Loading...
HomeMy WebLinkAboutWQ0015010_Monitoring - 11-2023_20231214Monitoring Report Submittal Permit Number#* Name of Facility:* Month: * November Report Information Type * GW-59 Confirmation Email Address: Name of Submitter: * Signature: Date of submittal: Initial Review WQ0015010 TDM Farm Truck Wash Year:* 2023 Upload Document* CCF_000041.pdf 815.66KB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). dniemond@hogslat.com Doug Niemond Reviewer: Wanda.Gerald 12/14/2023 This will be filled in automatically Is the project number correct?* WQ0015010 Is the monitoring report accepted?* Yes No Regional Office* Fayetteville Reviewer: _anonymous Review Date: 12/18/2023 CI MRAIT r:r)PK/l nK] YFI I r1W PAPER r11`111 Y DEPARTMENT OF ENVIRONMENTAL QUALITY • DIV. OF WATER RESOURCES GROUNDWATER QUALITY MONITORING: , � INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1 617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print CleartyorType PERMIT Number: Expiration Date: 4dik / S! ax Facility Name: TDM Farms Truckwash Non -Discharge WQ0015010 UIC "'K Permit Name (if different): NPDES Other Facility Address: Box 300 Newton Grove, NC 28366 TYPE OF PERMITTED OPERATION BEING MONITORED Box 300 Newton Grove, NC 28366 County Sampson El Lagoon ❑ Remediation: Infiltration Gallery Spray Field ❑ Remediation: Contact Person: Doug Niemond Telephone#: 910-590-6137 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: TDM Truckwash No. of wells to be sampled: 1 El Water Source Heat Pump ❑Other: from Permit If WELL SAMPLING INFORMATION �I rY WAS WELL ID NUMBER (from Permit): MW-1 Date sample collected: FIELD ANALYSES: °C DRY at Well Depth: 20.4 ft, Well Diameter: 2 in. pH 00400: 5.55 units Temp. 000lo: 17•� time ofsampling, Depth to Water Level 82546: 11.3 ft. below measuring point Screened Interval: 15 ft. to Z0 ft. Spec. Cond. 00094: µMhos Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor oom5: check Volume of water pumped/bailed before sampling: gallons Appearance here: ❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: X YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 11/17/2023 Laboratory Name: Waters Agricultural Certification No. NCWW#ND PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead o1051 ug/L Coliform: MF Fecal 31616 7.5 /100mL Nitrate (NO3) as N 00620 0.81 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 0.01 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 164.61 mg/L Al -Aluminum o1105 mg/L pH (Lab) 00403 7-6 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 0094o 41.00 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 0.04 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen, NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese o1055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOGs: mgtL tmuenr I oiat vuks: nryr� ,,.,. mwi—va. GW-59 Rev.3-1-2016