Loading...
HomeMy WebLinkAboutNCC233667_Site Plan or Location Map_20231213 ' / \ "\\ \ \ \ \� �SITF EGEND "EX.15'SETBACK // /•// ,1\ ��Xx�\ \�\ \ / / ■_ / / / /\ti \ \ APPROX.LOCATON \ "♦< YARDAGE LIGHTS TREE SAVE AREA / / /� / \ / / EASEMENT ny �/' / �\\ OF EX.10'X60'& / / / /' \I. \ TRIANGLE SIGHT .11 / / \//\ )l,i , TRIANGLES I / EX.56.25'CLASS 7 / / • < ) / L ` \ \ I / LIGHT POLE "B"LANDSCAPE ' / \/ / / BUFFER / EX.RIGHT OF WAY \ / / / // / /�\,� \ \ / POWER POLE 10'REAR YARD // / /-/ / / j,\\ \\/ '\`\ `(\ \ \\ `\ TRAFFIC DIRECTIONAL ARROW MCADAMS ^\ / // / / / ;O `��\ `� \ \ \\ ACCESSIBLE PARKING STALL The John R.McAdams Company,Inc. i /t5'wAIER LINE / / ��' \ \ \ VAN ACCESSIBLE PARKING STALL / / \ 621 Hillsborough Street EASEMENT / / / j \/ / / \ XX PARKING SPACE COUNT Suite 500 / / j • )// ( /,iRaleigh,NC 27603 ' / APPROX.LOCATION \/ \ OF EX.10X ACCESSIBLE RAMPS phone 919.361.5000 / / // • \ 1RIANG'SIGHfax 919.361.2269 / \ ttPE® NPEQB TYPE/ /• MENT DRAINAGE \ / \\ \ license number.C-0293,C-187 EX.PROPERTY LINE // /- / / \ \ ACCESSIBLE ROUTE / / / PROPERTY LINE WWWmcadamsco.Com / / / / - RIGHT-OF-WAY LINE\ CLIENT / / / . ND -/ / / / LOT LINEBOOSDEVELOPMEMT / / / \\ \ — — — — — EASEMEM LWE 410 PARK PLACE BLVD,SUITE 100 / • / - CENTERLINECLEARWATER,FL ' PHONE:866.42126679\ e A / NOSE DOWN CURB / / // -1_---------'/ \\ EX.CURB �\�\\ \\ \\\\/0T,y",Q \ / / /��. 7 _ --\ ••\ 0,. \\;\ \\. AL.`S \ 5_511A / /. /' / — \• \ \\\. \\5 6>1 \ CDOT NOTES: / r ,\ ' / / / COMMON DRIVEWAY \• \\ _ / / / / / / CORRIDOR \. . . _ \ '--� __ _ _ \` \` P� \ \\ \ 1. NON-STANDARD ITEMS(IE:PAVERS,IRRIGATION SYSTEMS,ETC)IN THE RIGHT-OF-WAY nOdWiII / / / //� i / �_--------\ �\ \ \` / \ \ REQUIRE ARIGHT-OF-WAY ENCROACHMENT AGREEMENT WITH THE CHARLOTTE 9 / / / / / / / \ \ \\ \N \�\ \ \\ \ DEPARTMENT OF TRANSPORTATION/NORTH CAROLINA DEPARTMENT OF TRANSPORTATION 7 / l ----_----- CONTACT KRVSTAL / / ,/ /% / I BRIGHT AT 704-336-38880R KRYSTAL.BRIGHT@CHARLOTTENC.GOV. \\\ \ilk\ 1 / /` / /, •/ / / / r L-I-- •\ _______—________— __—__—_—__--— E . ALK 2.x,5 EW \ Q DEVELOPER SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF Y / / / / / I 'y, \ \\\ \l' \\ \ TEMPORARY TRAFFIC CONTROL DEVICES DURING ALL PHASES OF CONSTRUCTION IN / �/ / / /- / /' / I I \\`\\\ CO.7'sl.. n\K \ \ ACCORDANCE WITH THE LATEST EDITIONS IF RMTRAF WORK AREADEVICES ED) J a / /. 1 I NW. \ @,, \ \ EASEMENT \ HANDBOOK(WATCH),THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES(MUTED),AND 7 / / / / / I 1 \ \ \ \ \ \ THE NCDOT ROADWAY STANDARD DRAWINGS./ / / / // / / / /• / I CC 1 \ \\\ \iiis\ \\\ \ 00 \ X -O-WAY \ 3. ANY WORK WITHIN THE CITY'S ROW OR CITY MAINTAINED INFRASTRUCTURE MUST BE //, / /. / / / I I ,1 11'I \ \ \ \\\ APPROVED BYCDOT AND WILL REQUIRE A ROW USE PERMIT OR ROW LEASE DEPENDING / / --- Z / _ - -- E PoLGHT F UPON THE PR ED SCOPE AND DURATION OF CLOSURE.THESE APPROVALS ARE N / / / / / I -- \\ ENTE LINE > o�nc t'496' \ \ \\ \ ADDITION TO LSIIE PLAN APPROVALS AND SHOULD BE COORDINATED WITH CDOT PRIOR TO 0 / / /�-_- -- -t 534.6]'2a'w \ \ \ \ \\ \ \\ CONSTRUCTION.CONTRACTOR SHALL CONTACT ERIC WEIDEMANN AT980-722-5463 OR /' EX.CURB AND / \\ \ 1 ERIC.WEIDEMANN@CHARLOTTENC.GOV AT LEAST 5 BUSINESS DAYS PRIOR TO BEGINNING GUTTER / //•// / / I PROPOSED LOT LINE �\ '1 I \ �\ \ \\ \ 1\\ WORK FOR IMPACTS LESS THAN 30 DAYS.CONTRACTOR SHALL CONTACT ANTHONY MENDEZ Ci- / / / /' / ,j \ \ \\ \ \\ AT 704-962-71730R ANTHONV.MENDE2@CHARLOTTENC.GOV AS SOON AS POSSIBLE FOR O / 1 \ gita , \\ \35' IMPACTS GREATER THAN 30 DAYS.EVERY EFFORT SHALL BE MADE TO CONSTRUCT I / / I ,lw1 , \ • 1 FUTU7('RIGHT OF WAY IMPROVEMENTSWITH MINIMAL IMPACTTOALL USERSOFTHE PUBLICROW./ / / I .10.5'PLANTING STRIP R �- \/ / / % I1 \\\\\\ '\\ \ 4. THEDEVELOPERSHALLCONTACTTHEIMPLEMENTATIONSECTIONMANAGER,TONY>' \ \ TAGLIAFERRI,OFTHECHARLOTTEDEPARTMENTOFTRANSPORTATION(CDOTIORTHEIR 46,909 SF 53T4I'}}''w ''l/ / / I RETAINING WALL WITH 1.08 AC Y.3 V1 \ � \ \\ DESIGNEE AT704-336-4119 TO IDENTIFYANY CONFLICTS WITH TRAFFICSIGNALIZATION4 _/�1 \ EQUIPMENT.60-90DAYS WILL BE REQUIRED TO COORDINATE RELOCATION.DEVELOPER Lrl/ / ISAFETY RAILING(DESIGN BY -/ 24'STANDARD CURB 1 \ \ \\ SHALL BE RESPONSIBLE FOR ALL RELATED RELOCATION COST AND/OR ANV REPAIR COST 'OWNER'S STRUCTURAL 1/ IAND GUTTER(TYP.) II• CAUSED BYTHE CONTRACTOR/DEVELOPER. J/ / I F R10' ENGINEER) I - \\D20'RASTOR EASEMENT // / I 1' FUTURE \ \ \ 5. PEDESTRIAN SCALE LIGHTING AND/OR STREET LIGHTING SHALL NOT BE INSTALLED WITHIN I \ THERIGHT OF WAYWITHOUTREVIEWANDAPPROVALOFCDOT.DEVELOPERTOCONTAR iTHOROUGHFARE \ \ FL�ITR \ W1 CANDACE INGE 70433639320R CANDACE.INGE CHARLOTTENC.GOV FOR LOCALSTREET/ IRIGHT-OF-WAY \ \ MNIM(J• .' ( @ I Q I \ SETBA6\ \ LIGHTING CRITERIA WITH RESIDENTIAL SUBDIVISION PROJECTS AND TO LLOTHE BRUCEW/' /_— - - - \ \ \ HGHTIN 1704-589-5836 0R BRUCE INATE T TH DUKE E ENC.GOVD CO ALL OTHER PROJERS/ / I 1 r I _- 4, I \ \ \ LIGHTING REQUIREMENTS.000RDINATE WITH DUKE ENERGY AND CDOT AS NECESSARYTO/ / I 10x50'LOADING \ DETERMINE LIGHTING LEVELS,LIGHTING LAYOUTAND REQUIREMENTS FOR INSTALLATION. I COLUMN(4) \ \/ / ./ / / / ILSPACESII_ \\`‘ \\\ 6. PRIVATEDEVELOPMENTUTILITYRELOCATIONCOORDINATION-FORUTILITYCOORDINATION l..)/ / \ \ \ RELATED TO BOTH EXISTING UTILITY RELOCATION NEEDS AND PROPOSED NEW UTILITY/ / JmLOADING DOCK \\ \\ INSTALLATIONS,PLEASE CONTACT RALPH TRUITT,CDOT ROW UTILITY COORDINATOR AT7/ ILTRASH COMPACTOR--- - CANOPY ROOFLIN _ \\ \ 15'sTORM \ \ \ \ \ 704-336-4248 OR RTRUITT@CHARLOTTENC.GOV. W (�/ I \`. \ '. EASEMENT \ \ \// / I \ \\\\\ \ \ 7. AJOINT USE MANHOLE(MEET-ME MANHOLE)ISTO BE PROVIDED BV THE DEVELOPER TO 7// / 1 SEE RCHITECTURAL \ X \ ACCOMMODATE ALL UTILITYTELECOM SERVICE PROVIDERS.THEIOINT USE MANHOLE SHALL WL// // / I \\\ \\ BE LOCATED ON PRIVATE PROPERTY OUTSIDE OF THE CITY RIGHT-OF-WAY. OI � �\ , \\ \ \ �\ oJ FWME \ \ �\ \Ih / / --- - � FIRE NOTES: NO //. % /1 F7DUMPSTER '\• // ,J / SRAMP AFETYRAIL NGS --_- \ 1. FIRE DEPARTMENT ACCESS ROADS SHALL BECAPABLE OF SUPPORTING 80,000 POUNDS.(SEE ARCHITECTURAL ,( 2. APPROVAL FOR BACKFLOW PREVENTION REQUIREMENTS IS NOT PART OF THIS REVIEW. /- //////��' PLANS) I \ I \\ BACKFLOW PREVENTION REVIEW ENTAILS PLAN SUBMITTAL VIA MECKLENBURG COUNTY'S 1Ji1I 6' EX.CURB ANCODE ENFORCEMENT PERMITTING PROCESS ATTHE TIME OF APPLICATION FOR BUILDING• ',IT I1 ', GUTTER • \1 x PERMITS.BACKFLOW PROGRAM REQUIREMENTS ARE AVAILABLE AT „r♦ /' ` http://charlottencgov/Water/Pages/Back9RwConstructionGuidelines.aspx.PLEASE ,J`.....CAR "3 _ / I I '\ CONTACT MARK KROUSE AT 704-032-5800 FOR MORE INFORMATION. a (N O� ' '/ I -t I \ 3. A 32005ERIES KNOX BOB IS REQUIRED IN ACCORDANCE WITH CHARLOTTE FIRE `� .... 9♦% ..L' / I I THE JOHN R. /// /////////////// r� �\ CHARLOTTE RELINES.COORDINATE INSTALLATION LOCATION WITH CITY OF O_ I / \ I CHARLOTTE FIRE DEPARTMENT. :m' Mc ADAMS 16= // II ' \ 7'33 1 ANY,INC.j /�(/� / los' BUILDING r—" R3 \ III Ii • ,,,tt C 0293 oti,, /•^I Cl) ,J COMMON DRIVEWAY N4.a /�I / 20,950 SF \ _ "I' CORRIDOR II '♦♦ H� .` o { �4a4L4r...♦♦♦♦♦i I /4 .. ... ... ..in CART CORRAL \/ SIN I �o`.VN CARp< ♦, RAILING �� I I S�O�` ESS/ /ti CANOPY(SEE Al/A322) Q� I3. _�OF ptiy 9',•- 0 Gal by Robe le TRANSFORMER / 0 26N Rab4 Wngate o AB 2 PROPOSED LOT LINE ` yy���`,f�-v-�'{�)(J(\� II = SEA ;egalagn� a 3 SURFACE MOUNTED BIKE PAD Rts' `10' \.•^' I e el gal®mceEameco com RACKS(4 SHORT TERM t sag i615et]2a I. KNOX BOX AND 2 LONG TERM MINIMUM la: ,''♦i pB p I N� G.,®/ EX 5'SIDEWALKr//////////// L — I� ' l ar, � ' __'' -'� ( REVISIONS I } 28 — REMAIN TOJ ! !! ! ! !!#• ifff � � �• !!liffiiflff•! !`!!� !!�!! i fly ®' f !!! \\\ / +- DATE vi REMAIN TIE-IN TO EXISTNG 8 I / SIDEWALK �� \\/ ——__/ N0. 11.111..2022 COORDINATION SET \ I o I J/ -- -- -- ----- Iv - 2 11.15.3012 1ST REVIEW CITY COMMENTS R15' 3 OS.16.2023 2N0 REVIEW CITY COMMENTS I / 1 CONCRETE PLANTER \ N3S'AISS1EJ ��` —J EX.CURB AND 1 1/ / EX.FLUSH CURB LMATCH EXISTING (TYP.) \ 24'.F -CURB I PROPOSED PAINTED I GUTTER --/ 1 A A V / CURB AND GUTTER CROSSWALK I 5 / �\ \ N B TRANSITION FROM(TO _ 6 o / STANDARD CURB AND GUTTER _ '' e / s' D,.za'FLUSH CURB(TOP.) / i 1/ / \ COMMON DRIVEWAYS L opY 201>v (( PAN NO. Bo0A220oON `l r ` _ PPROX.LOCATON / GUTTER \ V -, +-------- -OF SIGHT TRIANGLE CORRIDOR �G \ IIL / EX.CURB AND 1 EX.CURB AND \ I EX.CURB AND 'I _ _ --� - -'--" PROJECT J/ GUTTER GUTTER — - ___ FILENAME BOO 001 51 22 �i i �` //� Q 1-- 17 •I1 11I // rl� � DRAWN BY MKB \\ S /-- - / // SCALE 1"=20' PARKING / / \\ (��-O / DATE 09.30.2022 / FOR PR(p�POSEDLIZE� 0-if �EX.CURB AND T Q�y SHEET 72 / ��1$ , a'_f_ , I t II I ����������������� k y aa_ , - t. I I I 1 1, 411" PLAN / f o'4) ie Desi n�1I Constru \/\--l/ I 9 'Y J - GRAPHIC SCALE A 4uL.nerents-1 F- e.h.sv..WDr EX.CURB AND \ CompliancetINT R NpoI Mate y u lldin GUTTER .O 0 / 9 I I 34'FORCE MAIN EASEMENT 1� 4 Code.It Is Tile Respol�sibility Of The / Contractor IT ConNtrllct I his Protect l inch=20 k. / With Good Engineering Practice And I C 2 Carolina State Building Code.