Transmontaigne Operating Company LP
Attn: Dudley Tarlton, ESOH VP
1670 Broadway Street
Denver, CO 80202
SUBJECT: Compliance Evaluation Inspection
Southeast Terminal
NPDES Permit Number: NCO026247
Guilford County
Dear Mr. Tarlton:
On November 2nd, 2023, NC Division of Water Resources staff, Ron Boone, conducted a compliance
evaluation inspection of NPDES permit NCO026247 for Transmontaigne Operating Company's Southeast
Terminal, located at 6801 West Market Street in Greensboro, NC. Terminal Manager, Daryll Freeman,
was present for the inspection.
The inspection revealed that Transmontaigne is fully compliant with NPDES permit NC0026247. No
concerns, deficiencies, or violations were noted during the inspection. The attached Water Compliance
Inspection Report provides more details about the inspection and what it entailed.
Please contact Mr. Boone by phone at 336.776.9690 or by email at ron.boone@deq.nc.gov, if you have
any questions or concerns.
Sincerely,
DocuSigned by:
5
JenniferFi�'raznak, Assistant Regional Supervisor
Water Quality Regional Operations Section
Winston-Salem Regional Office
Division of Water Resources, NCDEQ
Attachments:
Water Compliance Inspection Report
cc: Daryll Freeman, Terminal Manager, via email
DffNorth Carolina Department of Environmental Quality I Division of Water Resources
oan caaouNn
Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105
M336.776.9800
oep.m.m or em����� o�.im,
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 u 3 I NCO026247 I11 121 23/11/02 I17 18I � I 19 I s I 201 I
211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
I 72 I ni I 71 I 74 79 I I I I I I I80
701 I 71 I LL -1 I I
LJ
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Dermit Number)
11:00AM 23/11/02
22/08/01
Southeast terminal
6801 W Market St
Exit Time/Date
Permit Expiration Date
Greensboro NC 27409
11:45AM 23/11/02
26/08/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Not Required/ORC/919-807-6353/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Barbara Castleberry,200 Mansell Ct E Roswell GA 30076//770-518-3671/7706503329
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Ron Boone Docusigned by: DWR/WSRO WQ/336-776-9690/
o*%,*& Boone' 11/8/2023
B20F8DD5F2A3460...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
DocuSigned by: 11/8/202 3
DwR/wslto 336-776-9695
"-OD2D3CE3F 1 B7456_.
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCO026247 I11 12I 23/11/02 117 18 i c i
(Cont.)
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
On November 2nd, 2023, NC Division of Water Resources staff, Ron Boone, conducted a compliance
evaluation inspection of NPDES permit NC0026247 for Transmontaigne Operating Company's
Southeast Terminal, located at 6801 West Market Street in Greensboro, NC. Terminal Manager,
Daryll Freeman, was present for the inspection. The inspection findings are detailed below.
This facility consists of several independent containment areas that all drain and discharge to a
common outfall 001. The containment areas are for the rail spur ethanol off loading area, two
containment areas for the petroleum above ground storage tanks, and a containment area for the
fuel truck loading rack.
The fuel truck loading rack is covered and all petroleum contact water (PCW) is captured from the
rack and goes to a PCW tank which is pumped off by environmental contractors periodically and
taken elsewhere for proper disposal.
The facility uses an inline meter for measuring the effluent flow. It is calibrated annually by City of
Greensboro Water Resources Department. It is currently out for calibration and the city has provided
a spare meter to Transmontaigne that they may install temporarily in the event that they must
discharge while their regular meter is out for calibration.
The facility uses SM&E and Pace Environmental for sample collection and analyses. Discharge
monitoring and laboratory reports were reviewed. No errors were noted. All required records,
including the chains of custody, were noted as correct and complete. Operators visitation logs were
also complete.
The entire facility appeared to be very clean and well maintained. Mr. Boone noted no concerns,
discrepancies, or violations.
Please contact Mr. Boone by phone at 336.776.9690 or by email at ron.boone@deq.nc.gov, if you
have any questions or concerns.
Page#
Permit: NCO026247
Inspection Date: 11/02/2023
Owner -Facility: Southeast terminal
Inspection Type: Compliance Evaluation
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment: None
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
❑ ❑ ■ ❑
■ ❑ ❑ ❑
❑ ■ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
■ ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
❑ ❑ ■ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
❑ ❑ ■ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
Comment: Certified operator is not required. Facility uses Environment 1 for non -field analses
except for toxicity, for which they use Meritech.
Laboratory
Yes No NA NE
Page# 3
Permit: NCO026247
Inspection Date: 11/02/2023
Owner -Facility: Southeast terminal
Inspection Type: Compliance Evaluation
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Comment: None
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Yes
No
NA
NE
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
❑
❑
❑
■
❑
❑
■
❑
❑
❑
■
❑
Yes No NA NE
❑ ❑ ■ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ■ ❑
❑ ❑ ❑ ■
■ ❑ ❑ ❑
Comment: Facility uses Environment 1 for non -field analses except for toxicity, for which they use
Meritech.
Flow Measurement - Effluent
Yes
No
NA
NE
# Is flow meter used for reporting?
■
❑
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
❑
0
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
0
❑
Comment: City of Greensboro Water Resources Department calibrates the facilitv's discharqe
meter. It is currently out for calibration. The city pave the facility a spare
meter to install
and use to measure the discharge must in case they must discharge while the regular
meter is out being calibrated.
Effluent Pipe
Yes
No
NA
NE
Is right of way to the outfall properly maintained?
0
❑
❑
❑
Are the receiving water free of foam other than trace amounts and other debris?
❑
❑
❑
If effluent (diffuser pipes are required) are they operating properly?
❑
❑
0
❑
Comment: No discharge at time of inspection.
Page# 4
Permit: NCO026247
Inspection Date: 11/02/2023
Effluent Pipe
Owner -Facility: Southeast terminal
Inspection Type: Compliance Evaluation
Yes No NA NE
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: None
Page# 5