Loading...
HomeMy WebLinkAboutWQ0044868_Application (FTSE)_20231103 NC Dept of;�;nvlr0nmel.tal Quality State of North Carolina Department of Environmental Quality OCTDWR 2 6 Division of Water Resources Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Ral-;-b Reglopl-i ,%ll,.- FTA 06-21 &SUPPORTING DOCUMENTATION Application Number:(,(� 020q(!3(�Ito be comploed by D") All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Mebane(company,municipality,HOA,utility,etc.) 2. Applicant type: ❑ Individual ❑Corporation ❑General Partnership ❑ Privately-Owned Public Utility ❑Federal ❑ State/County ®Municipal ❑Other 3. Signature authority's name:Chris Rollins per 15A NCAC 02T 0106(b) Title:City Manager 4. Applicant's mailing address: 106 E. Washington Street City:Mebane State:NC Zip: 27302 5. Applicant's contact information: Phone number:(919)562-5901 Email Address:crollinsftityormebanc.conn It. PROJECT INFORMATION: 1. Project name:Montclair Subdivision 2. Application/Project status: ® Proposed(New Permit) ❑ Existing Permit/Project If a modification,provide the existing,permit number: WQ00 and issued date: , For modifications,also attach a detailed narrative description as described in Item G of the checklist. If new construction,but part of a master plan,provide the existing permit number:WQ00 3. County where project is located:Orange County 4. Approximate Coordinates(Decimal Degrees): Latitude: 36.089534 ' Longitude:-79.258498' 5. Parcel ID(if applicable): 9825-31-5555(or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer:William R.Wirt License Number:052574 Firm:Summit Design and Engmccnna Services Mailing address: 320 Executive Court City:Hillsborough State:NC Zip:27278 Phone number:(919)732-3883 Email Address:wilham wirtAsummitde.com IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION: 1. Facility Name:City of Mebane Water Resource Recovery Facility Permit Number:NCO021474 Owner Name:City of Mebane V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ Unknown(Existing Sewer over 50 Years Old) 2. Downstream(Receiving)Sewer Information: 8 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s)(if applicable): WQCS00081_ Owner Name(s):City of Mebane FORM: FTA 06-21 Page I of 5 Vt. GENERAL REQUIREMENTS 1. If the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been attached? [—] Yes [:]No ®N/A 2. If the Applicant is a Developer of lots to be sold,has a Developer's Operational Agreement(FORM: DEV)been attached? ❑Yes ❑No ®N/A 3. If the Applicant is a Home,'Property Owners'Association,has an HOA/POA Operational Agreement(FORM: HOA)and supplementary documentation as required by 15A NCAC 02T.01 15(c)been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ® Residential(Individually Owned) ❑ Retail(stores,centers,malls) ❑Car Wash ❑ Residential(Leased) ❑ Retail with food preparation;'service ❑ Hotel and/or Motels ❑ School!preschool r day care ❑ Medical/dental/veterinary facilities ❑ Swimming PooliClubhouse ❑ Food and drink facilities ❑Church ❑ Swimming Pool./Filter Backwash ❑ Businesses 'offices.,'factories ❑Nursing Home ❑ Other(Explain in Attachment) 5. Nature of wastewater: 100%Domestic 0%Commercial 0%Industrial(See 15A NCAC 02T.0103(20)) If Industrial, is there a Pretreatment Program in effect?❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 021.0114(f)? ® Yes ❑ No ➢ If yes,provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type(see 02T.0114(f)) Daily Design Flow°," No.of Units Flow 4 BR Single Family/80 gpd/BR 320 gal/day 6 1,920 GPD gal/ GPD gall GPD gal/ GPD gal/ GPD gal/ GPD Tota! 1,920 GPD a See 15A NCAC 02T .0114(b). (d), (e)(1)and(e)(2) for caveats to wastewater design flow rates(i.e., minimum flow per dwelling;proposed unknown non-residential development uses;public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.42A-4). b Per 15A NCAC 02T.0114(c),design flow rates for establishments not identified[in table 15A NCAC 02T.01 141 shall be determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data. 8. Wastewater generated by project: 1,920 GPD(per 15A NCAC 02T.01 14) Do not include future flows or previously permitted allocations If permitted flow is zero,please indicate why: ❑ Pump Station./Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑Other(Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA(If Applicable)-02T.0305& MDC(Gravity Sellers): I. Summarize gravity sewer to be permitted: Size(inches) Length(feet) Material 8" 542.51 LF PVC 8" 143.34 LF DIP D Section II&III of the MDC for Permitting of Gravity Sewers contains information related to design criteria D Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA(If Applicable)—02T.0305& MDC(Pump Stations,Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: 2. Approximate Coordinates(Decimal Degrees):Latitude: Longitude:- 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day(firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s)per pump(s): gallons per minute(GPM)at feet total dynamic head(TDH) 5. Summarize the force main to be permitted(for this Pump Station): Size(inches) Length(feet) Material If any portion of the force main is less than 4-inches in diameter,please identify the method of solids reduction per MDCPSFM Section 2.01C.1.b. ❑Grinder Pump ❑ Mechanical Bar Screen ❑Other(please specify) _ 6. Power reliability in accordance with 15A NCAC 02T 0305(h)(1): ❑ Standby power source or ❑ Standby pump Must have automatic activation and telemetry- 15A NCAC 02T.0305(h)(1)(B)_ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation,quick-connection receptacle and telemetry- or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: D Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. D If the portable power source or pump is dedicated to multiple pump stations,an evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump,including travel timeframes,shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS&SEPARATIONS (02B.0200& 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations/altematives found in 15A NCAC 02T.0305(f)&Igl? ®Yes ❑No 15A NCAC 02T.0305(f)contains minimum separations that shal I be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below(vertical) 24 inches 'Water mains(vertical -water over sewer preferred,including in benched trenches) 18 inches 'Water mains(horizontal) 10 feet Reclaimed water lines(vertical-reclaimed over sewer) 18 inches Reclaimed water lines(horizontal-reclaimed over sewer) 2 feet "Any private or public water supply source,including any wells,WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water,and associated wetlands. 100 feet **Waters classified WS(except WS-I or WS-V),B,SA,ORW,HQW,or SB from normal high water(or tide elevation)and wetlands associated with these waters(see item IX.2) 50 feet **Any other stream,lake,impoundment,or ground water lowering and surface drainage ditches,as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation(horizontal) 5 feet Any basement(horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade(vertical) 36 inches ➢ If noncompliance with 02T.0305(t)or see Section X.1 of this application "1 SA NCAC 02T.0305(,;)contains alternatives where separations in 02T.0305(f)cannot be achieved. Please check`yes" above if these alternatives are used and provide narrative information to explain. "Stream classifications can be identified using the Division's NC Surface Water Classifications weboaue 2. Does this project comply with the minimum separation requirements for water mains? ®Yes ❑No ❑N/A ➢ If no,please refer to 15A NCAC 18C.0906(f)for documentation requirements and submit a separate document, signed/sealcd by an NC licensed PE,verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑Yes ❑No ®N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name:Jordan Lake ❑No If yes,does the project comply with setbacks found in the river basin rules per 15A NCAC 0213.02001 ®Yes ❑No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑Yes ®No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with I SA NCAC 02T 0105(c)(6)(additional permits/certifications)? ®Yes ❑No Per 15A NCAC 02T.0I05(c)i6),directly related environmental permits or certification applications must be being prepared, have been applied for,or have been obtained.Issuance of this permit is contingent on issuance of dependent permits(erosion and sedimentation control plans,stormwater management plans,etc.). 7. Does this project include any sewer collection lines that are deemed"high-priority?" ❑Yes ®No Per 15A NCAC 02T 0402,"high-priority sewer"means any aerial sewer,sewer contacting surface waters, siphon,or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes,include an attachment with details for each line,including type(aerial line,size,material,and location). High priority lines shall be inspected by the permittee or its representative at least once every six-months and inspections documented per 15A NCAC 02T.0403(a)(5)or the permittee's individual System-Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum D_esign Criteria for the Permitting of Pump Stations and Force Mains(latest version m,and the Gravity Sewer Minimu Design Criteria(latest version as applicable? ®Yes ❑No if no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times.For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the pronect,the full technical review is re uired. 2. Professional Engineer's Certification: 1,WILLIAM R.WIRT,attest that this application for Montclair Subdivision (Professional Engineer's name from Application Item I I) (Project Name from Application Item Il 1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,engineering calculations,and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for GraNity Sewers(latest version),and the Minimum Desi'un Criteria for the Fast-Track Permitting of Pump stations and Force Mains(latest version. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000,as well as civil penalties up to$25,000 per violation.Misrepresentation of the application information,including failure to disclose any design non-compliance with the applicable Rules and design criteria,may subject the North Carolina-licensed Professional Engineer to referral to the licensing board.(21 NCAC 56.0701) North Carolina Professional Engineer's seal,signature,and date: 5?J5705 _ ' 14 M R \\`��� '11101illlrr00 3. Applicant's Certification per 15A NCAC 02T.0106(b): 1, CHRIS ROLLINS CITY OF MANAGER,attest that this application for Montclair Subdivision (Signature Authority Name from Application Item 1.3.) (Project Name from Application Item 11.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included,this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non-discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,injunctive relief,and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes :43-215.6A and 143 215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000 as well as civil penalties up to$25,000 per violation. Signature: �WLDate: FORM: FTA 06-21 Page 5 of 5 ;dC fleet g 1✓nvjIon ►etltaIQ0IA State of North Carolina Department of Environmental Quality Division of Water Resources DWR Division of Water Resources Flow Tracking for Sewer Extension Applications aml Office (FTSE 10-18) Entity Requesting Allocation: City of Mebane Project Name for which flow is being requested: Montclair Subdivision More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: City of Mebane WWTP _ b. WWTP Facility Permit#: NC0021474 All flows are in MGD c. WWTP facility's permitted flow 2.5 d. Estimated obligated flow not yet tributary to the WWTP 0.4414 e. WWTP facility's actual avg. flow 1.6000 f. Total flow for this specific request 0.0019 g. Total actual and obligated flows to the facility 2.0433 It. Percent of permitted flow used 82% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)—(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity,* (Firm!pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow,MGD MGD Flow Capacity*** *The Firm Capacity(design flow)of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf)not less than 2.5,per Section 2.02(A)(4)(c)of the Minimum Design Criteria. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is<0. Downstream Facility Name(Sewer): City of Mebane Downstream Permit Number: NC0021474 Page 1 of 6 FTSE 10-I8 III. Certification Statement: I Chris Rollins certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has a equate capacity to transport and treat the proposed new wastewater. �Lql 1 4011-1.1 __ q r 3 20 23 Signing Official Signature Date /Vluna -e v" _ Title of Signing O tcial Page 2 of b FTS F 10-18 A.*....mow► � NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H,Sullins Dee Freeman Governor Director Secretary March 15, 2011 Robert L. Wilson NC Dept(A Environmental Quality City Manager City of Mebane 106 East Washington Street Mebane,NC 27302 Subject: Mebane WWTP (NC0021474) Rale�gl�Regional Office Flow Reduction Request Alamance County Dear Mr. Wilson: On February 14, 2011, the Pretreatment, Emergency Response and Collection System (PERCS) Unit of the Division of Water Quality received a flow reduction request for connections to the City of Mebane WWTP. The letter requests an allowable flow rate of 80 gallons per day(gpd) per bedroom based on the evaluated data. As daily WWTP data is not representative of the project area, the DMR data from the City of Mebane WWTP (NC0021474) from January 2009 through December 2009 was evaluated to determine the peak sewage month. The highest flow month was December 2009. Daily wastewater flows were recorded downstream of the Holly Ridge Subdivision during December 2010. This data was reviewed by PERCS and Regional Office staff: Based on the data, the Division hereby grants a reduction in flow to 80 gpd/bedroom (minimum of 160 gpd for 1 and 2 bedroom residences) for sewer extension permits issued tributary to the City of Mebane WWTP. Regardless of the adjusted design daily wastewater flow rate, at no time shall the wastewater flows exceed the effluent limits defined in the NPDES permit for the treatment facility or exceed the capacity of the sewers downstream of any new sewer extension or service connections . If you have any questions or comments regarding this matter, please contact Sarah Morrison at (919) 807-6310, or email [Sarah.Morrison@ncdenr.gov] or Deborah Gore, Unit Supervisor at (919) 807-6383, or email [Deborah.Gore@ncdenr.gov]. Sincerely, Coleen H. Sullins cc: Darrell L.Russell,P.E.,Alley,Williams,Carmen&King,Inc (via email:dnmwll@awck.com) Steve Mauney,Winston-Salem Regional Office(via email) NPDES Unit, Permit File NCO021474 PERCS Flow Reduction File 1617 Mail Service Center,Ralegh,North Carolina 2 7699-1 61 7 Location:512 N.Salisbury SL Raleigh,North Carolina 27604 ne Phone:919-807-M\FAX:919-807-6492 4 PERCS Unit FAX:919-807-6489 Customer Service 1-877-62M746 NocorthCarofina Internet:hltnlloortaLnodenr.oraN+etXwd PERCS Unit:htW:ilportal.ncdenr.oMlwebAW$wolp9lpmt atura!!� An Equal Opportunity 1 Affirmative Action Employer 4 Ph 41t�cigh RegionalOff , 44 IYIN A/• 3 a ice a �vl 0 It * 4 0 fr lw 0.. 4%44 S141TH RD 0, 0 ----------- 5 All* 461 A0, 7 TH Sr Fk iem �Dl 3�O 7 S TATE 5 1 rH ST me)M TFrFf r)A VF t d� ® ` OAKDALEAVE ASHOURY OLVD-'-,, 4W. ME mm 4 D I Go :gle Maps 'saaA —O sr M FCC mooffs Sr SarNaH O wa.re. ,yam Q Fat Man AHis Food ,Ma_ N Y . v z OPersonanimin g �►-:' Persdnal rrawng doe Lanes Mebane � EC�h toy Boedmg center� ., �� _ h v ._ Mdes r,era!H,_.ne 9 Foust Corner market Altordable Blinds BootkeepBalailng l IN y*I s" Mgr S7 _�[-�fAh4_y_y bo.l er zEspr:ss mQ v Oai«ood Cemetery. -� Oranges SCq o e Homes by Paul 04l Q v E Cam,jf AA�a�tra. N -eAp ReallyJr r G,aMR ceVScy r'gfan� �s Y.7Q >�rat 9[ndoW All$petlahl Ch F`v F Waah�t.A � .. fJa�r�& yd} E ®-rude Line Fie Fit King tire Plot q, y f: C B o` ; 4 •� Mebane First N Baptist Church VA t 3 Apartments y cedar Hal 9fti 0 If E webb St Ilet Willits 4 w • B � ElmwoodAparunents� 4 Aqua DesignsQ h $Inn Vw Cl A �•RRMeln Go-.glit Map data @2023 Google 200 ft■ 9fe�sP NC Dept of Environmental Quality +•aE Lp�i UNITED STATES STATE OF NORTH CAROLINA Nov 22023 MEBANE QUADRANGLE DEPARTMENT OF THE INTERIOR DEPARTMENT OF CONSERVATION AND DEVELOPMENT Raleigh Regional Office NORTH CAROLINA aura i GEOLOGICAL SURVEY RALEIGH,NORTH CAROLINA 7.5 MINUTE SERIES(TOPOGRAPHIC) c 6rx79°22'30" sW°I W8 To wc ea 20' `51 ° EEEt 7 36°07'30" — 6 60730 ' r � !�_� 1� _ _ - N REGIONAL PUMP 6U' `- — STATION In- S G ���Y 1198--R �, " l�1�C7 '� �;�h•I FORCE MAIN a" ■ • 1 <I � gar�a6D 0oD •�: l' P- I - i/W�,. . .� •9 ;FEET "w �, •�� A W97S G I+ )`All _ �VI�•" __ x�962 ■ / �- � �I,>� ->. :;. � �%' •� �, �� �_ � � •. ��1.� . �- ,lift N9fi 'vte ban ( r96 l `� P��a S.a _ -- V U ■ - _ 1 x n Ap. .. aY . Dx � .�, °..! �: `.• ate Knel - NC0021474 ♦. � i $ SITE c lE� 5 -gip`-✓ �--� 1 r .�,�' �. �_ IC , \ s,r \\�� \�l- //�. •„ �I}�J.P1 � 5. -94 :•I o � ��l� r' •.elDrent.T—i i C ` 4/1 sip // T. IJ _J Mso 230 / - � /• j ` \ 7 1 1 �'` 2'30„ 112 Im f o C 1 ♦ M Ik ss^r` r`�` ( \ ��� ✓`l� � Lid, V I 1 Ng7 �. 1. � \� _ � //✓ r' I sez• it : lags �n - �J •�• Al O 1 III W - - 820000 ��. rs8 ✓� FEET% I/ r �jl a 36.00 ' r in • `T 36'00' 79°22'30" 1890000 FEET IM 20' s51 651 155 Mapped,edited,and published by the Geological Survey SCALE 1.24000 Control b USGS and USC&GS • IE ROAD CLASSIFICATION ui y # O Primary highway, Light4uty road,hard o F Topography by photogrammetric methods from aerial lose o loop acci laaD A000 Soon Edon 7"FEET i p 2:C photographs taken 1967. Fleld hacked!1969 oMETER Serconda ylti hwa m roved Surface t°ms ry ,8 Y. Polyconit protection. 1927 North American datum s o hard surface Unimpr°ved•r0ad =-------. TI 10,0004—grid based on North Carolina coordinate system MI MILS CONTOUR IN TERVAL 10 FEET 1000-meter Universal Transverse Mercator grid ticks, DATUM IS MEAN SEA LEVEL Interstate Route 0U.S.Route OState Route 7 e 17,shown In blue Red tint indicates area in which only landmark buildings are shown .E="ON A"c_t.of sNsrr QUADRANGLE LOCATION MEBANE,N.C. THIS MAP COMPLIES WITH NATIONAL MAP ACCURACY STANDARDS �II�� N3600—W7915/7.5 FOR SALE SY U.S.GEOLOGICAL SURVEY,WASHINGTON,D.C.20242 USGS ISTORICN! A FOLDER DESCRIBING TOPOGRAPHIC MAPS AND SYMBOLS IS AVAILABLE ON REQUEST HISTORICAL FILE 1969 7�D TOPOGRAPHIC DIVISION AMS 5156 If SE—SERIES Ve42 I Mill Creek Golf Club 9 NC Dept of Environmental'Quality Nov 3 2023 Raleigh Regional Office T •, t3�6 0 Lake M Mebane Electrical Services I --i Mebane Community Park =�✓/ PROPOSED SEWL-kane FOR DEVELOMENT Buffaloe I-anes Meban Family Bowling Center EXISTING MH EXISTING ©Mebane Arts& SEWER LINE r+.—rnimiN Cel.L- NC Dept of Environmental Quality m Nov 32023 UTILITIES LEGEND: Raleigh Regional Office EXIST/ PROPOSED NOW OR FORMERLY Q P\ H W N WATER VALVE ❑ W ALAMANCE PROPERTY GROUP,LLC. \ GWINNLINDAD W N P/N:986724 224 I Y FIRE HYDRANT PIN:9825.31.2726 Il! DBPG:6724/2248 NOW E FORMERLY R' I []w 0 WATER METER DB/PG:545/555 to W SINGLE FAMILYRESIDENCE KENNESHFISHERB = 0.12AC => 0.35AC JAOUELINE SHELTON GREEN O Y FIRE DEPT.CONNECTION(FDC) ZONE:R-I2-RESIDENTIAL Z ZONED R-12 PIN:9825.31.479] SINGLE FAMILY RESIDENCE ESPITIA PROPERTIES LLC REDUCER I :9825.41.0961 0.35 AC PIN PLUG&BLOCK W ZONED R-12 DB 6708/1354 MECHANICAL JOINT/BEND 8.35 AC 1- as 11UIR[o 'pG 10'SIDE ZONE:R8(CD)-RESIDENTIAL CONDITIONAL I^ POST INDICATOR VALVE(PIV) SETBACK EX TPED a AIR RELEASE VALVE(ARV) Z an -HA-0- Tin 0INr PP ^ _ — — — — — — — - SANITARY SEWER MANHOLE N roN riNR� 133.06' 135.00' I -- - _ _ O c • SEWER CLEAN OUT > = .. ---------- J i- IXFH ® CURB INLET x $ I +w ENE EX ® DROP INLET 4,653 SF PRIVATE LOT 1 w PP 8842 SF ro 0 Q JUNCTION BOX WOODYELIZABETH S - \ \ O" COMMON OPEN PACE I FLARED END SECTION FE 0.2030 AC u� n' PIN:9825.31.3]14 732.85' w ( S) DBIPG:656 11690 \ zs - - - �E w FFE�1I&P 30 4 P 0.01 AC seTsncrc S88°56' 52"W m r w w EXISTING WATER MAIN a - CRAWL SPACE w PROPOSED WATER MAIN/SERVICE V ZONE:R-12-RESIDENTIAL O I r---------- o Ni x NOW OR FORMERLY 0�1 NOTE:LOT6ACCESS 2 N88°31' 44"E CEDAR HILL APARTMENTS,LLC. c c EXISTING GAS MAIN \ -$- MUST BE OFF - _ - - PIN:9825.41.1503 c PROPOSED OAS MAIN \ O ^ I OAKWOOD STREET I 135.00' a seNvl (ry I �3.94 AC 55 ucs 55E EXISTING SEWER MAIN ELECTRIC \ \ -------, £ ZONED R-8 D 7 M N A EXISTING OVERHEAD ELECTRIC 10 LOTS r--_- sUNDERGROUNDzLL w uriury 15,817 SF L0T2 I w PROPOSED LL\ rgs[wt[NT 0.3854 AC 6775 SF I O pozpisirc�x 4000 SF IMP .. w �"z 9�\ FFE6810.00' NT ° o - = ss PROPOSED SEWER MAIN/SERVICE Z,U nF t°p 3400 SF MP n 'dNq CRAWL SPACE �EE� �6S x �rcwW„" 9UF O h FFE 691.80' b ^ a �SD�SD� EXISTING STORM PIPE F l o CRAwLspacE ro I 00y ° ° <W�,°� �N(vusuc)M L--------- J + N PROPOSED STORM PIPE \ Z I I �S cz2 a 5g Soa Sm�, LG \ \\ \ EN0 - N88°31' 44"E ° 135.00'----, I O w\Riw '�„� q-qao�HH"9 EX�yo Lora o � ' \ an+ re/w w �� wm°°° 5 PP \ \ / 3 A BT/5 SF 10'UTILITY 0.2014 AC EASEMENT N ~ 5'WIDE CONCRETE SIDE \ c/.\ " 1 o 34005E IMP I a 1 CEDAR COURT - WALK WITH V SHOULDER ` \ S5 m I FFE 881.30' y a EACH SIDE(TYP) \ \ I CRAWL SPACE ^ o\ L--------__ J EX H U U O N88°31' 44"E_ _ PP — - In 0 a \ - - 13---_- R -----O -� NOTE: \ W w\ 775 S o m I ONE DECIDUOUS TLANTED INN.THE 2.5" w NOTE: ,-- 8]]5 SF CALIPER WILL BE PLANTED IN THE ONE DECIDUOUS TREE A MIN.OF 2.5" o 0.2014 AC ml W FRONT YARD OF EACH LOT.(TYP.) \ i 3 CALIPER WILL BE PLANTED IN THE \ 3400 SF IMP FRONT YARD OF EACH LOT. m\ \ sasENSNT FIFE 891.30' O \ w W _ c 2 8"SDR 35 CRAWL SPACE + 3 o h L PVC SS J I I EX 12" __ Wtt NOWOR FORMERLY a n Y w o EX 8" TOLEDO BUILDERS,LLC N88°3f' 44"E W/L - - - I I PIN:9825.41.6325 \ m o _ 135.00' Da/PG 80011108 LL o N ------- - w VACANT NOTE: r-- \'(�-1 3 I 13.73AC OPEN SPACE SHALL BE LEFT UNDISTURBED. n4 \I °j C o O ZONED:R-8(CD) \ `���.:;Y�$$'••�� TREE PROTECTION WILL BE PROVIDED TO /\/�` \ SS C/O s[Tsncz PRESERVE EXISTING VEGETATION. \\ ^ \ (TYP) I I I PROPOSED 10'z 20'CONCRETE S = \ LOT DRIVEWAY ENTRANCE(TYP.) \ _ 2rJ74 11734 SF SEE DETAIL ST-11 \ \ 0.2694 AC I I I 09/18/2023. NOWORFORMERLY \ \ 37W SFIMP + I 13 w �'���� \ ELMWOOD APARTMENTS,LLC. - N \ FFE 890.00 I EX /AMR PIN:9825.31.3312 \ N \ CRAWL SPNawF. O II I pIl ll Da1PG PP APAR \ ee APARTMENTS 5.44 AC k \ \ N - \ I I \ - LOT LINE ZONED:R-8 \ O ��N"i \ // /fI 0�CJ w NOTE: REAR SETBACK NOTE: A O\ \\ OWNER TO MAKE PAYMENT IN LIEU OF SIDEWALK ALONG SOUTH ELEVENTH W z NO CANOPY TREES ARE ALLOWED UNDER _ STREET.PAYMENT MUST BE MADE PRIOR TO CONSTRUCTION DRAWING H EXISTING OVERHEAD UTILITY LINES. C��i\ \\ z� '%PF II W O APPROVAL. F 4 , y0 COMMON O PRIVATE I J O ` \ COMMON OPEN SPACE fII \ \ (REQUIRED=8,000 SF) I 1= 13 BE W EXFH\y\� \ \ (NP) Z w I 10'SIDE SETBACK `? SETBACK Q \ \ \ I I 25'FRONT SETBACK — 10'UTILITY gggggg¢N EX \ "£ PP I I PPIX CITY LIMITS LINE \ \ \ I I TYPICAL LOT CONFIGURATION PER MEBANE GIS _NOTE: �' � 4 NT$ 7 OPEN SPACE SHALL BE LEFT UNDISTURBED DED TO w FI TREE PROTECTION WILL BE PROVIDED PRESERVE EXISTING VEGETATION. O NOT \TP II I k'I END CONCRETEATP SIDEEWALKWALK AT _ PROPERTY CORNER EX z Al PP II EX 62 LF PUBLIC S.S.SEWER PP MAINS TO BE BORED �\ UNDER ROADWAY WITH 16" STEEL ENCASEMENT PIPE EX PP �yO 11 \H W cS Aso U(��M zO�Q w - - - - - - - - - UFti OrL vJ Go PP PROJ GRAPHIC SCALE DRAWING NAME: 20 0 10 20 40 80 22-0151_S.dwg (IN FEET) SHEET NO. Know what's below. 1 inch= 40 ft. Call before you dig. C_4 SUMMIT320 Executive Court, Hillsborough, NC 27278 DESIGN AND ENGINEERING SERVICES Phone // 919.732.3883 Web // www.summitdo.net Cover Letter Project: Montclair Subdivisionepf ofj.nvironl:j Qctober 6, 2023 SDE Project#: 22-0151.010 Information Provided by: William R Wirt, P.E. Contents: Cover Letter, wastewater flow calculations and project narrktiv' P.jyi�ipn,of,1/ater Resources Fast Track Sewer System Extension application and attachments. Project Narrative: Montclair Subdivision consists of 6 single family lots and associated utilities, open space, and sidewalks on 2.04 acres of land.The homes will be two story four-bedroom units. The site is located on S. Eleventh Street and E. Oakwood Street in Mebane, North Carolina and identified with Orange County Parcel PIN #9825-31-5555. The development of this site will require a public sewer extension to connect to the City of Mebane sewer system.The gravity sewer extension will consist of 3 new manholes and 542.51 LF of 8" SDR-35 PVC pipe, 143.34 LF of 8" DIP pipe. The new sewer mains will connect to two existing City of Mebane sewer manholes located on the south side of E. Oakwood Street. Wastewater Flows: 4-bedroom residential homes @ 80 gpd/bedroom 6 homes x 4 bedrooms/home x 80 gpd/bdrm Total Wastewater Flow= 1,920 gpd Items included with this submittal: (one original and one copy) • Cover Letter • Fast Track Form and $600 fee check _ 2 74 • Flow Tracking Form • Site Maps (USGS and Google Street Map) �f1 �1N.����j/4 I �j / /AMR• ` • Flow Reduction Letter ''�"o1111%0\0 1� SUMMIT DESIGN AND ENGINEERING SERVICES OCT 2 6 2023 LETTER OF TRANSMITTAL Raleigh Regional OfFio TO: NCDEQ - Division of Water Sources DATE: 10/24/2023 PRO). NO.: 22-0151 3800 Barrett Drive Raleigh NC 27609 RE: Montclair Subdivision - Fast Track Application ATTN: Jason T. Robinson, P.E. WE ARE SENDING YOU X Prints Reproducible Specifications Other X Copy of Letter Change Order Shop Drawings �X Attached Under Separate Cover Transmitted Via COPIES DRAWING DATE DESCRIPTION 1 N/A 10/19/2023 Fast Track Form & Fee Check 1 N/A Flow Tracking Form (FTSE) TRANSMITTED iX! For Approval As Requested For Your Use For Review and Comment COMMENTS: COPY TO: SIGNATURE: William R. Wirt, P.E. Headquarters Office 320 Executive Court, Hillsborough,NC 27278 919.732.3883 // www.summitde.com �rSU14HIT DESIGN AND ENCINFIRING SERVICES or LETTER OF TRANSMITTAL TO: NCDEQ - Division of Water Sources DATE: 10/06/2023 PRO]. NO.: 22-0151 3800 Barrett Drive Raleigh NC 27609 RE: Montclair Subdivision - Fast Track Application ATTN: Jason T. Robinson, P.E. NC Dept of En'll"Onmental Qualay WE ARE SENDING YOU OCT 10 2023 X Prints Reproducible Raletg"Reg rSpe cations Other X Copy of Letter Change Order i Shop Drawings X Attached Under Separate Cover Transmitted Via COPIES DRAWING -_ DATE j DESCRIPTION j 1 N/A 10/02/2023 Cover Letter 1 N/A 10/02/2023 Fast Track Form & Fee Check 1 N/A 07/07/2023 _� Flow Tracking Form (FTSE) 1 N/A 04/04/2023 _ Site Maps (USGS & Google Street) 1 N/A 3/15/2011 Flow Reduction Request Letter TRANSMITTED X For Approval As Requested For Your Use For Review and Comment COMMENTS: COPY TO: SIGNATURE: William R. Wirt, P.E. Headquarters Office 320 Executive Court, Hillsborough, NC 27278 919.732.3883 // www.summitdc.com From: Mick Parker To: Wild, Elaine Cc: William Wirt.PE;crollins(cbcitvofinebane.com Subject: RE: [External]RE: Montclair Subdivision—Additional Information Request Date: Friday,November 3,2023 9:51:59 AM Attachments: imaae001.ona imaoe002.ono imaoe003.ona imaoe004.ono imaoe005.ona imaoe006.ono imaoe007.ona imaoe008.ona imaoe271895.ona imaoe251462.ono imaae307525.ona imaoe536568.ono imaae942547.ona imaoe313972.ono imaae738430.ona imaoe921838.Dno imaae986493.ona Zoom.odf 1­41 C-4 SITE AND UTILITY PLAN.odf CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Elaine, Please see the attached pdf that is zoomed in for more detail I also attached the site plan for you. Let me know if you need anything else. Thankyou Mick Parker Project Coordinator Tel: 919-732-3883 x3144 From: Wild, Elaine<elaine.wild@deq.nc.gov> Sent:Thursday, November 2, 2023 4:02 PM To: Mick Parker<mick.parker@summitde.com> Cc: William Wirt, PE<william.wirt@summitde.com>; crollins@cityofinebane.com Subject: RE: [External] RE: Montclair Subdivision—Additional Information Request Hi Mick, Thank you for mapping the entire gravity sewer to the force main and the location of the Mebane WWTP. Will you please provide a zoomed in version of the map that shows where the project gravity sewer connects to the two existing manholes that are part of the existing City of Mebane sewer system? Thank you, Elaine Wlld Environmental Engineer Division of Water Resources - Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild(@deq.nc.gov OR Sewer Extension Permitting I NC DEQ subchapter t rules.pdf(state.nc.us) From: Mick Parker<mick.parkerna summitde.com> Sent:Thursday, November 2, 2023 1:59 PM To: Wild, Elaine<elaine.wildCcDdeq.nc.gov> Cc: William Wirt, PE<william.wirt(@summitde.com> Subject: [External] RE: Montclair Subdivision—Additional Information Request CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Elaine, Please see the attached USGS map with City of Mebane's sewer information. Let me know if this will suffice to complete the sewer application. Thank you! Mick Parker Project Coordinator Tel: 919-732-3883 x3144 B❑ From: William Wirt, PE <william.wirt(@summitde.com> Sent:Tuesday, October 31, 2023 2:34 PM To: Mick Parker<mick.parker(@summitde.com> Subject: FW: Montclair Subdivision—Additional Information Request ®❑ William Wirt, PE Project Manager Tel: 919-732-3883 x3151 Cell:757-621-5482 N B❑ From: Wild, Elaine<elaine.wild(@deq.nc.gov> Sent:Tuesday, October 31, 2023 1:36 PM To: crollins(@cit)lofinebane.com; William Wirt, PE <william.wirt(@summitde.com> Subject: Montclair Subdivision—Additional Information Request Hello Chris and William, After reviewing the Fast Track Sewer System Extension Application for Montclair Subdivision, additional information is required in order to further process the application. Please provide the following information by November 30,2023, and note that the requested information must be submitted within 30 days of this request, or the applicant will be required to submit a new application and application fee in accordance with 15A NCAC 02T.0107. 1. The topographical map submitted is not sufficient. According to Section F of the Application Instructions, an 8.5-inch x 11-inch color copy of a USGS Topographic Map should clearly identify the project area, including the closest surface waters, general location of the gravity sewer, pump stations, and force mains, and the downstream connection points for the receiving sewer. Please provide the required map according to the application requirements. 15A NCAC 02T.0107 Staff Review and Permit Preparation states: • "(2) (e) If an application is accepted and later found to be incomplete,the applicant shall be advised how the application or accompanying supporting information may be modified to make it complete. The staff shall advise the applicant: (2) if all required information is not submitted within 30 days, the project will be returned as incomplete. Any resubmittal of a returned application shall be accompanied with a new application fee." Please contact me with any questions that you may have regarding this request. *Please note that the fee for fast track sewer extension permits has increased to$600 as of October 3, 2023[as stipulated in the 2023 House Appropriations Act, House Bill 259, Water Quality and Stormwater Fees,Section 12.14(a)]. Sincerely, Elaine Wlld Environmental Engineer Division of Water Resources - Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild(@deq.nc.gov ®❑ Sewer Extension Permitting I NC DEQ subchapter t rules.pdf(state.nc.us) Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. Links contained in this email have been replaced. If you click on a link in the email above, the link will be analyzed for known threats. If a known threat is found, you will not be able to proceed to the destination. If suspicious content is detected, you will see a warning. F ON:This email originated from outside of the organization. Do not click links or open attachments unless you ize the sender and know the content is safe. Links contained in this email have been replaced. If you click on a link in the email above, the link will be analyzed for known threats. If a known threat is found, you will not be able to proceed to the destination. If suspicious content is detected, you will see a warning. CAUTION:This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe.