Loading...
HomeMy WebLinkAboutNC0038377_Table 6-10 Vertical Hydraulic Conductivity of Undisturbed Soil_20150902TABLE 6-10 VERTICAL HYDRAULIC CONDUCTIVITY OF UNDISTURBED SOIL SAMPLES MAYO STEAM ELECTRIC PLANT DUKE ENERGY PROGRESS, LLC, ROXBORO, NC Depth Hydraulic Sample ID (feet BGS) Conductivity Sediment Type Comment (cm/sec) From To Gray and brown fine Residual saprolitic ABMW-02 39.0 41.5 6.6 x 10-8 to medium sandy schist directly below clay ash $ Brown and gray fine Residual soil directly ABMW-03 40.0 42.0 2.5 x 10 sandy clay below ash ABMW-03 3.0 4.9 a 7.9 x 10 Gray silty fine to Representative bottom coarse sand ash Reddish brown fine Background MW-12 5.0 6.2 2.7 x 10' sandy silt soil/saprolite upgradient of plant Light gray fine sandy Background saprolite/ MW-12 50.0 52.35 5 4.2 x 10 representative silt upgradient regolith Gray and brown fine Residual soil MW-13 2.5 4.75 6 1.1 x 10 sandy silt upgradient-west of ash basin Gray silty fine to Downgradient alluvium MW-16 5.0 6.65 6 8.5 x 10 coarse sand in MW-16S screened interval s Light brown fine Residual soil/saprolite SB-1 4.0 5.5 1.1 x 10 sandy clay NW of ash basin Brown silty fine to Representative soil/fill SB-7 0.3 2.8 5 1.0 X 10 medium sand near toe of ash basin dam Notes: BGS = below ground surface cm/sec = centimeter per second Prepared by: RBI Checked by: EMB Revised by: EMB Rechecked by: JAW Water level measurements used for these calculations were collected on June 17, 2015. P:\Duke Energy Progress.1026\105. Mayo Ash Basin GW Assessment Plan\1.11 CSA Reporting\Tables\Report Tables\Table 6-10 Vertical Hydraulic Conductivity of Undisturbed Soil Page 1 of 1