HomeMy WebLinkAboutNC0029599_NC0029599 Factsheet 2023_20231108NCDEQ / DWR / NPDES
EXPEDITED FACT SHEET - NPDES PERMIT RENEWAL
NPDES Permit NCO029599
Sara Bassett / Compliance & Expedited Permitting Unit / sara.bassettkdeq.nc. og_v / November 2023
FACILITY INFORMATION
Applicant/Facility Name
Courtney Elementary School WWTP
Facility Address
2529 Courtney -Huntsville Road
Mailing Address
121 Washington St, Yadkinville NC 27055
Permitted Flow (MGD)
0.005 MGD
Type of Waste
100% Domestic, < 1 MGD
Facility Class
WW-1
County
Yadkin
Permit Status
Renewal
Regional Office
Winston-Salem
STREAM CHARACTERISTICS
Receiving Stream
Harmon Creek
Stream
Classification
WS-IV
Stream Segment
12-84-2-6- 2
Outfall Lat.
36.0842 N
7Q10 - Summer (cfs)
0.44
Outfall Long.
80.6103 W
7Q10 - Winter (cfs)
1.21
Drainage basin
Yadkin -Pee Dee
30Q2 (cfs)
Subbasin
03-07-02
Average Flow (cfs)
3.95
HUC
0304010111
303(d) List
No
BASIC INFO FOR EXPEDITED PERMIT RENEWAL
Does permit need Daily Max NH3 limits?
N/A — NH3 limits are not required for this facility
Does permit need TRC limits/footnote?
Already present
Does permit have toxicity testing?
No
Does permit have any Special Conditions?
Added UV policy, already has High Rock Lake nutrient
reopener
Does permit have instream monitoring?
No
New expiration date:
December 31, 2028
1. FACILITY SUMMARY
Courtney Elementary School sends 100% domestic discharge to the Courney Elementary School WWTP.
This is a minor facility (flow < 1 MGD) with a design capacity and permitted wastewater discharge of 0.005
MGD that includes the following components:
➢ 1,000-gal Grease trap
➢ 12,000-gal Septic tank
➢ Siphon dosing tank
➢ Surface sandfilter
➢ Recirculation tank with dual pumps
➢ UV disinfection [with backup chlorine & dechlorination tanks]
➢ Effluent pump station with dual pumps
RENEWAL SUMMARY
This renewal contains the following changes:
• Updated Section A. (4) to reflect current federal requirements for Electronic Reporting of
Discharge Monitoring Reports.
• Section A.(2) has been added per the Division's policy for ultraviolet disinfection systems.
COMPLIANCE HISTORY
3 notice of violation for fecal coliforms in the last permit cycle, no enforcements.
COMMENTS ON DRAFT PERMIT