Loading...
HomeMy WebLinkAboutWM0401492_Application_20231127 AECOM AECOM Technical Services of North Carolina, Inc. (704)522-0330 tel 6000 Fairview Road,Suite 200 Charlotte,NC 28210 October 26, 2023 Mr. Jim Gonsiewski Winston-Salem Regional Office Division of Water Resources Water Quality Regional Operations Section Re: Monitoring Well Permit Applications MW-17M,MW-17R,MW-19M,and MW-19D Colonial Pipeline Company-Lexington Booster Station 667 Helmstetler Road,Lexington,Davidson County,NC NCDEQ Incident Number: 95267 Dear Mr. Gonsiewski: On behalf of Colonial Pipeline Company,AECOM Technical Services of North Carolina, Inc. (AECOM) has prepared the attached permit application in accordance with 15A NCAC 2C .0105. This well permit application is for the construction of 4 monitoring wells (MW-17M, MW-17R, MW-19M, and MW-19D) in association with NCDEQ Incident Number 95267, the Colonial Pipeline Company Lexington Booster Station(site)located at 667 Helmstetler Road,Lexington,Davidson County,North Carolina. The proposed temporary and permanent groundwater monitoring well locations are to be located on the following properties: • MW-17M and MW-17R: Colonial Pipeline Company, 685 Helmstetler Road,Lexington,NC 27295 PIN 6705-03-41-5191,Parcel ID 180250000095 • MW-19M and MW-19D: Colonial Pipeline Company,Helmstetler Road, Lexington,NC 27295 PIN 6705-04-50-2422,Parcel ID 1802500000098 Included herein are the Applications for Permit to Construct a Monitoring or Recovery Well System packets for each of the aforementioned properties. Each packet includes Form GW-22MR, a map of the proposed well locations, and general well construction diagrams. Upon approval, please forward the monitoring well construction permit(s) to me at jeff.hvozdikkaecom.com. If you have any questions or require additional information, please do not hesitate to call me at 412-977-4074. Sincerely, AECOM TECHNICAL SERVICES OF NORTH CAROLINA,INC. Jeffrey T. Hvozdik,PG Project Manager NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY-DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7,Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. FOR OFFICE USE ONLY 1. Date: 26 October 2023 2. County: Davidson PERMIT NO. ISSUED DATE 3. What type of well are you applying for?(monitoring or recovery): Monitoring 4. Applicant: Colonial Pipeline Company Telephone: 336-669-7903 Applicant's Mailing Address: 1000 Lake Street,Alpharetta, GA 30009 Applicant's Email Address(if available): dreedv(a)colpipe.com 5. Contact Person(if different than Applicant): Jeff Hvozdik(AECOM) Telephone: 412-977-4074 Contact Person's Mailing Address: 6000 Fairview Road,Suite 200, Charlotte, NC 28210 Contact Person's Email Address(if available): ieff.hvozdik(a-)-aecom.com 6. Property Owner(if different than Applicant): Colonial Pipeline Company Telephone: Property Owner's Mailing Address: 1185 Sanctuary Pkwy, P.O. Box 1624,Alpharetta,GA 30009-1624 Property Owner's Email Address(if available): 7. Property Physical Address(Including PIN Number) 685 Helmstetler Road(PIN 6705-03-41-5191) City Lexington County Davidson Zip Code 27295 8. Reason for Well(s): Assessment,groundwater contamination (ex: non-discharge permit requirements,suspected contamination,assessment,groundwater contamination,remediation,etc.) 9. Type of facility or site for which the well(s)is(are)needed: Pipeline booster station (ex: non-discharge facility,waste disposal site, landfill, UST,etc.) % Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). NCDEQ Incident Number 95267 11. Type of contaminants being monitored or recovered: Petroleum (ex: organics, nutrients, heavy metals,etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes,how many? 52(total wells) Existing Monitoring or Recovery Well Construction Permit No(s).: WM0400963,WM0400885,WM0401041,WM0401042,WM0401043 WM0401241,WM041242,WM0401243,WM0401244,WM0401245,WM0401250,WM0401251 13. Distance from proposed well(s)to nearest known waste or pollution source(in feet): Approximately 400 ft 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? 2 If yes,give distance(s): One—200 feet SW(WSW-07),one—360 feet SE(WSW-06),WSW-21 (abandoned) 15. Well Contractor: Geologic Exploration Certification No.: Varies by individual driller Well Contractor Address: 176 Commerce Boulevard,Statesville, NC 28625 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C.0105(f)(7),attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons C. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated 5. How will the well(s)be secured? Locking cap material: 1 3. Number of wells to be constructed in bedrock: 1 6. Estimated beginning construction date: December 2023 4. Total Number of wells to be constructed: 1 7. Estimated construction completion date:December 2023 (add answers from 2 and 3) ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C.0105(f)(5),attach a scaled map of the site showing the locations of the following: a. All property boundaries,at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections,streams,or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use,within 500 feet of the proposed well or well system. C. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination(such as septic tank systems,pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills,or other waste disposal areas)within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s)will be constructed in accordance with approved specifications and conditions of this Well Construction Permit as regulated under the Well Construction Standards(Title 15A of the North Carolina Administrative Code, Subchapter 2C)and accepts full responsibility for compliance with these rules Signatur6 of Applicant or*Agent Title of Ap ca or Agent *If signing as Agent, attach authorization agreement stating Printed naPne of Appli ant or*Agent that you have the authority to act as the Agent. If the property is owned by someone other than the applicant,the property owner hereby consents to allow the applicant to construct wells as outlined in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the well(s)conform to the Well Construction Standards(Title 15A of the North Carolina Administrative Code,Subchapter 2C). Signature of Property Owner(if different than Applicant) Printed name of Property Owner(if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources'Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Raleigh Regional Office Swannanoa, NC 28778 3800 Barrett Drive Wilmington Regional Office Phone: (828)296-4500 Raleigh, NC 27609 127 Cardinal Drive Extension Fax: (828)299-7043 Phone: (919)791-4200 Wilmington, NC 28405 Fax: (919)571-4718 Phone: (910)796-7215 Fayetteville Regional Office Fax: (910)350-2004 225 Green Street,Suite 714 Washington Regional Office Fayetteville, NC 28301-5094 943 Washington Square Mall Winston-Salem Regional Office Phone: (910)433-3300 Washington, NC 27889 450 W.Hanes Mill Road Fax: (910)486-0707 Phone: (252)946-6481 Suite 300 Fax: (252)975-3716 Winston-Salem_, NC 27105 Mooresville Regional Office - 6-9800 610 East Center Avenue W'" I° 797 Mooresville, NC 28115 ft al gh l� Phone: (704)663-1699 A Fax: (704)663-6040 t �.. oor le F yeftariIle r r- Will ngron t GW-22MR Rev.3-1-2016 I I I =�/ r I I _ I /� \ N LEGEND wsw-os ! II— Release Point I I —i I — — — _ _ O i 0 Proposed Deep Monitoring Well Location A Proposed Intermediate Monitoring Well Location ® Proposed Shallow Monitoring Well Location 0 Deep Monitoring Well Location _ _ _ L Wswoe A Intermediate Monitoring Well Location I — _ —I �_• _�/ / \ \ \ \ / • Shallow Monitoring Well Location O Water Supply Well- In Use WSW-23 Q0 Water Supply Well-Not In Use I — _ — — — _ ® Water Supply Well-Abandoned I — — — _ I I I I 1 L I J_ Approximate Location of Pipeline -- Parcel Lines Roadway Centerlines Major Hydrography ' yWSW-4 Minor Hydrography CS W o ewsw ' rF — I Approximate area of known NC 2L Standard ' SW � —47--T Exceedance(Dec. 2022) / _ o SW-02 ' 4 I W® 6 _ MW-20D7 / _ Notes: Site features based on"Site Plan"from Apex CAD No. WSW-22 MW_3 CPC18000.003, 1/30/18 \ I / MZ • MW-29 I W30 Pipeline location based on images provided by Colonial > / o / _ MW-30"C-30M O Pipeline Company on 8/1/19 / / WS®17 / • W®-01 \ / Parcel lines and centerlines obtained from Davidson MW 4 25 /�� / r MW-36D ��� MW 4 W-5D • County Information Technology/GIS (http://www2.co.da- _ •� 7 M MW_21M / vidson.nc.us/GIS/Web GISDownloads.aspx)on 2/7/19 — — _ MW:1 Aerial photography obtained from NC OneMap(http://da- e ` r T _ M;19 WSW-20® MW-26 I _ ta.nconemap.gov/geoportal/catalog/raster/down load.page) LMw\D`�I \ a) on 2/18/19 I 1 _— MW-28• MW-,5 ` / Major hydrography and other hydrography obtained from 1 w® 9 1 % ` / /\ \ MW-,SDI City of Lexington (https://Iexington.connectgis.com/- !' WW-21 /-' e / \ MW-23D Map.aspx)on 2/14/19 \ '0 •MW-18 WSW-06 L �_ / i+ e / \ MW-°MI - M _ W-17 \ / r- / OMW-31M MW-31.OMW-31D ` C 1 / / WS0-07 I ®w3w_1-6A MW-35D[J �� / MW-17R ®wsw-1613 ` Q I MW-35M/ <DAMW-17M I ~MW U) ` \ 1 1 I/ .�\iMW-16D 1 Q I / W-33D Mw_ /\ �\ Q MW-33M� MW32W-32D 'Y , MW-32M , MW-34D - e\ / /\ a \\ z 4. 57< wsw.,, ~°0M a�wpcv O WSW-,z� Z J l J �Z CD a��V0 0 400 O Z�W �——— 1 J--JOl1J WSW-13® \ / / I APPROX.SCALE,ft. 0 W LU O Q / / / UJ2d� Shallow Monitoring Well 2' X 2' CONCRETE PAD Diagram GROUND SURFACE MAN HOLE COVER OR STICK UP LOCKING WELL CAP 6" PVC OUTER CASING Approximately 21' 2" DIAMETER SCH 40 PVC RISER A. a , NEAT CEMENT OR CONCRETE—GROUT 0 J 0 2t BENTONITE WELL SEAL un 2' J W Q _ X - O Q _ No. 2 SILICA SAND FILTER PACK 20' _ 2" DIAMETER SCH 40 PVC 0.010" MACHINE SLOT SCREEN NOTE: DRAWING NOT TO SCALE Issue Status: PROPOSED Colonial Pipeline Company PROPOSED SHALLOW MONITORING WELL CONSTRUCTION DIAGRAM AMOM 667 HELMSTETLER ROAD LEXINGTON, NORTH CAROLINA Intermediate Monitoring Well 2' X 2' CONCRETE PAD Diagram GROUND SURFACE MAN HOLE COVER OR STICK UP LOCKING WELL CAP Approximately 56' ~6" PVC OUTER CASING 2" DIAMETER SCH 40 PVC RISER q NEAT CEMENT OR CONCRETE—GROUT 0 J 0 2' BENTONITE WELL SEAL 0 2' J W Q _ X - O d Q _ No. 2 SILICA SAND FILTER PACK 10' _ 2" DIAMETER SCH 40 PVC 0.010" MACHINE SLOT SCREEN NOTE: DRAWING NOT TO SCALE Issue Status: PROPOSED Colonial Pipeline Company PROPOSED INTERMEDIATE MONITORING WELL CONSTRUCTION DIAGRAM AMOM 667 HELMSTETLER ROAD LEXINGTON, NORTH CAROLINA NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY-DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. FOR OFFICE USE ONLY 1. Date: 26 October 2023 2. County: Davidson PERMIT NO. ISSUED DATE 3. What type of well are you applying for?(monitoring or recovery): Monitoring 4. Applicant: Colonial Pipeline Company Telephone: 336-669-7903 Applicant's Mailing Address: 1000 Lake Street,Alpharetta,GA 30009 Applicant's Email Address(if available): dreedy(cDcolpipe.com 5. Contact Person(if different than Applicant): Jeff Hvozdik(AECOM) Telephone: 412-977-4074 Contact Person's Mailing Address: 6000 Fairview Road,Suite 200, Charlotte, NC 28210 Contact Person's Email Address(if available): Ieff.hvozdikC�_)aecom.com 6. Property Owner(if different than Applicant): Colonial Pipeline Company Telephone: Property Owner's Mailing Address: 1185 Sanctuary Pkwy, P.O. Box 1624,Alpharetta,GA 30009-1624 Property Owner's Email Address(if available): 7. Property Physical Address(Including PIN Number) Helmstetler Road(PIN 6705-04-50-2422) City Lexington County Davidson Zip Code 27295 8. Reason for Well(s): Assessment,groundwater contamination (ex: non-discharge permit requirements,suspected contamination,assessment,groundwater contamination, remediation,etc.) 9. Type of facility or site for which the well(s)is(are)needed: Pipeline booster station (ex: non-discharge facility,waste disposal site, landfill, UST,etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). NCDEQ Incident Number 95267 11. Type of contaminants being monitored or recovered: Petroleum (ex: organics, nutrients, heavy metals,etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes,how many? 52(total wells) Existing Monitoring or Recovery Well Construction Permit No(s).: WM0400963,WM0400885,WM0401041,WM0401042,WM0401043, WM0401241,WM041242,WM0401243,WM0401244,WM0401245,WM0401250,WM0401251 13. Distance from proposed well(s)to nearest known waste or pollution source(in feet): Approximately 400 ft 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? 1 If yes,give distance(s): One—380 feet SE(WSW-06),WSW-20 and WSW-21 abandoned 15. Well Contractor: Geologic Exploration Certification No.: Varies by individual driller Well Contractor Address: 176 Commerce Boulevard,Statesville, NC 28625 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7),attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons C. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated 5. How will the well(s)be secured? Locking cap material: 1 3. Number of wells to be constructed in bedrock: 1 6. Estimated beginning construction date: December 2023 4. Total Number of wells to be constructed: 1 7. Estimated construction completion date:December 2023 (add answers from 2 and 3) ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C.0105(f)(5),attach a scaled map of the site showing the locations of the following: a. All property boundaries,at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections,streams,or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use,within 500 feet of the proposed well or well system. C. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination(such as septic tank systems, pesticide, chemical or fuel storage areas,animal feedlots as defined in G.S. 143-215.1013(5), landfills,or other waste disposal areas)within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s)will be constructed in accordance with approved specifications and conditions of this Well Construction Permit as regulated under the Well Construction Standards(Title 15A of the North Carolina Administrative Code, Subchapter 2C)and accepts full responsibility for compliance with these rules Signfatur of Applicant r*Agent Title of Ap lica t or Agent I`A(e, If signing as Agent,attach authorization agreement stating Printed hame of A plicant or*Agent that you have the authority to act as the Agent. If the property is owned by someone other than the applicant,the property owner hereby consents to allow the applicant to construct wells as outlined in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the well(s)conform to the Well Construction Standards(Title 15A of the North Carolina Administrative Code, Subchapter 2C). Signature of Property Owner(if different than Applicant) Printed name of Property Owner(if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources'Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Raleigh Regional Office Swannanoa, NC 28778 3800 Barrett Drive Wilmington Regional Office Phone: (828)296-4500 Raleigh, NC 27609 127 Cardinal Drive Extension Fax: (828)299-7043 Phone: (919)791-4200 Wilmington, NC 28405 Fax: (919)571-4718 Phone: (910)796-7215 Fayetteville Regional Office Fax: (910)350-2004 225 Green Street,Suite 714 Washington Regional Office Fayetteville, NC 28301-5094 943 Washington Square Mall Winston-Salem Regional Office Phone: (910)433-3300 Washington, NC 27889 450 W. Hanes Mill Road Fax: (910)486-0707 Phone: (252)946-6481 Suite 300 Fax: (252)975-3716 Winston-Salem_, NC 27105 Mooresville Regional Office Win Sale 6-9800 610 East Center Avenue 797 Mooresville, NC 28115 ✓L al Phone: (704)663-1699 Fax: (704)663-6040 ✓ p ' (e r le F eM rMe t vJ Will ngton r GW-22MR Rev.3-1-2016 LEGEND I I I WSW-o® Release Point I --i 0 Proposed Deep Monitoring Well Location A Proposed Intermediate Monitoring Well Location ® Proposed Shallow Monitoring Well Location 0 Deep Monitoring Well Location 0 Intermediate Monitoring Well LocationWSW-.. �A Shallow Monitoring Well Location O Water Supply Well- In Use I f—w.,W-23 I \ \ Q0 Water Supply Well-Not In Use ® Water Supply Well-Abandoned J_ Approximate Location of Pipeline r — r -- Parcel Lines Roadway Centerlines Major Hydrography ' _ yWSW-4 Minor Hydrography o eWSW Approximate area of known NC 2L Standard ' I LWSWW-4 — �— Exceedance(Dec. 2022) / _ oSW-02 ' 14 � I w® e 1 _,~ _ Notes: Site features based on"Site Plan°from Apex CAD No. \\ / I / /, - MW_3 M / I WSW-22 CPC18000.003, 1/30/18 / MW- • \ I / MW-29 - I W-30 Pipeline location based on images provided by Colonial > o MW-30"e.W-30M l / Pipeline Company on 8/1/19 / / WS-17 / / • ® \ / /��. �/ O Parcel lines and centerlines obtained from Davidson MW-36D.— _ o / MW 4 W MW 4 Mw25 i WSW-o1 I \ / \` t 7 County Information Technology/GIS (http://www2.co.da- _ _ _ 5D MW_21M \/ / C� vidson.nc.us/GIS/Web_GISDownloads.aspx)on 2/7/19 — _ ._ MW 11 MW iM ^ / / `\� I J Aerial photography obtained from NC OneMap(http://da- e ` r M* MW-19D WSW-20ED MW-26 ta.nconemap.gov/geoportal/catalog/raster/down load.page) _ _ � y MW-iSDD on 2/18/19 _ _ I L MW-19M Mw-26* / g W-15 Major hydrography and other hydrography obtained from 1 W®SW 9 1 % /e \ MW-,5D — —y City of Lexington (https://Iexington.connectgis.com/- !' WW-21 — / I L-23D Map.aspx)on 2/14/19 MW 18 • WSW-06AW ® 17 / \ \W EMI fl\ / ! MW-17 OMW-31M \/MW-31.OMW-31D O / 1 W9OW-07 /\ ®WSW-,-6n )))�--- MW-35D[i a ®WSW-166 I w ` Q / MW-35M CL 1 '_ /a MW-16D O _MW-33DMW- \ ' A MW-33M M 32a � Y ,MW-32M { MW-34D / �\ - 1 1 /1 �MW-34M / \ �.� I tJ Lam\ / /4. \\ / �v / x co WSW.,, / / \ / I I N J o C)M / A o WSW-12*- Z J \ � l J �Zo a�W 0 400 OZU)w� 1 ` \ / J-�0lil WSW-130 A APPROX.SCALE,ft. O W w W Q / / UJ77n Intermediate Monitoring Well 2' X 2' CONCRETE PAD Diagram GROUND SURFACE MAN HOLE COVER OR STICK UP LOCKING WELL CAP Approximately 56' ~6" PVC OUTER CASING 2" DIAMETER SCH 40 PVC RISER q NEAT CEMENT OR CONCRETE—GROUT 0 J 0 2' BENTONITE WELL SEAL 0 2' J W Q _ X - O d Q _ No. 2 SILICA SAND FILTER PACK 10' _ 2" DIAMETER SCH 40 PVC 0.010" MACHINE SLOT SCREEN NOTE: DRAWING NOT TO SCALE Issue Status: PROPOSED Colonial Pipeline Company PROPOSED INTERMEDIATE MONITORING WELL CONSTRUCTION DIAGRAM AMOM 667 HELMSTETLER ROAD LEXINGTON, NORTH CAROLINA Deep Monitoring Well 2' X 2' CONCRETE PAD Diagram GROUND SURFACE MAN HOLE COVER OR STICK UP LOCKING WELL CAP Approximately 75' 6" PVC OUTER CASING 4 2" DIAMETER SCH 40 PVC RISER CONCRETE-GROUT NEAT CEMENT OR CONCRETE-GROUT 0 Q Approximately 16' 0 2' BENTONITE WELL SEAL 0 0 2, w - Q X - O CL d - Q _ No. 2 SILICA SAND FILTER PACK 5' _ 2" DIAMETER SCH 40 PVC 0.010" MACHINE SLOT SCREEN NOTE: DRAWING NOT TO SCALE Issue Status: PROPOSED Colonial Pipeline Company PROPOSED DEEP MONITORING WELL CONSTRUCTION DIAGRAM AMOM 667 HELMSTETLER ROAD LEXINGTON, NORTH CAROLINA