Loading...
HomeMy WebLinkAboutSW4230801_Supplement-EZ Form_20231208 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name ACC Public Safety Training Center 2 Project Area(ac) 54.03 3 Coastal Wetland Area(ac) 0 4 Surface Water Area Sac) 3.46 _ 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 50 8 Will the vegetated setback remain vegetated? Yes - 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 1 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Garrett Frank,PE,PLA 28 Organization: Timmons Group 29 Street address: 5410 Trinity Rd,Suite 102 30 City,State,Zip: Raleigh,NC 27607 31 Phone number(s): (919)866-4505 32 Email: Garrett.Frankoetimmons.com _ Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer 0 0 '% 9 SEAL � 7 s Si a of esigner 2i¢E ( _ 055780 ifs r-z - f sea '�',,FTT W. 00, Date 4"rr,rr111111,,"*4 DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 1 3 Does this project have low density areas? No 4 If so,number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 4 Type of SCM Wet Pond 1 5 Total drainage area(sq ft) 2,353,547 925,179 6 Onsite drainage area(sq ft) 2,353,547 925,179 7 Offsite drainage area(sq ft) 0 0 8 Total BUA in project(sq ft) 400353 sf 360245 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) sf sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 400353 sf 360245 sf 11 Offsite BUA(sq ft) sf sf 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) 36309 sf 36040 sf -Sidewalk(sq ft) 4210 sf 3364 sf -Roof(sq ft) 18454 sf 18454 sf -Roadway(sq ft) 251123 sf 212130 sf -Future(sq ft) 80112 sf 80112 sf -Other,please specify in the comment box below (sq ft) 10145 sf 10145 sf New infiltrating permeable pavement on subdivided 13 lots(sq ft) sf sf New infiltrating permeable pavement not on 14 subdivided lots(sq ft) sf sf Existing BUA that will remain(not subject to 15 permitting)(sq ft) 31786 sf sf 16 Existing BUA that is already permitted(sq ft) sf sf 17 Existing BUA that will be removed(sq ft) sf 17309 sf 18 Percent BUA 17% 39% 19 Design storm(inches) 1.0 in 20 Design volume of SCM(cu ft) 30899 cf 21 Calculation method for design volume Simple ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): other BUA included as curb and gutter and stone paving under proposed gaurdrail. Future impervious includes all impervious associated with alternate#1 and#2. WET POND 1 Drainage area number 1 2 Minimum required treatment volume(cu ft) 30899 cf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered No side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion(10- Yes year storm)? _ 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? _ Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes If the SCM is on a single family lot,does(will?)the plat comply with 13 N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes WET POND MDC FROM 02H.1053 18 Sizing method used SA/DA 19 Has a stage/storage table been provided in the calculations? Yes 20 Elevation of the excavated main pool depth(bottom of sediment 608.50 removal)(fmsl) 21 Elevation of the main pool bottom(top of sediment removal)(fmsl) 609.50 22 Elevation of the bottom of the vegetated shelf(fmsl) 614.00 23 Elevation of the permanent pool(fmsl) 614.50 24 Elevation of the top of the vegetated shelf(fmsl) 615.00 25 Elevation of the temporary pool(fmsl) 616.20 26 Surface area of the main permanent pool(square feet) 13004 27 Volume of the main permanent pool(cubic feet) 46362 cf 28 Average depth of the main pool(feet) 4.06 ft 29 Average depth equation used Equation 3 30 If using equation 3,main pool perimeter(feet) _ 592.0 ft 31 If using equation 3,width of submerged veg.shelf(feet) 3.0 ft 32 Volume of the forebay(cubic feet) 8571 cf 33 Is this 15-20%of the volume in the main pool? Yes 34 Clean-out depth for forebay(inches) 6 in 35 Design volume of SCM(cu ft) 30899 cf 36 Is the outlet an orifice or a weir? Orifice 37 If orifice,orifice diameter(inches) 2.5 in 38 If weir,weir height(inches) 39 If weir,weir length(inches) 40 Drawdown time for the temporary pool(days) _ 3.4 41 Are the inlet(s)and outlet located in a manner that avoids short- Yes circuiting? 42 Are berms or baffles provided to improve the flow path? No 43 Depth of forebay at entrance(inches) 60 in 44 Depth of forebay at exit(inches) 48 in 45 Does water flow out of the forebay in a non-erosive manner? Yes 46 Width of the vegetated shelf(feet) 6 ft 47 Slope of vegetated shelf(H:V) 6:1 48 Does the orifice drawdown from below the top surface of the Yes permanent pool? 49 Does the pond minimize impacts to the receiving channel from the 1- Yes yr,24-hr storm? 50 Are fountains proposed?(If Y,please provide documentation that No MDC(9)is met.) 51 Is a trash rack or other device provided to protect the outlet system? Yes 52 Are the dam and embankment planted in non-clumping turf grass? Yes 53 Species of turf that will be used on the dam and embankment Bermuda 54 Has a planting plan been provided for the vegetated shelf? Yes ADDITIONAL INFORMATION ' 1 55 Please use this space to provide any additional information about the wet pond(s): Wet Pond 3 3:56 PM 11/29/2023