Loading...
HomeMy WebLinkAboutWQ0044608_Application (FTSE)_20230912DWR State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRUCTIONS FOR FORM: FTA 06-21 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria (Gravity Sewer & Pump StatiomTorce Mains) and that plans, specifications and supporting documents have been prepared in accordance with 15_A NCAC 02T,15A NCAC 02T. Division policies, and good engineering practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be immediately available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that do not meet any part of the minimum design criteria (MDC) documents; ➢ Projects that involve more than one variance from the requirements of 15A NCAC 02T; ➢ Pressure sewer systems utilizing simplex septic tank -effluent pumps (STEPs) or simplex grinder pumps; ➢ Simplex STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ➢ Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy (second copy may be digital) of Application and Supporting Documents ® Required unless otherwise noted. Signatures on original must be "wet ink" or secure digital signatures. Please do not submit engineering design plans with the application unless specifically requested. B. Cover Letter/Narrative Description (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ Include the permit number/status of any other required sewer permits (downstream/upstream) ➢ If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Modification Application Packages): ® Submit a check or money order in the amount of $480.00, dated no more than 90 days prior to application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track Application (Required for All Application Packages, Form FTA 05-21): ® Submit the completed and appropriately executed application. ➢ If necessary for clarity or due to space restrictions, attachments to the application may be made. ❑ If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secremy of State. ❑ If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item II.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02'r .0106 b . Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 06-21 & SUPPORTING DOCUMENTATION Page 1 of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. ➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G. S. 143-215.67 a . ➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area, including the closest surface waters. ➢ General location of the project components (gravity sewer, pump stations, & force main) ➢ Downstream connection points and permit number (if known) for the receiving sewer ® Include an aerial location map showing general project area (such as street names or latitude/longitude) so that Division staff can easily locate it in the field. G. Existing Permit (Application Packages for Modifications to an Existing Permit): ❑ Submit a copy of the most recently issued existing permit. ❑ Include a descriptive and clear narrative identifying the previously permitted items to remain in the permit, items to be added, and/or items to be modified (the application form itself should include only include items to be added/modified). The narrative should also include whether any previously permitted items have been certified. ❑ The narrative should clearly identify the requested permitting action and accurately describe the sewers to be listed in the final permit. H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A_ NCAC 02T .0305(h)(1), submit documentation of power reliability for pumping stations. ➢ This alternative is only available for average daily flows less than 15,000 gallons per day ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Property Owners' Associations ❑ Per 15A NCAC 02T .0115(cl, submit the properly executed Operational Agreement (FORM: HOA). ❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T .0I 15(b). submit the properly executed Operational Agreement (FORM: DEV). For more information, visit the Division's collection systems website INSTRUCTIONS FOR FORM: FTA 05-21 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778-8211 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5095 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 3800 Barrett Drive Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27609 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 571-4718 Fax Warren, Wilson Washington Regional Office Water Quality Section Wilmington Regional Office Water Quality Section Winston-Salem Regional Office Water Quality Section 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Wilmington, North Carolina 28405 Hanover, Onslow, Pender (910)796-7215 (910) 350-2004 Fax 450 W. Hanes Mill Road Alamance, Alleghany, Ashe, Caswell, Davidson, Suite 300 Davie, Forsyth, Guilford, Rockingham, Randolph, Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 776-9800 (336) 776-9797 Fax INSTRUCTIONS FOR FORM: FTA 05-21 & SUPPORTING DOCUMENTATION Page 3 of 3 State of North Carolina Department of Environmental Quality DWR Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Divlslon of Water Resources FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: WQ0044608 (to be completed by DWR) �' a) All items must he completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Mebane (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Chris Rollins per I5A NCAC 02T .0106(b) Title: City Manager 4. Applicant's mailing address: 106 E. Washington Street City: Mebane State: NC Zip: 27302 5. Applicant's contact information: Phone number: (919) 562-5901 Email Address: crollins _ cityof mebane.com II. PROJECT INFORMATION: ❑ Privately -Owned Public Utility ❑ Other 1. Project name: Oakwood Subdivision Phase 1 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Orange County 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.087839 ° Longitude:-79.251508' 5. Parcel ID (if applicable): 9825404628.9825502531, 9825601982 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: William R. Wirt License Number: 052574 Firm: Summit Design and Engineering Services Mailing address: 320 Executive Court City: Hillsborough State: NC Zip: 27278 Phone number: (919) 732-3883 Email Address: williarn.wirt@summitde.corn IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Q of Mebane Water Resource Recovery Facilit Permit Number: NCO021474 Owner Name: City of Mebane V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ0032351 2. Downstream (Receiving) Sewer Information: 8" inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00081 Owner Name(s): City of Mebane FORM: FTA 06-21 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [—]Yes [—]No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic 0 % Commercial 0 % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ®Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a'" No. of Units Flow Single Family homes/ Townhomes 240 gal/gpd 144 34,560 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 34,560 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 34,560 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 4,530 LF PVC 8" 843 LF DIP 12" 1915 LF PVC 12" 567 LF DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.l.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with I5A NCAC 02T .0305 h 1 : ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(13)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(O & W? ® Yes ❑ No 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches zWater mains (vertical - water over sewer preferred, including in benched trenches) 18 inches zWater mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(fl or (g), see Section X.1 of this application *15A NCAC 02T.0305 contains alternatives where separations in 02T.0305(fl cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webyage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes [:]No ❑ N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes [—]No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Cape Fear ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 213.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ® Yes ❑ No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T,0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Pern>itting of Pump Stations and Force Mains latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects reguirina a variance aut3roval may be subiect to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a sianifieant portion of the project, the full technical review is required. 2. Professional Engineer's Certification: I, WILLIAM R. WIRT, attest that this appliAtion for Oakwood Phase I (Professional Engineer's name from Application Item III.1.) (Project Name from Application Item II.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravies Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitling of Pump Stations and Force Mains. (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: -' % SEAL 74 J- fir. �'��'•:Y�L�it" •� \1��-� `� `!^� AIMI R 1�,``,. 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, CHRIS ROLLINS, CITY OF MANAGER, attest that this application for Oakwood Subdivision Phase I (Signature Authority Name from Application Item 1.3.) (Project Name from Application Item II.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: �1 0Z3 FORM: FTA 06-21 Page 5 of 5 CDeptofEr�viromcntal Environmental Quality State of North Carolina QualiD,W-: Rty Department of Division of Water Resources Dtvlslon of Water Resources JUL 2 4 2023 Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: City of Mebane f Project Name for which flow is being requested: Oakwood Subdivision Phase 1 More than one FTSE maybe required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: City of Mebane Water Resource Recovery Facility b. WWTP Facility Permit #: NC 0021474 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 2.500 0.3473 1.5330 0.0346 1.9149 77% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station Firm (Name or Permit Capacity, Number) No. MGD SE Regnl WQ0031329 2.505 (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Average Approx. Obligated, Daily Current Not Yet Total Current Flow** Avg. Daily Tributary Flow Plus (Firm / pf), Flow, Daily Flow, Obligated Available MGD MGD MGD Flow Capacity*** 1.002 0.238 0.159 0.397 0.605 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is ¢ 0. Downstream Facility Name (Sewer): City of Mebane Downstream Permit Number: W 0030944 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Chris Rollins certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and I1 plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature L'A `Holm Title of Signing 2a 14o40 Date Page 2 of 6 FTSE 10-18 NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Govemor Robert L. Wilson City Manager City of Mebane 106 East Washington Street Mebane, NC 27302 Subject: Mebane WWTP (NC0021474) Flow Reduction Request Alamance County Dear Mr, Wilson: Coleen H. Sullins DireMr March 15, 2011 Dee Freeman Secretary On February 14, 2011, the Pretreatment, Emergency Response and Collection System (PERCS) Unit of the Division of Water Quality received a flow reduction request for connections to the City of Mebane WWTP. The letter requests an allowable flow rate of 80 gallons per day (gpd) per bedroom based on the evaluated data. As daily WWTP data is not representative of the project area, the DMR data from the City of Mebane WWTP (NC0021474) from January 2009 through December 2009 was evaluated to determine the peak sewage month. The highest flow month was December 2009. Daily wastewater flows were recorded downstream of the Holly Ridge Subdivision during December 2010. This data was reviewed by PERCS and Regional Office staff. Based on the data, the Division hereby grants a reduction in flow to 80 gpd/bedroom (minimum of 160 gpd for 1 and 2 bedroom residences) for sewer extension permits issued tributary to the City of Mebane WWTP. Regardless of the adiusted design daily wastewater flow rate, at no time shall the wastewater flows exceed the effluent limits defined in the NPDES permit for the treatment facifily or exceed th cUffifty of the sewers downstream of any new sewer extension or service connection(s). If you have any questions or comments regarding this matter, please contact Sarah Morrison at (919) 807-6310, or email [Samh.Morrison@ncdenr.gov] or Deborah Gore, Unit Supervisor at (919) 807-6383, or email [Deborah.Gore@ncdenr.gov]. Sincerely, .;,( Coleen H. Sullins cc: Darrell L. Russell, P.E., Alley, Williams, Carmen & King, Inc. (via email: dnrssell@awck.com) Steve Mauney, Winston-Salem Regional Office (via email) NPDES Unit, Permit File NCO021474 PERCS Flow Reduction File 1617 Mall 5ervioe Center, Raisigh, Noah Carolina 27699-1617 LocaWA: 512 N. salbbury St Raleigh, North Carolina 27604 Re Caro ina Phone: 919-807-M0 9$0 FAX: 917.84921 PERCS Unit FAX: 919-807-64891 Customer Servioe: 1-077.623-6748 Internet ht WIDDrtal.nodenr.oralweblrval PERCS Unit An Equal f! l.rt r iQturaCl� Equal Opporlurily %Af nallve Action Employer �£ & 2 CL U AMA �g a ƒ _� � � \2 ® T j(-If F-f AJ&AaON ' k 0 3 �e r " � 6 �, . C 2 C E� acn k� f/ ƒ a 2 7 'E co � o \ �5 � oc 0 Mat,m, f UoN �_ \ . um 2 S Cc cn 2 0 k / \ oI c « w �k k/ �� �� 0 \ / k � / f E 2 u « a ®� ®®m,� $® / f Lek ® _ w k b SE+e% k LS®®� MA3 _ 0 \ / o 6 § � L s,m k off° \ m 2 ' °\ 2 � R, Ave cm `cu u / �m §0 C � / / Permit Number WQ0032351 P SR U SR 1007 If ' Permit Number �,e_� WQ0031329 p \ \ I 07 \ r P SE Regional Pump Station Permit Number WQ0031329 SR Oakwood Sewer Flow Diagram I 1 I 1 I 1 , I 1 1 1 0g �® /R PROPOSED GRAVITY y i R' SEWER K �® I �®® Wilson Road 1 ®jam , " a 5 r. - � o a 0 Quarry Lake 0 LJ Danny Drive 0 a owman Q° mac a / Map data © OpenStreetMap contributors, Microsoft, FaCE Community Maps e Aane - Positively Charming PUBLIC SERVICE CONTACTS: WATER: CITY OF MEBANE PUBLIC WORKS DEPT. STATE ROADWAYS: NCDOT - DIVISION 7, DISTRICT 1 KYLE SMITH CHARLES N. EDWARDS (CHUCK), PE 636 CORRIGIDOR STREET DISTRICT ENGINEER MEBANE, NC 27302 115 E. CRESCENT SQUARE DRIVE (919) 563-3401 PO BOX 766 GRAHAM, NC 27253 SEWER: CITY OF MEBANE PUBLIC WORKS DEPT. (336) 570-6833 KYLE SMITH 636 CORRIGIDOR STREET PLANNING: CITY OF MEBANE MEBANE, NC 27302 CY STOBER, AICP (919) 563-3401 DEVELOPMENT DIRECTOR 102 S. 5TH STREET FIRE: CITY OF MEBANE MEBANE, NC 27302 BOB LOUIS, CHIEF (919) 563-9990 450 N. FIRST STREET MEBANE, NC 27302 SOLID WASTE: CITY OF MEBANE PUBLIC WORKS DEPT. (919) 563-5718 106 E. WASHINGTON STREET MEBANE, NC 27302 GAS: PSNC ENERGY / DOMINION ENERGY (919) 563-5901 BRIAN SMITH 2541 WHILDEN DRIVE RECYCLING: WASTE INDUSTRIES DURHAM, NC 27713 703 E. GILBREATH STREET (919) 598-7454 GRAHAM, NC 27253 BRIAN.SMITH@SCANA.COM (336) 229-0525 ELECTRIC: DUKE ENERGY, CAROLINAS EROSION CONTROL: ORANGE COUNTY PLANNING & INSPECTIONS DEPT. 1205 N. CHURCH STREET STEVE KALTENBACH BURLINGTON, NC 27217 EROSION CONTROL & STORMWATER OFFICER II (336)538-1677 131 W. MARGARET LANE HILLSBOROUGH, NC 27278 TELEPHONE: AT&T (919) 245-2587 AARON BOYKINS (336) 508-3237 ENGINEER CONTACT SUMMIT DESIGN & ENGINEERING SERVICES WILLIAM WIRT, PE 320 EXECUTIVE COURT HILLSBOROUGH, NC 27278 (919) 732-3883 (PHONE) (919) 732-6676 (FAX) WILLIAM.WIRT@SUMMITDE.COM OWNERS: MERITAGE HOMES OF THE CAROLINAS, INC. 13925 BALLANTYNE CORP. PLACE, STE. 300 CHARLOTTE, NC 28277 PHONE (919) 926-2607 4. Know what's below. Call before you dig. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. �p ! DEVELOPER: MERITAGE HOMES MARTIN FUCHS 3300 PARAMOUNT PARKWAY, SUITE 120 MORRISVILLE, NC 27560 PHONE (919) 926-2607 MARTIN.FUCHS@MERITAGEHOMES.COM � w= AIR SITE LOCATION MAP SCALE: 1" = 300' CONSTRUCTION DRAWINGS OAKWOOD PHASE 1 R-8 TOWNHOMES & R-10 SINGLE FAMILY LOTS ORANGE COUNTY, CHEEKS TOWNSHIP OAKWOOD STREET EXTENSION, MEBANE, NC 27302 TRC SUBMITTAL #1 : 07/14/2021 TRC SUBMITTAL #2 : 08/31/2021 TRC SUBMITTAL #3 : 10/26/2021 ORANGE COUNTY EROSION CONTROL SUBMITTAL #4: 12/6/2021 TRC SUBMITTAL #5 : 03/02/2022 TRC SUBMITTAL #6 : 08/19/2022 TRC SUBMITTAL #7 : 12/16/2022 TRC SUBMITTAL #8 : 04/05/2023 TRC SUBMITTAL #9 : 05/12/2023 FOR COM APPROVAL: 07/07/2023 ENGINEERING CONSTRUCTION PLAN REVIEW & INSPECTION FEES: STORMWATER MANAGEMENT FEES: 1. OVERALL PLAN REVIEW FOR COMPLIANCE = $2,500 2. REVIEW / INSPECTION PER DEVICE AT $1,500 EACH X 3 DEVICES = $4,500 TOTAL = $7,000 STREET, STORM WATER & UTILITY INSPECTION FEES A. PUBLIC STREETS 5,600 LF $3.00/LF = $ 16,800 B. WATER MAIN 3,335 LF $2.50/LF = $ 8,338 C. SEWER MAIN 7,855 LF $2.50/LF = $ 19,638 D. STORM DRAINAGE PRIVATE 3,251 LF $1.00/LF = $ 3,251 PUBLIC 4,983 LF $2.00/LF = $ 9,966 E. WATER & SEWER SERVICE 143 LOTS $200/LOT = $ 28,600 F. DRIVEWAYS 143 EA $100/EA = $ 14,300 G. SIDEWALK / MULTI -USE PATH PUBLIC SIDEWALK/PATH 3,214 LF $1.00/LF = $ 3,214 TOTAL = $104,107 VICINITY MAP SCALE: 1" = 2,000' Mebaneyi._ r7O � .4 � 1 b. r Q 11-- SITE =l + 1 ;I i 119 � • Ind (NJ] SHEET INDEX Sheet Number Sheet Title C-1 COVER SHEET C-2 GENERAL NOTES C-3 EXISTING CONDITIONS & STEEP SLOPES PLAN C-4 DEMOLITION PLAN C-5 OVERALL SITE & PHASING PLAN C-6 WINDING SPRING DR. - PROFILE 10+00 - 21+00 C-7 WINDING SPRING DR. - PROFILE 20+00 - 31+00 C-8 WINDING SPRING DR. - PROFILE 30+00 - 41+00 C-9 BRD. LEAF - PROF 10+00 - 13+94 & STRM. VW. - PROF. 10+00 - 14+37 C-10 ABBOTT ST. - PROFILE 10+00 - 19+60 C-11 SHALLOW SPRING DR. PLAN - PROFILE 30+00 - 39+76 C-12 FADED CARDINAL LN. - PROFILE 20+00 - 25+43 C-13 EXISTING SANITARY SEWER - OUTFALL'A' C-14 EXISTING SANITARY SEWER - OUTFALL 'A' C-15 SANITARY SEWER OUTFALL'B' C-16 SAN SEWER OUTFALL - 'C' & 'D' C-17 OVERALL OFF -SITE SAN. SEWER OUTFALL 1 C-18 OFF -SITE SAN. SEWER OUTFALL PLAN -PROFILE 1 C-19 OFF -SITE SAN. SEWER OUTFALL PLAN -PROFILE 1 C-20 OFF -SITE SAN. SEWER OUTFALL PLAN -PROFILE 1 C-21 SITE & UTILITY PLAN - WEST C-22 SITE & UTILITY PLAN - SOUTHWEST C-23 SITE & UTILITY PLAN SOUTHEAST C-24 - SITE & UTILITY PLAN EAST G-1 GRADING & DRAINAGE PLAN - WEST G-2 GRADING & DRAINAGE PLAN - SOUTHWEST G-3 GRADING & DRAINAGE PLAN - SOUTHEAST G-4 GRADING & DRAINAGE PLAN - EAST G-5 STORM SCHEDULE G-6 HYDRAULIC TABLES P-1 STORM PROFILES P-2 STORM PROFILES P-3 STORM PROFILES EC-1 PHASE 1 EC -TOWN HOMES EC-2 PHASE 1 EC -SINGLE FAMILY EC-3 PHASE 2 EC TOWNHOMES EC-4 PHASE 2 EC -SINGLE FAMILY EC-5 TYPICAL LOT EROSION CONTROL PLAN M of 1 LIGHTING PLAN L-1 LANDSCAPE PLAN L-2 SCM PLANTING PLANS L-3 WET POND REQUIREMENTS L 4 LANDSCAPE DETAILS D-1 SITE DETAILS D-2 SITE & STORM DETAILS D-3 SANITARY AND WATER DETAILS D-4 EROSION CONTROL DETAILS D-5 EROSION CONTROL DETAILS D-6 TSB DETAILS D-7 TSB DETAILS D-8 SCM DETAILS D-9 SCM DETAILS SITE INFORMATION OWNER: (SEE OWNER INFORMATION ON THIS SHEET) DEVELOPER: MERITAGE HOMES 3300 PARAMOUNT PARKWAY, STE 120 MOORESVILLE, NC 27560 JURISDICTION: MEBANE STATE: NORTH CAROLINA PARCEL PIN(S): 9825404628, 9825502531, 9825601982, 9825529420, 9825614053,9825604799 NET LAND AREA: 133.90 ACRES EXISTING ZONING: R-8 (CD) & R-10 (CD) CURRENT USE: VACANT INDUSTRIAL/RESIDENTIAL USES, EX. AGRICULTURAL USES PROPOSED USE: SINGLE FAMILY & TOWNHOUSE RESIDENTIAL USES RIVER BASIN: CAPE FEAR WATERSHED: JORDAN LAKE SUB WATERSHED: HAW CREEK PROPOSED # OF LOTS: 85 MIN. LOT SIZE: 2,020 SF MAX. LOT SIZE: 7,260SF PROPOSED R-10 (CD) SINGLE FAMILY LOT INFORMATION- PHASE 1 PROPOSED # OF LOTS: 59 MIN. LOT SIZE: 6,500 SF MAX. LOT SIZE: 13,947 SF BUILDING SETBACKS R-10/SF FRONT YARD SETBACK: 25 FEET SIDE YARD SETBACK: 5 FEET MIN. CORNER YARD SETBACK: 13 FEET REAR YARD SETBACK: 20 FEET MAX. BUILDING HEIGHT: 35 FEET BUILDING SETBACKS R-8/TH FRONT SETBACK: 20 FEET SIDE SETBACK OF BUILDING ENDS: 15 FEET SIDE SETBACK FROM PUBLIC STREET R/W: 15 FEET REAR SETBACK: 20 FEET MAX. BUILDING HEIGHT: 40 FEET PARKING FOR PHASE 1 REQUIRED: • SINGLE FAMILY UNITS: 2 SPACES/UNIT x 58 LOTS = 116 SPACES • TOWNHOUSE UNITS: 2.5 SPACES/UNIT x 85 UNITS = 213 SPACES • SWIM CLUB/POOL: 1 SPACE/100 S.F. OF DECK AND POOL SURFACE AREA = 6800 S.F = 68 SPACES • HANDICAP SPACES REQUIRED = 3 SPACES (BASED ON THE 68 SPACES PROVIDED AT SWIM CLUB FACILITY) • TOTAL REQUIRED = 397 SPACES PROVIDED: • TOWNHOUSE UNITS: 55 (1-CAR GARAGE) x 2/UNIT = 110 SPACES • TOWNHOUSE UNITS: 30 (2-CAR GARAGE) x 4/UNIT = 120 SPACES • SINGLE FAMILY LOTS: 58 LOTS (1-CAR GARAGE) X 2/LOT = 116 SPACES • KIOSK & CLUBHOUSE: 68 SPACES (INCLUDES 1 VAN ACCESSIBLE AND 2 STANDARD HC SPACES PROVIDED) • TOTAL PARKING SPACES PROVIDED: 414 SPACES (3 HC) • BICYCLE PARKING SPACES PROVIDED: 12 SPACES (AT SWIM CLUB FACILITY) OPEN SPACE CALCULATIONS FOR ALL PHASES: TOWNHOMES LOTS 1-129 (R-8 ZONING) REQUIRED OPEN SPACE: 500 SQ. FT./UNIT X 129 UNITS = 64,500 SQ. FT. OR 1.48 ACRES SINGLE FAMILY LOTS 130-403 (R-10 ZONING CONSERVATION SUBDIVISION OPTION) REQUIRED MIN. LOT AREA: 273 LOTS X 10,000 SQ. FT./LOT = 2,730,000 SQ. FT. OR 62.67 ACRES AREA PROVIDED WITHIN LOTS USING REDUCED LOT SIZE PER CONSERVATION OPTION = 58.09 ACRES REQUIRED OPEN SPACE FOR SINGLE FAMILY LOTS: 62.67 - 58.09 = 4.58 ACRES TOTAL REQUIRED OPEN SPACE: 4.58 + 1.48 = 6.06 ACRES TOTAL OPEN SPACE PROVIDED: 58.09 ACRES (OPEN SPACE AREAS 1 THRU 11) (±18 ACRES IN PROTECTED TREE AREAS) PUBLIC RECREATION SPACE CALCULATIONS REQUIRED SPACE EQUALS 1/35 OF AN ACRE PER DWELLING UNIT 403 UNITS X 1/35 ACRE = 11.51 ACRES REQUIRED PAYMENT -IN -LIEU VALUE = $205,393 IMPERVIOUS AREA EXISTING: 53,842 S.F. (0.92% OF TOTAL SITE) PHASE 1 ROAD: 174,240 S.F. AMENITY CENTER & PARKING: 57,064 S.F. SIDEWALK: 71,002 S.F. ROOF: 268,800 S.F. DRIVE & WALKS: 72,750 S.F. TOTAL FOR PHASE 1 643,856 S.F. DISTURBED AREA PHASE 1 ON SITE = 32.985 AC. (1,436,827 S.F.) TANGIER OUTFALL = 1.189 AC. (50,483 S.F.) TOTAL = 34.144 AC. (1,487,310 S.F.) W OO��z.U,-= U V] N Q U W ZO Z W= Z m U Z LL U W: w a o LL 0 NO � V Z Z- W H Z Z W a H N z x QC7� o �oo(<< U) U)W ' 0=waWaWwOZa C7 W ���Lu�aQ�Z)w W Q - , W Z~ c) P Q p O W j LL cb z o�=0WzU)xWZO W a- Z a OZQ�Wz�UW20 o QUw����aQ�a p¢u)w�0wOzW m z � O W U H f- U W Q W U_ U' Z 0 a Q Q O W 0 `=z�W�°x}O �� r�mz O W U LLi Q � w cQ @) U` U W O d W Z U W W d O LU @ Y Y U a } m Z > > K 0_j O U wo cn o z � U J w 0 w n SQ N o UF-) 2 o LL o �N U 05257�7 13-2-023 LL/''•�1GINE�Q��`• /AM R- /IIIIIIII\\ to W 7 W y cz z � W � W Z N ca It- W � w M t- N M tA Ly �, N � O C a o U r? U ikuzM 6 � y W�cq_ V 0 U) M 0 C7 z O Q � Z W °0W W [� O W W U �U pZ O W O Ym U0oL2LE, LU 2 NLU 0. LLJ O I. - (PROJECT NO. 19-0139 DRAWING NAME: 19-0139_CS.dwg SHEET NO. C-1 Susan Wilson September 5, 2023 Environmental Engineer Water Quality Regional Operations — Raleigh Regional Office North Carolina Department of Quality Ms. Wilson, Please see the responses below to your comments on the Oakwood Phase I WQ0044608 provided on August 27, 2023. The responses provided in this letter are numbered to match the comments that they address. The original comments are attached below. The City of Mebane Director of Utilities informed us that these permit numbers were assigned before his time so they were not provided at the time of application. The director was able to locate the downstream sewer flow diagram attached which provides the permit number: WQ0032351. This permit number is provided on the revised permit application. 2. "No" was checked in error, "Yes" has been checked on the revised permit application. 3. 144 units is correct; the flow calculations have been corrected on the permit application. An updated plan cover sheet is also provided with this submittal. 4. None of the proposed sanitary sewer lines associated with this project meet the definition of high priority lines. The proposed sewer connects to an existing network within the project limits that is assumed to have been permitted before its installation. This application does not address the status of the existing sanitary sewer lines. 5. A sewer flow diagram is provided with this submittal. If you have any further questions please feel free to reach out to me directly. Thank you, William Wirt, PE Headquarters Office 320 Executive Court, Hillsborough, NC 27278 919.732.3883 // www.summitde.com William Wirt, PE From: Wilson, Susan A <susan.wilson@deq.nc.gov> Sent: Sunday, September 3, 2023 11:39 AM To: Mick Parker Cc: Mehl, Chris; Leticia Raimond; William Wirt, PE Subject: RE: [External] RE: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 Yes —that would be great. As long as Chris with Mebane is OK if we sub in the corrected/modified pages into the application, then we don't have to get updated signatures. From: Mick Parker <mick.parker@summitde.com> Sent: Friday, September 1, 2023 1:59 PM To: Wilson, Susan A <susan.wilson@deq.nc.gov> Cc: Mehl, Chris <Chris.Mehl@meritagehomes.com>; Leticia Raimond <leticia.raimond@summitde.com>; William Wirt, PE <william.wirt@summitde.com> Subject: [External] RE: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Susan, Can we send these updated documents via email to expedite the process? Thank you Mick Parker Project Coordinator Tel: 919-732-3883 x3144 SU11*1t11T DESIGN AMU ENGINEERING SERVICES i! rive n k-r From: Mehl, Chris <Chris.Mehl@meritagehomes.com> Sent: Monday, August 28, 2023 9:25 AM To: Mick Parker <mick.parker@summitde.com>; Leticia Raimond <leticia.raimond@summitde.com> Subject: FW: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 Good Morning Mick and Leticia, Could you please respond to the questions in Will's absence this week. I'd like to keep this process moving as quickly as possible. Thanks, Chris Mehl, PE — Land Development Manager 1 O: 919.926.2636 1 C: 919.768.2346 1 F: 919.926.2601 https://link.edgepilot.com/s/13f5d73c/OaZHrGdvQkCDMfn7ntyx-Q?u=http://www.meritagehomes.com/ This email may contain confidential and privileged material for the sole use of the intended recipient(s). Any review, use, distribution or disclosure by others is strictly prohibited. If you have received this communication in error, please notify the sender immediately by email and delete the message and any file attachments fron Nmi it computer. From: Wilson, Susan A <susan.wilson@deg.nc.Rov> Sent: Sunday, August 27, 2023 8:14 PM To: Will Wirt <william.wirt@summitde.com>; Mehl, Chris <Chris.Mehl@meritaRehomes.com> Cc: crollins@cityofinebane.com Subject: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 Hi folks — Just a few questions after a brief review — 1. Part V of the application — could no one find a downstream permit? The City of Mebane doesn't know what it may be? Do they have any idea what it may be called or is it just that old? If they can come up with a possible name for it I can try to look it up. 2. Part VI.6 of the application — you provided a flow reduction letter and used that for the flow calculations — so please check YES on that (not sure why NO was indicated) 3. Part VI.8 — this figure does not match (seems 1 unit more that what was calculated in 7.) Please correct. Also the narrative indicates 144 units (and not 143 as in the flow calculations). 4. Would you reconfirm that there are no high priority lines with this project? 5. Would you provide a basic sewer flow diagram? (I've attached one if you can provide something similar). Thanks, Susan Wilson Environmental Engineer (Part Time, Temporary) Water Quality Regional Operations — Raleigh Regional Office NC Department of Environmental Quality Office: 919-791-4240 EffmW cnrrespe dwxe ro a" from ehfs a ddmas rs se bpa ra Me North Cara.G'na?ubh'e RLmrds Lax and may be drsd&sad no third parties Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. Links contained in this email have been replaced. If you click on a link in the email above, the link will be analyzed for known threats. If a known threat is found, you will not be able to proceed to the destination. If suspicious content is detected, you will see a warning. CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Links contained in this email have been replaced. If you click on a link in the email above, the link will be analyzed for known threats. If a known threat is found, you will not be able to proceed to the destination. If suspicious content is detected, you will see a warning. CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Wilson, Susan A From: William Wirt, PE <william.wirt@summitde.com> Sent: Friday, September 8, 2023 11:51 AM To: Wilson, Susan A; Mick Parker; crollins@cityofinebane.com Cc: Mehl, Chris; Leticia Raimond; Franz Holt; Preston Mitchell; Smith, Kyle Subject: RE: [External] RE: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Yes, ma'am, happy to help. Chris Rollins, the City manager, may not have capacity to respond so I've copied Franz Holt the Town Engineer and Preston Mitchell the Assistant City Manager and Kyle Smith the Director of Utilities who cover the development work on Chris' behalf. Gentlemen, please see below for Susan's comments please advise as to your satisfaction to the responses provided. El 2023-09-05 NCDEQ Revised Sewer App Docs William Wirt, PE Project Manager Tel: 919-732-3883 x3151 Cell: 757-621-5482 4SUMMIT 0U19M AtlQ llBlptER1RB BERMILi9 PO N% "I From: Wilson, Susan A <susan.wilson@deq.nc.gov> Sent: Wednesday, September 6, 2023 12:09 PM To: William Wirt, PE <william.wirt@summitde.com>; Mick Parker <mick.parker@summitde.com>; crollins@cityofinebane.com Cc: Mehl, Chris <Chris.MehI@meritagehomes.com>; Leticia Raimond <leticia.raimond@summitde.com> Subject: RE: [External] RE: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 Thank you, Will, this helps a lot. I am fine with this digital submittal as long as Chris Rollins (Mebane) is OK with these corrections and clarifications. From: William Wirt, PE <william.wirt@summitde.com> Sent: Tuesday, September 5, 2023 3:55 PM To: Wilson, Susan A <susan.wilson@deg.nc.gov>; Mick Parker <mick.parker@summitde.com> Cc: Mehl, Chris <Chris.Mehl@meritagehomes.com>; Leticia Raimond <leticia.raimond@summitde.com> Subject: RE: [External] RE: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Susan, Please see the link below for the revised documents. Please confirm if we need to mail hard copies to you, which includes a response to comments. Let me know if you have any issues accessing the link. El 2023-09-05 NCDEQ Revised Sewer ADD Docs William Wirt, PE Project Manager Tel: 919-732-3883 x3151 Cell: 757-621-5482 SUMMT III in rive wr From: Wilson, Susan A <susan.wilson@deg.nc.gov> Sent: Sunday, September 3, 2023 11:39 AM To: Mick Parker <mick.parker@summitde.com> Cc: Mehl, Chris <Chris.Mehl@meritagehomes.com>; Leticia Raimond <leticia.raimond@summitde.com>; William Wirt, PE <william.wirt@summitde.com> Subject: RE: [External] RE: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 Yes — that would be great. As long as Chris with Mebane is OK if we sub in the corrected/modified pages into the application, then we don't have to get updated signatures. From: Mick Parker <mick.parker@summitde.com> Sent: Friday, September 1, 2023 1:59 PM To: Wilson, Susan A <susan.wilson@deg.nc.gov> Cc: Mehl, Chris <Chris.Mehl@meritagehomes.com>; Leticia Raimond <leticia.raimond@summitde.com>; William Wirt, PE <william.wirt@summitde.com> Subject: [External] RE: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Susan, Can we send these updated documents via email to expedite the process? Thank you N Mick Parker Project Coordinator Tel: 919-732-3883 x3144 SUMM E FIIEII�EF1E111� 1ERIEIM 1n title +� r From: Mehl, Chris <Chris.Mehl@meritagehomes.com> Sent: Monday, August 28, 2023 9:25 AM To: Mick Parker <mick.parker@summitde.com>; Leticia Raimond <leticia.raimond@summitde.com> Subject: FW: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 Good Morning Mick and Leticia, Could you please respond to the questions in Will's absence this week. I'd like to keep this process moving as quickly as possible. Thanks, Chris Mehl, PE —Land Development Manager 1 O: 919.926.2636 1 C: 919.768.2346 1 F: 919.926.2601 https://link.edgepilot.com/s/13f5d73c/OaZHrGdvQkCDMfn7ntyx-Q?u=http://www.meritagehomes.com/ iva cinau uiay U-111-1—i aiiu Ni...._­ ilia iciiai iUl Ll- 0— — Ui Ll- uiic1 — I Niciiy 1-1—, —, U-1 Uuu— _. _.__.___._ , others is strictly prohibited. If you have received this communication in error, please notify the sender immediately by email and delete the message and any file attachments fron your computer. From: Wilson, Susan A <susan.wilson@deg.nc.gov> Sent: Sunday, August 27, 2023 8:14 PM To: Will Wirt <william.wirt@summitde.com>; Mehl, Chris <Chris.Mehl@meritagehomes.com> Cc: crollins@citvofinebane.com Subject: Fast Track Sewer Application Oakwood Subd Phase 1 WQ0044608 Hi folks — Just a few questions after a brief review — 1. Part V of the application — could no one find a downstream permit? The City of Mebane doesn't know what it may be? Do they have any idea what it may be called or is it just that old? If they can come up with a possible name for it I can try to look it up. 2. Part VI.6 of the application — you provided a flow reduction letter and used that for the flow calculations — so please check YES on that (not sure why NO was indicated) 3. Part V1.8 — this figure does not match (seems 1 unit more that what was calculated in 7.) Please correct. Also the narrative indicates 144 units (and not 143 as in the flow calculations). 4. Would you reconfirm that there are no high priority lines with this project? 5. Would you provide a basic sewer flow diagram? (I've attached one if you can provide something similar). Thanks, Susan Wilson Environmental Engineer (Part Time, Temporary) Water Quality Regional Operations — Raleigh Regional Office NC Department of Environmental Quality Office: 91 9-791-4z4o E Q3 Emau cnrreip,arrdame do aad faarn thfr eddre m ns :er4to- the Nwh Caro[neRuMc Rwards'_ewardfna) be &'dosed to thirdpartes Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. Links contained in this email have been replaced. If you click on a link in the email above, the link will be analyzed for known threats. If a known threat is found, you will not be able to proceed to the destination. If suspicious content is detected, you will see a warning. CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Links contained in this email have been replaced. If you click on a link in the email above, the link will be analyzed for known threats. If a known threat is found, you will not be able to proceed to the destination. If suspicious content is detected, you will see a warning. CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Links contained in this email have been replaced. If you click on a link in the email above, the link will be analyzed for known threats. If a known threat is found, you will not be able to proceed to the destination. If suspicious content is will see a warni CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. NI~ Dept ofNvlronmenta1 Quality State of North Carolina Department of Environmental Quality DWR. Division of Water Resources JUL 2 4 2023 FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: Wdpia;O4d (v05 (to be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: City of Mebane (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately Owned Public Utility ❑ Federal ❑ Stater'County ® Municipal ❑ Other 3. Signature authority's name: Chris Rollins per 15A NCAC 02T .0106(b} Title: City Manager 4. Applicant's mailing address: 106 E. Washington Street City: Mebane State: NC Zip: 27302 5. Applicant's contact information: Phone number: (19) 562-5901 Email Address: crollinsAcityof mebane.com Il. PROJECT INFORMATION: 7) P 1. Project name: Oakwand Subdivision Phase 1 2. Application/Project status: ®Proposed (New Permit) ❑ Existing Permit/Project `r �1 C If a modification, provide the existing permit number: WQ00 _ and issued date: V For modifications, also attach a detailed narrative description as described in Item G of the checklist. zv5 -U ti If new construction, but part of a master plan, provide the existing permit number: WQ00 b r 3. County where project is located: Orange County 1 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.087839 Longitude:-7.9,251508 5. Parcel ID (if applicable): 9825404628 9825502531 9825601982 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: William R. Wirt License Number: 052574 Firm: Summit Design and Engineering Services C Mailing address. 320 Executive Court City: Hillsborough State: NC Zip: 27278 L c 4 v Phone number: 919) 732-3883 Email Address: william.wirtCa�summitde.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: City of Mebane Water Resource Recovery Facility Permit Number: NCO021474 Owner Name: City of Mebane .1�1 V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ 2. Downstream (Receiving) Sewer Information: 8" inch ® Gravity Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00081 Owner Name(s): City of Mebane FORM: FTA 06-21 Page 1 of 5