Loading...
HomeMy WebLinkAbout240112_Inspection_202312010 Division of Water Resources ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 240112 Facility Status: Active Permit: AWS240112 ❑ Denied Access Inspection Type: Structure Evaluation Inactive Or Closed Date: Reason for Visit: Routine County: Columbus Region: Wilmington Date of Visit: 12/01 /2023 Entry Time: 12:00 pm Exit Time: 12:30 pm Incident #: Farm Name: Donald Strickland Owner Email: Owner: Patricia Ann Strickland Phone: 910-377-2555 Mailing Address: 8005 Clarendon Chadbourn Rd Chadbourn NC 284319427 Physical Address: 8005 Clarendon Chadbourn Rd Chadbourn NC 284319427 Facility Status: ❑ Compliant 0 Not Compliant Integrator: Murphy -Brown LLC Location of Farm: Latitude: 34' 15' 05" Longitude: 78' 50' 41" Travel south from Chadbourn on NC 410 approx. 1.5 miles turn right on Sr 1317, farm is on right approx. 1 miles south of Wards Crossroad Question Areas: Dischrge & Stream Impacts Waste Col, Stor, & Treat Certified Operator: Operator Certification Number: Secondary OIC(s): On -Site Representative(s): Name Title Phone Primary Inspector: Inspector Signature: Secondary Inspector(s): Brian S West Phone: Date: Inspection Summary: Visited site with Mark Siebert, DSW. Farm inactive, no plans to restock. Lagoon berms are overgrown and in need of mwoing. Due to minimal storage available, it is recommended the lagoon level be dropped in accordance with the current nutrient utilization plan. Farm remains in noncompliance due to lack of records available for review Page 1 of 2 Permit: AWS24011 2 Owner: Patricia Ann Strickland Facility Number: 240112 Inspection Date:12/01/23 Inspection TypeStructure Evaluation Reason for Visit:Routine Regulated Operations Swine Design Capacity Current promotions Swine - Feeder to Finish 3,200 I 0 Total Design Capacity: 3,200 Total SSLW: 432,000 Waste Structures Effective Built Closed Designated Observed Type Identifier Date Date Date Freeboard Freeboard Lagoon SWINE 03/21/2005 I D1/31/199E 1 19.50 20.00 Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the ❑ 0 ❑ ❑ State other than from a discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ 0 ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc ❑ 0 ❑ ❑ trees, severe erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a ❑ 0 ❑ ❑ waste management or closure plan? 7. Do any of the structures need maintenance or improvement? 0 ❑ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE ❑ ❑ ❑ to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ ❑ ❑ maintenance or improvement? Page 2 of 2