HomeMy WebLinkAboutNC0003433_Vert Hydraulic Cond_20150902B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE - CAPE FEAR TESTED BY: JOHN MATHEW J15-5612-03 CHECKED BY: PAUL YARBER 3-31-15 SAMPLE NO. ABMW-01 AB SAMPLE LOCATION: 5.0-7.0' TYPE UNDISTURBED SAMPLE DESCRIPTION: DARK GREY FI: MED. SANDY SILT SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.983 7.577 2.978 7.564 Sample Diameter 2.867 7.282 2.860 7.264 Length/Diameter Ratio 1.04 Moisture Content (°/o) WW- 151.9 DW- 111.4 36.3 WW= 176.2 DW- 117.8 49.6 Sample Wet Weight (grams) 448.4 479.8 Wet Density cf) 88.7 95.5 IDry Density ( cf) 65.1 63.9 Saturation (%) �= so= 2.254 70 93 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT FALLING HEAD TEST Confining Pressure (psi) 64.5 Influent Pressure (psi) 60.2 Effluent Pressure (psi) 60.0 B-Value 0.96 Date Clock Time Elapsed Time seconds Pipet Readings Head Temp °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Initial Final Initial cm Final cm Start End in out in out 7-10-15 10:30:55 10:32:04 69 1.0 23.0 3.0 21.0 40.092 35.361 21.0 5 1.4E-04 0.976 1.4E-04 7-10-15 10:32:04 10:33:19 75 3.0 21.0 5.0 19.0 35.361 30.629 21.0 5 1.5E-04 0.976 1.4E-04 7-10-15 10:33:19 10:34:47 88 5.0 19.0 7.0 17.0 30.629 25.897 21.0 5 1.5E-04 0.976 1.4E-04 7-10-15 10:34:47 10:36:37 110 7.0 17.0 9.0 15.0 25.897 21.166 21.0 5 1.4E-04 0.976 1.4E-04 Pipet Length, cm ---- -------------- Pipet Volume, cc ------------------ Cross -sectional Area of Pipet, cm2 28.390 ------ 24 ------ 0.84541 28.390 ------ 24 ------ 0.8454 HYDRAULIC CONDUCTIVITY (K20-C) 1.4E-04 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE - CAPE FEAR J15-5612-03 5-29-15 SAMPLE NO. ABMW-3 SAMPLE LOCATION: 30.0-32.0' TYPE UNDISTURBED SAMPLE DESCRIPTION: GREY FI. SANDY CLAY SAMPLE DIMENSIONS AND PROPERTIES TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.935 7.455 2.828 7.183 Sample Diameter 2.861 7.267 2.839 7.211 Length/Diameter Ratio 1.03 Moisture Content (%) ww= 179.8 Dw= 139.3 29.1 ww= 207.4 Dw= 167.1 1 24.1 Sample Wet Weight (grams) 593.9 576.5 Wet Density (cf) 119.9 122.7 Dry Density cf) 92.9 98.8 Saturation (%) TESTED SG-- 2.695 97 93 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 80.6 Influent Pressure (psi) 60 Effluent Pressure (psi) 60 B-Value 0.96 Reset (Y/N) Date Clock Time Elapsed Time HAoUT HAjN Temp cm (cm °C Gradient K (cm/sec) Temp Correction K20°C (cm/sec) Y 7-9-15 4:04:25 7.6 1.87 21.0 10 7-9-15 4:06:18 0:01:53 6.0 1.94 21.0 7 1.3E-06 0.976 1.3E-06 7-9-15 4:07:02 0:02:37 5.5 1.96 21.0 7 1.3E-06 0.976 1.3E-06 7-9-15 4:07:53 0:03:28 5.0 1.98 21.0 1 6 1 1.3E-06 0.976 1.3E-06 7-9-15 4:08:51 0:04:26 4.5 2.00 21.0 1 5 1 1.3E-06 0.976 1.3E-06 HYDRAULIC CONDUCTIVITY (K20.0 1.3E-06 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE - CAPE FEAR J15-5612-03 5-29-15 SAMPLE NO. MW-16 SAMPLE LOCATION: 0.0-2.0' TYPE UNDISTURBED SAMPLE DESCRIPTION: GREY FI. SANDY CLAY SAMPLE DIMENSIONS AND PROPERTIES TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.968 7.539 2.966 7.534 Sample Diameter 2.868 7.285 2.843 7.221 Length/Diameter Ratio 1.03 Moisture Content (%) 7WW15.9 Dw= 176.3 22.5 WW= 215.6 Dw= 174.4 23.6 Sample Wet Weight (grams) 634.9 636.2 Wet Density (cf) 126.1 128.7 Dry Density cf) 103.0 104.1 Saturation (%) TESTED sc= 2.665 97 100 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 62 Influent Pressure (psi) 60 Effluent Pressure (psi) 60 Q-Value 0.96 Reset (Y/N) Date Clock Time Elapsed Time HAoUT HAIN Temp cm cm °C Gradient K (cm/sec) Temp Correction K20'C (cm/sec) Y 7-8-15 3:49:28 7.3 1.47 21.0 10 7-8-15 3:59:21 0:09:53 6.7 1.50 21.0 9 8.4E-08 0.976 8.2E-08 7-8-15 4:01:10 0:11:42 6.6 1.50 21.0 9 8.4E-08 0.976 8.2E-08 7-8-15 4:03:05 0:13:37 6.5 1.50 21.0 9 8.3E-08 0.976 8.1E-08 7-8-15 4:05:01 0:15:33 6.4 1.51 21.0 9 8.3E-08 0.976 8.1E-08 HYDRAULIC CONDUCTIVITY (K20.0 8.2E-08 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE - CAPE FEAR J15-5612-03 3-31-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. MW-17 BR SAMPLE LOCATION: 5.0-7.0' TYPE UNDISTURBED SAMPLE DESCRIPTION: GREY & BROWN FI. SANDY CLAY SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.927 7.435 2.704 6.868 Sample Diameter 2.860 7.264 2.882 7.320 Length/Diameter Ratio 1.02 Moisture Content (%) ww= 161.4 Dw= 120.8 33.6 ww= 158.2 Dw= 123. 27.7 Sample Wet Weight (grams) 577.0 554.6 Wet Density (cf) 116.9 119.8 Dry Density cf) 87.5 93.8 Saturation (%) TESTED so= 2.645 100 96 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) 65.7 Influent Pressure (psi) 60 Effluent Pressure (psi) 60 B-Value 0.96 Reset (Y/N) Date Clock Time Elapsed Time HAoUT HAIN Temp cm cm °C Gradient K (cm/sec) Temp Correction K20°C (cm/sec) Y 7-8-15 3:21:38 7.2 1.47 21.0 11 7-8-15 3:28:29 0:06:51 6.5 1.50 21.0 10 1.3E-07 0.976 1.3E-07 7-8-15 3:29:31 0:07:53 6.4 1.51 21.0 9 1.3E-07 0.976 1.3E-07 7-8-15 3:30:45 0:09:07 6.3 1.51 21.0 9 1.3E-07 0.976 1.2E-07 7-8-15 3:32:06 0:10:28 1 6.2 1.52 21.0 9 1 1.3E-07 0.976 1.2E-07 HYDRAULIC CONDUCTIVITY (K20.0 1.3E-07 cm/sec B L E INC. PROJECT: PROJECT NO.: DATE RECEIVED: HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) SYNTERRA DUKE - CAPE FEAR J15-5612-03 5-29-15 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER SAMPLE NO. MW-21 SAMPLE LOCATION: 17.0-20.0' TYPE UNDISTURBED SAMPLE DESCRIPTION: BROWN FI. SANDY CLAY SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 2.952 7.498 2.842 7.219 Sample Diameter 2.868 7.285 2.867 7.282 Length/Diameter Ratio 1.03 Moisture Content (%) 7WW-.5 Dw= 160.7 22.3 WW= 200.0 DW- 167.6 19.3 Sample Wet Weight (grams) 638.8 620.0 Wet Density (cf) 127.6 128.7 Dry Density cf) 104.4 107.9 Saturation (%) TESTED SCr- 2.695 99 94 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi) Reset Date (Y/N) 74 Influent Pressure (psi) 60 Clock Time Elapsed Time HAoUT (cm HAIN (cm Effluent Pressure (psi) Temp Gradient °C 60 K (cm/sec) B-Value Temp Correction 0.96 K20'C (cm/sec) Y 7-9-15 3:37:28 10.5 1.34 21.0 16 7-9-15 3:44:05 0:06:37 10.2 1.35 21.0 16 3.6E-08 0.976 3.6E-08 7-9-15 3:46:10 0:08:42 10.1 1.36 21.0 16 3.7E-08 0.976 3.6E-08 7-9-15 3:48:28 0:11:00 10.0 1.36 21.0 15 3.7E-08 0.976 3.6E-08 7-9-15 3:51:02 0:13:34 9.9 1.36 21.0 15 3.6E-08 0.976 3.5E-08 HYDRAULIC CONDUCTIVITY (K20.0 3.6E-08 cm/sec