Loading...
HomeMy WebLinkAboutNC0070289_Compliance Evaluation Inspection_20231127United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO070289 I11 121 23/10/24 I17 18I � I 19 I s I 201 I 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701� I 711 LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 02:OOPM 23/10/24 20/04/01 Ridgewood Farms at Stones Throw WWTP Olde Creek Trl Exit Time/Date Permit Expiration Date Concord NC 28025 03:48PM 23/10/24 23/11/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Braden Joshua Cook/ORC/704-788-4164/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Verlene Hoffecker,PO Box 690725 Charlotte NC 282277013//704-607-3506/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Roberto Scheller DWR/MRO WQ/707-235-2204/ ag l 93FA4keviewer for Agency/Office/Phone and Fax Numbers Date Signature of M�J-4" Brandy Co H P WR/MRO WQ/704-235-2185/ 10/27/2023 F161F969A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO070289 I11 12I 23/10/24 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The current NPDES Permit # NC0070289 was issued on April 1, 2020, and expires on November 30, 2023. A renewal application was received by the Division on June 5, 2023. The subject WWTP is permitted as a 0.0500 MGD, Grade II, biological wastewater treatment facility. Review period, September 2022 througe August 2023, was reviewed for compliance with permit limits. During the 12-month review period the following violations were reported: 05-2023 Coliform Fecal (Limit) 400/100 ml (Reported) 600/100 ml Daily Maximum Exceeded NOV issued 04-2023 NH3 as N (Limit) 5 mg/I (Reported) 12.55 mg/I Monthly Average Exceeded NOV issued 05-2023 NH3 as N (Limit) 25 mg/I (Reported) 29 mg.1 Daily Maximum Exceeded NOV issued 05-2023 NH3 as N (Limit) 5 mg/I (Reported) 19.82 mg/I Monthly Average Exceeded NOV issued *A letter for Unpaid Civil Penalty Assessments was issued from the Raliegh Office dated February 23, 2022, for unpaid civil penalties LV-2021-0232 for $365.76 and LV-2021-0196 for $215.76. A second letter was issued on July 6, 2023, for unpaid civil penalties LV-2022-0094 for $615.76. *Annual Reports have not been submitted to this Office as required by House Bill 1160 and the Clean Water Act. *In accordance with Part I, Section A.(3) of NPDES Permit NC0070289, the permittee shall perform an Engineering Assessment on the structural intergrity of the wastewater treatment plant no later than October 31, 2020. As of the date of this inspection no report has been submitted to the Mooresville Regional Office. * Two large trees have been girdled (debarked) and are standing dead creating a hazard to operations of the WWTP. Trees should be removed. Due to the above noted violations (*) this inspection is being issued as a Notice of Violation of permit conditions. At the time of inspection WWTP appeared to be well operated, records well kept, up to date, and readily available for review. Effluent was clear with few visible suspended solids. Page# Permit: NCO070289 Owner -Facility: Ridgewood Farms at Stones Throw WWT Inspection Date: 10/24/2023 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ■ ❑ ❑ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ■ ❑ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ■ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ■ ❑ ❑ Comment: Copy of Annual Report has not been sent to Mooresville Regional Office. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? ■ ❑ ❑ ❑ Page# 3 Permit: NCO070289 Owner -Facility: Ridgewood Farms at Stones Throw WWT Inspection Date: 10/24/2023 Inspection Type: Compliance Evaluation Pump Station - Influent Yes No NA NE Is the wet well free of excessive grease? ❑ ❑ 0 ❑ Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ Are float controls operable? 0 ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ ❑ 0 ❑ Is audible and visual alarm available and operational? 0 ❑ ❑ ❑ Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ❑ Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? ■ ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? ■ ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ ■ ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ 0 ❑ ❑ Page# 4 Permit: NCO070289 Owner -Facility: Ridgewood Farms at Stones Throw WWT Inspection Date: 10/24/2023 Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? ■ ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? ❑ 0 ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable (low turbulence)? ❑ ❑ 0 ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) ❑ ❑ ❑ ❑ Comment: Blockage of skimmer WWTP just put back in operation. Pumps-RAS-WAS Yes No NA NE Are pumps in place? 0 ❑ ❑ ❑ Are pumps operational? ■ ❑ ❑ ❑ Are there adequate spare parts and supplies on site? ❑ ❑ ■ ❑ Comment: RAS-WAS are air lift pumps. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? 0 ❑ ❑ ❑ Comment: De -chlorination Yes No NA NE Page# 5 Permit: NCO070289 Inspection Date: 10/24/2023 De -chlorination Owner -Facility: Ridgewood Farms at Stones Throw WWT Inspection Type: Compliance Evaluation Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: At time of inspection sampler was 4 degrees Celsius. Yes No NA NE Tablet ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ 2 Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 6