HomeMy WebLinkAboutSW3230301_O&M Agreement/Plan_20231207SCM element: Potential problem: How to remediate the problem: Erosion or other signs of damage have occurred Repair the damage and improve the flow dissipation at the outlet. structure. The receiving water Discharges from the wet pond are causing erosion Contact the local NCDEQ Regional Office. or sedimentation in the receiving water. WET POND ID 1 Pretreatment other No than forebay? Has Veg. Filter? WET POND ID 2 Pretreatment other No than forebay? Has Veg. Filter? FOREBAY Permanent Pool El. 712.5 Temporary Pool El: 713.5 Clean Out Depth: 3 Sediment Removal El: 709.5 Bottom Elevation: 708.5 FOREBAY Permanent Pool El. 675.5 Temporary Pool El: 677 Clean Out Depth: 3 Sediment Removal El: 672.5 Bottom Elevation: 671.5 ATTACH ADDITIONAL SHEETS IF NECESSARY MAIN POND Permanent Pool El. 712.5 Temporary Pool El: 713.5 Clean Out Depth: 4.5 Sediment Removal El: 708 Bottom Elevation: 707.5 MAIN POND Permanent Pool El. 675.5 Temporary Pool El: 677 Clean Out Depth: 4 Sediment Removal El: 671.5 Bottom Elevation: 671