Loading...
HomeMy WebLinkAboutNCG550039_Staff Report_19941110 SOC PRIORITY PROJECT: Yes No If Yes, SOC No. To: Permits and Engineering Unit Water Quality Section Attention: Mack Wiggins r Date: November 10, 1994 O3-0 - O1 NPDES STAFF REPORT AND RECOMMENDATION tcc County:Durham General Permit No. : NCG550039 PART I - GENERAL INFORMATION 1 . Applicant facility and address : Clarence and Bernice Brandon 3734 E. Geer Street Durham, NC 27704 2 . Date of Investigation: November 9 , 1994 3 . Report Prepared by: Peggy Redmond 4 . Persons Contacted and Telephone Number: Mrs . Bernice Brandon - HOME (919 ) 682-8601 5 . Directions to Site: From Raleigh, take U. S . 70 to Durham. Take the Geer Street Exit to I-85 . Go approximately 5 miles past Gorman. House is approximately 1 on the right off a side dirt road. 6 . Discharge Point(s) , List for all discharge points : Latitude: 36°02'50"N Longitude: 78°48'10"W Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G. S . Quad No. : C 23 SE U. S .G. S . Quad Name: NE Durham 7 . Site size and expansion area consistent with application ? XX Yes No If No, explain: 8 . Topography (relationship to flood plain included) : Lot relatively flat, no trees with heavy undergrowth on back of lot. 4. SOC PRIORITY PROJECT: Yes No If Yes, SOC No. 9 . Location of nearest dwelling: Approximately 75 feet next door. Use private wells . 10 . Receiving stream or affected surface waters : fUTfto Panther4 Creek - Index number 27-6 ( 1) a. Classification: WS-IV NSW b. River Basin and Subbasin No. : 0!E04 -011 c. Describe receiving stream features and pertinent downstream uses : Panther Creek drains to Neuse River and Falls Lake PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1 . a. Volume of Wastewater to be permitted: 360 GPD (Ultimate Design Capacity) b. What is the current permitted capacity of the Waste Water Treatment facility? N/A c. Actual treatment capacity of the current facility (current design capacity) ? 360 GPD d. Please provide a description of existing or substantially constructed wastewater treatment facilities : Septic tank sand filter system with a newly installed chlorinator. 2 . Residuals handling and utilization/disposal scheme: As necessary by approved hauler. 3 . Treatment plant classification (attach completed rating sheet) : Class 1 4 . SIC Code(s) : 4952 Wastewater Code(s) of actual wastewater, not particular facilities i .e. . , non-contact cooling water discharge from a metal plating company would be 14 , not 56 . Primary 04 Secondary Main Treatment Unit Code: 4 4 0 - 7 SEPTIC TANK SAND FILTER PART III - OTHER PERTINENT INFORMATION 1 . Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipal only) ? No SOC PRIORITY PROJECT: Yes No If Yes, SOC No. 2 . Special monitoring or limitations (including toxicity) requests : None 3 . Other Special Items : The only possible toxic impacts to surface waters are from chlorine and/or ammonia. 4 . Alternative Analysis Evaluation: Has the facility evaluated all of the non-discharge options available? Please provide regional perspective for each option evaluated. Spray Irrigation: Not enough area available for buffers . Connection to Regional Sewer System: Not available at this time. Subsurface: Soils not suitable. Other disposal options : No alternatives available at this time. 5 . Other Special Items : N/A PART IV - EVALUATION AND RECOMMENDATIONS Based upon this site visit, the septic system appeared to be working well . Chlorine tablets were in the chlorinator, and the effluent was clear. Mr. Brandon was advised to keep the area around the tail line clear. The RRO recommends issuing the Certificate of Coverage (NCG550039 ) under General Permit Number NCG550000 . Signature of report preparer Water Quality Regional Supervisor Date BRANDON.REP