Loading...
HomeMy WebLinkAboutWQ0001664_Monitoring - 10-2023_20231201Monitoring Report Submittal Permit Number#* WQ0001664 Name of Facility:* Belvedere Plantation Month: * October Year: * 2023 Report Information Type* Upload Document* NDMR, NDAR-1, NDAR-2, NDMLR BPWWTP NDMR 10.2023.pdf 1.35MB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * anthony.futrell@carolinawaterservicenc.com Name of Submitter: * Anthony Futrell Signature: 6;1e'rMarj att�! Date of submittal: 12/1/2023 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* W00001664 Is the monitoring report accepted?* Yes NO Regional Office* Wilmington Reviewer: _anonymous Review Date: 12/4/2023 FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page I of 4 Sampling Person(s) 11 Certified Laboratories Name: Greg Spillman- Name: Enviromental Chemists, Inc. DW # 94 Name: Anthony Futrell Name: Carolina Water Services Inc. - Eastern Region Certificate # 5162 Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? L Compliant Id Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Out of compliance with total nitrogen monthly average. Operations is assessing the issue to determine a solution. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Anthony Futrell Permittee: CWSNC I Certification No.: 1013266 Grade: 4 Phone Number: 312-965-3728 Has the ORC changed since the previous NDMR? - Yes L No 5"L-At— 1i 701aea3 Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. Signing Official: Tony Konsul Signing Official's Title: Director of Operations Phone Number: 704-576-1685 Permit Expiration: 3/31/2026 Digitally signed by Tony Konsul ON: C=US, OU="Director, State Operations", O=Carolina water Service I NC, CN=Tony Konsul, Tony Konsul E-Tony.I ama@rovin thisd cumeenccem Reason: nsapprovingthis document Location: 5821 Fairview Rd, suite 401 Charlotte NC 28209 Date: 2023.1130 11:1 8:1 s-os oo' 11 /3 0/202 Foxy POF Editor version: 1126 Signature Date I certify, under penalty of lave, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel property gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page 0 of y Permit No.: WQ0001664 Facility Name: Belvedere Plantation WWTF County: Pender Month: October Year: 2023 PPI: 001 Flow Measuring Point: _- Influent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: -1 Influent ❑ Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code 0 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00530 00076 O d E QU C O 01 E v O LO O 00 U ° of 2: `9 o LLv 1f- q O G t A :2 N d= az Z a a O O ~'z Q N 3 7; r0 E a O Y N O ta O ~oN a m 'CO aN QO' E Nrn "o O 24-hr hrs GPD mg/L mg/L mg/L #1100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L NTU 1 0 103,057 2 09:09 1 103,057 3 3.3 1 <0.2 0.9 6.44 7.4 7.77 2.04 <2.5 <10 3 09:21 1 136,400 3 4 <1 <0.2 0.9 6.02 6.9 7.65 1.51 <2.5 <10 4 11:29 1 136,400 0.9 7.23 1 <10 5 10:59 1 121,400 3 7.33 <10 6 10:58 0 133,600 1.5 7.4 <10 7 0 177,200 8 0 177,200 9 13:28 0 177,200 1.6 7.22 <10 10 13:30 1 0 131,600 7 5 1 1 <0.2 2.2 1 8.82 11 7.45 1.63 8.4 1 <10 11 12:33 0 111,200 11 8 <1 <0.2 <0.5 9.09 9.1 7.96 0.4 2.6 <10 12 09:52 0 127,400 1.37 7.54 <10 13 10:20 1 127,400 2.2 7.61 <10 14 0 116,700 15 0 116,700 161 08:44 0 116,700 0.39 7.55 <10 17 10:43 1 131,400 <2 2.1 1 <0.2 <0.5 9.8 9.8 7,55 0,75 <2.5 <10 18 14:05 0 113,900 3 6 <1 1.3 2A 6.19 8.7 7.38 0.94 2.7 <10 19 11:23 1 95,700 8 7.12 <10 20 10:39 1 116,400 8.8 7.38 <10 21 0 120,566 221 0 120,566 23 10:03 1 120,566 5 1.5 <1 <0.2 <0.5 10.2 10.2 7.15 0.92 <2.5 <10 24 13:00 0 125,700 0.94 <0.5 4,44 4.44 7.43 <10 25 10:47 1 93,900 6 6.7 <1 <0.2 <0.5 10 10 7.16 0.33 <2.5 <10 26 10:00 0 106,900 0.89 27 10:00 0 105,200 0,03 28 0 117,633 29 0 117,633 30 14:00 0 117,633 1.83 <0.5 10.6 10.6 7.53 31 12:27 1 102,600 4 8.8 <1 <0.2 <0.5 10.9 10.9 7,57 0.6 <2.5 Average: 123,210 4.67 3.49 1.00 0,14 0.58 8.41 9.00 1.01 1.52 0.00 Daily Maximum: 177,200 11,00 8.80 1.00 1.30 2.40 10.90 11,00 7.96 2.04 8.40 10.00 Daily Minimum: 93,900 2.00 0.03 1.00 0,20 0.50 4.44 4.44 7.12 0.33 2.50 10.00 Sampling Type: Recorder Composite Composite Grab Grab Composite Composite Composite Composite Grab Composite Composite Compositel Recorder Monthly Limit: 300,000 10 14 4 10 7 3 15 Daily Limit: 6-9 10 Sample Frequency: Continuous 2 X Week 3 X Year 5 X Week 2 X Week 2 X Week 2 X Week 2 X Week 2 X Week 5 X Week 2 X Week 3 X Year 2 X Week Continuous FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page 3 of 4 Permit No.: W00001664 Facility Name: Belvedere Plantation WWTF County: Pender Month: October Year: 2023 PPI: OQ2 Flow Measuring Point: ❑ Influent ❑ Effluent No flow generated Parameter Monitoring Point: Ll Influent L_. Effluent Groundwater Lowering Surface Water Parameter Code — ► WQ01 > � ❑ R ` v ¢ E F= o c O m E i=� OU v a m 3 a mia•` Ix 0 24-hr hrs Gallons 1 0 0 2 09:09 1 0 3 09:21 1 0 4 11:29 1 0 5 10:59 1 0 6 10:58 0 0 7 0 0 8 0 0 9 13:28 0 0 101 13:30 0 0 111 12:33 0 0 12 09:52 0 0 13 10:20 1 0 14 0 0 15 0 0 16 08:44 0 0 17 10:43 1 0 18 14:05 0 0 19 11:23 1 0 20 10:39 1 0 21 0 0 22 0 0 23 10:03 1 0 24 13:00 0 0 25 10:47 1 0 26 10:00 0 0 27 10:00 0 0 28 0 0 29 0 0 30 14:00 0 0 31 12:27 1 0 Average: 0 Daily Maximum: 0 Daily Minimum: 0 Sampling Type: Estimate Monthly Limit: Daily Limit: FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page 4 of_�L Permit No.: W00001664 Facility Name: Belvedere Plantation WWTF County: Pender Month: October Year: 2023 PPI: 003 Flow Measuring Point: _' influent Fffluent F_ No flow generated Parameter Monitoring Point: ❑ Influent El Effluent E Groundwater Lowering C Surface Water Parameter Code 1, 50050 00940 31616 00610 00620 00400 00665 70300 00600 50060 00680 ti : y E C 0)� ~ N € LL U 'C E ,� N 2 O t _ N N� °° N0 �0 C O F- z N N ad19 L Xc) U_ C C E)m R° O�:Q oc� F- 24-hr hrs GPD mg/L #1100 mL mg/L mg/L su mg/L mg/L mg/L mg/L mg/L 1 0 85,819 2 0 85,819 3 09:40 0.5 85,819 <1 <0.2 0.05 0.07 1 4 12:44 0.5 80,346 5 14:46 0.5 82,563 6 10:47 0 60,276 7.5 7 0 74,644 8 0 74,644 9 13:03 0.5 74,644 10 14:12 0.5 151,924 7.2 11 12:08 0.5 156,359 <1 0.2 <0.02 0.04 <0.5 12 0 149,123 13 11:57 0.51 149,123 14 0 115,944 15 0 115,944 16 13:54 0.5 115,674 17 10:25 0.5 115,674 18 14:25 0 262,777 <1 <0,2 <0.02 7.28 <0.04 0.6 19 09:35 0.5 109,351 20 09:50 0.5 141,271 21 14:39 0 154,964 221 12:50 1 0 154,964 231 12:08 1 0.5 154,964 24 11:10 0 134,209 25 10:20 0.5 135,382 <1 <0.2 <0.02 6.8 0.06 <0.5 26 11:05 0 138,313 27 12:10 0 149,874 28 0 144,619 29 0 144,619 30 14:00 0 144,619 31 12:05 0.5 128,957 <1 <0.2 <0.02 7.57 0.05 0.6 Average: 124,943 1.00 0,04 0.01 0.04 0.44 Daily Maximum: 262,777 1.00 0.20 0.05 7.57 0,07 1.00 Daily Minimum: 60,276 1.00 0.20 0.02 6.80 0.04 1 0.50 Sampling Type: Recorder Grab Grab Grab Grab Grab Grab Grab Monthly Limit: 568,218 250 1.5 10 500 Daily Limit: 6.5-8.5 Sample Frequency: Continuous 3 X Year Weekly Weekly Weekly Weekly Weekly 3 X Year