HomeMy WebLinkAboutNCG550671_Compliance Evaluation Inspection_20231211 North Carolina Department of Environmental Quality Division of Water Resources
Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609
919.791.4200
December 11, 2023
Terri Scott
2625 Umstead Drive
Durham, NC 27712
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
General NPDES Permit NCG550000
Certificate of Coverage NCG550671
Facility: 2625 Umstead Road
Durham County
Dear Ms. Scott:
On November 28, 2023, Michael Hall from the Raleigh Regional Office visited your single-family
residence (SFR) wastewater treatment system to evaluate compliance with the subject General NPDES
Permit. The assistance provided by Ms. Whitney Conley during the inspection was greatly appreciated.
Our records indicate the treatment system consists of a septic tank, pump tank, sub-surface sand filter,
tablet chlorinator, common (with two other houses,) discharge pipe, and a rip-rap apron for post
aeration.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550671 authorize the
discharge of domestic wastewater from your treatment system to receiving waters designated as an
unnamed tributary to Sevenmile Creek (classified water supply IV, nutrient sensitive waters) in the
Neuse River Basin. The authorized discharge is in accordance with the effluent limits and monitoring
requirements established within the General Permit. The items below show what conditions were
noted at your facility:
Findings during the inspection were as follows:
1. During the inspection, Ms. Conley provided documentation showing that Scotty’s Septic
Service had pumped out the septic tank on March 7, 2022. The General NPDES Permit
requires the permittee to retain records associated with sewage disposal activities for a
period of at least 5 years.
2. Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine
tablets be maintained in the chlorinator to ensure proper disinfection of the discharged
wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful
bacteria from discharging to the environment. The product label for these tablets must
indicate the tablets are approved for wastewater use and not for swimming pools.
Part 1, Section D (1) of General NPDES Permit NCG550000 requires the permittee to
inspect the tablet chlorinator weekly to ensure there is an adequate supply of tablets for
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
North Carolina Department of Environmental Quality Division of Water Resources
512 North Salisbury Street 1611 Mail Service Center Raleigh, North Carolina 27699-1611
919.707.9000
continuous and proper operation. Section D (4) requires the permittee to maintain all
system components, including...disinfection units...at all times and in good operating
order. The inspector observed chlorine tablets in the chlorinator. Please continue to
ensure the correct type of tablets are used and maintained in the chlorinator as
required by the General NPDES Permit.
3. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements,
within General Permit NCG550000 requires a permittee to sample and analyze the
effluent leaving his/her treatment system prior to discharge annually. Parameters to be
sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total
Suspended Solids, Fecal Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia
Nitrogen and Total Phosphorous During the inspection, you informed the inspector that
the effluent has not been monitored within the last 12 months. Please collect a
representative sample of the effluent, have it analyzed by a certified commercial
laboratory and submit the results to this office no later than February 28, 2024. If,
during this time, you are unable to collect a representative sample of the effluent
discharge due to insufficient flow from the discharge pipe, then update this office with
that information and continue to monitor the discharge and if conditions for sampling
become favorable, then arrange to collect a sample. Failure to monitor the effluent
discharge as required is a violation of NPDES General Permit NCG550000.
4. Discharge outlet location. The permittee is required to conduct a visual review of the outfall
location at least twice each year (one at the time of sampling) to ensure that no visible solids or
other obvious evidence of system malfunctioning is observed. Any visible signs of a
malfunctioning system shall be documented and steps taken to correct the problem. The
discharge pipe was visible and accessible the day of the inspection. Please continue to ensure
the outlet is always visible/maintained and cleared of vegetation, soil and leaves.
Division records indicate the required annual fee ($60 per year) for the period ending September 30,
2024 and due October 4, 2023, has been paid. There are no overdue fees for the subject COC.
Please continue to periodically inspect the wastewater treatment system to ensure the treatment
components are always maintained and in good operating order. You are also reminded to maintain all
monitoring data and associated maintenance records onsite for a minimum of three years and
available for inspection.
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
North Carolina Department of Environmental Quality Division of Water Resources
512 North Salisbury Street 1611 Mail Service Center Raleigh, North Carolina 27699-1611
919.707.9000
If you have questions or comments about this inspection or the requirements to take corrective action
(if applicable), then please contact Michael Hall at 919-791-4237 or michael.hall@deq.nc.gov.
Sincerely,
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s): EPA Water Compliance Inspection Report
Field Inspection Form
Ec: Laserfiche
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
EPA
United States Environmental Protection Agency
Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NCG550671 23/11/28 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
2625 Umstead Road
2625 Umstead Rd
Durham NC 27712
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
01:02PM 23/11/28 21/11/24
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
01:19PM 23/11/28 25/10/31
Name, Address of Responsible Official/Title/Phone and Fax Number
Terri Scott,2625 Unstead Rd Durham NC 27712//540-314-3145/Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Operations & Maintenance Records/Reports Facility Site Review
Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Michael Hall DWR/RRO WQ/919-791-4237/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
12/11/2023
12/13/2023
NPDES yr/mo/day
23/11/28
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
On November 28, 2023, Michael Hall from the Raleigh Regional Office visited your single-family
residence (SFR) wastewater treatment system to evaluate compliance with the subject General
NPDES Permit. The assistance provided by Ms. Whitney Conley during the inspection was greatly
appreciated.
Our records indicate the treatment system consists of a septic tank, pump tank, sub-surface sand
filter, tablet chlorinator, common (with two other houses,) discharge pipe, and a rip-rap apron for post
aeration.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550671 authorize the
discharge of domestic wastewater from your treatment system to receiving waters designated as an
unnamed tributary to Sevenmile Creek (classified water supply IV, nutrient sensitive waters) in the
Neuse River Basin. The authorized discharge is in accordance with the effluent limits and monitoring
requirements established within the General Permit. The items below show what conditions were
noted at your facility:
Findings during the inspection were as follows:
1.During the inspection, Ms. Conley provided documentation showing that Scotty’s Septic Service
had pumped out the septic tank on March 7, 2022. The General NPDES Permit requires the
permittee to retain records associated with sewage disposal activities for a period of at least 5 years.
2.Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine tablets be
maintained in the chlorinator to ensure proper disinfection of the discharged wastewater. Chlorine
tablets provide effective disinfection and prevent/limit harmful bacteria from discharging to the
environment. The product label for these tablets must indicate the tablets are approved for
wastewater use and not for swimming pools. Part 1, Section D (1) of General NPDES Permit
NCG550000 requires the permittee to inspect the tablet chlorinator weekly to ensure there is an
adequate supply of tablets for continuous and proper operation. Section D (4) requires the permittee
to maintain all system components, including...disinfection units...at all times and in good operating
order. The inspector observed chlorine tablets in the chlorinator. Please continue to ensure the
correct type of tablets are used and maintained in the chlorinator as required by the General NPDES
Permit.
3.Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within
General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her
treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow,
BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform, Total Residual
Chlorine, Total Nitrogen, Ammonia Nitrogen and Total Phosphorous During the inspection, you
informed the inspector that the effluent has not been monitored within the last 12 months. Please
collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory
and submit the results to this office no later than February 28, 2024. If, during this time, you are
unable to collect a representative sample of the effluent discharge due to insufficient flow from the
discharge pipe, then update this office with that information and continue to monitor the discharge
and if conditions for sampling become favorable, then arrange to collect a sample. Failure to monitor
the effluent discharge as required is a violation of NPDES General Permit NCG550000.
4.Discharge outlet location. The permittee is required to conduct a visual review of the outfall
location at least twice each year (one at the time of sampling) to ensure that no visible solids or other
obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system
shall be documented and steps taken to correct the problem. The discharge pipe was visible and
accessible the day of the inspection. Please continue to ensure the outlet is always
visible/maintained and cleared of vegetation, soil and leaves.
NCG550671 17 (Cont.)
Page#2
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
Permit:NCG550671
Inspection Date:11/28/2023
Owner - Facility:
Inspection Type:
2625 Umstead Road
Compliance Evaluation
Division records indicate the required annual fee ($60 per year) for the period ending September 30,
2024 and due October 4, 2023, has been paid. There are no overdue fees for the subject COC.
Please continue to periodically inspect the wastewater treatment system to ensure the treatment
components are always maintained and in good operating order. You are also reminded to maintain
all monitoring data and associated maintenance records onsite for a minimum of three years and
available for inspection.
Page#3
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
Permit:NCG550671
Inspection Date:11/28/2023
Owner - Facility:
Inspection Type:
2625 Umstead Road
Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Septic Tank Yes No NA NE
(If pumps are used) Is an audible and visual alarm operational?
Is septic tank pumped on a schedule?
Are pumps or syphons operating properly?
Are high and low water alarms operating properly?
Ms. Conley provided invoice indicating that the septic tank had been pumped by
Scotty's Septic Service on March 7, 2023.
Comment:
Sand Filters (Low rate)Yes No NA NE
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filter free of ponding?
Is the sand filter effluent re-circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1)
Resident knew rough location of sand filter. No pooling or excessive growth was
observed in this area.
Comment:
Pump Station - Effluent Yes No NA NE
Is the pump wet well free of bypass lines or structures?
Are all pumps present?
Page#4
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
Permit:NCG550671
Inspection Date:11/28/2023
Owner - Facility:
Inspection Type:
2625 Umstead Road
Compliance Evaluation
Pump Station - Effluent Yes No NA NE
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Resident indicated that pump system had been recently overhauled, following an
overflow event.
Comment:
Disinfection-Tablet Yes No NA NE
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Number of tubes in use?2
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de-chlorination?
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Residence discharges to common effluent pipe for two other houses.Comment:
Page#5
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0
DocuSign Envelope ID: D78FC39E-51C0-4D22-AAEA-63D041097CD0