Loading...
HomeMy WebLinkAboutSW3230603_Supplement-EZ Form_20231215 SUPPLEMENT-EZ COVER PAGE ORMS LOADI PROJECT INFORMATION 1 Project Name Dollar General Store#25122 2 Project Area ac 2.61 3 Coastal Wetland Area ac 0 4 Surface Water Area ac 0 5 Is this project High or Low Density? Both High and Low Density 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided feet 30 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003 4 c-d? N/A 10 1 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration S stem 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 1 17 Rainwater Harvesting RWH 18 Green Roof 19 Level Spreader-Filter Stri LS-FS 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Ba filter 26 IFilterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Justin Church,PE-Principal Engineer 28 Or anization: BREC,PA 29 Street address: 1520 Meadowview Drive 30 City,State,Zip: Wilkesboro,NC 28697 31 Phone numbers : 336 844-4088 32 Email: justin@brec.biz Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer H CARO ''' Q SEAL < = Signature o Designer = 035736 = %vG�; NG I NEB C� r/N C. C 12/15/2023 Date DRAINAGE AREAS 1 Ils this a high density project? Yes 2 If so,number of drainage areas/SCMs 1 3 Does this roject have low density areas? Yes 4 If so number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 LID 1 4 T pe of SCM SAND FILTER 5 Total drainage area(sq ft 114,765 59,844 54921 6 Onsite draina a area(sq ft 113 880 58 959 54921 7 Offsite drainage area(sq ft 885 885 0 8 Total BUA in project(sq ft 45754 sf 44064 sf 1690 sf New BUA on subdivided lots(subject to 9permitting) s ft sf sf sf New BUA not on subdivided lots(subject to 10permitting) s 44869 sf 43179 sf 1690 sf 11 Offsite BUA(sq ft 885 sf 885 sf sf 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft 30070 sf 28380 sf 1690 sf -Sidewalk(sq ft 2005 sf 2005 sf sf -Roof(sq ft 12794 sf 12794 sf sf -Roadway s ft sf sf sf -Future(sq ft sf sf sf -Other,please specify in the comment box below(sq ft sf sf sf New infiltrating permeable pavement on 13 subdivided lots(sq ft sf sf sf New infiltrating permeable pavement not on 14 subdivided lots(sq ft sf sf sf Existing BUA that will remain(not subject to 15permitting) s ft sf sf sf 16 lExistina BUA that is already permitted (sq ft sf sf sf 17 Existing BUA that will be removed(sq ft 17389 sf sf sf 18 Percent BUA 39% 74% 3% 19 Design storm inches 1.0 in 20 Design volume of SCM cu ft 3264 cf 21 Calculation method for design volume SHULER ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): Entire Site/SCM parking BUA differ by 1,690 sq.ft.which is the portion of driveway stem that cannot be routed to SCM due to topographic limitations. We are requesting a variance for this portion as it does not meet low density threshold. There is also 885 sq.ft.of offsite drainage that cannot be he p LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 Are curb outlet swales proposed? 7 Maximum longitudinal slope of curb outlet swale(s)(%) 8 Bottom width of curb outlet swale(s)(feet) 9 Maximum side slope of curb outlet swale(s)(H:V) 10 Minimum length of curb outlet swale(s)(feet) 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 1 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 JAre variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 1piease use this space to provide any additional information about this low density project: Small portion of BUA in the driveway stem that cannot be routed to .V SCM. Swale BUA Drainage Pervious Q Slope V,,,a,,, , Flow depth # Area (ac) area C (cfs)acac (%) (fps) (fps) (ft) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SAND FILTER 11 Drainage area number 1 21 Minimum required treatment volume cu ft 2648 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? YFes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM H:V? 3:1 6 Does the SCM have retaining walls,gabion walls or other No engineered side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes 10- ear storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes desi n volume? 9 What is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with N/A General MDC 10? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 161 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed rofessional? Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) 794 19 Type of sand filter(open or closed) Open 20 If closed,will the filter will be pre-cast or pour-in-place? 21 If closed,top of grate elevation(fmsl) 22 Is this sand filter designed to attenuate peak flows? No Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 1632 cf 24 Will there be a permanent pool in the sediment chamber? Yes 25 Bottom of the sediment chamber(fmsl) 804.00 26 Area of the sediment chamber(square feet) 1270 sf 27 Physical depth of the sediment chamber(inches) 26.2 in 28 Ponding depth in the sediment chamber,above any permanent 13.2 in pool(inches) 29 Elevation of top of weir between chambers(fmsl) 806.1 Sand Chamber 30 Volume that can be retained in the sand chamber(cubic feet) 1632 cf 31 JlBottom of the sand chamber(fmsl) 805.00 32 Area of the sand chamber(square feet) 1270 sf 331 Physical depth of the sand chamber(inches) 13.2 in 34 Ponding depth in the sand chamber,above the sand surface 13.2 in (inches) 351 Elevation of the bypass device(fmsl) 806.1 36 Type of bypass device WEIR 37 Mechanism for distributing flow over the sand surface LEVEL SPREADER 38 Sand specification for sand chamber ASTM C33 39 Depth above underdrain pipe(inches) 14 in 40 Will the media be maintained to drain at least two inches per hour at Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes underdrain line? 42 WiII clean-out pipes be capped? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s): Sand Filter 4 12:01 PM 12/15/2023