Loading...
HomeMy WebLinkAboutNC0003433_Cape Fear-WSP-TOPO-1_20150902i■.. .-I.omit, ...-Alit. _.iili31 I, DAVID K. BRUBAKER, CERTIFY THAT THIS PROJECT WAS COMPLETED UNDER MY DIRECT AND RESPONSIBLE CHARGE FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION; THAT THIS AIRBORNE SURVEY WAS PERFORMED AT THE 95 PERCENT CONFIDENCE LEVEL TO MEET FEDERAL GEOGRAPHIC DATA COMMITTEE STANDARDS; THAT THIS SURVEY WAS PERFORMED TO MEET THE REQUIREMENTS FOR A TOPOGRAPHIC/PLAN I METRIC SURVEY TO THE ACCURACY OF CLASS A AND VERTICAL ACCURACY WHEN APPLICABLE TO THE CLASS C STANDARD, AND THAT THE ORIGINAL DATA WAS OBTAINED ON APRIL 17, 2014; THAT THE SURVEY WAS COMPLETED ON JULY 2, 2015; THAT CONTOURS SHOWN AS BROKEN LINES MAY NOT MEET THE STATED STANDARD; AND ALL COORDINATES ARE BASED ON NAD83/2011 AND ALL ELEVATIONS ARE BASED ON NAVD88. DAVID K. BRUBAKER, P.L.S. # 2968 DATE 1�BARSIASLOF BEARINGS: NC GRID NAD83/2011. 2. ELEVATIONS ARE BASED ON NAVD88. 3. THIS MAP IS NOT A BOUNDARY SURVEY, PROPERTY LINES SHOWN HEREON PER CHATHAM AND LEE COUNTY GIS AND ARE FOR REFERENCE ONLY. 4. THE PLANIMETRIC LOCATION ON THIS MAP IS BASED ON PHOTOGRAMMETRIC MAPPING OF IMAGERY COLLECTED ON APRIL 17, 2014. [ALTITUDE OF SENSOR = 3,600' / SENSOR FOCAL LENGTH = 153.558mm] THE IMAGERY CAPTURED IS SUITABLE TO CREATE 1 "=100' SCALE MAPPING AND CONTOURS AT AN INTERVAL OF 2', AND MEETS THE NATIONAL MAP ACCURACY STANDARDS FOR 1 "=100' SCALE MAPPING. DATA PROVIDED WHERE CLEAR AND VISIBLE ON THE IMAGERY IS WITHIN 2' OF ITS TRUE POSITION. a NO UNDER11 O 011 Ul nEs HAVE a WMIM at WMW I = 7Hs PACT. THE LOCATION OF ANY AND ALL UTILITIES SHOWN HEREON WHETHER PUBLIC OR PRIVATE, IS BASED ON PHOTOGRAMMETRIC MAPPING AND IS APPROXIMATE ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. WSP CANNOT ASSUME RESPONSIBILITY FOR MISIDENTIFICATION OR OMISSION OF UNDERGROUND UTILITIES. 6. DASHED CONTOURS AND ESTIMATED SPOT ELEVATIONS SHOWN IN OBSCURED AREAS ARE COMPILED FROM LIMITED PHOTOGRAMMETIC DATA DUE TO LEAF ON CONDITIONS DURING THE APRIL 17TH FLIGHT. INFORMATION SHOWN IN OBSCURED AREAS IS FOR REFERENCE ONLY. 7. CONTOURS SHOWN UNDERWATER IN THE 1985 & 1978 ASH POND PER BATHYMETRIC SURVEYS CONDUCTED BY WSP IN AUGUST 2013. 8. FLOOD LINES SHOWN HEREON ARE FOR REFERENCE ONLY, PER WWW.FRIS.NC.GOV. 9. PORTIONS OF THE MAPPED AREA ARE WITHIN A FLOOD HAZARD AREA ACCORDING TO FLOOD INSURANCE RATE MAPS: 3710968600K PANEL 9686 LAST REVISED 02/02/07 3710968700K PANEL 9687 LAST REVISED 02/02/07 3710969600J PANEL 9696 LAST REVISED 02/02/07 3710969700J PANEL 9697 LAST REVISED 02/02/07 10. SWITCHYARD AND / OR SUBSTATION INFORMATION SHOWN HEREON INSIDE THE FENCE LINE IS FROM PHOTOGRAMMETRIC MAPPING ONLY. 11, ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. 12. THE AREA SHOWN HEREON WAS COMPUTED USING THE COORDINATE COMPUTATION METHOD. 13. LINES NOT SURVEYED ARE SHOWN AS BROKEN LINES FROM INFORMATION REFERENCED ON THE FACE OF THIS PLAT. 14. PROPERTY SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. 15. INFORMATION SHOWN ON PRIVATE PROPERTY IS FOR REFERENCE ONLY. CAM WM NO= THE FOLLOWING INFORMATION WAS USED TO OBTAIN NC GRID, NAD83(2011)/NAVD88 STATE PLANE COORDINATES (SPC) FOR THIS PROJECT: CLASS OF SURVEY: URBAN LAND SURVEYS (CLASS A) POSITIONAL ACCURACY: 0.01' TYPE OF GPS FIELD PROCEDURE: VRS DATE OF SURVEY: APRIL 9, 2014 & APRIL 17, 2014 DATUM/EPOCH: NAD83(2011) PUBLISHED/FIXED-CONTROL USED: VRS GEOID MODEL: GEOID12A COMBINED GRID FACTOR: 0.999880362 UNITS: US SURVEY FEET GRID/GROUND PIONT: Y(N) 670,107.32 X(E) 1,985,557.88 PREVIOUSLY MAPPED ASH AREA: 381 +/- ACRES 1111111111111111111111111� 1111111111111111111111111■ TOTAL MAPPED AREA: 999 +/- ACRES (INCLUDING ASH AREA) CAPE FEAR AERIAL TARGET POM # NORTHING EASTING ELEV. 1 664,692.40 1,991,311.77 247.61 2 662,642.14 1,984,238.38 231.14 3 663,230.06 1,988,981.80 186.04 4 675,916.93 1,981,864.30 193.46 5 674,302.97 1,985,955.82 180.42 6 674,727.61 1,990,007.17 191.30 7 668,881.98 1,982,828.78 173.32 8 671,015.54 1,986,775.04 171.81 9 668,900.83 1,991,043.60 220.59 CAPE FEAR OONIROL POINTS # NORTHING EASTING ELEV. DESC. 50003 671,766.15 1,985,030.05 189.10 REBAR 50004 672,086.81 1,985,567.96 188.28 REBAR 6111 670,541.87 1,987,404.71 199.95 NAIL 6113 670,213.96 1,987,921.44 199.27 NAIL 10004 668,074.26 1,986,334.29 195.52 REBAR 10005 667,740.76 1,985,857.97 195.72 REBAR / / / / / / / / / / / / / / T / 7 / 1jJ� 1 / / / / / / / / / / / I / / I / / / I / / / / / II/ V / / / / / / / / / / / / / / CAPE FEAR PLANT MONCURE, CHATHAM COUNTY, NORTH CAROLINA / / / / / / / / / / / / / / / I I I I I I i I I I I I I I I -----------7-- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 , \ \ .i ' '/ // it / \ `\-�•��', �, I J I ' � �'��i' %Ij � /- ;1Vjl j�i � 7[� \I\\' 1 \\\ 1 I//' `\ \\ � \\ `k[[•[i" / I \\ T I _ Al i V I Ilk / as \ / / \\� i I lilt//Ayo,'"%-. / 1 .. � ��,^` \ II `I- ` � `\ \ \ '-------/ i• / /Irll IlNlfidglir/9 / ♦ \ \ i __ \ \ \ / / \ 11 (1 --•� \�' � \ \\ \ \ \ \ ' / � r 7„ v�4 Try / � s V</,c ,�I�1 11��I141�IIIli�11 �` _^ III Il lllp _ I 1 ✓ ��✓/ // / ��, ' 11 11 ------� VICINITY MAP (N.T.S.) 1SM` B„ONEwSTORY METAL BUILDING 1SBB ONE STORY BLOCK BUILDING 2' INTERVAL CONTOURS OBSCURED AREAS* 2' INTERVAL CONTOURS OPEN AREAS 111111111111111■ 111111111111111■ AERIAL MAPPING LIMIT AERIAL MAPPING LIMIT - ASH AREA BFP BACK FLOW PREVENTER BIRD BIRD HOUSE - NESTING POLE BP® BLUE PIPES - VERTICAL CABLE BOX CAM-4 CAMERA POLE Cy CANOPY COO CLEAN OUT 0 EC CONCRETE SLAB - PAD CMP CORRUGATED METAL PIPE CPP CORRUGATED PLASTIC PIPE DRAIN LINE DRAINAGE CENTERLINE 0 DRAINAGE MANHOLE m DROP INLET DRAIN O ELECTRIC MANHOLE ES QE ELECTRIC SERVICE BOX - PANEL -X-X-X-X-X-X- FENCE LINE - CHAIN LINK FENCE LINE - OTHER FPO FLAG POLE FOo FIBER OPTIC LINE MARKER oFIRE FIRE BOX (� FIRE HYDRANT FLOOD LINE (SEE NOTE #8) GM ® GAS LINE MARKER GAS 0 GAS VALVE GRAVEL / DIRT PATH GH GUARD HOUSE GUARD RAIL IV O INDICATOR VALVE - WATER IRR IRRIGATION CONTROL KP • KEYPAD - GATE CALL BOX LIGHT POLE MB MAIL BOX O MANHOLE - UNKNOWN MANHOLE - SANITARY SEWER YMH QO MANHOLE - PAINTED YELLOW MW 0 MONITOR WELL OVERHEAD UTILITIES - PATH - TRAIL PAVED SURFACE © © POOL - INGROUND - ABOVE GROUND 0 POST PROPERTY LINE (GIS) - PROPERTY LINE (GIS-DUKE ENERGY) RCP REINFORCED CONCRETE PIPE I / SIGN 12&8 X SPOT ELEVATION 11 OX SPOT ELEVATION ESTIMATED OBSCURED AREAS 0 STORM DRAIN OTANK TELEPHONE PEDESTAL TSTA TEST STATION TF TRANSFORMER TR O TRAILER - MOBILE JOB SITE OFFICE TREE / BRUSH LINE X UNIDENTIFIED UTILITIES / STRUCTURES / OBJECTS ¢ ® UTILITY POLE / TRANSMISSION POLE / TRANS. TOWER ® VAULT O VAG VAULT ABOVE GROUND Ve VALVE PVC a VERTICAL PVC OW WATER METER WV A WATER VALVE WVT WATER VAULT WATER WELL .lt_� ltl ]t• 7� 1� OBSCURED AREA T 7Tf/ TT� E7�7 SWITCHYARD %%7777j WATER LLLL _j WET AREA * SEE GENERAL NOTES