Loading...
HomeMy WebLinkAbout440011_Inspection_20230928 (2)Division of Water Resources Division of Soil and Water Conservation Other Agency Facility Number: Inactive Or Closed Date: Region: Owner:Phone: Mailing Address: Physical Address: Facility Status: Location of Farm: 111 Owens Rd 295 Holstein Farm Rd Compliant Not Compliant Integrator: Latitude:Longitude: Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application Records and Documents Question Areas: 35° 35' 05''83° 01' 18'' 440011 Active AWC440011 Compliance Inspection Routine Haywood Asheville Facility Status:Permit:Denied Access Inspection Type: Reason for Visit:County: Date of Visit:09/28/2023 Entry Time:10:00 am Exit Time:11:00 am Incident #: Farm Name:H. Dean Ross Farm Owner Email: H Dean Ross 828-926-3460 Waynesville NC 287859668 Waynesville NC 28785 Joe Carver Rd. (SR 1322) off NC 276 Jonathan Creek, right on (SR 1323) Owens Road, right on Holstein Farm Rd. Certified Operator: Secondary OIC(s): Operator Certification Number: Hobert D Ross 21954 On-Site Representative(s):Name Title Phone 24 hour contact name Ronnie Ross 828-507-3151 Primary Inspector:Phone: Inspector Signature:Date: Secondary Inspector(s): Timothy R Fox Inspection Summary: Tim Fox with ARO inspected the site. November 2015 Dairy shut down. 8th year with no confined cattle. No land application since spring 2016. Permit recission options have been discussed during previous inspections. AWB 21954 6 CE hrs needed by 1/1/2025. Page 1 of 5 Permit:AWC440011 Inspection Date:09/28/23 Owner:H Dean Ross Inspection Type:Compliance Inspection Facility Number: Reason for Visit: 440011 Routine Current promotionsDesign CapacityRegulated Operations Cattle Cattle - Milk Cow 300 0 Total Design Capacity: Total SSLW: 300 420,000 Waste Structures Observed Freeboard Designated Freeboard Closed Date Built DateIdentifierType Effective Date Waste Pond WASTE STORAGE POND 01/01/1996 21.60 21.0001/17/2000 Page 2 of 5 Permit:AWC440011 Inspection Date:09/28/23 Owner:H Dean Ross Inspection Type:Compliance Inspection Facility Number: Reason for Visit: 440011 Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? Discharge originated at: Structure Application Field Other a. Was conveyance man-made? b. Did discharge reach Waters of the State? (if yes, notify DWQ) c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the State other than from a discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? If yes, is waste level into structural freeboard? 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large trees, severe erosion, seepage, etc.)? 6. Are there structures on-site that are not properly addressed and/or managed through a waste management or closure plan? 7. Do any of the structures need maintenance or improvement? 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or improvement? 11. Is there evidence of incorrect application? If yes, check the appropriate box below. Excessive Ponding? Hydraulic Overload? Frozen Ground? Heavy metals (Cu, Zn, etc)? PAN? Is PAN > 10%/10 lbs.? Total Phosphorus? Failure to incorporate manure/sludge into bare soil? Outside of acceptable crop window? Evidence of wind drift? Application outside of application area? Crop Type 1 Corn (Silage) Page 3 of 5 Permit:AWC440011 Inspection Date:09/28/23 Owner:H Dean Ross Inspection Type:Compliance Inspection Facility Number: Reason for Visit: 440011 Routine Waste Application Yes No NA NE Crop Type 2 Small Grain (Wheat, Barley, Oats) Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Soil Type 2 Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? 17. Does the facility lack adequate acreage for land application? 18. Is there a lack of properly operating waste application equipment? Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check the appropriate box below. WUP? Checklists? Design? Maps? Lease Agreements? Other? If Other, please specify 21. Does record keeping need improvement? If yes, check the appropriate box below. Waste Application? Weekly Freeboard? Waste Analysis? Soil analysis? Waste Transfers? Weather code? Rainfall? Stocking? Page 4 of 5 Permit:AWC440011 Inspection Date:09/28/23 Owner:H Dean Ross Inspection Type:Compliance Inspection Facility Number: Reason for Visit: 440011 Routine Records and Documents Yes No NA NE Crop yields? 120 Minute inspections? Monthly and 1" Rainfall Inspections Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? 24. Did the facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate box(es) below: Failure to complete annual sludge survey Failure to develop a POA for sludge levels Non-compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? Page 5 of 5