Loading...
HomeMy WebLinkAbout110006_Inspection_20231206 0 Division of Water Resources ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 110006 Facility Status: Active Permit: AWC110006 ❑ Denied Access Inspection Type:Compliance Inspection Inactive Or Closed Date: Reason for Visit:Routine County: Buncombe Region: Asheville Date of Visit: 12/06/2023 Entry Time: 10:00 am Exit Time: 11:30 am Incident#: Farm Name: T&C Dairy Owner Email: Owner: George A Nesbitt Phone: 828-628-2852 Mailing Address: PO Box 936 Fletcher NC 287320936 Physical Address: 440 Lower Brush Creek Rd Fletcher NC 28732 Facility Status: 0 Compliant ❑ Not Compliant Integrator: Location of Farm: Latitude: 35'28'35" Longitude: 82'26'05" 436 Lower Brush Creek Rd, Fletcher.4 miles SW of Fairview, 6 miles east of Fletcher, turn at Oak Baptist Church on to Lower Brush Creek Rd. Go to dirt Rd 4th drive on left. Question Areas: Dischrge&Stream Impacts Waste Col, Stor, &Treat Waste Application Records and Documents Certified Operator: George A Nesbitt Operator Certification Number: 21355 Secondary OIC(s): On-Site Representative(s): Name Title Phone 24 hour contact name Tony Nesbitt 828-628-1956 Primary Inspector: Timothy R Fox Phone: Inspector Signature: Date: Secondary Inspector(s): Inspection Summary: Tim Fox with ARO inspected the site. Tony Nesbit was present during the inspection. Calibration due again in 2025. Soils done in 2021 due in 2024. Spot checked Meadowa#11 Field size 13. Plan to eliminate dairy cows by next year and evaluate new livestock(beef cattle)option. 6 continuing education hours needed by 1/1/2025. Page 1 of 5 Permit: AWC11000E Owner: George A Nesbitt Facility Number:110006 Inspection Date:12/06/23 Inspection TypeCompliance Inspection Reason for Visit:Routine Regulated Operations Design Capacity Current promotions Cattle Cattle- Milk Cow 300 I 80 Total Design Capacity: 300 Total SSLW: 420,000 Waste Structures Effective Built Closed Designated Observed Type Identifier Date Date Date Freeboard Freeboard Waste Pond SLURRY POND 01/01/1996 I D1/01/1989 22.80 Page 2 of 5 Permit:AWC11000E Owner: George A Nesbitt Facility Number:110006 Inspection Date:12/06/23 Inspection TypeCompliance Inspection Reason for Visit:Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ MEIEI Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ 0 ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ 0 ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ 0 ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ 0 ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the ❑ 0 ❑ ❑ State other than from a discharge? Waste Collection, Storage &Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ 0 ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc ❑ 0 ❑ ❑ trees, severe erosion, seepage, etc.)? 6. Are there structures on-site that are not properly addressed and/or managed through a ❑ 0 ❑ ❑ waste management or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ 0 ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE ❑ 0 ❑ ❑ to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ ❑ ❑ maintenance or improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ 0 ❑ ❑ maintenance or improvement? 11. Is there evidence of incorrect application? ❑ 0 ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Page 3 of 5 Permit:AWC11000E Owner: George A Nesbitt Facility Number:110006 Inspection Date:12/06/23 Inspection TypeCompliance Inspection Reason for Visit:Routine Waste Application Yes No NA NE Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Soil Type 2 Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste ❑ 0 ❑ ❑ Management Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ 0 ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre ❑ 0 ❑ ❑ determination? 17. Does the facility lack adequate acreage for land application? ❑ 0 ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ 0 ❑ ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ 0 ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ 0 ❑ ❑ If yes, check the appropriate box below. WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? ❑ ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ Crop yields? ❑ Page 4 of 5 Permit:AWC11000E Owner: George A Nesbitt Facility Number:110006 Inspection Date:12/06/23 Inspection TypeCompliance Inspection Reason for Visit:Routine Records and Documents Yes No NA NE 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ 0 ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipmen ❑ 0 ❑ ❑ (NPDES only)? 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ 0 ❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the ❑ 0 ❑ ❑ appropriate box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non-compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ 0 ❑ ❑ 27. Did the facility fail to secure a phosphorous loss assessment(PLAT) certification? ❑ 0 ❑ ❑ Page 5 of 5