Loading...
HomeMy WebLinkAboutNCG550013_Wasteload Allocation_19930610 . moo-r- - > , AC1-1Jc c{ GYz i , ilZ lr- al `esON :+..G. — ` — NPDES WASTE LOAD ALLOCATION ,6-:" h• , (tJc.CYS50 o tsm �G PERMIT NO.: — Mod DateRe 3 # ,,� of L — PERMITFEE NAME: Geneco, Inc. 2 �/r ( � 7�9/ �s FACILITY NAME: Geneco, Inc. Drainage Area(nu ) Avg. Streamflow (cfs): Facility Status: Existing 7Q10(cfs) Winter 7Q10 (cfs) 30Q2 (cfs) Permit Status: Renewal Toxicity Limits:IWC % Acute/Chronic Major Minor 11 Instream Monitoring: •, Pipe No.: 001 Parameters Design Capacity: 0.000375 MGD Upstream Location _ Domestic (% of Flow): 100 % Downstream Location Industrial (% of Flow): Effluent Summer Winter Comments: leo re ce^^M eia(s d Q 1 e 4 e M O a,f or 142, Characteristics SP114 .- BOD5 (mg/1) 1 ,te i /� �-;/-� � NH3-N (mg/1) D.O. (mg/1) RECEIVING STREAM:an unnamed tributary to Mud Creek Class: WS IV TSS (mg/1) Sub-Basin: 04-03-02 F. Col. (/100 ml) Reference USGS Quad: F8NE (please attach) County: Henderson pH (SU) Regional Office: Asheville Regional Office / Previous Exp. Date: 8/31/93 Treatment Plant Class: Classification changes within three miles: - g �,,r„ ) --!>11:13 Requested by: Charles Alvarez Date: 6/3/93 Prepared by: Date: _ Comments: -bc`_e`Ep 'K wLA 1."' ' l-k-°"'e•r _ / `'4 `s \>e'`-'"'` .d Reviewed by: Date: ate. -�l.r<#-P'S'- A—.- 'g. "��" rz ! r. SOC PRIORITY PROJECT: No ` IF YES, SOC NUMBER TO: PERMITS AND ENGINEERING UNIT WATER QUALITY SECTIONre, ATTENTION: Ch e're �AIvz DATE: February 17, 1993 NPDES STAFF REPORT AND RECOMMENDATION COUNTY Henderson IO fe .- PERMIT NUMBER NC0062588 PART I - GENERAL INFORMATION `����� M""``�"r 1. Facility and Address: Geneco, Inc . 201 Newman Drive Hendersonville, N. C. 28739 2 . Date of Investigation: December 4, 1992 . 3 . Report Prepared By: Paul White 3' v -- 4. Persons Contacted and Telephone Number: " r / � 5. Directions to Site: From the Highway 25 south exit from I-26, `, proceed southward toward Hendersonville for approximately 1 . 5 miles to the intersection of SR 1367 on the right and Geneco, Inc. on the left. The subsurface sand filter is located <100 feet southeast of the building. 6. Discharge Point(s) , List for all discharge points: Latitude: 35° 22 ' 48" Longitude: 82° 30' 13" Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G.S. Quad No. F8NE U. S.G. S. Quad Name Skyland 7. Site size and expansion area consistent with application? Yes Yes No If No, explain: 8. Topography (relationship to flood plain included) : Flat, not in flood plain. Page 1 9. Location of nearest dwelling: >100 feet 10. Receiving stream or affected surface waters: UT Mud Creek a. Classification: WS-IV b. River Basin and Subbasin No. : French Broad 040302 c. Describe receiving stream features and pertinent downstream uses: Receiving stream drains suburban and agricultural land. Wetland areas border the stream between the discharge point and Mud Creek. Downstream uses include fish and wildlife propagation, fishing, canoeing, and proposed water supply for the City of Asheville. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted .000375 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the Wastewater Treatment facility? . 000375 MGD c. Actual treatment capacity of the current facility (current design capacity .000375 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years: NONE e. Please provide a description of existing or substantially constructed wastewater treatment facilities: Septic tank and subsurface sand filter with inspection port and outfall line. The outfall line is plugged with a screwed plug. f. Please provide a description of proposed wastewater treatment facilities: n/a g. Possible toxic impacts to surface waters: Ammonia, bathroom cleaning agents. h. Pretreatment Program (POTWs only) : n/a in development approved should be required not needed 2. Residuals handling and utilization/disposal scheme: None specified a. If residuals are being land applied, please specify DEM Permit Number Residuals Contractor Telephone Number b. Residuals stabilization: PSRP PFRP OTHER Page 2 c. Landfill: d. Other disposal/utilization scheme (Specify) : 3 . Treatment plant classification (attach completed rating sheet) : I 4. SIC Codes(s) : 4952 Wastewater Code(s) of actual wastewater, not particular facilities i .e. , non-contact cooling water discharge from a metal plating company would be 14, not 56. Primary 02 Secondary Main Treatment Unit Code: 440-7 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved. (municipals only)? No 2 . Special monitoring or limitations (including toxicity) requests: None 3 . Important SOC, JOC, or Compliance Schedule dates: (Please indicate) None Date Submission of Plans and Specifications Begin Construction Complete Construction 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non-discharge options available. Please provide regional perspective for each option evaluated. Spray Irrigation: Possible Connection to Regional Sewer System: None available at this time. Subsurface: Not likely with native soil. Other disposal options:• 5. Other Special Items: Please recheck drainage area/7Q10 flows. Page 3 PART IV - EVALUATION AND RECOMMENDATIONS The facility is a septic tank and subsurface sand filter operating with no surface water discharge. It is recommended that the permit be reissued. Since there is no discharge from the facility, it is recommended that the monitoring and certified operator requirements be deleted from the permit, pursuant to 15A NCAC 2B . 0508 (b) ( 1) . The permit should contain a requirement to connect to a public sewer when available. p(a_ Signature of Report Pr parer --11-/(/ ater Qu lity Regional Supervisor 19- /7 f_3 Date /Vp r� 7`O 74)swe' -►-�G a E'. � Page 4 /�