Loading...
HomeMy WebLinkAboutNC0026247_CEI_Letter_20231108ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director NORTH CAROLINA Environmental Quality November 8, 2023 Transmontaigne Operating Company LP Attn: Dudley Tarlton, ESOH VP 1670 Broadway Street Denver, CO 80202 SUBJECT: Compliance Evaluation Inspection Southeast Terminal NPDES Permit Number: NCO026247 Guilford County Dear Mr. Tarlton: On November 2nd, 2023, NC Division of Water Resources staff, Ron Boone, conducted a compliance evaluation inspection of NPDES permit NCO026247 for Transmontaigne Operating Company's Southeast Terminal, located at 6801 West Market Street in Greensboro, NC. Terminal Manager, Daryll Freeman, was present for the inspection. The inspection revealed that Transmontaigne is fully compliant with NPDES permit NC0026247. No concerns, deficiencies, or violations were noted during the inspection. The attached Water Compliance Inspection Report provides more details about the inspection and what it entailed. Please contact Mr. Boone by phone at 336.776.9690 or by email at ron.boone@deq.nc.gov, if you have any questions or concerns. Sincerely, DocuSigned by: 5 JenniferFi�'raznak, Assistant Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Attachments: Water Compliance Inspection Report cc: Daryll Freeman, Terminal Manager, via email DffNorth Carolina Department of Environmental Quality I Division of Water Resources oan caaouNn Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105 M336.776.9800 oep.m.m or em����� o�.im, United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO026247 I11 121 23/11/02 I17 18I � I 19 I s I 201 I 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 11:00AM 23/11/02 22/08/01 Southeast terminal 6801 W Market St Exit Time/Date Permit Expiration Date Greensboro NC 27409 11:45AM 23/11/02 26/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Not Required/ORC/919-807-6353/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Barbara Castleberry,200 Mansell Ct E Roswell GA 30076//770-518-3671/7706503329 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone Docusigned by: DWR/WSRO WQ/336-776-9690/ o*%,*& Boone' 11/8/2023 B20F8DD5F2A3460... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date DocuSigned by: 11/8/202 3 DwR/wslto 336-776-9695 "-OD2D3CE3F 1 B7456_. EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO026247 I11 12I 23/11/02 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On November 2nd, 2023, NC Division of Water Resources staff, Ron Boone, conducted a compliance evaluation inspection of NPDES permit NC0026247 for Transmontaigne Operating Company's Southeast Terminal, located at 6801 West Market Street in Greensboro, NC. Terminal Manager, Daryll Freeman, was present for the inspection. The inspection findings are detailed below. This facility consists of several independent containment areas that all drain and discharge to a common outfall 001. The containment areas are for the rail spur ethanol off loading area, two containment areas for the petroleum above ground storage tanks, and a containment area for the fuel truck loading rack. The fuel truck loading rack is covered and all petroleum contact water (PCW) is captured from the rack and goes to a PCW tank which is pumped off by environmental contractors periodically and taken elsewhere for proper disposal. The facility uses an inline meter for measuring the effluent flow. It is calibrated annually by City of Greensboro Water Resources Department. It is currently out for calibration and the city has provided a spare meter to Transmontaigne that they may install temporarily in the event that they must discharge while their regular meter is out for calibration. The facility uses SM&E and Pace Environmental for sample collection and analyses. Discharge monitoring and laboratory reports were reviewed. No errors were noted. All required records, including the chains of custody, were noted as correct and complete. Operators visitation logs were also complete. The entire facility appeared to be very clean and well maintained. Mr. Boone noted no concerns, discrepancies, or violations. Please contact Mr. Boone by phone at 336.776.9690 or by email at ron.boone@deq.nc.gov, if you have any questions or concerns. Page# Permit: NCO026247 Inspection Date: 11/02/2023 Owner -Facility: Southeast terminal Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: None Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Comment: Certified operator is not required. Facility uses Environment 1 for non -field analses except for toxicity, for which they use Meritech. Laboratory Yes No NA NE Page# 3 Permit: NCO026247 Inspection Date: 11/02/2023 Owner -Facility: Southeast terminal Inspection Type: Compliance Evaluation Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Comment: None Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Yes No NA NE ❑ ❑ ■ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ Comment: Facility uses Environment 1 for non -field analses except for toxicity, for which they use Meritech. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ■ ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? ❑ 0 ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: City of Greensboro Water Resources Department calibrates the facilitv's discharqe meter. It is currently out for calibration. The city pave the facility a spare meter to install and use to measure the discharge must in case they must discharge while the regular meter is out being calibrated. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: No discharge at time of inspection. Page# 4 Permit: NCO026247 Inspection Date: 11/02/2023 Effluent Pipe Owner -Facility: Southeast terminal Inspection Type: Compliance Evaluation Yes No NA NE Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: None Page# 5