Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0038377_Vertical Hydraulic Cond_20150902
B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE-MAYO J15-5612-03 6-22-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. ABMW-04 SAMPLE LOCATION: 39.0-41.5' TYPE UNDISTURBED SAMPLE DESCRIPTION: GREY & BROWN FL-MED. SANDY CLAY SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.949 7.490 2.936 7.457 Sample Diameter 2.862 7.269 2.861 7.267 Length/Diameter Ratio 1 1.03 Moisture Content (%) WW= 173.8 DW= 135.6 28.2 WW= 188.8 DW= 144.2 30.9 Sample Wet Weight (grams) 598.8 598.7 Wet Density (cf) 120.2 120.8 Dry Density cf) 93.8 92.3 Saturation (%) TESTED SG= 2.624 99 100 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 81 Reset Date (Y/N) Influent Pressure (psi) 60 Clock Time Elapsed Time HAGUT cm HAIN cm Effluent Pressure (psi) Temp Gradient °C 60 K (cm/sec) B-Value Temp Correction 0.96 K20'C (cm/sec) Y 8-4-15 2:10:15 7.2 1.47 21.0 10 8-4-15 2:24:31 0:14:16 6.5 1.50 21.0 9 6.9E-08 0.976 6.7E-08 8-4-15 2:26:49 0:16:34 6.4 1.51 21.0 9 6.8E-08 0.976 6.7E-08 8-4-15 2:29:11 0:18:56 6.3 1.51 1 21.0 8 6.8E-08 0.976 6.6E-08 8-4-15 2:31:34 0:21:19 6.2 1.52 1 21.0 8 6.8E-08 0.976 6.6E-08 HYDRAULIC CONDUCTIVITY (K20.0 6.6E-08 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE-MAYO J15-5612-03 5-21-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. ABMW-3 SAMPLE LOCATION: 40.0-42.0' TYPE UNDISTURBED SAMPLE DESCRIPTION: BROWN & GREY FI. SANDY CLAY SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.933 7.450 2.923 7.424 Sample Diameter 2.857 7.257 2.842 7.219 Length/Diameter Ratio 1.03 Moisture Content (%) WW= 164.3 DW= 121.5 35.2 WW= 203.6 Dw= 156.0 30.5 Sample Wet Weight (grams) 584.6 578.0 Wet Density (cf) 118.4 118.7 Dry Density cf) 87.6 91.0 Saturation (%) TESTED SG= 2.654 100 99 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) Reset Date (Y/N) 82.8 Influent Pressure (psi) 60 Clock Time Elapsed Time HAGUT (cm HAIN (cm Effluent Pressure (psi) Temp Gradient °C 60 K (cm/sec) B-Value Temp Correction 0.96 K20'C (cm/sec) Y 8-4-15 1:41:34 12.9 1.24 21.0 20 8-4-15 1:54:06 0:12:32 12.4 1.26 21.0 19 2.6E-08 0.976 2.6E-08 8-4-15 1:56:58 0:15:24 12.3 1.27 21.0 19 2.6E-08 0.976 2.5E-08 8-4-15 2:00:18 0:18:44 12.2 1.27 21.0 19 2.5E-08 0.976 2.4E-08 8-4-15 2:03:22 0:21:48 12.1 1.27 21.0 19 2.5E-08 0.976 2.4E-08 HYDRAULIC CONDUCTIVITY (K20.0 2.5E-08 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE - MAYO TESTED BY: JOHN MATHEW J15-5612-03 CHECKED BY: PAUL YARBER 5-21-15 SAMPLE NO. ABMW-3 SAMPLE LOCATION: 3.0-4.9' TYPE REMOLDED SAMPLE DESCRIPTION: GREY SILTY FI: CO. SAND SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 3.000 7.620 2.930 7.442 Sample Diameter 2.850 7.239 2.865 7.277 Length/Diameter Ratio 1.05 Moisture Content (%) WDW- 109.5 16.3 WW- 481.0 DW= 333.7 44.1 Sample Wet Weight (grams) 385.8 481.0 Wet Densityc 76.8 97.0 Dry Density ( cf) 66.1 67.3 Saturation (%) TESTED sCI- 2.674 28 11 80 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT FALLING HEAD TEST Confining Pressure (psi) 72.9 Influent Pressure (psi) 70.2 Effluent Pressure (psi) 70.0 B-Value 0.95 Date Clock Time Elapsed Time seconds Pipet Readings Head Temp °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Initial Final Initial cm Final cm Start End in out in out 8-4-45 3:02:00 3:02:12 12 1.0 23.0 3.0 21.0 40 0092 35.361 21.0 5 7.9E-04 0.976 7.7E-04 8-4-45 3:02:12 3:02:25 13 3.0 21.0 5.0 19.0 35.361 30.629 21.0 5 8.4E-04 0.976 8.2E-04 8-4-45 3:02:25 3:02:41 16 5.0 19.0 7.0 17.0 30.629 25.897 21.0 5 7.9E-04 0.976 7.7E-04 8-4-45 3:02:41 3:03:00 19 7.0 17.0 9.0 15.0 25.897 21.166 21.0 5 8.0E-04 0.976 7.8E-04 Pipet Length, cm 28.390 ------ 24 ------ 0.84541 28.390 ------ 24 ------ 0.8454 -------------- ---- Pipet Volume, cc ------------------ Cross -sectional Area of Pipet, cm2 HYDRAULIC CONDUCTIVITY (K2o.C) 7.9E-04 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE-MAYO J15-5612-03 5-21-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. MW-12 SAMPLE LOCATION: 5.0-6.2' TYPE UNDISTURBED SAMPLE DESCRIPTION: REDDISH BROWN FI. SANDY SILT SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.926 7.432 2.904 7.376 Sample Diameter 2.842 7.219 2.841 7.216 Length/Diameter Ratio 1.03 Moisture Content (%) WW= 135.7 DW- 107.5 26.2 WW= 176.0 Dw= 136.9 28.6 Sample Wet Weight (grams) 592.4 604.2 Wet Density (cf) 121.6 125.0 Dry Density cf) 96.3 97.3 Saturation (%) TESTED SCr- 2.714 94 100 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 65.2 Influent Pressure (psi) 60 Effluent Pressure (psi) 60 B-Value 0.96 Reset (Y/N) Date Clock Time Elapsed Time HAoUT HAIN Temp cm cm °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Y 8-4-15 7:57:39 7.2 1.47 20.5 10 8-4-15 8:01:15 0:03:36 6.5 1.50 20.5 9 2.7E-07 0.988 2.7E-07 8-4-15 8:01:50 0:04:11 6.4 1.51 20.5 9 2.7E-07 0.988 2.7E-07 8-4-15 8:02:29 0:04:50 6.3 1.51 20.5 9 2.7E-07 0.988 2.6E-07 8-4-15 8:03:08 0:05:29 6.2 1.52 20.5 8 2.6E-07 0.988 2.6E-07 HYDRAULIC CONDUCTIVITY (K20.0 2.7E-07 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE-MAYO J15-5612-03 5-21-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. MW-12 SAMPLE LOCATION: 50.0-52.35' TYPE UNDISTURBED SAMPLE DESCRIPTION: LIGHT GREY FI. SANDY SILT SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sam le Length 2.968 7.539 2.924 7.427 Sample Diameter 2.880 7.315 2.865 7.277 Length/Diameter Ratio 1.03 ff Moisture Content (°/o) WW= 1s2.1 DW- 138.2 31.8 WW= 136.5 DW- 101.5 34.5 Sample Wet Weight (grams) 558.6 573.9 Wet Density cf) 110.1 116.0 Dry Density ( cf) 83.5 86.2 Saturation (%) �= so= 2.684 85 11 98 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT FALLING HEAD TEST Confining Pressure (psi) 91.2 Influent Pressure (psi) 7 Effluent Pressure (psi) 60.0 B-Value 0.95 Date Clock Time Elapsed Time seconds Pipet Readings Head Temp °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Initial Final Initial cm Final cm Start End in out in out 8-4-45 2:30:00 2:31:48 108 1.0 23.0 2.0 22.0 40.092 37.726 21.0 5 4.3E-05 0.976 4.1E-05 8-4-45 2:31:48 2:33:42 114 2.0 22.0 3.0 21.0 37.726 35.361 21.0 5 4.3E-05 0.976 4.2E-05 8-4-45 2:33:42 2:35:45 123 3.0 21.0 4.0 20.0 35.361 32.995 21.0 5 4.2E-05 0.976 4.1E-05 8-4-45 2:35:45 2:37:56 131 5.0 19.0 32.995 30.629 21.0 5 4.3E-05 0.976 4.2E-05 Pipet Length, cm ------------------ Pipet Volume,cc t0.0 .390 24----- -- .8454 Cross-sectional Area ofPipet, cm2 HYDRAULIC CONDUCTIVITY (K20-C) 4.2E-05 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE-MAYO J15-5612-03 5-21-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. MW-13 SAMPLE LOCATION: 2.5-4.75' TYPE UNDISTURBED SAMPLE DESCRIPTION: GREY & BROWN FI. SANDY SILT SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.933 7.450 2.933 7.450 Sample Diameter 2.861 7.267 2.861 7.267 Length/Diameter Ratio 1 1.03 Moisture Content (%) WW= 148.3 DW= 115.9 28.0 WW= 223.7 DW= 174.0 28.6 Sample Wet Weight (grams) 606.4 610.7 Wet Density (cf) 122.5 123.4 Dry Density cfj 1 95.7 96.0 Saturation (%) TESTED SG= 2.654 100 100 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 64 Influent Pressure (psi) 60 Effluent Pressure (psi) 60 B-Value 0.96 Reset (Y/N) Date Clock Time Elapsed Time HAoUT HAIN Temp (cm (cm °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Y 8-4-15 11:16:16 7.2 1.47 20.5 10 8-4-15 11:18:37 0:02:21 5.5 1.54 20.5 7 1.1E-06 0.988 1.1E-06 8-4-15 11:18:48 0:02:32 5.4 1.55 20.5 7 1.1E-06 0.988 1.1E-06 8-4-15 11:19:00 0:02:44 5.3 1.55 20.5 7 1.1E-06 0.988 1.1E-06 8-4-15 11:19:12 0:02:56 5.2 1.56 20.5 6 1 1.1E-06 0.988 1.1E-06 HYDRAULIC CONDUCTIVITY (K20.0 1.IE-06 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE-MAYO J15-5612-03 5-21-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. MW-16 SAMPLE LOCATION: 5.0-6.75' TYPE UNDISTURBED SAMPLE DESCRIPTION: GREY SILTY FL - CO. SAND SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.955 7.506 2.912 7.396 Sample Diameter 2.862 7.269 2.860 7.264 Length/Diameter Ratio 1.03 Moisture Content (%) WW= 194.9 Dw= 170.7 14.2 WW= 220.6 Dw= 192.3 14.7 Sample Wet Weight (grams) 646.3 658.6 Wet Density (cf) 129.5 134.1 Dry Density cf) 113.4 116.9 Saturation (%) TESTED SG= 2.664 81 93 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 63.4 Influent Pressure (psi) 60 Effluent Pressure (psi) 60 B-Value 0.96 Reset (Y/N) Date Clock Time Elapsed Time HAGUT HAIN Temp (cm cm °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Y 8-4-15 11:39:48 4.4 1.59 21.0 5 8-4-15 11:40:08 0:00:20 3.5 1.63 21.0 4 8.7E-06 0.976 8.5E-06 8-4-15 11:40:24 0:00:36 3.0 1.65 21.0 3 8.7E-06 0.976 8.5E-06 8-4-15 11:40:48 0:01:00 2.5 1.67 21.0 1 2 1 8.7E-06 0.976 8.5E-06 8-4-15 11:41:03 0:01:15 2.3 1.68 21.0 1 1 1 8.6E-06 0.976 8.4E-06 HYDRAULIC CONDUCTIVITY (K20.0 8.5E-06 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE-MAYO J15-5612-03 5-21-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. SB-1 SAMPLE LOCATION: 4.0-5.5' TYPE UNDISTURBED SAMPLE DESCRIPTION: LIGHT BROWN FL SANDY CLAY SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.922 7.422 2.948 7.488 Sample Diameter 2.839 7.211 2.850 7.239 Length/Diameter Ratio 1.03 Moisture Content (%) ww= 153.6 Dw= 122.2 25.7 ww= 149.1 Dw= 113.4 31.5 Sample Wet Weight (grams) 556.7 581.5 Wet Density (cf) 114.7 117.8 Dry Density cf) 91.2 89.6 Saturation (%) TESTED so= 2.634 84 99 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 64.4 Influent Pressure (psi) 60 Effluent Pressure (psi) 60 B-Value 0.96 Reset (Y/N) Date Clock Time Elapsed Time HAoUT HAIN Temp (cm cm °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Y 8-4-15 7:30:26 4.3 1.59 21.0 5 8-4-15 7:32:54 0:02:28 3.5 1.63 21.0 3 1.1E-06 0.976 1.1E-06 8-4-15 7:33:15 0:02:49 3.4 1.63 21.0 3 1.1E-06 0.976 1.1E-06 8-4-15 7:33:39 0:03:13 3.3 1.63 21.0 3 1.1E-06 0.976 1.1E-06 8-4-15 7:34:07 0:03:41 3.2 1.64 21.0 3 1 1.1E-06 0.976 1.1E-06 HYDRAULIC CONDUCTIVITY (K20.0 1.IE-06 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE-MAYO J15-5612-03 5-21-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. SB-7 SAMPLE LOCATION: 0.3-2.8' TYPE UNDISTURBED SAMPLE DESCRIPTION: BROWN SILTY FL-MED. SAND SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.930 7.442 2.916 7.407 Sample Diameter 2.809 7.135 2.812 7.142 Length/Diameter Ratio 1.04 Moisture Content (%) WW= 132.7 DW= 113.9 16.5 WW= 158.9 DW= 134.4 18.2 Sample Wet Weight (grams) 625.5 633.0 Wet Density (cf) 131.2 133.2 Dry Density cf) 112.6 112.6 Saturation (%) TESTED SG-- 2.674 92 100 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 62.6 Influent Pressure (psi) 60 Effluent Pressure (psi) 60 B-Value 0.96 Reset (Y/N) Date Clock Time Elapsed Time HAoUT HAIN Temp (cm cm °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Y 8-4-15 1:14:16 4.3 1.59 21.0 5 8-4-15 1:14:31 0:00:15 3.5 1.63 21.0 4 1.1E-05 0.976 1.1E-05 8-4-15 1:14:45 0:00:29 3.0 1.65 21.0 3 1.1E-05 0.976 1.0E-05 8-4-15 1:15:03 0:00:47 2.5 1.67 21.0 1 2 1 1.1E-05 0.976 1.1E-05 8-4-15 1:15:19 0:01:03 2.3 1.68 21.0 1 1 1 1.0E-05 0.976 1.0E-05 HYDRAULIC CONDUCTIVITY (K20.0 1.0E-05 cm/sec