scrap and drain plugs in place.Three open top waste containers metal bins, etc. were observed to be kept uncovered outdoors. CMSWS recommends all outdoor waste containers are kept covered to help protect water quality. Reference the'Outdoor Material Storage'section of the report for additional recommendations. Food service area(s) N/A Indoor material storage area(s) Satisfactory Assorted materials, equipment and supplies for potato and corn chip manufacturing and packaging were observed inside the production facility.Assorted equipment and supplies for vehicle maintenance were observed inside the maintenance shop. No stormwater pollution issues were observed. Indoor processing area(s) Satisfactory Corn and potato chip production and packaging was observed to be conducted inside the production facility. Vehicle maintenance was observed to be conducted inside the maintenance shop. No stormwater pollution issues were observed. Floor drains Satisfactory Per facility staff,floor drains in the manufacturing building, maintenance shop,fueling area and wash bay drain to an oil water separator before discharging to the facility's onsite wastewater treatment plant. No stormwater pollution issues were observed. Spill response equipment Satisfactory Spill response equipment was observed throughout the production and maintenance facilities, and at the covered fueling area. No stormwater pollution issues were observed. SWPPP Section Observed Comments Does the facility have a Stormwater Satisfactory Pollution Prevention Plan (SWPPP)? Reviewed and updated annually Satisfactory The SWPPP was reviewed and updated in April of 2023. Responsible party Satisfactory General location (USGS)map Satisfactory Detailed site map Satisfactory Narrative description of industrial Satisfactory processes Feasibility study Satisfactory Evaluation of stormwater outfalls(non Satisfactory A non-stormwater discharge evaluation was conducted and -stormwater discharge evaluation) recorded on 3/14/2023. Stormwater best management Satisfactory practice(BMP)summary To report pollution or drainage problems call: 311 CttARIAI'TE_ http://stormwater.charmeck.org 12/8/2023 12:17:09PM Page 2 of 3 EM SWPPP Section Observed Comments Secondary containment plan (all Satisfactory necessary secondary containment provided and documented) Records on every release from a N/A Stormwater that accumulates in the uncovered ASTs is secondary containment system (for discharged to the onsite wastewater treatment plant. the last 5 years) Spill prevention and response Satisfactory procedures(SPRP) List of significant spills or leaks(for Satisfactory A list of onsite spills is kept digitally at the facility. the last 3 years) Solvent management plan (SMP) Satisfactory Preventative maintenance and good Satisfactory housekeeping program (PMGHP) Facility inspections conducted as Deficiency Per facility staff,facility inspections are conducted regularly required but were not recorded in the SWPPP. The facility should conduct and document quarterly facility inspections per the NCG06000 permit, Part B-11. Employee training (provided and Satisfactory Employee training was conducted and documented in June, documented) I October, and November of 2023. Qualitative/Analytical Monitoring Observed Comments Qualitative monitoring conducted as Satisfactory Qualitative monitoring was conducted and recorded as required required on 3/10/23, 6/30/23, 8/3/23, and 11/10/23. Analytical monitoring conducted as Satisfactory Analytical monitoring was conducted and recorded as required required on 3/10/23, 6/30/23, 8/3/23, and 11/10/23. Analytical monitoring for onsite Satisfactory Analytical monitoring for onsite vehicle maintenance was vehicle and equipment maintenance conducted and recorded as required on 3/10/23, 6/30/23, 8/3/ as required 23, and 11/10/23. Permit and Outfalls Observed Comments Copy of permit and certificate of Satisfactory NCG060175. coverage onsite All outfalls observed Yes No stormwater pollution issues were observed. Number of Outfalls Observed 3 Representative outfall status N/A documented by DEMLR Annual no-exposure self re-certificatio N/A n documented To report pollution or drainage problems call: 311 CHARIATTE. http://stormwater.charmeck.org 12/8/2023 12:17:09PM Page 3 of 3