HomeMy WebLinkAbout20231291 Ver 1_More Info Received_20231018Hydraflow Storm Sewers Extension for AutoCAD® Civil 3D® 2009 Plan Project File: Ditch Piping.stm Number of lines: 5 1 Date: 03-22-2023 Hydraflow Storm Sewers Extension v6.066 Storm Sewer Tabulation Page Station Len Drng Area Rnoff Area x C Tc Rain Total Cap Vel Pipe Invert Elev HGL Elev Grnd / Rim Elev Line ID coeff (1) flow full Line To Incr Total Incr Total Inlet Syst Size Slope Dn Up Dn Up Dn Up Line (ft) (ac) (ac) (C) (min) (min) (in/hr) (cfs) (cfs) (ft/s) (in) (%) (ft) (ft) (ft) (ft) (ft) (ft) 1 End 90.000 0.00 4.14 0.00 0.00 3.73 0.0 7.2 6.3 23.58 34.58 6.99 30 0.71 23.25 23.89 24.87 25.51 0.00 32.00 2 1 00.000 0.00 4.14 0.00 0.00 3.73 0.0 6.1 6.7 24.93 34.68 7.28 30 0.72 23.89 25.32 25.51 26.99 32.00 32.00 3 2 96.000 0.00 4.14 0.00 0.00 3.73 0.0 5.5 6.9 25.67 34.77 7.31 30 0.72 25.32 26.01 26.99 27.70 32.00 32.00 4 3 94.000 3.46 3.46 0.90 3.11 3.11 5.0 5.0 7.1 22.10 34.62 6.52 30 0.71 26.01 26.68 27.70 28.25 32.00 32.00 5 3 90.000 0.68 0.68 0.90 0.61 0.61 5.0 5.0 7.1 4.34 5.57 3.54 15 0.74 26.01 26.68 27.70 28.11 32.00 32.00 Project File: Ditch Piping.stm Number of lines: 5 Run Date: 03-22-2023 NOTES: Intensity = 22.84 / (Inlet time + 4.00) A 0.53; Return period = 10 Yrs. ; c = cir e = ellip b = box HydraFlow Storm Sewers Extension v6.066 Storm Sewer Profile Proj. file: Ditch Piping.stm Elev. (ft) 40.00 36.00 32.00 28.00 24.00 20.00 0 N M ��1■����Ion 1���� ��1■� -��1■__-�� �� 111 ..lid ��1■���� � .�TT.1EIscTi�c?�dt1��- --1_■-�lli111G[I��i 1 ----- 50 HGL 40.00 36.00 32.00 28.00 24.00 20.00 100 150 200 250 300 350 400 450 500 Reach (ft) Hydraflow Storm Sewers Extension Storm Sewer Profile Proj. file: Ditch Piping.stm Elev. (ft) 40.00 36.00 32.00 28.00 24.00 20.00 0 N M L17 �w.�..111<cn�nZiIIIY�■------��- ---------- ---------- ---------- ---------- 40.00 36.00 32.00 28.00 24.00 74% 20.00 50 100 150 200 250 300 350 400 450 500 HGL Reach (ft) Hydraflow Storm Sewers Extension From: Jesse M Degnan. PWS To: Beecher. Gary H CIV USARMY CESAW (USA) Cc: Snider. Hollev Subject: [External] RE: Corps PCN and Permit applications comments for the Hampstead Station Expansion in Pender County, NC (SAW-2023-01011) Date: Wednesday, October 18, 2023 2:56:25 PM Attachments: imaae001.pno imaae002.pno imaae003.ong imaae004.ona Piped Ditch Calc.odf Headwaters Fig 2 Storm Sewer Drainage Area Mao.odf C2 - Site Grading Drainage and Drainage Plan rev 2023-07-27.odf CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Gary —The information from the engineer that is referenced below is attached. Please let us know if you have any additional questions. Thank you, -Jesse JESSE M DEGNAN, PWS I Environmental Project Manager ECS SOUTHEAST, LLP I T 704.525.5152 C 704.339.9002 JDegnan@ecslimited.com I www.ecslimited.com Confidential/proprietary message/attachments. Delete message/attachments if not intended recipient. From: Jesse M Degnan, PWS <JDegnan@ecslimited.com> Sent: Wednesday, October 18, 2023 1:25 PM To: Beecher, Gary H CIV USARMY CESAW (USA) <Gary.H.Beecher@usace.army.mil> Cc: Snider, Holley <holley.snider@deq.nc.gov> Subject: RE: Corps PCN and Permit applications comments for the Hampstead Station Expansion in Pender County, INC (SAW-2023-01011) Gary— Please see my responses in red below. I've reached out to the engineer on this project and have requested they provide the pipe size and any calculations they may have run to ensure water will not backup on the neighboring property. Just let me know if you need any additional information. Thank you, -Jesse JESSE M DEGNAN, PWS I Environmental Project Manager ECS SOUTHEAST, LLP I T 704.525.5152 C 704,339,9002 JDegnan(@ecslimited.com I www.ecslimited.com Confidential/proprietary message/attachments. Delete message/attachments if not intended recipient. From: Beecher, Gary H CIV USARMY CESAW (USA) <Gary.H.Beecher(causace.army.mil> Sent: Tuesday, October 17, 2023 10:59 AM To: Jesse M Degnan, PWS <J Deana n (a)ecsl i m ited.com> Cc: Snider, Holley <holley.snider(cDdeq.nc.gov> Subject: [EXTERNAL] Corps PCN and Permit applications comments for the Hampstead Station Expansion in Pender County, NC (SAW-2023 01011) Jesse, Please see my PCN Permit Application comments below for the Hampstead Station Expansion project in Pender County, NC. USACE Project ID; SAW-2023-01011 Application Review Comments: -Mitigation Requirement-: Wetland impacts over .10 -acres will require mitigation. (c) Compensatory mitigation at a minimum one -for -one ratio will be required for all wetland losses that exceed 1/10-acre and require pre - construction notification. (page 8 of the NWP 39 guidance Document) I use a standard 2:1 ratio for permanent wetland impacts (regardless of quality). We're aware of the mitigation requirements and I believe have provided the appropriate documentation indicating that. But let me know if additional information is needed. Attached is the Statement of Availability provided by the WLS Turtle Creek Mitigation Bank, which was included in the PCN, indicating expressed interest to utilize 0.30 Riparian Wetland Mitigation Credits. I've attached photos depicting representative site and feature conditions. At some point in the past, the site was cleared and graded. Wetland Area #1 and the northern fork of Wetland Area #2 are manmade ditches that capture/convey stormwater. Wetland Area 1 is only present due to the development of the property located immediately north of the subject property. Per the County's request to provide means for ingress/egress between the subject property and the property located immediately north of the subject property, Wetland Impacts A, B and C at Wetland Area #1 are unavoidable. Proposed Wetland Impacts A & C are necessary and are proposed to be filled and graded for road construction. A pipe is depicted at the eastern -most County -required road crossings of Wetland Area 1, which is labeled Wetland Impact B. Based on existing site conditions, if there is a means of reducing the mitigation ratio below a 2:1 ratio, I know our Client would be very appreciative. -How does filling of these wetlands affect upstream areas - This wetland/stream system takes water/hydrology from property above it (see lidar map) Will filling these aquatic features not effect the property above this one? Based on the small size of the drainage area up reach from the subject property, no. The Corps will not issue a permit if we know that the fill may back up water on a neighbor above the project. Wetland Area #1 does not extend further west, and Wetland Impacts A & C (circled below) represent the western limits of Wetland Area #1. Therefore, fill proposed at the locations of Wetland Impacts A & C will not influence hydrology on the neighboring property. The full extent of Stream 1 and Wetland Area 2 (including the northern fork) are proposed to be piped, thus, allowing water from the property to the west to continue being conveyed east. An existing crossing of the Wetland 2/Stream 1 complex is present onsite and does not appear to have any negative influence on the movement of water deriving from the property to the west. The proposed pipe will be sized appropriately and installed to accommodate safe passage of aquatic life. WETLANDS WETLAND IMPACT SAND FILTER LEVEL SPREADER VEGETATED FILTER -51--- Ex. CONTOUR - 51 POND CONTOUR RIP -RAP OUTLET PROTECTION STORM INLET STORM PIPE ® STORM MANHOLE } r' -Plans- There is a vey minimal one page plan attached to the PCN. Will the stream and wetlands both be filled? I don't know which areas will be filled and which will be left. Please send in a more detailed plan that accurately shows which aquatic features will be filled. Everything depicted as blue in the Impacts Exhibit is proposed to be filled and/or piped. The "LOT 2 WETLANDS MAP" more clearly depicts the stream vs. wetland areas. I've also attached the site layout and grading/sediment and erosion control plans. If still needed, I will work with the client on generating a revised impacts drawing that more clearly depicts the impacts. Just let me know. Is the stream going to be piped? There's what looks like a 24" storm pipe going through the stream? The full extent of Stream 1 depicted in the attached "LOT 2 WETLANDS MAP" will be piped. There is an existing 24" pipe that measures 41 linear feet. The 41 linear feet should have been accounted for as temporary impact in the PCN for disturbance associated with replacing that portion of pipe, but it wasn't, and I apologize. The revised proposed stream impact totals should, therefore, be 41 linear feet of temporary impact and 284 linear feet of permanent impact. -N LF B- I've requested in IPAC to be a member of this project, you may have already gotten a message from the IPAC system. There are only a handful of mature trees on the property, none of which have cavities, sloughing bark, or deeply furrowed bark. Representative site photos are attached. This application is not complete due to the inadequate plan and lack of mitigation proposal. The Corps may send additional comments for this application. Thank you for your assistance with this project. Respectfully, Gary US Army Carps of Engineers Wi�'Nnpton ASttkf Gary Beecher USACE Wilmington Field Office Regulatory Project Manager Office (910) 251-4694 Cell (910) 473-7045 gary.h.beecherPusace.army.mil REVISIONS @vt830 C3O 7T77 I U II-a I - -� NV ICI II II II � .. I II E c< I AR A AR A T 50 II OIP S �ga7�1 L 178.391 lU'JtI CHIK N = 226,436.3767 f �" 9� 07 E = 2,388,436.8850 Ff , - S 66007'10" E oIP 25.0�2�EI -S 66°OZ111 E►I 1 66007 Jl S 66°07'1=E� �25_7 01 I \ r ti�0 - 28 = If�// 3, �- I I - _ _ 3�3 00 \\� 313.6 \ 33.68 3.07 CI-11- 33. 7 #4 \9= _ 12000 SF RETAIL I \32.65 36426gyp ENDWALL 3 mv. 26.68 6-0�7.71152334° 33.688 \ 4 0 32.98 - .98 �3 9.4� 48 1 33.48- 33.85 i 29 -� \2d ENDWAL / RED \INV. 26 CI-9 INV. 25.3 1-8 / r�, " �� =�- =30= i \ \\ ,/ 8 V. 26.01 h // 1 20'x3O' �ET 3,4.0 UJ 32.1 32.5 3.65_ to M \ I i -� / 33.15 0 W � i ��� � FI ER /'y 20' CONC. L READER L •32.98 32.50 / I 95 ,?33.48 103LF-15" RC 33.00 EA 33.45 32.98 �P OUTtET- 2.-bu 28LF-15" RCPI 33.48 // \ / I PROTECT ER 10 D l \ e p / 32 66 32.66 j` 32.70 / 37 M I 60LF-10" PVC ® 0.50% 0 31.00 0 I PON9 �BY-PASS 31.5PP STRUCTURE _-CI -15 3 OVEFLOW STRUCTURE 31.50 / / \ 32.00 _ / / \ 5 - � \ / TOP EL. 29. 3STORMWATER 2 _ �� 2.00" ORIFICE EL 27.00 32.20EMERGPOND #2 32.70 CRESTEN`3ZPOILOLWAY M CI-1 FES-3 / 32.60 33.10 Co JJ / 32.50 MCRFTF 32.90 33.40 .75 3 CII14 32.90 CI-1 2.25 / 33.40 3 .00 33.70 33.20 `�� � CP / \ I 3.50 33 0 a , 33.70 32.00 / S 48o N .70 " a 33.20 CI-12 32 \ ? 3 S414S� "�/ I M� 4 33.90 33.70 33.20 3 .20 / 00' ry n 33.70 3 .70 /\ \ d 33.70 #3 / \ Cp 0 / .90 / 33.90 12000 SF RETAIL 33.90 33 l 32.65 SI S 40o 3.40 32.15 1=24 F FVM3Gl�AIMgRK. \�33.20 5°15,4 1 \ \r3 Z28���c° ° ° 32.90 \ 33.70 \ 33.20 NAVp 88 3g \\ \ 26 \ 33. 3 33.70 / \ \ \ � � � 33.43 33.55 33. 33.90 \ \ \ \ \ FIP 3 34.05 32\ \\ 32.45 33.62 3d / 32.95 CI-28 3Z \ \ 32.45 / \ \ \ \ \ p\ 32.95 32.000 _ \ \ \ \ \ \ \\\\\50LA - Cl- 7 w \ S 480 \ \ �\ \ I- - -� Sg 212�'� F \ \ \\ \\\\\ \32.00 \ 1. 32.50 \ \\\ 32.90 3 .25 ` 3 40 CI- \ 2°50 3: \3 00 3: ,1(91 z' ti 00 33.,' \ 9 \ C Oo NO WATER SERVICE VISIBLE ALONG HEADWATER DRIVE Engineering, PLLC SITE BENCHMARK: EX. MAG NAIL ELEV. 30.33' NAVD '88 DESIGN & MAINTENANCE OF ALTERNATIVE LAND USES H a m p s t e a d RSC ENGINEERING, PLLC 15226 US HWY 17 HAMPSTEAD, NORTH CAROLINA 28443 PHONE: 910.270.9599 FAX: 910.270.9592 E-Mail: sonya@rscengineering.com Station EMERGENCY SPILLWAY CREST EL. 29.50 INV. 22.78' I/ I \ N 66007'10" W POND #1 BY-PASS 175.12' STRUCTURE 3LF-10" PVC @ 0.500% 20'x30' VEGETATED FILTER -,,---50' VEGETATED SETBACK 20' CONC. LEVEL SPREADER RAND FILTER R"- AP OUTLET PROTECTION #1 TOP OF BANK 15" RCP REINFORCED TURF GRID I OUTLET PROTECTION STOP OF BANK LL #5 INV. 23.25 " RCP �50' VEGETATED SETBACK _RETAINING WALL TOP EL. 29.00 32.55 33.20 I 33.70 33.20 I 0 33.70 e a / I 33.90 33.90 I 32.05 I 33.25 CI-3 I 33.75 32.55 I 2800 REST.) I #1 \ 4 I 00 SF RETAIL 33.25 I 33.75 I 33.20 I 33 0 _ I M N"'FPSI I 00 GYM) 2.05 I ` 32.55 M C - M / 33.90 d 33.25 33.75 33.20 / 33.70 AL K / I - I / 33.90 32.05 / I 32.55 CI-20 / 33.5 / I r•) 33.775 33. 0 \ / 33. 3.25 I 335. 55 I / �0 0 33.25 33.75 33.20 33.7 / c1-22 Expansion Project DEVELOPED BY The JayTees Properties IV, LLC 105 Island Drive Wrightsville Beach, INC 28480 I OIR OUTLET PROTECTION I Cr_'CI,IPI WETLANDS SAND FILTER / LEVEL SPREADER / VEGETATED FILTER EX. CONTOUR 51 PROPOSED CONTOUR RIP -RAP OUTLET PR❑TECTI❑N 58.72 PROPOSED GRADE 58.22 O STORM INLET ® STORM MANHOLE OUTLET # PIPE SIZE Q10 V DMAX CLASS THICKNESS La A W Endwall #2 36" 5 3.7 6" A 9" 12' 9' 15' FES-1 24" 10.07 4.4 6" A 9" 8' 6' 10' FES-2 15" 1.97 3.2 6" A 9" 5' 3.75' 6.25' FES-3 30" 17.37 5.5 12" B 18" 15' 7.5' 17.5' #1 and #2 1 10" 1 1.99 4.2 1 6" 1 A 9" 3.3' 1 2.5' 1 4.17' STORMDRAIN DATA PIPE# INLET #UP RIM ELEVUP (ft) INVERTUP (ft) PIPELENGTH PIPESIZE (in) PIPE TYPE PIPE SLOPE INVERTDN (ft) INLET#DN (ft) (%) 1 CI-1 32.00 27.12 67 24 CLASS III RCP 0.40 26.85 FES-1 2 CI-2 32.05 28.25 108 15 CLASS III RCP 0.30 27.93 CI-1 3 CI-3 32.05 28.56 103 15 CLASS III RCP 0.30 28.25 CI-2 4 CI-4 32.05 28.91 118 15 CLASS III RCP 0.30 28.56 CI-3 5 CI-5 32.00 28.19 64 15 CLASS III RCP 0.41 27.93 CI-1 6 CI-6 32.30 28.03 25 18 CLASS III RCP 0.41 27.93 CI-1 7 CI-7 32.30 28.38 23 15 CLASS III RCP 0.41 28.28 CI-6 8 CI-8 32.00 28.77 97 15 CLASS III RCP 0.41 28.38 CI-7 9 CI-9 32.00 28.85 19 15 CLASS III RCP 0.41 28.77 CI-8 10 CI-10 32.00 27.89 38 15 CLASS III RCP 0.50 27.70 FES-2 11 CI-11 32.00 28.01 23 15 CLASS III RCP 0.52 27.89 CI-10 12 CI-12 32.00 26.22 43 30 CLASS III RCP 0.51 26.00 FES-3 13 CI-13 32.00 28.40 186 15 CLASS III RCP 0.50 27.47 CI-12 14 CI-14 32.00 28.76 90 15 CLASS III RCP 0.40 28.40 CI-13 15 CI-15 31.00 28.68 78 15 CLASS III RCP 0.35 28.41 CI-13 16 CI-16 32.00 26.69 29 24 CLASS III RCP 0.31 26.60 CI-12 17 CI-17 32.00 26.77 23 24 CLASS III RCP 0.35 26.69 CI-16 18 CI-18 32.00 26.82 13 18 CLASS III RCP 0.38 26.77 CI-17 19 SDMH-19 33.00 26.93 33 15 CLASS III RCP 0.33 26.82 CI-18 20 CI-20 32.05 27.47 155 15 CLASS III RCP 0.35 26.93 SDMH-19 21 CI-21 32.05 27.79 91 15 CLASS III RCP 0.35 27.47 CI-20 22 CI-22 31.50 28.19 121 15 CLASS III RCP 0.33 27.79 CI-21 23 CI-23 32.00 27.07 74 24 CLASS III RCP 0.41 26.77 CI-17 24 CI-24 32.15 28.10 69 15 CLASS III RCP 0.41 27.82 CI-23 25 CI-25 32.00 28.04 114 18 CLASS III RCP 0.41 27.57 CI-23 26 CI-26 31.75 28.37 21 15 CLASS III RCP 0.38 28.29 CI-25 27 CI-27 1 31.75 28.47 23 15 CLASS III RCP 0.43 28.37 CI-26 28 CI-28 32.00 29.02 235 15 CLASS III RCP 0.41 28.47 CI-27 29 CI-29 31.50 28.58 72 15 CLASS III RCP 0.40 28.29 CI-25 KInTCC 1. THE DEVELOPER INTENDS TO OBTAIN PERMIT FROM ACOE TO PIPE THE STREAM SO THAT NO SETBACKS WILL BE REQUIRED SITE GRADING AND DRAINAGE DATE: 4/5/2023 SCALE: 1" = 50' JOB # 22054020 DRAWN BY: JAR SHEET C2 REVISIONS � r 'mU V777T7 7 \ 7 -4 ti , 77U a =- AR A v QA4 4 I � ,I OIP S V / V 71 iu' �t Fa eUK N = 226,436.3767 E = 2,388,436.8850 S 66007'1 " E oIP 25.02'EI / _-S-f�6°n7 J 1=" E I S 66°07'E_ -_12 . \ III If� - -29- /^M / 29620.8 r uo \\� 3 6 r' 33.68 1117.74 off/ / \\ ; �' 3.07 CI-5 N1 1- / #4 /I 29 - � 12II0 SF RET CRos �o I � / 32.65 REPR I / �p ENDWALL �� J 33.15 VV. 26.68 33.68 33.b ■ / 32.98 2.98 32.98 33.35 � . �3.48- 933<48--� 33.4 85 8 � - ; / � \ \ 150717.E � � c 9 _� �� ENDWAL CI-9 \ ,IN26 �0�� � INV. 25.32 /l M N "i �3 ���% INV. 26.01 CIS-816076 / I 32.00 \�%5 /O y \ 1 ' == \ 20'x30' VFGETAT� _ s 33.75 0 32.50 33.+S- �/ / II %% \ \ 20' CONC\. LFI L 9 �33.48 103LF-15" RCP 33.0 / J )%/� \ READER 33.E 32.98 /( Rf1R�P OUTLET-�1° 28LF-15" RCP 30-8 2 PROTECTION #2 33. \' I 1 `\1 I \ SAN� L° 32.6E ° 33.10 _ 33.16 33.16 r , I '� I / 3 M I 60LF-10 PVC ® 0.50%Li / \ I POND. -,BY-PASS Ch /PP _ �� I STRUCTURE Z 732.00 --7- OVEFLOW STRUCTURE 32.50 `3 / I TOP EL. 29.8E STORMWATER / 4 S \\�5� \\ I 1.50" ORIFICE EL 27. 32.60 P9ND #2 ' 4g°S4 4� �� 0 1-13 Z \ \ 32. FES-3 / �i1\R4a 33.10 32.00 f 32.50 "tum" ere R cu 32.90 10658.89733.40 2.25 CII14 3.20 32.9C -1 Cp / 3 .00 3.70 33.20 33.40 3 50 OU 33.L 4 ° d 33.70 10711.98�32 / S 4$° 3C\J 33.70 ° 33.20 CI-12J \ S4'4S„ _ / I 4 33.90 � 33.20 / \ 23\00\ � 8964.436 j 33.70 33 0 40 ° / \ � Ch / 3.20 \ \ d '~/ 33.70 / Cp RETAIL 33.90 / 32.90 33.90 _ \ S ° 433 0 4 32.65 1 4 l SIT O 14434.158 32.15 ' Fk. AGNCyMgR � � S \ \73S 908� . 3 . EL � N K: \ -S S°151 F 32.90 \ Nq�� 3s.3gI \ 4S E �� \ 33.40 32.93 33.20 33.70 404 13 / \ \ \ $8 \ 264 42� \ ` 33.43 33.70 33.90 5 33.12 3 5 \ EIP 32� 32'J •� 33.62 a 32 3 95 \� CI-28 32.45 \ \ 32.95 Cl-CI-7 041 \\ \, Q0 \ S 4$oM \\\\\\ \\ �t410.78 1-25 _ \ \ SIR 2ZZ� \ \ \\\\\ \ \ `\32.00 \ 1. 32.50 \ \ \\\ \ 32.90 3 .25 CI-26 \\\ 3�0 2.50 33 00 *41 3321\50 �.� 3 2 7 \ N. �sF tip' \� NO WATER SERVICE VISIBLE \ �\\4���.�1. \\ ALONG HEADWATER DRIVE Engineering, PLLC SITE BENCHMARK: EX. MAG NAIL ELEV. 30.33' NAVD '88 DESIGN & MAINTENANCE OF ALTERNATIVE LAND USES H a m p s t e a d RSC ENGINEERING, PLLC 15226 US HWY 17 HAMPSTEAD, NORTH CAROLINA 28443 PHONE: 910.270.9599 FAX: 910.270.9592 E-Mail: sonya@rscengineering.com CREST EL. 29.50 POND #1 BY-PASS STRUCTURE 3LF-10" PVC ® 0.50% 20'x30' VEGETATED 20' CONC. LEVEL �SREADER S� F-F�TER rP OUTLET ION P#1 L&_15" RCP RIP' RAP -OUTLET =15LF-15" [CP QJM 1 oSANITARY SEWER PUMP STATION I ' I I X I \ I \ CI-3 I I I I I I I I PS 3 I / I I/ y / I I / I I / I N 66007'10" W 175.12' STORMDRAIN DATA I CIR PIPE# INLET#UP RIM ELEVUP INVERTUP PIPELENGTH PIPESIZE PIPE TYPE PIPE SLOPE INVERTDN INLET #DN (ft) (ft) (ft) (in) (%) (ft) 1 CI-1 32.00 27.12 67.000 24 CLASS III RCP 0.40 26.85 FES-1 2 CI-2 32.05 28.25 108.000 15 CLASS III RCP 0.30 27.93 CI-1 3 CI-3 32.05 28.56 103.000 15 CLASS III RCP 0.30 28.25 CI-2 4 CI-4 32.05 28.91 118.000 15 CLASS III RCP 0.30 28.56 CI-3 5 CI-5 32.00 28.19 64.000 15 CLASS III RCP 0.41 27.93 CI-4 6 CI-6 32.30 28.03 25.000 18 CLASS III RCP 0.41 27.93 CI-5 7 CI-7 32.30 28.38 23.000 15 CLASS III RCP 0.41 28.28 CI-6 8 CI-8 32.00 28.77 97.000 15 CLASS III RCP 0.41 28.38 CI-7 9 CI-9 32.00 28.85 19.000 15 CLASS III RCP 0.41 28.77 CI-8 10 CI-10 32.00 27.89 38.000 15 CLASS III RCP 0.50 27.70 CI-9 11 CI-11 32.00 28.01 23.000 15 CLASS III RCP 0.52 27.89 CI-10 12 CI-12 32.00 26.22 43.000 30 CLASS III RCP 0.51 26.00 FES-2 13 CI-13 32.00 28.40 186.000 15 CLASS III RCP 0.50 27.47 CI-12 14 CI-14 32.00 28.76 90.000 15 CLASS III RCP 0.40 28.40 CI-13 15 CI-15 32.00 28.68 55.000 15 CLASS III RCP 0.49 28.41 CI-13 16 CI-16 32.00 26.69 29.000 24 CLASS III RCP 0.31 26.60 CI-12 17 CI-17 32.00 26.77 23.000 24 CLASS III RCP 0.35 26.69 CI-16 18 CI-18 32.00 26.82 13.000 18 CLASS III RCP 0.38 26.77 CI-17 19 SDMH-19 33.00 26.93 33.000 15 CLASS III RCP 0.33 26.82 CI-18 20 CI-20 32.05 27.47 155.000 15 CLASS III RCP 0.35 26.93 SDMH-19 21 CI-21 32.05 27.79 91.000 15 CLASS III RCP 0.35 27.47 CI-20 22 CI-22 31.50 28.19 121.000 15 CLASS III RCP 0.33 27.79 CI-21 23 CI-23 32.00 27.07 74.000 24 CLASS III RCP 0.41 26.77 CI-17 24 CI-24 32.15 28.10 69.000 15 CLASS III RCP 0.41 27.82 CI-23 25 CI-25 32.00 28.04 114.000 18 CLASS III RCP 0.41 27.57 CI-23 26 CI-26 31.75 28.37 21.000 15 CLASS III RCP 0.38 28.29 CI-25 27 CI-27 31.75 28.47 23.000 15 CLASS III RCP 0.43 28.37 CI-26 28 CI-28 32.00 29.02 135.000 15 CLASS III RCP 0.41 28.47 CI-27 29 CI-29 31.50 28.58 72.000 15 CLASS III RCP 0.40 28.29 CI-25 J 11. I I \ 53. 0 / .00,i.010 53. i dow, / �/ �i / vim I � ,. . I � �� i 55 3CI_ 1 / 8314.231 N, d / I ) )_�f (V 0` o / 33.25 33.75 3.20 3 3.7 CI-22 / Station Expansion DEVELOPED BY The JayTees Properties IV, LLC 105 Island Drive Wrightsville Beach, NC 28480 Project STORM SEWER DRAINAGE AREA MAP DATE: 4/5/2023 SCALE: 1" = 50' JOB # 22054020 DRAWN BY: JAR SHEET FIG 2