Loading...
HomeMy WebLinkAboutWM0100558_Monitoring Well Construction Application_20231004FOR OFFICE USE ONLY  PERMIT NO.    ISSUED DATE    NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1.Date: October 4, 2023 2.County:Buncombe 3.What type of well are you applying for? (monitoring or recovery): Monitoring (MW-1, Alternate if needed) 4.Applicant: Janice G. Starnes (Petitioner for DSCA Site #110012) Telephone: 919-707-8361 Applicant’s Mailing Address: DWM DSCA Program, Attn: Mike Cunningham,1646 Mail Service Center, Raleigh, NC 27669-1646 Applicant’s Em ail Add res (if s avai lable): mike.cunningham@deq.nc.gov 5.Contact Person (if different than Applicant): Al Quarles, ATC Associates of North Carolina, P.C. Telephone: 704-529-3200 Contact Person’s Mailing Address: 7606 Whitehall Executive Center Drive, Suite 800, Charlotte NC 28273 Contact Person’s Email Address (if available): William.Quarles@oneatlas.com 6.Property Owner (if different than Applicant): Janice G. Starnes Telephone: 828-674-3587 Property Owner’s Mailing Address: 231 Tipton Hill Road, Leicester, NC 28748 Property Owner’s Email Address (if available): janicestarnes0303@att.net 7.Property Physical Address (Including PIN Number) 740 Haywood Road (PIN: 963814748900000) City Asheville County Buncombe Zip Code 28806 8.Reason for Well(s): Assessment (ex: non-discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: DSCA Program Site (ex: non-discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). DSCA Site ID DC110012 11.Type of contaminants being monitored or recovered:Chlorinated Solvents (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many?No Existing Monitoring or Recovery Well Construction Permit No(s).: 13.Distance from proposed well(s) to nearest known waste or pollution source (in feet): 10 feet 14.Are there any water supply wells located less than 500 feet from the proposed well(s)?None Identified If yes, give distance(s): 15.Well Contractor: John Eisenman, SAEDACCO Certification No.: 4439 Well Contractor Address: 9088 Northfield Drive, Fort Mill, SC 29707 (email c/o: jbyer@saedacco.com) PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse WM0100558 10/6/2023 PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated material: 1 3. Number of wells to be constructed in bedrock: 0 4. Total Number of wells to be constructed: 1 (add answers from 2 and 3) 5. How will the well(s) be secured? Bolt-down 8” manhole, encased in a 2x2 concrete pad. 6. Estimated beginning construction date: 10/30/2023 7. Estimated construction completion date: 11/2/2023 ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of this Well Construction Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C) and accepts full responsibility for compliance with these rules on behalf of DSCA Petitioner for Site DC110012 Agent for Petitioner for DSCA Site DC110012 Signature of Applicant or *Agent Title of Applicant or *Agent Al Quarles * If signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct wells as outlined in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the well(s) conform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). see attached access consent see attached access consent Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources’ Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 GW-22MR Rev. 3-1-2016 Proposed Monitoring Well Power Pole Overhead Utility Source Property DC110012, Mayflower Cleaners, Monitoring Well Locations MW-1 MW-2 MW-3 MW-4 MW-5 Properties requiring well permits 12 Brevard Rd PIN 963814920900000 718 Haywood Rd PIN 963824029000000 (no #) Dundell Ave PIN 963824065300000 Optional for alternative MW-1 location 740 Haywood Rd PIN 963814748900000 Alternate MW-1 750 Hawood Rd PIN 963814644400000 TYPICAL TYPE II MONITORING WELL CONSTRUCTION DETAILS FLUSH GRADE MANHOLE CROSS SECTIONAL VIEW NOT TO SCALE LOCKABLE WELL CAP PROTECTIVE CASING AND CONCRETE PAD L1 CASING MATERIAL steel CASING DIAMETER 8 inches CASING LENGTH 12 inches PAD DIMENSIONS 2 feet x 2 feet HEIGHT ABOVE GROUND flush mounted WELL CASING MATERIAL sch 40 PVC DIAMETER 2 inches JOINT TYPE flush threaded LENGTH 35 feet L2 BACKFILL AROUND CASING MATERIAL cement-sand grout THICKNESS 31 feet SEAL TYPE OF SEAL bentonite L4 THICKNESS 2 feet FILTER PACK TYPE OF FILTER #2 silica sand DISTANCE ABOVE SCREEN 2 feet WELL SCREEN L3 SCREEN MATERIAL Sch 40 PVC DIAMETER 2 inches LENGTH 15 feet SLOT SIZE 0.010 inches DEPTH TO BOTTOM OF MONITORING WELL 50.0 feet DEPTH TO BOTTOM OF BOREHOLE 50.0 feet L1 =0.5 FT. L2 =35 FT.DIAMETER OF BOREHOLE 8.25 inches L3 =15 FT. L4 =50 FT. TITLE Permanent Monitoring Well Diagram FILE PREP. BY REV. BY DATE SITE ID NO. BM 9/19/2023 DC110012 7606 Whitehall Executive Center Drive Charlotte, North Carolina 28273 Mayflower Cleaners 732 Haywood Road Asheville, NC